Honeywell Pressure Switches
High Pressure: HP Series, HE Series
Factory set 150 psi to 4500 psi [10,34 bar to 310,26 bar]
Low Pressure: LP Series, LE Series
Factory set or field adjustable 3.5 psi to 150 psi [0,24 bar to 10,34 bar]
Datasheet
Honeywell Pressure Switches
HP Series, HE Series, LP Series, LE Series
Honeywell Pressure Switches are durable, reliable electromechanical gauge pressure on/off switches that are available
with either single pole single throw (SPST) normally open or normally closed circuitry, or single pole double throw
(SPDT) circuitry. Their IP67 environmental sealing and high proof pressure and burst pressure ratings allow for use in
many rugged applications that require the making or breaking of an electrical connection in response to a pressure
change of the system media.
The media (gas or liquid) pressure is applied via the port of the switch to a diaphragm or sealed piston. A precompressed spring on the other side of the sealed piston or diaphragm controls the set-point pressure. If the force
resulting from the pressure is greater than the load on the spring, the electrical contacts within the switch will change
state. If the contacts are normally open when no pressure is applied, they close on increasing pressure when the
set point is reached. On decreasing pressure, the contacts will open again at a pressure somewhat less than the set
switching point. The difference between the activation point on increasing pressure and the deactivation point on
decreasing pressure is called hysteresis. The set point pressure for the switch can be configured such that the switch
will actuate on increasing or decreasing system pressure.
Features
Potential Applications
•
Life cycle rating: up to 2 million
TRANSPORTATION
•
IP67 sealing rating
•
Agricultural machinery
•
Operating temperature range: -40 °C to 120 °C
•
Heavy duty construction machinery
[-40 °F to 248 °F]
•
Heavy duty trucks
Proof pressure: 10000 psi [689 bar] (High Pressure),
•
Lawn & garden
500 psi [34,47 bar] (Low Pressure)
•
Marine vessels
Burst pressure: 20000 psi [1379 bar] (High Pressure),
•
Material handling machinery
750 psi for 3.5 psi to 22 psi, 1250 psi > 22 psi (Low Pressure)
• Railway
•
•
•
Hysteresis option (HP, HE, and LP Series only)
•
Variety of pressure ports and electrical terminations
INDUSTRIAL
•
Pressure switching set point range: Factory set 150 psi to
•
CNC machines
4500 psi [10,34 bar to 310,26 bar] (High Pressure) or factory
•
Compressors, boilers
set or field adjustable 3.5 psi to 150 psi [0,24 bar to 10,34 bar]
•
Fracking equipment
(Low Pressure)
•
Food & beverage equipment
Switching point accuracy: up to ±2 %
• Generators
•
•
HVAC/R equipment
•
Mud pumps
•
Pneumatic equipment
•
Presses and punches
•
Pressure washers
•
Trash compactors
•
Water jet cutting machines
•
Water pumps
LONG LIFE • HIGH PRODUCTIVITY • RELIABLE SWITCHING
2
sensing.honeywell.com
Honeywell Pressure Switches
Table 2. Specifications
Characteristic
Product length
(connector version AMP
Super Seal)
HP Series
HE Series
LP Series
LE Series
see page 5
see page 5
see page 6
see page 6
Product length (blade)
Product length (wire
out)
Hex size
see page 5
see page 5
see page 6
see page 6
see page 5
see page 5
see page 6
see page 6
27 mm
27 mm
27 mm
27 mm
Ease of installation
box spanner
box spanner
box spanner
box spanner
Snap-action switch
yes
yes
yes
no
Set point1 range
150 psi to 4500 psi
150 psi to 4500 psi
3.5 psi to 150 psi
3.5 psi to 150 psi
Set point ranges
6
6
4
4
Set point
accuracy @ 25 °C
(before test)
150 psi to 500 psi (±5 %)
500 psi to 4000 psi (±3.5 %)
>4000 psi (±2 % [up to 2 %])
150 psi to 1000 psi (±14%)
for 3.5 psi to 10 psi (±1 psi),
for 3.5 psi to 10 psi (±1 psi),
1000 psi to 2000 psi (±12 %) for >10 psi to 50 psi (±3 psi), for >10 psi to 50 psi (±3 psi),
2000 psi to 4000 psi (±11 %) for >50 psi to 100 psi (±7 psi), for >50 psi to 100 psi (±7 psi),
>4000 psi (±10 % [up to 10 %]) for >100 psi to 150 psi (±10 psi) for >100 psi to 150 psi (±10 psi)
Average deadband
n/a
n/a
n/a
for 3.5 psi to 10 psi (±2.8 psi),
for >10 psi to 50 psi (±14 psi),
for >50 psi to 100 psi (±38 psi),
for >100 psi to 150 psi (±40 psi)
Operating pressure2
5,000 psi max.
