0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
GLAC20A1T

GLAC20A1T

  • 厂商:

    HONEYWELL(霍尼韦尔)

  • 封装:

  • 描述:

    SWITCH SNAP ACTION DPDT 6A 120V

  • 数据手册
  • 价格&库存
GLAC20A1T 数据手册
MICRO SWITCH Global Limit Switches GLA Series 002408 Issue 4 Datasheet FEATURES DESCRIPTION Honeywell’s MICRO SWITCH GLA Limit Switch Series is designed to global EN50041 standards and well suited for worldwide applications. The modular design (heads/actuators, bodies, and contact blocks) of the limit switch allows for rapid response to meet customer applications. The rugged die-cast metal housing of the switch is ideal for indoor and outdoor applications where a degree of IP or NEMA enclosure sealing is required. Normally closed snap-action contacts and normally closed slow-action contacts are positive opening . DIFFERENTIATION • Side rotary actuator incorporates dual bearing design which prevents side loading during operation • Removable contact block allows for ease of wiring • Modular design of limit switch (heads/actuators, bodies, and contact blocks) allows for rapid customization and delivery • Optional 1 LED or 2 LED pilot lights in limit switch front cover to indicate voltage present to switch and/or switch actuated • Specialty contact options, sequential (2-step style) action, and center neutral action PORTFOLIO The GLA Limit Switch Series with standard or plug-in housings (EN50041 design, with 30 mm x 60 mm mounting) complement the smaller GLC Series, GLD Series and GLE Series (EN50047 design, with 20 mm to 22 mm mounting). The GLA Series is part of the MICRO SWITCH Limit Switch Series that includes the HDLS Series (Heavy Duty Limit Switch) and General Purpose Limit Switch (LS) Series. Sensing and Internet of Things • Designed to EN50041 standard, 30 mm x 60 mm mounting • Available as a standard body or plug-in body with same footprint • Wide range of actuator heads and levers • Side rotary switches factory set for CW and CCW actuation; field adjustable for CW only or CCW only • Certified for global applications; UL/CSA (Americas/Canada), CE (Europe), CCC (Asia-Pacific)1 • Conforms to IEC/EN 60947-5-1, EN45545-2 (GLA/GLF Series) • Sealed to IP67 and NEMA/UL 1, 4, 12, and 13 • Operating temperatures as low as -40 °C to 85 °C [-40 °F to 185 °F] • Multiple connectivity options to meet most applications: four different threaded conduits, micro-change connectors, minichange connectors, Deutsch style 4-pin connector • One or two LED indicators available in switch body • Single pole double throw, two pole single throw contact blocks (1NC/1NO, 2NC, 2NO) are galvanically (electrically) isolated (Zb) and designed with bifurcated contacts • Two pole double throw contact block (2NC/2NO) has each pole galvanically (electrically) isolated (Zb) • Normally closed contacts are positive opening , except center neutral style • Contact blocks are available as snap action or slow action • Analog output available with side rotary actuator • Mechanical life up to 15 million operations POTENTIAL APPLICATIONS • Aerial lifts, boom lifts • Automotive assembly lines and machining centers • Agriculture equipment • Conveyors • Doors and apertures • Material handling • Machine tools • Railroad locomotives and railroad signaling equipment • Transportation hubs • Valves VALUE TO CUSTOMERS • Easy to install and maintain • Rugged metal construction CCC certification is not available on the GL Series Switches sold within Europe, Middle East, and Africa. Option for CCC certification in these regions is available upon request. 1 MICRO SWITCH Global Limit Switches, GLA Series Table 1. Specifications Characteristic Parameter Description EN50041 industrial grade limit switch, standard body or plug-in body with 30 mm x 60 mm mounting Certifications CE, CCC1, CSA, UL Conforming to standards IEC/EN 60947-5-1, EN45545-2 (GLA/GLF Series) Housing material Electrostatic epoxy coated zinc Actuators Side rotary, top pin plunger, top adjustable plunger, top roller plunger, top roller lever, wobble stick (multi-directional) actuator, cat whisker (multi-directional) actuator Termination 0.5-14 NPT; PG 13,5; M20; G 1/2 (PF 1/2); Deutsch style 4-pin connector; Micro-change connector; Mini-change connector; Pre-cabled Contact options* 1NC/1NO, 2NC, 2NO, 2NC/2NO, 2NC/2NO sequential, 2NC/2NO center neutral Contact type Snap action, slow action break-before-make (BBM), slow action make-before-break (MBB), slow action Contact material Silver alloy (standard), gold-plated (low-energy applications) Utilization category ac15, A300/A600; dc13, Q300 Rated operational voltage (Ue) 240 Vac, 600 Vac, 250 Vdc Rated operational current (Ie) 3 A, 1.2 A, 0.27 A Thermal current (Ith) 10 A, 2.5 A Rated insulation voltage (Ui) 300 V; 600 V Rated impulse withstand voltage (Uimp) 2500 V Short circuit protective device (SCPD), type, and rating Class J fuse, rated 10A, 600 V Pollution degree 3 Sealing IP67; NEMA/UL 1, 4, 12, and 13 Operating temperature -40 °C to 85 °C [-40 °C to 185 °F] side rotary actuator -25 °C to 85 °C [-13 °F to 185 °F] other actuators Mechanical life Up to 15 million operations Vibration (actuator not fitted) 10 g conforming to IEC 68-2-6 Shock (actuator not fitted) 50 g conforming to IEC 68-2-27 Options Standard limit switch with 1 LED pilot light (GLF Series) or 2 LED pilot lights (GLH Series) in front cover Plug-in limit switch with 1 LED pilot light (GLG Series) in front cover *Normally closed (NC) contacts are positive opening except for the center neutral limit switches 1 CCC certification is not available on the GL Series Switches sold within Europe, Middle East, and Africa. Option for CCC certification in these regions is available upon request. Table 2. Electrical Ratings Electrical Rating ac dc A600 Ue (Volts) AC15 Ie (Amps) 120 6 24 2.8 240 3 125 0.55 380 1.9 250 0.27 480 1.5 500 1.4 600 1.2 2 sensing.honeywell.com Q300 Ue (Volts) DC13 Ie (Amps) Gold-plated contacts 1 V 10 mA min. 50 V 100 mA max. MICRO SWITCH Global Limit Switches, GLA Series Figure 1. Product Nomenclature GL A A Switch Type Body Style (EN50041) Conduit GL Series Global Limit Switch A 01 B Plug-in B PG 13,5 07 22 F Non plug-in