Honeywell ZephyrTM Digital Airflow Sensors
HAF Series—High Accuracy: 10 SLPM, 15 SLPM, 20 SLPM,
50 SLPM, 100 SLPM, 200 SLPM, 300 SLPM
008268
Issue 5
Datasheet
DESCRIPTION
Honeywell Zephyr™ HAF Series sensors provide a digital
interface for reading airflow over specified full-scale flow and
compensated temperature ranges. The thermally isolated
heater and temperature sensing elements help these sensors
provide a fast response to air or gas flow. Zephyr sensors are
designed to measure mass flow of air and other non-corrosive
gases. Standard flow ranges are 10 SLPM, 15 SLPM, 20
SLPM, 50 SLPM, 100 SLPM, 200 SLPM and 300 SLPM,
with custom flow ranges available. The sensors are fully
calibrated and temperature compensated with an onboard
Application Specific Integrated Circuit (ASIC). The HAF Series
>10 SLPM is compensated over the calibrated temperature
range of 0°C to 50°C [32°F to 122°F]. The state-of-the-art
ASIC-based compensation provides digital (I2C) outputs with
a response time of 1 ms. These sensors operate on the heat
transfer principle to measure mass airflow. They consist of
a microbridge Microelectronic and Microelectromechanical
System (MEMS) with temperature-sensitive resistors
deposited with thin films of platinum and silicon nitride.
The MEMS sensing die is located in a precise and carefully
designed airflow channel to provide repeatable response to
flow. Zephyr sensors provide the customer with enhanced
reliability, high accuracy, repeatable measurements and the
ability to customize sensor options to meet many specific
application needs. The combination of rugged housings with
a stable substrate makes these products extremely robust.
They are designed and manufactured according to ISO 9001
standards.
VALUE TO CUSTOMERS
• Precise measurement: The industry’s smallest Total Error
Band, fast response time, and high accuracy provide precise
measurement and high performance in the customer’s
application.
• Saves time: Configurable and customizable with a choice of
port styles simplifies design and reduces production time.
• Cost-effective: Reduces printed circuit board (PCB) size and
overall design and production costs.
Sensing and Internet of Things
FEATURES
• Fast response time (1 ms) allows the customer’s application
to respond quickly to a change in airflow, important in
critical medical (e.g., anesthesia) and industrial (e.g., fume
hood) applications.
• High stability reduces errors due to thermal effects and
null shift, providing accurate readings over time and often
eliminating the need for system calibration after PCB mount
and periodically over time.
• High sensitivity at very low flows provides a fast response
time at the onset or cessation of flow.
• High 12-bit resolution increases the ability to sense small
airflow changes, allowing customers to more precisely
control their application.
• Wide airflow range: The industry’s broadest airflow range
measures mass flow with standard flow ranges of 0 to10,
0 to 15, 0 to 20, 0 to 50, 0 to 100, 0 to 200 and 0 SLPM to
300 SLPM, or custom flow ranges, increasing the options to
integrate the sensor into the application.
• Choice of port styles: Manifold mount, 22 mm OD tapered
male fitting, and G 3/8 female threaded fitting provide
flexibility to choose the pneumatic connection that is best
for the customer’s application.
• Linear output provides a more intuitive sensor signal than
the raw output of basic airflow sensors, which can help
reduce production costs, design, and implementation time.
• Wide supply voltage range (3 Vdc to 10 Vdc) provides a
flexible regulated power circuit which allows the designer the
flexibility to choose the supply voltage that works best in the
system.
• ASIC-based I2C digital output simplifies integration
to microprocessors or microcontrollers, reducing PCB
complexity and component count.
• RoHS-compliant materials Meet Directive 2002/95/EC.