5,000 psi max.
250 psi max.
250 psi max.
10,000 psi
10,000 psi
500 psi
500 psi
5 % to 55 %
(based on set point range)
3 % to 65 %
(based on set point range)
3 % to 50 %
(based on set point range)
n/a
750 psi for set points
3.5 psi to 22 psi,
1250 psi for set points
> 22 psi
7.5 mA to 3 A,
24 Vdc and 250 Vac
Proof pressure
3
Hysteresis
20,000 psi
20,000 psi
5 A at 250 Vac
5 A at 24 Vdc
5 A at 250 Vac
3 A at 24 Vdc
750 psi for set points
3.5 psi to 22 psi,
1250 psi for set points
> 22 psi
7.5 mA to 5 A,
24 Vdc and 250 Vac
5 A at 115 Vac (SX rating)
3 A at 28 Vdc
n/a
1 A at 28 Vdc
n/a
Temperature rating
-40 °C to 120 °C
[-40 °F to 248 °F]
-40 °C to 85 °C
[-40 °F to 185 °F]
-40 °C to 120 °C
[-40 °F to 248 °F]
-40 °C to 120 °C
[-40 °F to 248 °F]
Media connection
multiple ports available
multiple ports available
Burst pressure
4
Current rating (resistive)
Current rating
(inductive)
Pressure ports
M14 × 1.5, M18 × 1.5, 1/2-20 UNF, 9/16-18 UNF,
3/4-16 UNF, 7/8-14 UNF
multiple ports available
multiple ports available
1/4-18 NPT,1/8-27 NPT,
1/2-20 UNF,1/8-27 PTF,
M12 × 1.5, M14 × 1.5,
9/16-18 UNF, 3/4-16 UNF,
G1/8 BSPP, 7/16-20 UNF,
R1/8 BSPT, M10 × 1.0,
R1/2 BSPT, G1/4 BSPP,
R1/4 BSPT
1/4-18 NPT,1/8-27 NPT,
1/2-20 UNF, 1/8-27 PTF,
M12 × 1.5, M14 × 1.5,
9/16-18 UNF, 3/4-16 UNF,
G1/8 BSPP, 7/16-20 UNF,
R1/8 BSPT, M10 × 1.0,
R1/2 BSPT, G1/4 BSPP,
R1/4 BSPT
sensing.honeywell.com
3
HP Series, HE Series, LP Series, LE Series
Table 2. Specifications (continued)
Characteristic
HP Series
HE Series
LP Series
LE Series
AA = Spade Terminals
BA = Screw Terminals
CA = Deutsch DT04-3P-E005 (3-Pin Connector)
DA = Amp Super Seal 1.5 - 282105-1 (3-Pin Connector)
EA = 10-inch Cable, 18 AWG (Wire Out, No Connector)
FA = 10-inch Cable w/Deutsch DT04-3P-E005 (3-Pin Connector) (16 AWG)*
GA = 10-inch Cable w/Amp Super Seal 1.5 - 282105-1 (3-Pin Connector) (18 AWG)*
HA = 10-inch Cable w/Metripack 280 Delphi 15300002 (2-Pin Connector) (18 AWG)*
JA = 10-inch Cable w/Din43650-C (3-Pin Connector) (18 AWG)*
KA = 10-inch Cable w/M12x1 (Brad Harrison Micro) - 21032121306 Harting P/N (3-Pin Connector) (18 AWG)*
LA = 10-inch Cable w/Packard Weatherpack Male Terminal - 12020827 (3-Pin Connector) (18 AWG)
MA = 10-inch Cable w/Deutsch DT04-2P-E005 (2-Pin Connector) (18 AWG)
NA = 3-inch Cable w/Packard 2P Tower Connector - 12015792 (2-Pin Connector) (18 AWG)
PA = 2.75-inch Cable w/Packard 2P Shroud Connector - 12010973 (2-Pin Connector) (18 AWG)
RA = 4-inch Cable w/Packard 2P Shroud Connector - 12010973 (2-Pin Connector) (16 AWG)