with 1 LED pilot light C 20 mm SPDT 24 02 1NC/1NO, snap action** G Plug-in with 1 LED pilot light D G 1/2 (PF 1/2) action, 12 snap 1 LED** H Non plug-in with 2 LED pilot lights A Non plug-in A 01 1NC/1NO, SPDT snap action 1NC/1NO, SPDT, gold contacts, snap action 1NC/1NO, SPDT 1NC/1NO, BBM, 03 SPDT, slow action 20 2NC, action, 36 slow gold contacts 38 mm fixed yoke, no rollers 7A 3A 38 mm fixed yoke, 19 x 6 nylon rollers 7B 150 mm x Ø6,4 mm plastic rod 141 mm x Ø6,7 mm coil spring 38 mm fixed yoke, 19 x 6 steel rollers 7C 7D 1 CW actuation only 2 CCW actuation only 153 mm x Ø4,7 mm steel coil spring 3 Head with lever to right 165 mm x Ø1,3 mm SST wire 4 Head with lever to left 5 Head with lever to mounting surface 6 Roller plunger perpendicular to mtg. surface 2NC/2NO, DPDT snap action, LED B Top pin plunger (SST) 1C 38 mm fixed, 25 x 12 nylon roller 3B 32 2NC/2NO, DPDT, snap action, gold contacts, LED C Top roller plunger, SST 12 x 5 mm roller 1T 38 mm fixed, 19 x 9 SST roller 4J 21 2NC/2NO, DPDT, snap action, sequential D Top roller lever, nylon 19 x 8 mm roller 1Y 38 mm fixed, 50 x 10 rubber roller 4K Adjustable aluminum rod, 200 mm max. Adjustable aluminum rod, 140 mm max. 2NC/2NO, DPDT, snap action, gold contacts, sequential H Top adjustable plunger 2A 38 to 93 mm adjustable, 19 x 6 nylon roller 4N Adjustable SST rod, 318 mm max. 8B 140 mm x Ø1,2 mm SST wire 190 mm x Ø1,2 mm SST wire E Wobble stick 2B 38 to 93 mm adjustable, 19 x 6 steel roller 5A 38 mm fixed offset, 19 x 6 nylon roller 8C 141 mm x Ø6,7mm SST coil spring K Cat whisker 2D 5B 38 mm fixed offset, 19 x 6 steel roller 1NC/1NO, SPDT, 2NC, 3 1B slow action, 31 34 MBB, gold contacts 06 slow action 1A Side rotary, center neutral SPDT, 04 1NC/1NO, MBB, slow action 25 35 Side rotary J 1NC/1NO, SPDT, 2NO, slow action, gold contacts A 38 mm fixed, 19 x 6 nylon roller 38 mm fixed, 19 x 6 steel roller slow action, 28 33 BBM, gold contacts 05 2NO, slow action Actuators or Levers* Heads Basic Switch 2NC/2NO, DPDT snap action 2NC/2NO, DPDT, gold contacts, snap action 0.5-14 NPT E7B 26 2NC/2NO, DPDT, snap action, LED, sequential 2NC/2NO, DPDT, snap action, gold contacts, LED, sequential 2NC/2NO, DPDT, snap action, center neutral 29 2NC/2NO, DPDT, snap action, gold contacts, center neutral 27 2NC/2NO, DPDT, snap action, LED, center neutral 30 2NC/2NO, DPDT, snap action, LED, center neutral, gold contacts 2W 38 to 93 mm adjustable, 38 x 5 nylon roller 38 to 93 mm adjustable, 38 x 12 rubber roller 2Y 38 to 93 mm adjustable, 50 x 10 rubber roller 8A * Levers beginning with codes 1 to 5 are for A and J style side rotary heads only. Actuators beginning with Code 7 are for E style wobble stick head only. Actuators beginning with Code 8 are for K style cat whisker head only. **NOTE: Basic switch codes 02 and 12 may only be used with body styles B and G. Sensing and Internet of Things 3 MICRO SWITCH Global Limit Switches, GLA Series Table 3. MICRO SWITCH GLA Series Side Rotary Order Guide 1NC/1NO 1NC/1NO Side rotary, no lever Snap action 0,33 [2.9] 21-22 13-14 Silver alloy 0,33 [2.9] 21-22 13-14 Goldplated 0,33 [2.9] 21-22 13-14 21-22 13-14 1NC/1NO Slow action, MBB Silver alloy 0,33 [2.9] 21-22 13-14 2NC Slow action Silver alloy 0,33 [2.9] 11-12 21-22 2NC/2NO Snap action Silver alloy 0,33 [2.9] Silver alloy 0,33 [2.9] Goldplated 0,33 [2.9] Silver alloy 0,33 [2.9] 21-22 13-14 Goldplated 0,33 [2.9] 21-22 13-14 1NC/1NO Snap action 1NC/1NO Snap action 26° 11-12, 21-22 13-14, 23-24 † 11-12 13-14 ‡ 21-22 23-24 0° † 11-12 13-14 ‡ 21-22 23-24 0° GLAA07A GLAC07A – – GLAC03A – GLAA04A – – – GLAC06A – GLAA20A – 75° min. > < > < – GLAA26J – 75° min. > < > < – GLAA29J – 75° min. > < – GLAA01A1A GLAC01A1A 2 LEDs (green & yellow) GLHA07A1A – – GLAA03A1A – – GLAA20A1A GLAC20A1A 2 LEDs (green & yellow) – GLHC24A1A 75° min. > < > < – GLAA21A1A – 75° min. > < > < – GLAA26J1A – 75° min. 26° 55°** 16° 16° 26° 75° min. > < 55°** 12° Differential travel 26° 55°** 75° min. > < 12° Differential travel 26° ** Silver alloy 0,33 [2.9] 11-12, 21-22 13-14, 23-24 Snap action – 75° min. > < 8° Differential travel 8° Differential travel 11-12, 21-22 13-14, 23-24 0,33 [2.9] – 8° Differential travel 8° Differential travel 0,33 [2.9] Silver alloy GLFA01A 12° Differential travel Silver alloy 2NC/2NO Center neutral 1 LED (yellow) 75° min. > < 75° min. 26° ** Snap action Snap action GLAC01A 26° 2NC/2NO 0,33 [2.9] GLAA01A 75° min. 38° ** 0,33 [2.9] Silver alloy – 75° min. > < 38° Silver alloy 2NC/2NO Sequential 55°** 26° ** Slow action, BBM Snap action 55°** 26° 1NC/ 1NO 2NC/2NO 55°** 12° Differential travel 0,33 [2.9] Snap action 26° 12° Differential travel Silver alloy 2NC/2NO Center neutral 20 mm Conduit 12° Differential travel Slow action, BBM Snap action 0.5-14 NPT Conduit Bar Chart (degrees) ¢ contact closed £ contact open 1NC/1NO 2NC/2NO Center neutral Side rotary, fixed lever, nylon roller Snap action Silver alloy With LED Pilot Light/s Snap action Operating Torque max. Nm [in-lb] Contact Type 1NC/1NO Contact Material Contact Arrangement Head and Lever Type Catalog Listing* 21-22 13-14 75° min. 38° 26° 55°** 75° min. > < 12° Differential travel 26° 55°** 75° min. > < 12° Differential travel 27° 11-12 13-14 21-22 23-24 42° 8° Differential travel 8° Differential travel † 11-12 13-14 ‡ 21-22 23-24 0° 16° 8° Differential travel 8° Differential travel * Note: When conduit style G1/2 (PF1/2) is required, change the 4th digit in the catalog listing to the letter D. For example, GLAA01A1A would change to GLAD01A1A for G1/2 conduit. When conduit style PG13,5 is required, change the 4th digit in the cagalog listing to the letter B. For example, GLAA01A1A would change to GLAB01A1A for PG13,5 conduit. ** Positive opening occurs. † Contacts 11-12, 13-14 operate in CCW direction. ‡ Contacts 21-22, 23-24 operate in CW direction. 