POTENTIAL APPLICATIONS
• Medical: Anesthesia delivery machines, ventilators,
ventricular assist devices (heart pumps), spirometers,
laparoscopy
• Industrial: Analytic instrumentation (spectrometry,
chromatrography), air-to-fuel ratio, fuel cells, fume hoods,
gas leak detection, process control gas monitoring, vacuum
pump monitoring
PORTFOLIO
The Honeywell Zephyr Digital Airflow Sensors join an
extensive line of airflow sensors for potential use in medical,
industrial, and consumer applications.
Honeywell ZephyrTM Digital Airflow Sensors
HAF Series—High Accuracy: 10, 15, 20, 50, 100, 200, 300 SLPM
Figure 1. Total Error Band vs. Accuracy
Other airflow sensor manufacturers only report on accuracy, while Honeywell reports Total Error Band.
Sources of Error
Offset
Full Scale Span
Pressure Non-Linearity
Accuracy
BFSL
Pressure Hysteresis
Pressure Non-Repeatability
Thermal Effect on Offset
Total
Error
Band
Thermal Effect on Span
Thermal Hysteresis
HIGH ACCURACY
TOTAL ERROR BAND (TEB)*
Ideal for use in demanding applications that require high
Honeywell specifies TEB, the most comprehensive, clear,
accuracy.
and meaningful measurement that provides the sensor’s
– 0%FS to 14.3%FS = 0.5%FS
true accuracy (see Figure 1). TEB allows for precise airflow
– 14.3%FS to 100%FS = 3.5%reading
measurement, often ideal for demanding applications with high
accuracy requirements for precise airflow measurement.
• 10, 15, 20, 50, 100, 200 SLPM:
– 0%FS to 12.5%FS = 0.5%FS
– 12.5%FS to 100%FS = 4.0%reading
• 300 SLPM only:
– 0%FS to 12.5%FS = 0.5%FS
– 12.5%FS to 66.7%FS = 4.0%reading
– 66.7%FS to 100%FS = 7.0%reading
Table 1. Absolute Maximum Ratings
1
Characteristic
Parameter
Supply voltage
-0.3 Vdc to 11.0 Vdc
Voltage on digital I/O output pins
-0.3 Vdc to 3.0 Vdc2
Storage temperature range
-40°C to 100°C [-40°F to 212°F]
Maximum flow change
10,000 SLPM/s
Maximum common mode pressure
4 bar | 60 psi at 25°C [77°F]
Maximum flow
350 SLPM
Absolute maximum ratings are the extreme limits that the device will withstand without damage to the device. However, the electrical and
mechanical characteristics are not guaranteed as the maximum limits (above recommended operating conditions) are approached, nor will
the device necessarily operate at absolute maximum ratings.
1
Digital I/O pins are diode protected at this voltage up to 2 mA. Digital bus voltage may exceed this value if the maximum digital bus current is
limited to 2 mA or less. The maximum bus current is generally determined by the bus pull-up resistors
2
CAUTION
CAUTION
Do not use these products to sense liquid flow.
Failure to comply with these instructions may result in
product damage.
Do not dissamble these products.
Failure to comply with these instructions may result in
product damage.
IMPROPER USE
2
Sensing and Internet of Things
PRODUCT DAMAGE
Honeywell ZephyrTM Digital Airflow Sensors
HAF Series—High Accuracy: 10, 15, 20, 50, 100, 200, 300 SLPM
Table 2. Operating Specifications
Characteristic
Parameter
Supply voltage
3 Vdc to 10 Vdc
Supply current
Power:
3 Vdc
10 Vdc
Calibrated temperature range1
20 mA max.
Operating temperature range
-20°C to 70°C [-4°F to 158°F]
Full scale (FS) flow
10, 15, 20, 50, 100, 200, 300 SLPM
2
60 mW max.
200 mW max.