SA = 5.5-inch Cable w/ITT Cannon 2P Sure-Seal Circular Connector - SS2R-120-1804-000 (2-Pin Connector) (18 AWG)
TA = 8.5-inch Cable w/ITT Cannon 3P Sure-Seal Circular Connector - SS3R-120-8551-001 (3-Pin Connector) (16 AWG)*
UA = 10-inch Cable - Vacuum Impregnated w/Deutsch DT06-3S-EP06 (3-Socket Connector) (16 AWG)*
VA = 10-inch Cable - Vacuum Impregnated w/Deutsch DT04-3P-E005 (3-Pin Connector) (16 AWG)*
WA = 4.5-inch Cable w/Blade Terminals 6,3 mm x 0,8 mm (16 AWG)*
YA = 6-inch Cable w/Amp Super Seal 1.5 - 282104-1 (2-Pin Connector) (18 AWG)*
ZA = 10-inch Cable w/Deutsch DT06-2S-CE06 (2-Socket Connector) (18 AWG)
AB = Deutsch DT04-2P-E005 (2-Pin Connector)**
BB = 10-inch Cable w/Metripack 150 Delphi 12129615 (3-Pin Connector) (18 AWG)*
DB = 10-inch Cable w/AMP 2,5 mm System Series Connector 1-967402-1 (18 AWG)*
EB = 4.5-inch Cable w/Packard Shroud Connector 12015792 (2-Pin Connector) (18 AWG)
FB = 10-inch Cable w/Metripack 150 Delphi 12052641 (2-Pin Connector) (18 AWG)
GB = 10-inch Cable w/Deutsch Plug HD 16-3 96S (3-Pin Connector) (16 AWG)*
Termination
Circuit forms5
Life
Agency approvals
(special use switches)
Agency approvals
(other)
Field adjustability6
Spike dampening
Ingress protection
SPDT, SPST - NO/NC
SPDT, SPST - NO/NC
SPDT, SPST - NO/NC
SPDT, SPST - NO/NC
2 million
1 million
2 million
1 million
UL pending
UL pending
UL pending
UL pending
CE
CE
CE pending
CE pending
no
no
yes
yes
yes
yes
no
no
IP67
10 Hz to 2000 Hz at 15 g
20 min/sweep
500 m/sec2, 11 mSEC,
100 shocks / axis
IP67
10 Hz to 2000 Hz at 15 g
20 min/sweep
500 m/sec2, 11 mSEC,
100 shocks / axis
n/a
IP67
IP67
10 Hz to 2000 Hz at 15 g
20 min/sweep
10 Hz to 2000 Hz at 15 g
20 min/sweep
500 m/sec2, 11 mSEC
500 m/sec2, 11 mSEC
n/a
Kapton® (Teflon® coated),
Tefzel®
Kapton® (Teflon® coated),
Tefzel®
nitrile or EPDM O-ring,
steel piston
nitrile or EPDM O-ring,
steel piston
n/a
n/a
Weight
0,133 g [4.7 oz]
0,133 g [4.7 oz]
0,058 kg [2.0 oz]
0,053 kg [1.9 oz]
Contacts
silver / gold inlay
silver
gold plated
gold plated
zinc plating
zinc plating
zinc plating
zinc plating
7
Vibration resistance
Shock resistance
Wetted part
(diaphragm)
Wetted part (piston)
Product finish
Set point: Point at which switch actuates or de-actuates
2
Operating pressure: Maximum normal system operating pressure (above set point)
3
Proof pressure: Maximum pressure that the switch can handle while it maintains set point accuracy. Intermittent spikes to this level are acceptable.