4 sensing.honeywell.com MICRO SWITCH Global Limit Switches, GLA Series Table 3. MICRO SWITCH GLA Series Side Rotary Order Guide, continued 1NC/1NO 1NC/1NO 1NC/1NO Side rotary, fixed lever, steel roller Snap action Snap action Snap action Silver alloy 0,33 [2.9] 21-22 13-14 Silver alloy 0,33 [2.9] 21-22 13-14 Silver alloy 0,33 [2.9] 21-22 13-14 Goldplated 0,33 [2.9] 21-22 13-14 26° 21-22 13-14 2NC Slow action Silver alloy 0,33 [2.9] 11-12 21-22 2NC/2NO Snap action Silver alloy 0,33 [2.9] 11-12, 21-22 13-14, 23-24 Goldplated 0,33 [2.9] 11-12, 21-22 13-14, 23-24 Silver alloy 0,33 [2.9] 11-12, 21-22 13-14, 23-24 Silver alloy 0,33 [2.9] 11-12, 21-22 13-14, 23-24 Goldplated 0,33 [2.9] 11-12, 21-22 13-14, 23-24 2NC/2NO Center neutral 2NC/2NO Center neutral Snap action Snap action Snap action Silver alloy 0,33 [2.9] Silver alloy 0,33 [2.9] Goldplated 0,33 [2.9] 55°** 26° ** 0,33 [2.9] 2NC/2NO Sequential GLAC01A1B 1 LED (yellow) GLFA01A1B – 2 LEDs (green & yellow) GLHA01A1B GLHC01A1B – GLAA07A1B GLAC07A1B – GLAA03A1B – – GLAA04A1B – – GLAA06A1B GLAC06A1B 75° min. > < – GLAA20A1B GLAC20A1B 75° min. > < – GLAA22A1B – 1 LED (yellow) GLFA24A1B – 2 LEDs (green & yellow) – – 2 LEDs (green & yellow) GLHA32A1B – 75° min. > < > < – – GLAC21A1B 75° min. > < > < – GLAA26J1B – 75° min. > < > < – GLAA29J1B – 75° min. > < 75° min. > < 75° min. > < 12° Differential travel Silver alloy Snap action 55°** 26° Slow action, MBB 2NC/2NO GLAA01A1B 12° Differential travel 1NC/1NO Snap action 55°** 26° 21-22 13-14 2NC/2NO – 75° min. > < 12° Differential travel 0,33 [2.9] Snap action 55°** 26° Silver alloy 2NC/2NO 20 mm Conduit 12° Differential travel Slow action, BBM Snap action 0.5-14 NPT Conduit Bar Chart (degrees) ¢ contact closed £ contact open 1NC/1NO 2NC/2NO With LED Pilot Light/s Snap action Operating Torque max. Nm [in-lb] Contact Type 1NC/1NO Contact Material Contact Arrangement Head and Lever Type Catalog Listing* 75° min. 38° 75° min. 38° ** 26° 75° min. 26° ** 26° 55°** 12° Differential travel 26° 55°** 12° Differential travel 26° 55°** 75° min. > < 12° Differential travel 26° 55°** 75° min. > < 12° Differential travel 26° 55°** 75° min. > < 12° Differential travel 27° 11-12 13-14 21-22 23-24 42° 8° Differential travel 8° Differential travel † 11-12 13-14 ‡ 21-22 23-24 0° 16° 8° Differential travel 8° Differential travel † 11-12 13-14 ‡ 21-22 23-24 0° 16° 8° Differential travel 8° Differential travel * Note: When conduit style G1/2 (PF1/2) is required, change the 4th digit in the catalog listing to the letter D. For example, GLAA01A1A would change to GLAD01A1A for G1/2 conduit. When conduit style PG13,5 is required, change the 4th digit in the cagalog listing to the letter B. For example, GLAA01A1A would change to GLAB01A1A for PG13,5 conduit. ** Positive opening occurs. † Contacts 11-12, 13-14 operate in CCW direction. ‡ Contacts 21-22, 23-24 operate in CW direction. Sensing and Internet of Things 5 MICRO SWITCH Global Limit Switches, GLA Series Table 3. MICRO SWITCH GLA Series Side Rotary Order Guide, continued Contact Material Operating Torque max. Nm [in-lb] Silver alloy 0,33 [2.9] 21-22 13-14 Snap action Goldplated 0,33 [2.9] 21-22 13-14 2NC Slow action Silver alloy 0,33 [2.9] 11-12 21-22 2NC/2NO Snap action Silver alloy 0,33 [2.9] 11-12, 21-22 13-14, 23-24 Snap action Goldplated 0,33 [2.9] 11-12, 21-22 13-14, 23-24 Snap action Silver alloy 0,33 [2.9] 11-12, 21-22 13-14, 23-24 2NC/2NO Center neutral Snap action Silver alloy 0,33 [2.9] 1NC/1NO Snap action Silver alloy 0,33 [2.9] 21-22 13-14 Snap action Goldplated 0,33 [2.9] 21-22 13-14 Snap action Silver alloy 0,33 [2.9] 21-22 13-14 1NC/1NO Slow action, BBM Silver alloy 0,33 [2.9] 21-22 13-14 1NC/1NO Slow action, BBM Silver alloy 0,33 [2.9] 21-22 13-14 1NC/1NO Slow action, BBM Goldplated 0,33 [2.9] 21-22 13-14 2NC Slow action Silver alloy 0,33 [2.9] 11-12 21-22 2NC/2NO Snap action Silver alloy 0,33 [2.9] Snap action Silver alloy 0,33 [2.9] 1NC/1NO 1NC/1NO Side rotary, adjustable lever, nylon roller 2NC/2NO 2NC/2NO 1NC/1NO 1NC/1NO Side rotary, adjustable lever, steel roller 2NC/2NO Center neutral With LED Pilot Light/s Contact Type Snap action Contact Arrangement Head and Lever Type Catalog Listing* 0.5-14 NPT Conduit 75° min. > < – GLAA01A2A GLAC01A2A 75° min. > < – GLAA07A2A – – GLAA06A2A – 75° min. > < – GLAA20A2A – 75° min. > < – GLAA22A2A – 1 LED (yellow) GLFA24A2A – 75° min. > < > < – GLAA26J2A – 75° min. > < – GLAA01A2B GLAC01A2B 75° min. > < – GLAA07A2B GLAC07A2B 1 LED (yellow) GLFA01A2B GLFC01A2B – GLAA03A2B – 1 LED (yellow) GLFA03A2B – 1 LED (yellow) GLFA33A2B – – – GLAC06A2B – GLAA20A2B GLAC20A2B – GLAA26J2B – Bar Chart (degrees) ¢ contact closed £ contact open 26° 55°** 20 mm Conduit 12° Differential travel 26° 55°** 12° Differential travel 75° min. 26° ** 26° 55°** 12° Differential travel 26° 55°** 12° Differential travel 26° 55°** 75° min. > < 12° Differential travel † 11-12 13-14 ‡ 21-22 23-24 0° 16° 8° Differential travel 8° Differential travel 26° 55°** 12° Differential travel 26° 55°** 12° Differential travel 26° 55°** 75° min. > < 12° Differential travel 26° ** 75° min. 38° 26° ** 75° min. 38° 26° ** 75° min. 38° 75° min. 26° ** 11-12, 21-22 13-14, 23-24 26° 55°** 75° min. > < 12° Differential travel † 11-12 13-14 ‡ 21-22 23-24 0° 16° 75° min. > < > < 8° Differential travel 8° Differential travel * Note: When conduit style G1/2 (PF1/2) is required, change the 4th digit in the catalog listing to the letter D. For example, GLAA01A1A would change to GLAD01A1A for G1/2 conduit. When conduit style PG13,5 is required, change the 4th digit in the cagalog listing to the letter B. For example, GLAA01A1A would change to GLAB01A1A for PG13,5 conduit. ** Positive opening occurs. † Contacts 11-12, 13-14 operate in CCW direction. ‡ Contacts 21-22, 23-24 operate in CW direction. 