DESCRIPTION
The HIH-4000 Series delivers instrumentation-quality RH
The HIH-4000 Series Humidity Sensors are designed
(Relative Humidity) sensing performance in a competitively
specifically for high volume OEM (Original Equipment
priced, solderable SIP (Single In-line Package).
Manufacturer) users.
Available in two lead spacing configurations, the RH sensor is
Direct input to a controller or other device is made possible by
a laser trimmed, thermoset polymer capacitive sensing
this sensor’s near linear voltage output. With a typical current
element with on-chip integrated signal conditioning.
draw of only 200 µA, the HIH-4000 Series is often ideally
suited for low drain, battery operated systems.
The sensing element's multilayer construction provides
excellent resistance to most application hazards such as
Tight sensor interchangeability reduces or eliminates OEM
wetting, dust, dirt, oils and common environmental chemicals.
production calibration costs. Individual sensor calibration data
is available.
FEATURES
POTENTIAL APPLICATIONS
Molded thermoset plastic housing
Refrigeration equipment
Near linear voltage output vs % RH
HVAC (Heating, Ventilation and Air Conditioning)
Laser trimmed interchangeability
equipment
Low power design
Medical equipment
Enhanced accuracy
Drying
Fast response time
Metrology
Stable, low drift performance
Battery-powered systems
Chemically resistant
OEM assemblies
Table 1. Performance Specifications (At 5 Vdc supply and 25 ºC [77 ºF] unless otherwise noted.)
Parameter
Minimum
Typical
Maximum
Unit
Specific Note
Interchangeability (first order curve)
–
–
–
–
–
0% RH to 59% RH
-5
–
5
% RH
–
60% RH to 100% RH
-8
–
8
% RH
–
Accuracy (best fit straight line)
-3.5
–
+3.5
% RH
1
Hysterisis
–
3
–
% RH
–
Repeatability
–
±0.5
–
% RH
–
Settling time
–
–
70
ms
–
Response time (1/e in slow moving air)
–
5
–
s
–
Stability (at 50% RH)
–
1.2
–
% RH
–
Voltage supply
4
–
5.8
Vdc
2
Current supply
–
200
500
µA
–
Voltage output (1st order curve fit)
VOUT=(VSUPPLY)(0.0062(sensor RH) + 0.16), typical at 25 ºC
Temperature compensation
True RH = (Sensor RH)/(1.0546 – 0.00216T), T in ºC
Output voltage temperature, coefficient at
-4
mV/ºC
–
–
50% RH, 5 V
Operating temperature
-40[-40]
See Figure 1.
85[185]
ºC[ºF]
–
Operating humidity
0
See Figure 1.
100
% RH
3
Storage temperature
-50[-58]
125[257]
ºC[ºF]
–
–
Storage humidity
See Figure 2.
% RH
3
Specific Notes:
General Notes:
1. Can only be achieved with the supplied slope and offset.
Sensor is ratiometric to supply voltage.
For HIH-4000-003 and HIH-4000-004 catalog listings only.
Extended exposure to >90% RH causes a reversible shift
2. Device is calibrated at 5 Vdc and 25 ºC.
of 3% RH.
3. Non-condensing environment.
Sensor is light sensitive. For best performance, shield
sensor from bright light.
FACTORY CALIBRATION DATA
HIH-4000 Sensors may be ordered with a calibration and data
printout. See Table 2 and the order guide on the back page.
Table 2. Example Data Printout
Model
HIH-4000-003
Channel
92
Wafer
030996M
MRP
337313
Calculated values at 5 V
VOUT at 0% RH
VOUT at 75.3% RH
0.826 V
3.198 V
Linear output for 3.5% RH
accuracy at 25 °C
Zero offset
Slope
RH
Ratiometric response for
0% RH to 100% RH
VOUT
2
0.826 V
31.483 mV/%RH
(VOUT - zero offset)/slope
(VOUT - 0.826)/0.0315
VSUPPLY (0.1652 to 0.7952)
www.honeywell.com/sensing
Figure 1. Operating Environment (Non-condensing environment.)
100%
90%
Relative Humidity
80%
70%
60%
50%
40%
30%
20%
10%
0%
-40
-20
0
Recommended operating zone
20
40
60
80
100
80
100
Temperature ºC
Operating zone limited to
很抱歉,暂时无法提供与“HIH-4000-004”相匹配的价格&库存,您可以联系我们找货