4
Burst pressure: Point of complete switch failure
5
SPST: Single pole, single throw. SPDT: Single pole, double throw. NO: Normally open. NC: Normally closed.
6
Field adjustability only available with AA, BA, CA, and DA (SPST only) terminations.
7
IP00 for AA and BA terminations.
*These connectors are designed for dual circuit (SPDT) by default. They can be used for single-circuit applications (SPNC/SPNO) by making suitable connections. Refer to wiring diagram.
**Option AB is available only for LP and LE Series.
1
4
sensing.honeywell.com
Honeywell Pressure Switches
DIMENSIONS - HIGH PRESSURE: HP SERIES, HE SERIES
Figure 1. AMP Superseal 1.5
61,64 mm
[2.427 in]
Figure 6. High Pressure Port Dimensions
1/2-20 UNF
20,02 mm max.
[0.788 in] max.
27 mm hex A/F
.557
.433
.081
1/2 - 20UNF 2A
9/16-18 UNF
Female Connector Part Number (included): C-282105
Male Mating Connector (customer provided): C-282087
IP Rating: IP67
.518
Figure 2. Deutsch
27 mm hex A/F
Ø 0.432 +0.002
-0.003
(bottom view)
81,66 mm
[3.215 in]
(top view)
61,64 mm
[2.427 in]
21,16 mm max.
[0.833 in] max.
.472
.088
9/16 - 18UNF 2A
Ø 0.482 +0.002
-0.003
3/14-16 UNF
(top view)
(bottom view)
82,8 mm
[3.26 in]
Female Connector Part Number (included): DT04-3P
Male Mating Connector (customer provided): DT06-3S
IP Rating: IP67
.100
.551
3/4-16UNF 2A
Ø 0.660 +0.002
-0.003
Figure 3. Spade Terminal
27 mm hex A/F
.439
61,64 mm
[2.427 in]
7/8-14 UNF
14,43 mm
[0.568 in]
max.
.490
.500
76,08 mm
[2.995 in]
(top view)
.112
7/8-14 UNF
Ø 0.776 +0.002
-0.003
(bottom view)
M14 × 1.5
Figure 4. Screw Terminal
61,64 mm
[2.427 in]
27 mm hex A/F
12,65 mm
[0.498 in]
max.
.118
.557
.433
.098` .004
M14 X 1.5
Ø 0.461 +0.002
-0.003
Ø.740
74,3 mm
[2.925 in]
(top view)
(bottom view)
Figure 5. Cable
61,64 mm
[2.427 in]
27 mm hex A/F
M18 × 1.5
.098` .004
19,51 mm max.
[0.768 in] max.
.439
.551
.118
M18 X 1.5
Ø 0.618 +0.002
-0.003
Ø.937
(top view)
81,15 mm
[3.195 in]
(bottom view)
IP Rating: IP67
sensing.honeywell.com
5
HP Series, HE Series, LP Series, LE Series
DIMENSIONS - LOW PRESSURE: LP SERIES, LE SERIES
Figure 7. AMP Superseal 1.5
(bottom view)
Figure 13. Low Pressure Port Dimensions
H
H
58,93 mm max.
[2.32 in] max.
ØD
ØD
Female connector part number (included): C-282105
Male mating connector (customer provided): C-282087
IP rating: IP67
Figure 8. Deutsch 3-pin
H
(bottom view)
57,66 mm max.
[2.27 in] max.
Female connector part number (included): DT04-3P
Male mating connector (customer provided): DT06-3S
IP rating: IP67
Table 3. Low Pressure Port Diameters and Heights
Figure 9. Deutsch 2-pin
(bottom view)
Port
58,93 mm max.
[2.32 in] max.
Female connector part number (included): DT04-2P
Male mating connector (customer provided): DT06-2S
IP rating: IP67
Figure 10. Wire out
(bottom view)
IP rating: IP67
42,16 mm max.
[1.66 in] max.
Figure 11. Spade terminal
(bottom view)
33,02 mm max.
[1.30 in] max.
Figure 12. Screw terminal
(bottom view)
6
sensing.honeywell.com
ØD
33,02 mm max.