6 sensing.honeywell.com MICRO SWITCH Global Limit Switches, GLA Series Table 3. MICRO SWITCH GLA Series Side Rotary Order Guide, continued 1NC/1NO Snap action 1NC/1NO Snap action Silver alloy 0,33 [2.9] 21-22 13-14 Silver alloy 0,33 [2.9] 21-22 13-14 Silver alloy 0,33 [2.9] 21-22 13-14 Silver alloy 0,33 [2.9] 21-22 13-14 1NC/1NO Slow action, MBB Silver alloy 0,33 [2.9] 21-22 13-14 11-12, 21-22 13-14, 23-24 0,33 [2.9] 11-12, 21-22 13-14, 23-24 Silver alloy 0,33 [2.9] 11-12, 21-22 13-14, 23-24 Goldplated 0,33 [2.9] 11-12, 21-22 13-14, 23-24 Silver alloy 0,33 [2.9] 11-12, 21-22 13-14, 23-24 0,33 [2.9] GLAA01A2Y – 26° 55°** 75° min. > < – GLAA01A4J GLAC01A4J 26° 55°** 1 LED (yellow) – GLFC01A4J 2 LEDs (green & yellow) GLHA01A4J – – GLAA03A4J – – GLAA04A4J – 75° min. > < – GLAA20A4J – 75° min. > < – GLAA22A4J – 1 LED (yellow) GLFA24A4J – 1 LED (yellow) – GLFC32A4J 2 LEDs (green & yellow) GLHA24A4J – – GLAA21A4J – 75° min. > < 26° 55°** 75° min. > < 26° ** 75° min. 38° 0,33 [2.9] Silver alloy – 12° Differential travel 21-22 13-14 2NC/2NO Sequen- Snap action tial 75° min. > < 12° Differential travel 0,33 [2.9] 2NC/2NO Snap action 55°** 12° Differential travel Silver alloy 2NC/2NO Snap action 26° 20 mm Conduit 12° Differential travel Slow action, BBM 2NC/2NO Snap action 0.5-14 NPT Conduit Bar Chart (degrees) ¢ contact closed £ contact open 1NC/1NO Side rotary, Silver 2NC/2NO Snap action adjustalloy able aluminum Gold2NC/2NO Snap action rod plated With LED Pilot Light/s 1NC/1NO Snap action Operating Torque max. Nm [in-lb] Contact Type 1NC/1NO Snap action Contact Material Side rotary, adjustable lever, Ø 50 mm rubber roller Contact Arrangement Head and Lever Type Catalog Listing* 75° min. 38° ** 26° 26° 55°** 12° Differential travel 26° 55°** 12° Differential travel 26° 55°** 75° min. > < 12° Differential travel 26° 55°** 75° min. > < 12° Differential travel 26° 55°** 75° min. > < 12° Differential travel 11-12 13-14 21-22 23-24 27° 42° 75° min. > < > < 8° Differential travel 8° Differential travel * Note: When conduit style G1/2 (PF1/2) is required, change the 4th digit in the catalog listing to the letter D. For example, GLAA01A1A would change to GLAD01A1A for G1/2 conduit. When conduit style PG13,5 is required, change the 4th digit in the cagalog listing to the letter B. For example, GLAA01A1A would change to GLAB01A1A for PG13,5 conduit. ** Positive opening occurs. Sensing and Internet of Things 7 MICRO SWITCH Global Limit Switches, GLA Series Table 3. MICRO SWITCH GLA Series Side Rotary Order Guide, continued Contact Material Operating Torque max. Nm [in-lb] 2NC Slow action Silver alloy 0,33 [2.9] 2NC/2NO Snap action Silver alloy 0,33 [2.9] Bar Chart (degrees) ¢ contact closed £ contact open 75° min. 26° ** 11-12 21-22 26° 11-12, 21-22 13-14, 23-24 55°** 75° min. > < With LED Pilot Light/s Contact Type Side rotary, fixed offset lever, nylon roller Contact Arrangement Head and Lever Type Catalog Listing* 0.5-14 NPT Conduit 20 mm Conduit – GLAA06A5A – – GLAA20A5A – 12° Differential travel * Note: When conduit style G1/2 (PF1/2) is required, change the 4th digit in the catalog listing to the letter D. For example, GLAA01A1A would change to GLAD01A1A for G1/2 conduit. When conduit style PG13,5 is required, change the 4th digit in the cagalog listing to the letter B. For example, GLAA01A1A would change to GLAB01A1A for PG13,5 conduit. ** Positive opening occurs. Table 4. MICRO SWITCH GLA Series Plunger Order Guide 16 [3.6] 21-22 13-14 Silver alloy 16 [3.6] 21-22 13-14 Goldplated 16 [3.6] 21-22 13-14 Slow action, BBM Silver alloy 16 [3.6] 2NC/2NO Snap action Silver alloy 16 [3.6] Silver alloy 16 [3.6] Goldplated 16 [3.6] 1NC/1NO Snap action 1NC/1NO Snap action 1NC/1NO Snap action 1NC/1NO Top pin plunger 2NC/2NO Snap action 2NC/2NO Snap action 2NC/2NO Snap action Goldplated 16 [3.6] With LED Pilot Light/s Operating Force max. N [lb] Silver alloy Contact Type Contact Material Contact Arrangement Head Type Catalog Listing* 0.5-14 NPT Conduit 20 mm Conduit – GLAA01B GLAC01B 1 LED (yellow) GLFA01B GLFC01B – – GLAC07B – GLAA03B – > < – GLAA20B GLAC20B > < 1 LED (yellow) GLFA24B – > < – GLAA22B GLAC22B 1 LED (yellow) GLFA32B – Bar Chart (millimeters) ¢ contact closed £ contact open 37.5 35 33** 30.5 > < 0.9 Differential travel 37.5 35 33** 30.5 > < 0.9 Differential travel 37.5 35 33** 30.5 > < 0.9 Differential travel 37.5 21-22 13-14 35** 30.5 > < 34 37.5 11-12, 21-22 13-14, 23-24 35 33** 30.5 0.9 Differential travel 37.5 11-12, 21-22 13-14, 23-24 35 33** 30.5 0.9 Differential travel 37.5 11-12, 21-22 13-14, 23-24 35 33** 30.5 0.9 Differential travel 37.5 11-12 13-14 21-22 23-24 35 33.8 0.8 Differential travel 0.8 Differential travel 30.5 > < > < * Note: When conduit style G1/2 (PF1/2) is required, change the 4th digit in the catalog listing to the letter D. For example, GLAA01A1A would change to GLAD01A1A for G1/2 conduit. When conduit style PG13,5 is required, change the 4th digit in the cagalog listing to the letter B. For example, GLAA01A1A would change to GLAB01A1A for PG13,5 conduit. ** Positive opening occurs. 8 sensing.honeywell.com MICRO SWITCH Global Limit Switches, GLA Series Table 5. MICRO SWITCH GLA Series Roller Plunger Order Guide 1NC/1NO 1NC/1NO 1NC/1NO 1NC/1NO Top roller plunger Snap action Snap action Snap action Snap action Silver alloy 16 [3.6] 21-22 13-14 Silver alloy 16 [3.6] 21-22 13-14 Silver alloy 16 [3.6] 21-22 13-14 Goldplated 16 [3.6] 21-22 13-14 Goldplated 16 [3.6] 21-22 13-14 50.5 GLAC01C 1 LED (yellow) GLFA01C – 2 LEDs (green & yellow) GLHA01C – – GLAA07C GLAC07C 1 LED (yellow) GLFA07C – – GLAA03B – > < – GLAA04B – 43.5 > < – GLAA06C GLAC06C > < – GLAA20C GLAC20C > < – GLAA22C – > < 1 LED (yellow) GLFA24C – > < 2 LEDs (green & yellow) – GLHC32C – GLAA21C – 43.5 > < 43.5 > < 46** 43.5 > < 48 46** 43.5 > < 0.9 Differential travel 50.5 21-22 13-14 2NC Slow action Silver alloy 16 [3.6] 50.5 11-12 21-22 2NC/2NO Snap action Silver alloy 16 [3.6] Goldplated 16 [3.6] Silver alloy 16 [3.6] Goldplated 16 [3.6] Snap action 46** 48 50.5 16 [3.6] 16 [3.6] GLAA01C 0.9 Differential travel Silver alloy Silver alloy 46** 48 50.5 Slow action, MBB 2NC/2NO Sequential – 43.5 > < 0.9 Differential travel 1NC/1NO Snap action 48 50.5 50.5 21-22 13-14 2NC/2NO 46** 0.9 Differential travel 16 [3.6] Snap action 48 50.5 Silver alloy 2NC/2NO 20 mm Conduit 0.9 Differential travel Slow action, BBM Snap action 0.5-14 NPT Conduit Bar Chart (millimeters) ¢ contact closed £ contact open 1NC/1NO 2NC/2NO With LED Pilot Light/s Snap action Operating Force max. N [lb] Contact Type 1NC/1NO Contact Material Contact Arrangement Head Type Catalog Listing* 48** 43.5 > < 47 47** 43.5 48 48** 50.5 11-12, 21-22 13-14, 23-24 48 46** 43.5 0.9 Differential travel 50.5 11-12, 21-22 13-14, 23-24 48 46** 43.5 0.9 Differential travel 50.5 11-12, 21-22 13-14, 