0°C to 50°C [32°F to 122°F]
Calilbrated flow range
0 to 10, 0 to 15, 0 to 20, 0 to 50, 0 to 100, 0 to 200, 0 SLPM to 300 SLPM
Calibration gas
Accuracy3
0%FS to 14.3%FS
14.3%FS to 100%FS
clean, dry air
Total Error Band:4
10, 15, 20, 50, 100, 200 SLPM:
0%FS to 12.5%FS
12.5%FS to 100%FS
300 SLPM only:
0%FS to 12.5%FS
12.5%FS to 66.7%FS
66.7%FS to 100%FS
0.5%FS
3.5%reading
0.5%FS
4.0%reading
0.5%FS
4.0%reading
7.0%reading
Null accuracy5
±0.5%FS
Flow response time 6
1 ms
Warm up time
Resolution:
10 SLPM
15 SLPM
20 SLPM
50 SLPM
100 SLPM
200 SLPM
300 SLPM
35 ms
Proof pressure
10.3 bar | 150 psig
Burst pressure
13.7 bar | 200 psig
Bus standards
I2C fast mode (up to 400 kHz)
7
0.002 SLPM
0.003 SLPM
0.003 SLPM
0.008 SLPM
0.015 SLPM
0.029 SLPM
0.043 SLPM
8
Reverse polarity protection
no
Custom and extended temperature compensated ranges are possible. Contact Honeywell for details.
2
Honeywell standard for mass flow rate units is SLPM, which has reference conditions of 0°C and 1 atm. Custom units are given as LPM with listed
reference conditions at the first mention.
3
Accuracy is the maximum deviation in output from nominal over the entire calibrated flow range at 25ºC. Errors include Offset, Full Scale Span,
Linearity, Flow Hysteresis, and Repeatability.
4
Total Error Band (TEB) is the maximum deviation in output from nominal over the entire calibrated flow range and temperature range. Total Error
Band includes all Accuracy errors, as well as all temperature effects over the compensated temperature range, including Temperature Offset,
Temperature Span and Thermal Hysteresis.
5
Null Accuracy is the maximum deviation in output from nominal at null flow over the entire calibrated temperature range.
6
Response time: time to electrically respond to any mass flow change at the microbridge airflow transducer (response time of the transducer may be
affected by the pneumatic interface).
7
Warm-up time: time to the first valid flow measurement after power is applied.
8
Refer to the Technical Note “I2C Communications with Honeywell Digital Airflow Sensors” for I2C protocol information.
1
Sensing and Internet of Things
3
Honeywell ZephyrTM Digital Airflow Sensors
HAF Series—High Accuracy: 10, 15, 20, 50, 100, 200, 300 SLPM
Table 3. Environmental Specifications
Characteristic
Parameter
Humidity
0% to 95% RH, non-condensing
Shock
30 g, 6 ms
Vibration
1,33 g at 10 Hz to 500 Hz
ESD
ESD IEC6100-4-2 air discharge up to 8 kV, or direct contact discharge up to 4 kV
Radiated immunity:
20 , 50, 100 , 200, 300 SLPM
10, 15 SLPM
Level 3 from 80 MHz to 1000 MHz per IEC61000-4-3
1 m shielded cable with 3 cm exposed leads at connector
1 m shielded cable with 3 cm exposed leads at connector and 280 Ohm at MHz ferrite bead
Table 4. Materials Specifications
Characteristic
Parameter
Wetted materials
glass reinforced (GR) thermoplastic polymer, gold, silicon, silicon dioxide, silicon nitride, epoxy,
PCB epoxy composite
Housing
GR thermoplastic polymer
Substrate
PCB
Adhesives
epoxy
Electronic components
silicon, gold
Compliance
RoHS, WEEE
Table 5. Recommended Mounting and Implementation
4
Characteristic
Parameter
Mounting screw size
10-32
Mounting screw torque
1,13 N m [20 in-lb]
Electrical connection
6 pin SIP connector
Pneumatic connection
manifold mount, 22 mm OD tapered male fitting, G 3/8 female threaded fitting
Sensing and Internet of Things
Honeywell ZephyrTM Digital Airflow Sensors
HAF Series—High Accuracy: 10, 15, 20, 50, 100, 200, 300 SLPM
Figure 2. Nomenclature and Order Guide1
For example, HAFUHM0020L4AXT defines a Honeywell ZephyrTM Airflow Sensor, unidirectional flow, long port, manifold mount, 20 SLPM, I2C output with
custom 0x49 address, 10% to 90% transfer function, 3 Vdc to 10 Vdc supply voltage.