[1.30 in] max.
Diameter “ØD”
Height “H”
R 1/2 BSPT
21,34 mm [0.840 in]
17,09 mm [0.673 in]
R 1/4 BSPT
13,46 mm [0.530 in]
13,74 mm [0.541 in]
R 1/8 BSPT
9,96 mm [0.392 in]
10,24 mm [0.403 in]
1/8-27 PTF
10,34 mm [0.407 in]
9,24 mm [0.364 in]
1/4-18 NPT
13,72 mm [0.540 in]
17,63 mm [0.694 in]
1/8-27 NPT
10,29 mm [0.405 in]
12,497 mm [0.492 in]
G 1/4 BSPP
11,1 mm [0.437 in]
11,20 mm [0.441 in]
G 1/8 BSPP
8,28 mm [0.326 in]
7,59 mm [0.299 in]
7/16-20 UNF
9,25 mm [0.364 in]
9,09 mm [0.358 in]
9/16-18 UNF
12,24 mm [0.482 in]
10,00 mm[0.394 in]
1/2-20 UNF
10,85 mm [0.427 in]
9,09 mm [0.358 in]
M14 × 1.5
11,71 mm [0.461 in]
10,998 mm [0.433 in]
M12 × 1.5
9,70 mm [0.382 in]
10,998 mm [0.433 in]
M10 × 1.0
8,41 mm [0.331 in]
8,51 mm [0.335 in]
Honeywell Pressure Switches
NOMENCLATURE: HIGH PRESSURE
For example, HPR05500PFNSPAAA01 defines a high pressure switch, rising factory set, non-adjustable set point, 550 psi set point,
psig, sealed gage pressure unit, M14 x 1.5 port type, SPST-NO silver contacts output, cold-rolled steel base, glycol-based fluid (EPDM)
actuation/application, spade terminal connectors, standard switch, individually boxed units.
HP
R
05500
P
F
N
S
P
AA
A
01
Series
Set Point
Pressure
Set Point
Pressure
Unit
Port Type
Output
Base
Actuation/
Application
Connector
Type
Options
Packaging
Options
HP Series,
HE Series
High
Pressure
Switch
R
Rising
factory set,
non-adjustable
10,34 bar to 310,26 bar
[150 psi to 4500 psi]
P
psig,
sealed gage
C
1/2-20 UNF*
N
SPST-NO,
silver contacts
S
Cold-rolled
steel
N
Petroleum-based
hydraulic fluid
(Nitrile)
AA
1/4 in Spade
Terminals
A
Standard
switch
01 Individually
boxed units
F
Falling
factory set,
non-adjustable
NOTE:
Pressure set point
is always five digits.
B
bar,
sealed gage
F
M14 x 1.5**
C
SPST-NC,
silver contacts
V
Stainless
steel
P
Glycol-based
fluid (EPDM)
BA
Screw
Terminals
B
With 3 shrink
sleeve
packed in
15 boxes
bulk packaging
G
9/16-18 UNF**
D
SPDT-NO/NC,
silver contacts
CA
Deutsch DT04-3P-E005
(3-Pin Connector)
C
With shrink
sleeve
(plastic coating)
packed in
20 boxes
bulk packaging
H
3/4-16 UNF
H
NO, gold
inlay contacts
DA
Amp Super Seal 1.5 282105-1
(3-Pin Connector)
D
With shrink
sleeve
(acrylic coating)
25 bulk packaging
K
M18 × 1.5
J
NC, gold
inlay contacts
EA
10-inch Cable, 18 AWG
(Wire Out, No Connector)
E
With 1/8 watt
resistor
between terms.