23-24 48 46** 43.5 0.9 Differential travel 50.5 11-12, 21-22 13-14, 23-24 48 46** 43.5 0.9 Differential travel 50.5 11-12 13-14 21-22 23-24 48 45.8 43.5 > < > < 0.8 Differential travel 0.8 Differential travel * Note: When conduit style G1/2 (PF1/2) is required, change the 4th digit in the catalog listing to the letter D. For example, GLAA01A1A would change to GLAD01A1A for G1/2 conduit. When conduit style PG13,5 is required, change the 4th digit in the cagalog listing to the letter B. For example, GLAA01A1A would change to GLAB01A1A for PG13,5 conduit.. ** Positive opening occurs. Sensing and Internet of Things 9 MICRO SWITCH Global Limit Switches, GLA Series Table 6. MICRO SWITCH GLA Series Wobble Order Guide 1NC/1NO 1NC/1NO Wobble stick, 141 mm sst coil spring 1NC/1NO 1NC/1NO Snap action Snap action Snap action 0,2 [1.8] Silver alloy 0,2 [1.8] 21-22 13-14 Silver alloy 0,2 [1.8] 21-22 13-14 Silver alloy 0,2 [1.8] 21-22 13-14 Goldplated 0,2 [1.8] 21-22 13-14 21-22 13-14 21-22 13-14 > < – GLAA01E7A – 18° 35° > < – GLAA01E7B GLAC01E7B 18° 35° > < 1 LED (yellow) GLFA01E7B GLFC01E7B > < 2 LEDs (green & yellow) GLHA01E7B – > < – – GLAC07E7B > < – – – > < – GLAA20E7B GLAC20E7B > < 1 LED (yellow) GLFA24E7B – – GLAA01E7D – 8° Differential travel 18° 35° 8° Differential travel 18° 35° 8° Differential travel 0,2 [1.8] 2NC/2NO Snap action Silver alloy 0,2 [1.8] 11-12, 21-22 13-14, 23-24 Silver alloy 0,2 [1.8] 11-12, 21-22 13-14, 23-24 Silver alloy 0,2 [1.8] Snap action 35° 20 mm Conduit 8° Differential travel Silver alloy 1NC/1NO 18° 8° Differential travel Slow action, BBM Snap action 0.5-14 NPT Conduit Bar Chart (degrees) ¢ contact closed £ contact open 1NC/1NO 2NC/2NO Wobble stick, 165 mm sst wire Snap action Silver alloy With LED Pilot Light/s Snap action Operating Force max. N [lb] 1NC/1NO Contact Material Contact Type Wobble stick, 150 mm plastic rod Contact Arrangement Head Type Catalog Listing* 18° 35° 25° 18° 35° 8° Differential travel 18° 35° 8° Differential travel 21-22 13-14 18° 35° > < 8° Differential travel * Note: When conduit style G1/2 (PF1/2) is required, change the 4th digit in the catalog listing to the letter D. For example, GLAA01A1A would change to GLAD01A1A for G1/2 conduit. When conduit style PG13,5 is required, change the 4th digit in the cagalog listing to the letter B. For example, GLAA01A1A would change to GLAB01A1A for PG13,5 conduit. 10 sensing.honeywell.com MICRO SWITCH Global Limit Switches, GLA Series Table 6. MICRO SWITCH GLA Series Wobble Order Guide, continued 1NC/1NO Snap action Silver alloy 0,1 [0.9] 21-22 13-14 Silver alloy 0,1 [0.9] 21-22 13-14 Silver alloy 0,1 [0.9] Silver alloy 0,1 [0.9] Silver alloy 0,1 [0.9] With LED Pilot Light/s Snap action Operating Force max. N [lb] 1NC/1NO Contact Material Contact Type Cat whisker, 140 mm sst wire Contact Arrangement Head Type Catalog Listing* 0.5-14 NPT Conduit > < – GLAA01K8A – > < – GLAA01K8B – – GLAA20K8B GLAC20K8B – GLAA01K8C – – GLAA20K8C – Bar Chart (degrees) ¢ contact closed £ contact open 18° 20 mm Conduit 8° Differential travel 18° 8° Differential travel Cat whisker, 190 mm sst wire 2NC/2NO 1NC/1NO Snap action Snap action Cat whisker, 141 mm sst coil spring 2NC/2NO Snap action 18° 11-12, 21-22 13-14, 23-24 > < 8° Differential travel 21-22 13-14 18° > < 8° Differential travel 11-12, 21-22 13-14, 23-24 18° 8° Differential travel > < * Note: When conduit style G1/2 (PF1/2) is required, change the 4th digit in the catalog listing to the letter D. For example, GLAA01A1A would change to GLAD01A1A for G1/2 conduit. When conduit style PG13,5 is required, change the 4th digit in the cagalog listing to the letter B. For example, GLAA01A1A would change to GLAB01A1A for PG13,5 conduit. Sensing and Internet of Things 11 MICRO SWITCH Global Limit Switches, GLA Series Table 7. MICRO SWITCH GLA Series Top Roller Lever Order Guide 1NC/1NO Top roller lever Snap action Silver alloy 9,5 [2.1] 21-22 13-14 Silver alloy 9,5 [2.1] 21-22 13-14 21-22 13-14 65,2 61 56,9** 52 > < – GLAA01D GLAC01D > < 1 LED (yellow) GLFA01D – > < – GLAA04D – > < – GLAA20D GLAC20D > < – GLAA22D GLAC22D 1,7 Differential travel 65,2 61 56,9** 52 1,7 Differential travel 65,2 Slow action, MBB Silver alloy 9,5 [2.1] 2NC/2NO Snap action Silver alloy 9,5 [2.1] 11-12, 21-22 13-14, 23-24 Goldplated 9,5 [2.1] 11-12, 21-22 13-14, 23-24 Snap action 0.5-14 NPT Conduit Bar Chart (millimeters) ¢ contact closed £ contact open 1NC/1NO 2NC/2NO With LED Pilot Light/s Snap action Operating Force max. N [lb] Contact Type 1NC/1NO Contact Material Contact Arrangement Head Type Catalog Listing* 59,1** 61 65,2 61 56,9** 52 52 1,7 Differential travel 65,2 61 56,9** 1,7 Differential travel 52 20 mm Conduit * Note: When conduit style G1/2 (PF1/2) is required, change the 4th digit in the catalog listing to the letter D. For example, GLAA01A1A would change to GLAD01A1A for G1/2 conduit. When conduit style PG13,5 is required, change the 4th digit in the cagalog listing to the letter B. For example, GLAA01A1A would change to GLAB01A1A for PG13,5 conduit. ** Positive opening occurs. 12 sensing.honeywell.com MICRO SWITCH Global Limit Switches, GLA Series Table 8. MICRO SWITCH GLB Series Side Rotary Order Guide (Plug-in Body) 1NC/1NO Side rotary, fixed lever, steel roller Side rotary, adjustable lever, nylon roller Side rotary, adjustable lever, steel roller Side rotary, adjustable aluminum rod 1NC/1NO 1NC/1NO 1NC/1NO 1NC/1NO 1NC/1NO 1NC/1NO 1NC/1NO Snap action Silver alloy 0,33 [2.9] 21-22 13-14 Snap action Silver alloy 0,33 [2.9] 21-22 13-14 Snap action Silver alloy 0,33 [2.9] 21-22 13-14 Snap action Silver alloy 0,33 [2.9] 21-22 13-14 Snap action Silver alloy 0,33 [2.9] 21-22 13-14 Snap action Silver alloy 0,33 [2.9] 21-22 13-14 Snap action Silver alloy 0,33 [2.9] 21-22 13-14 Snap action Silver alloy 0,33 [2.9] 21-22 13-14 Snap action Silver alloy 0,33 [2.9] 21-22 13-14 With LED Pilot Light/s Side rotary, fixed lever, nylon roller Operating Torque max. Nm [in-lb] 1NC/1NO Contact Material Side rotary, no lever Contact Type Contact Arrangement Head Type Catalog Listing* 0.5-14 NPT Conduit 75° min. > < – GLBA02A GLBC02A 75° min. > < – GLBA02A1A – 