DESCRIPTION The HIH-5030/5031 Series Low Voltage Humidity Sensors operate down to 2.7 Vdc, often ideal in battery-powered systems where the supply is a nominal 3 Vdc. The HIH-5030/5031 Series delivers instrumentation-quality RH (Relative Humidity) sensing performance in a competitively priced, solderable SMD. The HIH 5030/5031 complements our existing line of 5 Vdc SMD (Surface Mount Device) humidity sensors. SMD packaging on tape and reel allows for use in high volume, automated pick and place manufacturing, eliminating lead misalignment to printed circuit board through-holes. The HIH-5030 is a covered integrated circuit humidity sensor. The HIH-5031 is a covered, condensation-resistant, integrated circuit humidity sensor that is factory-fitted with a hydrophobic filter allowing it to be used in many condensing environments including industrial, medical and commercial applications. The HIH-5030/5031 Series Humidity Sensors are designed specifically for high volume OEM (Original Equipment Manufacturer) users. The RH sensor uses a laser trimmed, thermoset polymer capacitive sensing element with on-chip integrated signal conditioning. Direct input to a controller or other device is made possible by this sensor s near linear voltage output. With a typical current draw of only 200 A, the HIH-5030/5031 Series is ideally suited for many low drain, battery operated systems. The sensing element's multilayer construction provides excellent resistance to most application hazards such as condensation, dust, dirt, oils and common environmental chemicals. Tight sensor interchangeability reduces or eliminates OEM production calibration costs. Sample packs are available. See order guide. FEATURES Operates down to 2.7 Vdc, often ideal in battery-powered systems where the supply is a nominal 3 Vdc. Tape and reel packaging allows for use in high volume pick and place manufacturing (1,000 units per tape and reel) Molded thermoset plastic housing Near linear voltage output vs %RH Laser trimmed interchangeability Low power design Enhanced accuracy Fast response time Stable, low drift performance Chemically resistant POTENTIAL APPLICATIONS Industrial Air compressors Battery-powered systems Drying equipment HVAC (includes air conditioning, air movement, thermostats, humidifiers, de-humidifiers, humidistats, enthalpy sensing) OEM assemblies Office automation equipment Process equipment Refrigeration (includes bulk and transport systems) Telecommunications cabinets Weather stations and meteorology equipment Medical Hospital air compressors Infant incubators Microenvironments Sleep apnea equipment Treadmill stress monitoring equipment Table 1. Performance Specifications (At 3.3 Vdc supply and 25 C [77 F] unless otherwise noted.) Parameter Interchangeability (first order curve) 0% RH to 10% RH, 90% RH to 100% RH 11% RH to 89% RH Accuracy (best fit straight line) 11% RH to 89% RH Hysteresis Repeatability Settling time Response time (1/e in slow moving air) Stability (at 50% RH in 5 years) Voltage supply Current supply Voltage output (1st order curve fit) Temperature compensation Output voltage temp. coefficient at 50% RH, 3.3 V Operating temperature Operating humidity (HIH-5030) Operating humidity (HIH-5031) Storage temperature Storage humidity Minimum -7 -3 -3 www.honeywell.com/sensing Maximum Unit Specific Note % RH % RH % RH 4 2 % RH 0.5 % RH 70 ms 5 s 1.2 % RH 1 2.7 5.5 Vdc 2 200 500 A VOUT=(VSUPPLY)(0.00636(sensor RH) + 0.1515), typical at 25 C True RH = (Sensor RH)/(1.0546 0.00216T), T in C -2 mV/ C -40[-40] See Figure 2. 85[185] C[ F] 0 See Figure 2. 100 % RH 3 0 See Figure 2. 100 % RH -50[-58] 125[257] C [ F] See Figure 3. % RH 3 Specific Notes: 1. Includes stress outside of recommended operating zone. 2. Device is tested at 3.3 Vdc and 25 C. 3. Non-condensing environment. When liquid water falls on the humidity sensor die, output goes to a low rail condition indicating no humidity. 4. Total accuracy including interchangeability is 3 %RH. 2 Typical 7 3 +3 General Notes: Sensor is ratiometric to supply voltage. Extended exposure to >90 % RH causes a reversible shift of 3 % RH. Sensor is light sensitive. For best performance, shield sensor from bright light. Figure 1. Operating Environment (Non-condensing environment for HIH-5030 catalog listings only.) 100% 90% Relative Humidity 80% 70% 60% 50% 40% 30% 20% 10% 0% -40 -20 0 Recommended operating zone 20 40 60 80 100 Temperature ºC Operating zone limited to
HIH-5031-001 价格&库存

很抱歉,暂时无法提供与“HIH-5031-001”相匹配的价格&库存,您可以联系我们找货

免费人工找货