in
50 parts
bulk packaging
N
7/8-14 UNF
K
SPDT(NO/NC),
gold inlay
contacts
FA
10-inch Cable w/Deutsch
DT04-3P-E005
(3-Pin Connector) (16 AWG)*
F
304,8 mm [12 in]
total wire length
GA
10-inch Cable w/Amp
Super Seal 1.5 - 282105-1
(3-Pin Connector) (18 AWG)*
G
With conduit
sleeve
HA
10-inch Cable w/Metripack
280 Delphi 15300002
(2-Pin Connector) (18 AWG)*
JA
10-inch Cable w/
Din43650-C
(3-Pin Connector) (18 AWG)*
KA
10-inch Cable w/M12x1
(Brad Harrison Micro) 21032121306 Harting P/N
(3-Pin Connector) (18 AWG)*
LA
10-inch Cable w/Packard
Weatherpack Male Terminal 12020827 (3-Pin Connector)
(18 AWG)
MA
10-inch Cable w/Deutsch
DT04-2P-E005
(2-Pin Connector) (18 AWG)
NA
3-inch Cable w/Packard 2P
Tower Connector 12015792 (2-Pin Connector)
(18 AWG)
PA
2.75-inch Cable w/Packard
2P Shroud Connector 12010973 (2-Pin Connector)
(18 AWG)
RA
4-inch Cable w/Packard
2P Shroud Connector 12010973 (2-Pin Connector)
(16 AWG)
SA
5.5-inch Cable w/ITT
Cannon 2P Sure-Seal
Circular Connector SS2R-120-1804-000 (2-Pin
Connector) (18 AWG)
For bar, the set point
value will be multiplied
by 100 and entered
in the listing. For example,
15,45 Bar is noted as 01545.
This allows for 2 decimal
places.
For psi, the set point
value will be multiplied
by 10 and entered
in the listing. For example,
245.5 psi is noted as 02455.
This allows for 1 decimal place.
* not applicable for
10.3 bar to 65,5 bar
[150 psi to 950 psi]
** not applicable for
10.3 bar to 24,1 bar
[150 psi to 350 psi]
TA
UA
25 individual
50 individual
25 units in
50 individual
8.5-inch Cable w/ITT
Cannon 3P Sure-Seal
Circular Connector SS3R-120-8551-001 (3-Pin
Connector) (16 AWG)*
10-inch Cable - Vacuum
Impregnated w/Deutsch
DT06-3S-EP06 (3-Socket
Connector) (16 AWG)*
VA
10-inch Cable - Vacuum
Impregnated w/Deutsch
DT04-3P-E005 (3-Pin
Connector) (16 AWG)*
WA
4.5-inch Cable w/ 1/4 in
Spade Terminals 6,3 mm x
0,8 mm (16 AWG)*
YA
6-inch Cable w/Amp
Super Seal 1.5 - 282104-1
(2-Pin Connector) (18 AWG)*
ZA
10-inch Cable w/Deutsch
DT06-2S-CE06 (2-Socket
Connector) (18 AWG)
AB
Deutsch DT04-2P-E005
(2-Pin Connector)**
BB
10-inch Cable w/Metripack
150 Delphi 12129615
(3-Pin Connector) (18 AWG)*
DB
10-inch Cable w/AMP 2,5 mm
System Series Connector
1-967402-1 (18 AWG)*
EB
4.5-inch Cable w/Packard
Shroud Connector 12015792
(2-Pin Connector) (18 AWG)
FB
10-inch Cable w/Metripack
150 Delphi 12052641
(2-Pin Connector) (18 AWG)
GB
10-inch Cable w/Deutsch
Plug HD 16-3 96S
(3-Pin Connector) (16 AWG)*
*These connectors are designed for dual circuit (SPDT) by default.
They can be used for single-circuit applications (SPNC/SPNO) by
making suitable connections. Refer to wiring diagram.
**Option AB is available only for LP and LE Series.
sensing.honeywell.com
7
HP Series, HE Series, LP Series, LE Series
NOMENCLATURE: LOW PRESSURE
For example, LPR00550PFPVKAAA01 defines a low pressure switch, rising factory set, non-adjustable set point, 55 psi set point, psig,
sealed gage pressure unit, M14 x 1.5 port type, SPST-NO gold-plated contacts output, stainless steel base, Kapton® diaphragm (Teflon®
coated), Nitrile O-ring actuation/application, spade terminal connectors, standard switch, individually boxed units.