75° min. > < – GLBA02A1B GLBC02A1B 1 LED (yellow) GLGA12A1B GLGC12A1B 75° min. > < – GLBA02A2A GLBC02A2A 75° min. > < – GLBA02A2B GLBC02A2B 1 LED (yellow) GLGA12A2B – – GLBA02A4J GLBC02A4J 1 LED (yellow) GLGA12A4J – Bar Chart (degrees) ¢ contact closed £ contact open 26° 55°** 20 mm Conduit 12° Differential travel 26° 55°** 12° Differential travel 26° 55°** 12° Differential travel 26° 55°** 75° min. > < 12° Differential travel 26° 55°** 12° Differential travel 26° 55°** 12° Differential travel 26° 55°** 75° min. > < 12° Differential travel 26° 55°** 75° min. > < 12° Differential travel 26° 55°** 12° Differential travel 75° min. > < * Note: When conduit style G1/2 (PF1/2) is required, change the 4th digit in the catalog listing to the letter D. For example, GLAA01A1A would change to GLAD01A1A for G1/2 conduit. When conduit style PG13,5 is required, change the 4th digit in the cagalog listing to the letter B. For example, GLAA01A1A would change to GLAB01A1A for PG13,5 conduit. ** Positive opening occurs. Sensing and Internet of Things 13 MICRO SWITCH Global Limit Switches, GLA Series Table 9. MICRO SWITCH GLB Series Top Plunger Order Guide (Plug-in Body) 1NC/1NO Snap action 1NC/1NO Snap action Silver alloy 16 [3.6] 21-22 13-14 Silver alloy 16 [3.6] 21-22 13-14 Silver alloy 16 [3.6] 21-22 13-14 Silver alloy 16 [3.6] 21-22 13-14 Bar Chart (millimeters) ¢ contact closed £ contact open 37.5 35 33** 30.5 > < With LED Pilot Light/s Contact Type 1NC/1NO Snap action Operating Force max. N [lb] Top roller plunger 1NC/1NO Snap action Contact Mtl Top pin plunger Contact Arrangement Head Type Catalog Listing* 0.5-14 NPT Conduit 20 mm Conduit – GLBA02B GLBC02B 1 LED (yellow) GLGA12B GLGC12B – GLBA02C GLBC02C 1 LED (yellow) GLGA12C – 0.9 Differential travel 37.5 35 33** 30.5 > < 0.9 Differential travel 37.5 35 33** 30.5 > < 0.9 Differential travel 37.5 35 33** 30.5 > < 0.9 Differential travel Table 10. MICRO SWITCH GLB Series Top Roller Lever Order Guide (Plug-in Body) Operating Force max. N [lb] 9.5 [2.1] 11-12, 21-22 13-14, 23-24 1NC/1NO Snap action Silver alloy 9.5 [2.1] 11-12, 21-22 13-14, 23-24 Top roller lever With LED Pilot Light Contact Mtl Silver alloy Contact Type 1NC/1NO Snap action Contact Arrangement Head Type Catalog Listing* 0.5-14 NPT Conduit > < – GLBA02D GLBC02D > < 1 LED (yellow) GLGA12D – Bar Chart (millimeters) ¢ contact closed £ contact open 65,2 61 56,9** 52 1,7 Differential travel 65,2 61 56,9** 1,7 Differential travel 52 20 mm Conduit * Note: When conduit style G1/2 (PF1/2) is required, change the 4th digit in the catalog listing to the letter D. For example, GLAA01A1A would change to GLAD01A1A for G1/2 conduit. When conduit style PG13,5 is required, change the 4th digit in the cagalog listing to the letter B. For example, GLAA01A1A would change to GLAB01A1A for PG13,5 conduit. ** Positive opening occurs. 14 sensing.honeywell.com MICRO SWITCH Global Limit Switches, GLA Series Table 11. MICRO SWITCH GLB Series Wobble Order Guide (Plug-in Body) 1NC/1NO Cat whisker, 141 mm sst coil spring 1NC/1NO Snap action Silver alloy 0,1 [0.9] 21-22 13-14 Snap action Silver alloy 0,1 [0.9] 21-22 13-14 Snap action Silver alloy 0,1 [0.9] 21-22 13-14 Snap action Silver alloy 0,1 [0.9] 21-22 13-14 Snap action Silver alloy 0,1 [0.9] 21-22 13-14 With LED Pilot Light/s Cat Whisker, 190 mm sst wire Operating Force max. N [lb] Wobble 1NC/1NO stick, 141 mm coil 1NC/1NO spring Contact Mtl 1NC/1NO Contact Type Wobble stick, 150 mm plastic rod Contact Arrangement Head Type Catalog Listing* 0.5-14 NPT Conduit > < – GLBA02E7A – > < – GLBA02E7B GLBC02E7B > < 1 LED (yellow) GLGA12E7B – > < – GLBA02K8B – > < – GLBA02K8C – Bar Chart (degrees) ¢ contact closed £ contact open 18° 35° 8° Differential travel 18° 35° 8° Differential travel 18° 35° 8° Differential travel 18° 35° 8° Differential travel 18° 8° Differential travel 35° 20 mm Conduit * Note: When conduit style G1/2 (PF1/2) is required, change the 4th digit in the catalog listing to the letter D. For example, GLAA01A1A would change to GLAD01A1A for G1/2 conduit. When conduit style PG13,5 is required, change the 4th digit in the cagalog listing to the letter B. For example, GLAA01A1A would change to GLAB01A1A for PG13,5 conduit.. Sensing and Internet of Things 15 MICRO SWITCH Global Limit Switches, GLA Series Product Dimensions: GLA Series Figure 2. Fixed Lever, Side Rotary Switch - Non-plug-in Body Style, GLZ51 Style Lever, and GLA Body Y ØX Z 70,00 MAX 2,756 38,1 mm 1.50 in 20,0 mm 0.79 in LEVER (catalog listing) 62,0 mm 2.44 in 7,3 mm 0.29 in 82,0 mm 3.23 in 75,8 mm 2.99 in 102,9 mm 4.05 in NYLON CONDUIT ENTRY Ø 5,3 mm Ø 0.21 in 5,3 mm 0.21 in 30,0 mm 1.18 in 31,5 mm 1.24 in 42,0 mm 1.65 in 16,0 mm 0.63 in 42,0 mm 1.65 in Figure 3. Fixed Lever, Side Rotary Switch - Plug-in Body Style, GLZ51 Style Lever, and GLB Body 6,4 mm [0.25 in] 55,9 mm [2.20 in] 50,0 mm [1.97 in] Ø 19,1 mm [Ø 0.75 in] 70,00 mm max. [2,756 in max.] 38,1 mm [1.50 in] 20,0 mm [0.79 in] 60,0 mm [2.36 in] 102,9 mm [4.05 in] 75,8 mm [2.99 in] 69,7 mm [2.74 in] 62,0 mm [2.44 in] 7,3 mm [0.29 in] Ø 5,3 mm [Ø 0.21 in] CONDUIT ENTRY 5,3 30,0 mm [1.18 in] 42,0 mm [1.65 in] 16 sensing.honeywell.com 31,5 mm [1.24 in] 41,5 mm [1.63 in] X DIM Y DIM Z DIM 19,1 .75 19,1 GLZ51B STEEL .75 24,5 GLZ51C NYLON 1.00 50,0 GLZ51Y RUBBER 1.97 STAINLESS 19.1 GLZ51T STEEL .75 GLZ51A 60,0 mm 2.36 in ROLLER MATL 16,0 mm [0.63 in] 55,9 2.20 55,9 2.20 59,1 2.33 66,1 2.60 56.8 2.24 6,4 .25 6,4 .25 12,7 .50 10,0 .39 8.8 .345 MICRO SWITCH Global Limit Switches, GLA Series Figure 4. Adjustable Lever Dimensions, GLZ52 Y Z ØX 38,1 mm to 91,5 mm adjustment 1.50 in to 3.60 in adjustment LEVER ROLLER MATL GLZ52A NYLON GLZ52B STEEL GLZ52D NYLON GLZ52E NYLON GLZ52W RUBBER GLZ52Y RUBBER X DIM Y DIM Z DIM 19,1 .75 19,1 .75 38,1 1.5 19,1 .75 40,0 1.6 50,0 1.97 65,9 2.59 65,9 2.59 65,9 2.59 79,37 3.125 71,5 2.81 68,8 2.71 6,4 .25 6,4 .25 6,4 .25 33,07 1.300 12,7 .5 10,0 .39 Figure 5. Aluminum Rod Lever Dimensions, GLZ54 6,5 mm [0.26 in] Ø 3,2 mm [Ø 0.13 in] GLZ54J: 200,0 mm [7.87 in] GLZ54K: 140,0 mm [5.51] Aluminum Rod GLZ54J: 201,5 mm [7.93 in] GLZ54K: 141,0 mm [5.56] 59,2 mm [2.33 in] Sensing and Internet