HAF
U
HM
0020
L
4
A
X
T
Product Series
Flow Direction
Port Style
Flow Range
Unit
Output Format
Transfer
Function
Reserved for
Future Use
Supply Voltage
HAF Series—
High Accuracy
Airflow Sensor
U
Unidirectional
HM
Manifold
mount
HH
HT
1
0010
10
L
SLPM
2
Digital I2C address:
0x29
0015
15
3
Digital I2C address:
0x39
22 mm OD
tapered male
fitting per
ISO 5356
0020
20
4
Digital I2C address:
0x49
0050
50
5
Digital I2C address:
0x59
G 3/8 female
threaded
fitting per
ISO 1179
0100
100
6
Digital I2C address:
0x69
0200
200
7
Digital I2C address:
0x79
0300
300
A
10% to 90% of input
X
XXXXX
T
3 Vdc to 10 Vdc
Apart from the general configuration required, other customer-specific requirements are also possible. Please contact Honeywell.
Figure 3. All Available Standard Configurations
Manifold mount
22 mm OD tapered male fitting
G 3/8 female threaded fitting
Sensing and Internet of Things
5
Honeywell ZephyrTM Digital Airflow Sensors
HAF Series—High Accuracy: 10, 15, 20, 50, 100, 200, 300 SLPM
Figure 4. Nominal Digital Output: 10, 15, 20, 50, 100, 200, 300 SLPM
18018
16380
Digital Output (Counts)
14742
13104
11466
9828
8190
6552
4914
3276
1638
0
0
Full Scale Flow (%)
100
Figure 5. Accuracy and Total Error Band
300 SLPM only
4.00%
8.00%
3.00%
7.00%
2.00%
6.00%
1.00%
5.00%
0
TEB = 0.5%
at 43 SLPM
2.00%
-2.00%
-3.00%
0
10 20 30 40 50 60 70 80 90 100
Ideal
%FS
Accuracy:
0%FS to 14.3%FS = 0.5%
14.3%FS to 100%FS = 3.5%
Total Error Band:
0%FS to 12.5%FS = 0.5%
12.5%FS to 100%FS = 4.0%
TEB = 7.00%
at 300 SLPM
TEB = 2.65%
at 200 SLPM
3.00%
-1.00%
-4.00%
TEB = 4.67%
at 200 SLPM
4.00%
Error (%FS)
Error (%FS)
10, 15, 20, 50, 100, 200 SLPM
1.00%
0
-1.00%
-2.00%
-3.00%
-4.00%
-5.00%
-6.00%
-7.00%
-8.00%
0
Ideal
10 20 30 40 50 60 70 80 90 100
%FS
Accuracy:
0%FS to 14.3%FS (0 SLPM to 43 SLPM) = 0.5%
14.3%FS to 100%FS (43 SLPM to 300 SLPM) = 3.5%
Total Error Band:
0%FS to 14.3%FS (0 SLPM to 43 SLPM) = 0.5%
14.6%FS to 66.7%FS (44 SLPM to 200 SLPM) = 4.0%
66.7%FS to 100%FS (200 SLPM to 300 SLPM) = 7.0%
6
Sensing and Internet of Things
Honeywell ZephyrTM Digital Airflow Sensors
HAF Series—High Accuracy: 10, 15, 20, 50, 100, 200, 300 SLPM
Figure 6. Flow vs Pressure Drop: 10, 15, 20, 50, 100, 200, 300 SLPM
Flow
(SLPM)
Pressure Drop (kPa)
20.684
17.237
13.790
10.342
6.895
Typical Pressure Drop
mbar
inH2O
kPa
0
0.000
0.000
0.000
1
0.103
0.042
0.010
2
0.206
0.082
0.021
4
0.396
0.159
0.040
8
0.803
0.322
0.080
10
1.027
0.412
0.103
12
1.279
0.513
0.128
14
1.549
0.621
0.155
15
1.686
0.676
0.169
16
1.820
0.730
0.182
18
2.126
0.853
0.213
20
2.444
0.980
0.244
3.447
25
3.320
1.332
0.332
0.000
50
9.314
3.736
0.931
75
17.553
3.736
1.755
100
27.979
3.736
2.798
125
40.533
3.736
4.053
150
54.881
22.017
5.488
175
71.158
28.546
7.116
200
89.506
35.907
8.951
0
50
100
150 200 250
Flow (SLPM)
300
350
225
109.363
43.873