LP
R
00550
P
F
P
V
K
AA
A
01
Series
Set Point
Pressure
Set Point
Pressure
Unit
Port Type
Output
Base
Actuation/
Application
Connector
Type
Options
Packaging
Options
LP Series,
LE Series R
Low
F
Pressure
Switch
T
C
Rising
factory set,
non-adjustable
Falling
factory set,
non-adjustable
Rising,
field
adjustable*
Falling,
field
adjustable*
* Field adjustable option is only
available for:
1. Blade and screw terminations
2. Deutsch DT04-3P
(SPDT, SPNO, SPNC)
3. Amp Superseal 1.5 (3-pin)
(SPNO & SPNC)
0,24 bar to 10,34 bar
[3.5 psi to 150 psi]
NOTE:
Pressure set point
is always five digits.
For bar, the set point
value will be multiplied
by 100 and entered
in the listing. For example,
15,45 Bar is noted as
01545. This allows for
2 decimal places.
For psi, the set point
value will be multiplied
by 10 and entered
in the listing. For example,
245.5 psi is noted as 02455.
This allows for 1 decimal place.
P
psig,
sealed gage
A
1/4-18 NPT
P
SPST-NO,
gold-plated contacts
B
Brass
B
bar,
sealed gage
B
1/8-27 NPT
M
SPST-NC,
gold-plated contacts
N
Cold-rolled
steel
M
bar,
true gage
C
1/2-20 UNF
Y
SPDT-NO/NC,
gold-plated contacts
V
Stainless
steel
T
psig,
true gage
Blade and screw electrical
terminations are available
with only the the true gage
option.
True gage option is available
only up to 20 psig set
point for integral connectors
and wire out electrical
terminations.
D
F
M14 x 1.5
AA
1/4 in Spade
Terminals
A
Standard
switch
01 Individually
boxed units
H
Kapton diaphragm
(Teflon coated),
EPDM O-ring2
BA
Screw
Terminals
B
With 3 shrink
sleeve
packed in
15 boxes
bulk packaging
T
Tefzel diaphragm,
Nitrile O-ring3
CA
Deutsch DT04-3P-E005
(3-Pin Connector)
C
With shrink
sleeve
(plastic coating)
units in
20 150
bulk packaging
DA
Amp Super Seal 1.5 282105-1
(3-Pin Connector)
D
With shrink
sleeve
(acrylic coating)
EA
10-inch Cable, 18 AWG
(Wire Out, No Connector)
E
With 1/8 watt
resistor
between terms.
FA
10-inch Cable w/Deutsch
DT04-3P-E005
(3-Pin Connector) (16 AWG)*
F
304,8 mm [12 in]
total wire length
GA
10-inch Cable w/Amp
Super Seal 1.5 - 282105-1
(3-Pin Connector) (18 AWG)*
G
With conduit
sleeve
R
With port neck
o-ring
Tefzel diaphragm,
EPDM O-ring4
Air, Petroleum-based
hydraulic fluid, engine oil
2
Glycol-based fluid
3
For high temperature
fluid media
4
For high temperature
fluid media, glycol-based
fluid
1
M12 x 1.5
Kapton diaphragm
(Teflon coated),
Nitrile O-ring1
U
1/8-27 PTF
E
K
G
9/16-18 UNF
H
3/4-16 UNF
HA
10-inch Cable w/Metripack
280 Delphi 15300002
(2-Pin Connector) (18 AWG)*
J
G1/8 BSPP
JA
10-inch Cable w/
Din43650-C
(3-Pin Connector) (18 AWG)*
M
7/16-20 UNF
KA
10-inch Cable w/M12x1
(Brad Harrison Micro) 21032121306 Harting P/N
(3-Pin Connector) (18 AWG)*
R
R1/8 BSPT
LA
T
10-inch Cable w/Packard
Weatherpack Male Terminal 12020827 (3-Pin Connector)
(18 AWG)
M10 × 1.0
V
MA
10-inch Cable w/Deutsch
DT04-2P-E005
(2-Pin Connector) (18 AWG)
R1/2 BSPT
NA
3-inch Cable w/Packard 2P
Tower Connector 12015792 (2-Pin Connector)
(18 AWG)
PA
2.75-inch Cable w/Packard
2P Shroud Connector 12010973 (2-Pin Connector)
(18 AWG)
RA
4-inch Cable w/Packard
2P Shroud Connector 12010973 (2-Pin Connector)
(16 AWG)
SA
5.5-inch Cable w/ITT
Cannon 2P Sure-Seal
Circular Connector SS2R-120-1804-000 (2-Pin
Connector) (18 AWG)
Y
G1/4 BSPP
Z
R1/4 BSPT
TA
UA
8.5-inch Cable w/ITT
Cannon 3P Sure-Seal
Circular Connector SS3R-120-8551-001 (3-Pin
Connector) (16 AWG)*
10-inch Cable - Vacuum
Impregnated w/Deutsch
DT06-3S-EP06 (3-Socket
Connector) (16 AWG)*