of Things 17 MICRO SWITCH Global Limit Switches, GLA Series Figure 6. Pin Plunger Dimensions Figure 7. Roller Plunger Dimensions 16,0 [0.63] Ø 10,0 [Ø 0.39] 4,7 [0.19] Steel roller Ø 12,4 [Ø 0.49] 37,5 [1.48] 50,5 [1.99] Top Pin Plunger Refer to Figure 2 or 3 for other dimensions Top Roller Plunger Refer to Figure 2 or 3 for other dimensions Figure 8. Roller Lever Dimensions 7,9 [0.31] 13,0 [0.51] 14,0 [0.55] 65,2 [2.57] Ø 18,7 [Ø 0.74] 35,0 [1.38] Top Roller Lever Refer to Figure 2 or 3 for other dimensions 18 sensing.honeywell.com 16,0 [0.63] 16,0 [0.63] MICRO SWITCH Global Limit Switches, GLA Series Head Code: E • WOBBLE AND CAT WHISKER ACTUATOR DIMENSIONS Figure 10. Plastic Rod and Flexible Cable Figure 9. Coil Actuator Ø6,4 mm [Ø0.25 in] 16,0 mm [0.63 in] Plastic tip Cable Plastic 141,1 mm [5.55 in] 153,5 mm [6.04 in] 150,3 mm [5.92 in] Refer to Figure 2 or 3 for other dimensions Refer to Figure 2 or 3 for other dimensions Figure 11. Cat Whisker Wobbles 5.5 inches (stainless steel) 6.5 inches (stainless steel) 7.5 inches (stainless steel) Ø1,2 mm [Ø0.05 in] Ø1,3 mm [Ø0.05 in] Ø1,2 mm [Ø0.05 in] 190,5 mm [7.5 in] 165,1 mm [6.50 in] 139,7 mm [5.50 in] Refer to Figure 2 or 3 for other dimensions Sensing and Internet of Things 19 MICRO SWITCH Global Limit Switches, GLA Series APPLICATION INFORMATION Figure 14. Actuation Adjustment Side Rotary Assemblies The side rotary assemblies incorporate a feature for adjusting the free position of the side rotary lever. The EN 50041 body style allows infinite adjustment and reclamp. See the following diagrams for details of the mechanism in each case. Figure 12. Standard EN 50041 Body Style REPLACEMENT INSTRUCTIONS All levers for side rotary assemblies are available as replacment parts. All basics, except the plug-in, can be replaced. All EN 50041 heads can be replaced. The replacement procedures for these components are straightforward in nature. There are two lever mounting options: 1. By fully seating the lever in one of the four 90° detent positions on the shaft hub which provides positive lever retention. 2. By mounting the lever on the serrated portion of the shaft (which enables the lever to be mounted in any position). To change the rotary lever’s free position: 1. Use a 3 mm hex Allen wrench to loosen the Allen screw, as shown in Figure 13, below. 2. Back off the lever 2 mm and move it to the desired free position. 3. Retighten the Allen screw. 4. Check to see if the free position is satisfactory for the application. 5. Repeat the adjustment procedure if necessary. A teller tab located at the bottom of the lever (see diagram below) helps prevent lever slippage. It enables the installer to detect the correct tightening torque. When this tab cannot be moved, the Allen screw has been tightened properly. Figure 13. Allen Screw and Teller Tab Location EN 50041 Side Rotary Actuator Direction Adjustment As furnished, GLS rotary switches will operate when the lever is rotated from either the left or right. They can be field modified to operate in one direction only (Clockwise CW; Counter clockwise CCW) by following these steps: 1. Carefully remove the complete head assembly. 2. Turn the head assembly upside down as shown in Figure 14. 3. Pull the plunger mechanism out and rotate it through 90° increments until the alignment tab points to the desired function (CW, CCW, or CW and CCW). 4. Push plunger mechanism in. 5. Reassemble the head assembly and re-test the switch in its application. 20 sensing.honeywell.com Side Rotary Levers Remove the lever from the product being replaced. On EN 50041 product this is achieved by loosening the Allen screw holding the lever on the shaft. Replace the lever and tighten the Allen screw or combination screw. Re-test the switch in its application. Heads All EN 50041 style switch heads can be removed and replaced. 1. Remove the head by unscrewing the four retaining screws on the head assembly. 2. Ensure replacement part is identical to one being removed. 3. Re-test the assembly and ensure correct operation. Basic Switches Non-plug-in Basic switches can be removed and replaced by following this procedure: 1. Remove the cover from the body. 2. Before disconnecting the switch wiring, carefully note the wiring arrangement for your application, particularly the safety ground connection. 3. Remove the basic switch retaining screw. 4. Remove the basic switch and install the replacement basic switch. 5. Use the retaining screw to install the new basic switch – ensure that it is correctly seated in the switch body. 6. Wire the switch terminals as before. 7. Before replacing the cover – ensure that the basic switch wires are not twisted or otherwise lifted from the basic switch (to prevent them from becoming trapped when the cover is replaced). 8. Test the switch in its application. Figure 15. Retaining screw location MICRO SWITCH Global Limit Switches, GLA Series Basic Switches Plug-in EN50041 body style The switch enclosure portion of this two-piece body style plugs into a pre-wired terminal block mounted in the application. Replacement is accomplished by unplugging the old switch enclosure and plugging-in a new switch enclosure (basics are permanently staked in the switch enclosure). Figure 17. Wiring Diagram 2 LED WIRING The GLF, GLG, and GLH versions of GLS (EN 50041) come complete with LED indicators. These indicators can be wired in a variety of ways. Operation can indicate switch free or switch operated depending on the wiring arrangement employed. The table below indicates the body styles and indicators offered. Table 12. LED Series Body Function Specification GLF 1 LED 12 Æ 250 Vac and dc less than 1.5 mA draw GLG 1 LED plugin 12 Æ 250 Vac and dc less than 1.5 mA draw GLH 2 LED 18 Æ 30 Vdc 7 mA typ. current draw In Figure 17, Wiring Diagram 2, the basic switch contact is closed. The current for the LED cannot flow through the LED and the LED will not illuminate. Figure 18. Wiring Diagram 3 The following wiring diagrams show possible configurations that can be used for the LEDs. Combinations of these arrangements can be used where the dual LED versions of GLS are employed. Figure 