10.936
250
131.037
52.568
13.104
275
154.389
61.936
15.439
300
179.235
71.904
17.924
Table 6. Ideal Transfer Function
Item
Digital Output Code
Flow Applied
Equation
16384 * [0.1 + 0.8 * (Flow Applied/Full Scale Flow)]
Full Scale Flow * [(Digital Output Code/16384) - 0.1]/0.8
Digital Interface
For additional details on the use of Zephyr with digital output see the Technical Note “I2C Communications with Honeywell
Digital Airflow Sensors”.
The sensor uses the I2C standard for digital communication with a slave address specified in the Nomenclature and Order Guide
in Figure 2. Following sensor power-up, each of the first two read sequences shown in Figure 7 will respond with 2 bytes of the
unique 4-byte Serial Number. The first read after power-up will respond with the two most significant bytes of the Serial Number,
while the second read will respond with the two least significant bytes of the Serial Number. For reliable performance, allow
sensor to be powered for the sensor startup time before performing the first read, then allow a 10 ms command response time
before performing the second read.
Sensing and Internet of Things
7
Honeywell ZephyrTM Digital Airflow Sensors
HAF Series—High Accuracy: 10, 15, 20, 50, 100, 200, 300 SLPM
Figure 7. Sensor I2C Read and Write Sequences
I2C Read: Slave responds to Master with data
Data Byte 0 (Most Significant)
SDA
SCL
Data Byte 1 (Least Significant)
S A6 A5 A4 A3 A2 A1 A0 1 SA D7 D6 D5 D4 D3 D2 D1 D0 MA D7 D6 D5 D4 D3 D2 D1 D0 MN S
I2C Read: Master sends data to Slave
Command Byte
SDA
SCL
S A6 A5 A4 A3 A2 A1 A0 1 SA D7 D6 D5 D4 D3 D2 D1 D0 SA S
Bit
Name
Description
S
Start condition Master pulls SDA from high to low while SCL remains high
S
Stop condition
Master allows SDA to float from low to high while SCL remains high
Address bit
I2C Slave Address is the 7 Most Significant Bits for the first transmitted byte
Read/write bit
Read = 1, Write = 0
A6
1
D7
Data bit
Read = 1, Write = 0
SA
Slave ACK
Slave pulls SDA low
MA
Master ACK
Master pulls SDA low
MN
Master NACK
Master allows SDA to float high
After the power-up read sequence described above, the sensor will respond to each I2C read request with a 16-bit (2 byte)
digital flow reading. Read requests taken faster than the Response Time (1 ms) are not guaranteed to return fresh data. The first
two bits of each flow reading will be ‘00’, while non-flow responses (such as error and status codes) will begin with ‘11’. There
are several user commands available as shown in Table 8. Following an I2C write sequence of a user command, the sensor will
respond to the next I2C read request with a 16-bit response. Possible responses to user commands can be seen in Table 9.
Table 8. User Command Descriptions
Command Byte
(Hexadecimal)
Command Name
Command Description
Command Response Time
(Max.)