VA
10-inch Cable - Vacuum
Impregnated w/Deutsch
DT04-3P-E005 (3-Pin
Connector) (16 AWG)*
WA
4.5-inch Cable w/ 1/4 in
Spade Terminals 6,3 mm x
0,8 mm (16 AWG)*
YA
6-inch Cable w/Amp
Super Seal 1.5 - 282104-1
(2-Pin Connector) (18 AWG)*
ZA
10-inch Cable w/Deutsch
DT06-2S-CE06 (2-Socket
Connector) (18 AWG)
AB
Deutsch DT04-2P-E005
(2-Pin Connector)**
BB
10-inch Cable w/Metripack
150 Delphi 12129615
(3-Pin Connector) (18 AWG)*
DB
10-inch Cable w/AMP 2,5 mm
System Series Connector
1-967402-1 (18 AWG)*
EB
4.5-inch Cable w/Packard
Shroud Connector 12015792
(2-Pin Connector) (18 AWG)
FB
10-inch Cable w/Metripack
150 Delphi 12052641
(2-Pin Connector) (18 AWG)
GB
10-inch Cable w/Deutsch
Plug HD 16-3 96S
(3-Pin Connector) (16 AWG)*
*These connectors are designed for dual circuit (SPDT) by default.
They can be used for single-circuit applications (SPNC/SPNO) by
making suitable connections. Refer to wiring diagram.
**Option AB is available only for LP and LE Series.
8
sensing.honeywell.com
25 individual
Honeywell Pressure Switches
ADDITIONAL INFORMATION
The following associated literature is available on the Sensing and
Control web site at sensing.honeywell.com:
• Product installation instructions
• Product range guide
• Product application-specific information
WARNING
PERSONAL INJURY
DO NOT USE these products as safety or emergency stop
devices or in any other application where failure of the
product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.
WARNING
MISUSE OF DOCUMENTATION
•
•
The information presented in this product sheet is for
reference only. Do not use this document as a product
installation guide.
Complete installation, operation, and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.
WARRANTY/REMEDY
Honeywell warrants goods of its manufacture as being free of
defective materials and faulty workmanship. Honeywell’s standard
product warranty applies unless agreed to otherwise by Honeywell
in writing; please refer to your order acknowledgement or consult
your local sales office for specific warranty details. If warranted
goods are returned to Honeywell during the period of coverage,
Honeywell will repair or replace, at its option, without charge those
items it finds defective. The foregoing is buyer’s sole remedy
and is in lieu of all other warranties, expressed or implied,
including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.
While we provide application assistance personally, through our
literature and the Honeywell website, it is up to the customer to
determine the suitability of the product in the application.
Specifications may change without notice. The information we
supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.
sensing.honeywell.com
9
Find out more
Honeywell serves its customers
through a worldwide network
of sales offices, representatives
and distributors. For application
assistance, current specifications,
pricing or name of the nearest
Authorized Distributor, contact
your local sales office.
To learn more about Honeywell’s
sensing and control products,
call +1-815-235-6847 or
1-800-537-6945,
visit sensing.honeywell.com,
or e-mail inquiries to
info.sc@honeywell.com
Sensing and Control
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422
honeywell.com
50094081-3-EN IL50 GLO
May 2014
Copyright © 2014 Honeywell International Inc. All rights reserved.
® DuPont™, Teflon®, Tefzel®, and Kapton® are trademarks or registered trademarks of E.I. du Pont de Nemours and Company.