16. Wiring Diagram 1 In Figure 18, Wiring Diagram 3, regardless of the position of the basic switch, the current for the LED can flow through the LED and the LED will illuminate indicating power available. Figure 19. Wiring Diagram 4 In Figure 16, Wiring Diagram 1, the basic switch contact is open. The current for the LED can flow through the LED (via the load) and the LED illuminates. In Figure 19, Wiring Diagram 4, when the load is energized the LED will illuminate. The above examples suggest options with these versions of GLS. The LED pilot lights should be treated as ’’for indication only’’ devices. Note: While every effort is made to ensure that the above guidelines are accurate, no responsibility can be accepted for failure to apply good engineering practice to machinery design and use of Honeywell products. Never apply any of the procedures outlined above on live circuits. Ensure that testing of changes is carried out with no risk of injury during tests. These guidelines are produced to help our customers make the right choices in applying our Limit Switches to general applications. Contact your local Honeywell representative if you have any difficulties. Sensing and Internet of Things 21 MICRO SWITCH Global Limit Switches, GLA Series REPLACEMENT PARTS - Levers REPLACEMENT PARTS - Basic Switches Rod/RollRod/ Roller er Mate- Roller Dia. Width mm rial mm [in] [in] Fixed length lever; 38,1 mm [1.5 in] radius GLZ51A Nylon 19,0 [0.75] 6,35 [0.25] GLZ51B Steel 19,0 [0.75] 6,35 [0.25] GLZ51C Nylon 25,4 [1.00] 12,7 [0.50] GLZ51E Bronze 19,0 [0.75] 6,35 [0.25] GLZ51T SST 19,0 [0.75] 9,5 [0.38] GLZ51Y Rubber 50,0 [1.97] 10,0 [0.39] Adjustable length lever; 38,1 to 89,0 mm [1.5 to 3.5 in] radius Catalog Listing GLF Body (1 LED) GLH Body (2 LEDs) 01; 1NC/1NO, snap action GLZ301 GLZ301 GLZ301 03; 1NC/1NO, slow action BBM GLZ303 GLZ303 GLZ303 04; 1NC/1NO, slow action MBB GLZ304 GLZ304 GLZ304 06; 2NC, Slow action GLZ306 GLZ306 GLZ306 07; 1NC/1NO, snap action, gold contacts GLZ307 GLZ307 GLZ307 20; 2NC/2NO, snap action GLZ320 – – Basic Switch Code GLA Body GLZ52A Nylon 19,0 [0.75] 6,35 [0.25] GLZ52B Steel 19,0 [0.75] 6,35 [0.25] 21; 2NC/2NO, snap action, sequence GLZ321 – – GLZ52D Nylon 38,1 [1.50] 6,35 [0.25] GLZ322 – – GLZ52E Nylon 19,0 [0.75] 33,1 [1.30] 22; 2NC/2NO, snap action, gold contacts GLZ52W Rubber 40.7 [1.60] 12,7 [0.50] 24; 2NC/2NO, snap action, use with LED body – GLZ324 GLZ324 GLZ52Y Rubber 50,0 [1.97] 10,0 [0.39] 26; 2NC/2NO, snap action, center neutral GLZ326 – – 32; 2NC/2NO, snap action, gold-plated contacts, use with LED body – GLZ332 GLZ332 33; 1NC/1NO, slow action BBM, gold-plated contacts GLZ333 GLZ333 GLZ333 34; 1NC/1NO, slow action, MBB, gold plated contacts GLZ334 GLZ334 GLZ334 36; 2NC, slow action, goldplated contacts GLZ336 GLZ336 GLZ336 Fixed length yoke lever; 38,1 mm [1.5in] radius GLZ53 No rollers n/a n/a GLZ53A Nylon 19,0 [0.75] 6,35 [0.25] GLZ53B Steel 19,0 [0.75] 6,35 [0.25] GLZ53E Bronze 19,0 [0.75] 6,35 [0.25] Adjustable rod levers GLZ54 Hub only n/a n/a GLZ54J Alum. rod 200 mm [7.9 in] 3,17 mm [0.125 in] n/a Alum. rod 3,17 mm 140 mm n/a [0.125 in] [5.51 in] SST rod 3,17 mm GLZ54N 318 mm n/a [0.125 in] [12.5 in] Fixed length offset lever; 38,1 mm [1.5 in] radius GLZ54K GLZ55A Nylon 19,0 [0.75] 6,35 [0.25] GLZ55B Steel 19,0 [0.75] 6,35 [0.25] GLZ55E Bronze 19,0 [0.75] 6,35 [0.25] Fixed length spring rod GLZ68 Delrin rod, 305 mm [12.0 in] 22 sensing.honeywell.com 6,35 [0.25] n/a MICRO SWITCH Global Limit Switches, GLA Series REPLACEMENT PARTS - Heads Head type GLA GLB GLF GLG GLH A; Side rotary, less lever GLZ1AA GLZ1AA GLZ1AA GLZ1AA GLZ1AA B; Top pin plunger GLZ1AB GLZ1AB GLZ1AB GLZ1AB GLZ1AB C; Top roller plunger GLZ1AC GLZ1AC GLZ1AC GLZ1AC GLZ1AC D; Top roller lever GLZ1AD GLZ1AD GLZ1AD GLZ1AD GLZ1AD E7A; Wobble plastic rod, 150 mm GLZ1AE7A GLZ1AE7A GLZ1AE7A GLZ1AE7A GLZ1AE7A E7B; Wobble sst coil spring, 141 mm GLZ1AE7B GLZ1AE7B GLZ1AE7B GLZ1AE7B GLZ1AE7B E7D; Wobble sst wire, 165 mm GLZ1AE7D GLZ1AE7D GLZ1AE7D GLZ1AE7D GLZ1AE7D K8A; Cat whisker, 140 mm sst wire GLZ1AK8A GLZ1AK8A GLZ1AK8A GLZ1AK8A GLZ1AK8A K8B; Cat whisker, 190 mm sst wire GLZ1AK8B GLZ1AK8B GLZ1AK8B GLZ1AK8B GLZ1AK8B K8C; Cat whisker, sst coil spring GLZ1AK8C GLZ1AK8C GLZ1AK8C GLZ1AK8C GLZ1AK8C Sensing and Internet of Things 23 m WARNING ADDITIONAL MATERIALS The following associated literature is available at sensing.honeywell.com: • Product range guide • Product application-specific information – Sensors and switches in front loaders – Sensors and switches in mobile cranes – Sensors and switches in oil rig applications PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. m WARNING MISUSE OF DOCUMENTATION • • The information presented in this product sheet is for reference only. Do not use this document as a product installation guide. Complete installation, operation, and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. Warranty/Remedy Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship during the applicable warranty period. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgment or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items that Honeywell, in its sole discretion, finds defective. The foregoing is buyer’s sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. For more information Honeywell Sensing and Internet of Things services its customers through a worldwide network of sales offices and distributors. For application assistance, current specifications, pricing or the While Honeywell may provide application assistance personally, through our literature and the Honeywell web site, it is buyer’s sole responsibility to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this writing. However, Honeywell assumes no responsibility for its use. nearest Authorized Distributor, visit sensing.honeywell.com or call: Asia Pacific +65 6355-2828 Europe +44 (0) 1698 481481 USA/Canada +1-800-537-6945 Honeywell Sensing and Internet of Things 9680 Old Bailes Road Fort Mill, SC 29707 www. honeywell.com 002408-4-EN | 4 | 02/18 © 2018 Honeywell International Inc. All rights reserved.
GLAC20A1T 价格&库存

很抱歉,暂时无法提供与“GLAC20A1T”相匹配的价格&库存,您可以联系我们找货

免费人工找货