0x01
GetSerialNumber
Next two read requests will each return two bytes of
the sensor’s unique 4-byte Serial Number.
10 ms
0x02
PowerOnReset
Force Power-On reset of sensor microcontroller.
20 ms
Checksum
Calculates EEPROM Checksum and compares to
production Checksum value. If the values match,
the next read request will respond with 0xCCA5.
Otherwise, the next read will respond with 0xCC90.
1s
0x03
1
Table 9. Sensor Response Descriptions
Sensor Response
(Hexadecimal)
Response Name
Response Description
0xCCA5
POSACK
non-response command was executed successfully
0xCC99
BadCommand
command byte was not recognized
0xCC9A
BadParam
command sent with incorrect parameter bytes
0xCC9B
Failure
command failed during execution
0xCC90
BadChecksum
checksum did not match stored value
0xCCBB
Busy
sensor is busy calculating the checksum value
The maximum sink current on SCL or SDA is 2 mA. Therefore, if the pull-up resistors are biased by VDD, and if VDD reaches
the maximum supply voltage of 6 V, then the pull-up resistors for SCL and SDA must be greater than 3.0 kOhm to limit the sink
current to 2 mA. The typical value for SCL and SDA pull-up resistors is 4.7 kOhm (this value depends on the bus capacitance and
the bus speed).
8
Sensing and Internet of Things
Honeywell ZephyrTM Digital Airflow Sensors
HAF Series—High Accuracy: 10, 15, 20, 50, 100, 200, 300 SLPM
Figure 8. Mounting Dimensions (For reference only: mm [in].)
Port Style: Manifold Mount
8
[0.3]
Mounting Footprint
71,2
[2.80]
55,2
[2.17]
16,0
[0.63]
30,0
[1.2]
14,6
[0.58]
71,2
[2.80]
55,2
[2.17]
4X 5,60
[0.220]
30,6
[1.20]
4X 5,20
[0.205]
A
A
22,0
[0.87]
54,4
[2.14]
14,5
[0.57]
4X 15,0
[0.59]
16,0
[0.63]
44,0
33,0 [1.73]
[1.30]
54,4
[2.14]
44,0
[1.73]
8
[0.3]
B
63,2
[2.49]
4,0
[0.16]
51,5
[2.03]
D
54
[2.1]
34,5
[1.36]
33
[1.3]
4X 4,50
[0.177]
42,4
[1.67]
22,0
[0.87]
4,0
[0.16]
2X 13,0 DIA.
[0.51]
87
[3.4]
A
Pin 1.
B
4X 10-32 pan head screws 1,13 N m [20 in-lb] torque.
C
2X Gland for O-Ring AS568-113, 13,94 mm ID x 2,62 mm
[0.549 in ID x 0.103 in W. Two O-rings, AS568A-113 Durometer
A65 to A80 Silicon or Viton, are required to seal sensor to
manifold. O-rings are not included.
D
Flow channel.
C
87
[3.4]
63,2
[2.49]
Port Style: 22 mm OD Tapered Male Fitting per ISO 5356
14
[0.6]
39,5
[1.56]
18,3
[0.72]
Mounting Footprint
2X 5,70
[0.22]
21,0
[0.83]
14
[0.6]
14,8
[0.58]
A
2X 5,20
[0.205]
14,5
[0.57]
39.5
[1.56]
14,8
[0.58]
A
54,4
[2.14]
14,5
[0.57]
44,0
35,1 [1.73]
[1.38]
44,0
[1.73]
54,4
[2.14]
B
2X 21,0
[0.83]
C
18,0
[0.71]
30
[1.2]
68
[2.7]
35
[1.4]
42,4
[1.67]
51,5
[2.03]
2X 4,50
[0.177]
68
[2.7]
2X 18,3
[0.72]
54
[2.1]
A
Pin 1.
B
C
2X 10-32 pan head screws 1,13 N m [20 in-lb] torque.
15 mm ID/22 mm OD tapered fitting per ISO 5356.
110
[4.3]
Sensing and Internet of Things
9
Honeywell ZephyrTM Digital Airflow Sensors
HAF Series—High Accuracy: 10, 15, 20, 50, 100, 200, 300 SLPM
Figure 8. Mounting Dimensions (For reference only: mm [in], continued.)
Port Style: G 3/8 Female Threaded Fitting per ISO 1179
16
[0.63]
39,5
[1.56]
Mounting Footprint
2X 18,3
[0.72]
2X 1,5
[0.06]
16
[0.63]
2X 5,70
[0.22]
39,5
[1.56]
14,8
[0.58]
2X 1.5
[0.06]
14,8
[0.58]
A
A
2X 5,20
[0.205]
44,0
[1.73]
14,5
[0.57]
71
[2.8]
2X 18,3
[0.72]
C
18,0
[0.71]
34,5
[1.36]
35
[1.4]
71,4
[2.81]
51,5
[2.03]
54
[2.1]
2X 4,50
[0.177]
A
Pin 1.
B
2X 10-32 pan head screws 1,13 N m [20 in-lb] torque.
C
ISO 1179 G3/8, recommended torque is 1,7 ±0,6 N m
[15 ±5 in lb]. Electrical connector part number is JST
(Japan Solderless Terminals) B6B-PH-K-S. Mating
connector part numbers are JST PHR-6 (socket) and
JST SPH-002T-P0.5L (crimp terminal).
42,4
[1.67]
Table 7. Pinout (Digital Function)
10
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
Pin 6
NC
SCL
VVDD
ground
SDA
NC
Sensing and Internet of Things
54,4
[2.14]
54,4
[2.14]
B
30,0
[1.18]
44,0
35,1 [1.73]
[1.38]
14,5
[0.57]
ADDITIONAL INFORMATION
The following associated literature is available on the
Honeywell web site at sensing.honeywell.com:
WARNING
PERSONAL INJURY
DO NOT USE these products as safety or emergency stop
devices or in any other application where failure of the
product could result in personal injury.
• Product line guide
• Product range guide
• Technical Information
– I2C Communications with Honeywell Digital Airflow
Failure to comply with these instructions could result in
death or serious injury.
Sensors
WARNING
– Gas Media Compatibility and Correction Factors
• Application Specific Information
MISUSE OF DOCUMENTATION
•
•
The information presented in this datasheet is for
reference only. Do not use this document as a product
installation guide.
Complete installation, operation, and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.
Warranty/Remedy
Honeywell warrants goods of its manufacture as being free
of defective materials and faulty workmanship during the
applicable warranty period. Honeywell’s standard product
warranty applies unless agreed to otherwise by Honeywell in
writing; please refer to your order acknowledgment or consult
your local sales office for specific warranty details. If warranted
goods are returned to Honeywell during the period of coverage,
Honeywell will repair or replace, at its option, without charge
those items that Honeywell, in its sole discretion, finds defective.
The foregoing is buyer’s sole remedy and is in lieu of all
other warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special, or
indirect damages.
For more information
Honeywell Sensing and Internet of
Things services its customers through a
worldwide network of sales offices and
distributors. For application assistance,
current specifications, pricing or the
nearest Authorized Distributor, visit
sensing.honeywell.com or call:
Asia Pacific
+65 6355-2828
Europe
+44 (0) 1698 481481
USA/Canada +1-800-537-6945
While Honeywell may provide application assistance personally,
through our literature and the Honeywell web site, it is buyer’s
sole responsibility to determine the suitability of the product in
the application.
Specifications may change without notice. The information we
supply is believed to be accurate and reliable as of this writing.
However, Honeywell assumes no responsibility for its use.
Honeywell Sensing and Internet of Things
9680 Old Bailes Road
Fort Mill, SC 29707
www.honeywell.com
008268-5-EN | 5 | 02/18
© 2018 Honeywell International Inc.