HSCMRNN015PDSA3

HSCMRNN015PDSA3

  • 厂商:

    HONEYWELL(霍尼韦尔)

  • 封装:

    SMD-8

  • 描述:

    BRD MNT PRESSURE SENSORS

  • 数据手册
  • 价格&库存
HSCMRNN015PDSA3 数据手册
TruStability® Board Mount Pressure Sensors HSC Series—High Accuracy, Compensated/Amplified ±1.6 mbar to ±10 bar | ±160 Pa to ±1 MPa | ±0.5 inH2O to ±150 psi Digital or Analog Output Datasheet , TruStability® Board Mount Pressure Sensors The TruStability® High Accuracy Silicon Ceramic (HSC) Series is a piezoresistive silicon pressure sensor offering a ratiometric analog or digital output for reading pressure over the specified full scale pressure span and temperature range. The HSC Series is fully calibrated and temperature compensated for sensor offset, sensitivity, temperature effects, and nonlinearity using an on-board Application Specific Integrated Circuit (ASIC). Calibrated output values for pressure are updated at approximately 1 kHz for analog and 2 kHz for digital. The HSC Series is calibrated over the temperature range of 0 °C to 50 °C [32 °F to 122 °F]. The sensor is characterized for operation from a single power supply of either 3.3 Vdc or 5.0 Vdc. These sensors measure absolute, gage, or differential pressures. The absolute versions have an internal vacuum reference and an output value proportional to absolute pressure. Gage versions are referenced to atmospheric pressure and provide an output proportional to pressure variations from atmosphere. Differential versions allow measurement of pressure between the two pressure ports. The TruStability® pressure sensors are intended for use with non-corrosive, non-ionic gases, such as air and other dry gases. Available options extend the performance of these sensors to non-corrosive, non-ionic liquids for pressure ranges above 40 mbar | 4 kPa | 20 inH2O. All products are designed and manufactured according to ISO 9001 standards. Table of Contents What makes our sensors better? Features and Benefits. . . . . . . . . . . . . . . . . . . 3-5 • Stability and reliability Potential Applications. . . . . . . . . . . . . . . . . . . . 6 • Industry-leading accuracy of ±0.25 %FSS BFSL General Specifications. . . . . . . . . . . . . . . . . . 7-8 • Port and housing options simplify integration Analog Operating Specifications. . . . . . . . . . . 9 • Wide pressure range, from ±1.6 mbar to ±10 bar | ±160 Pa to ±1 MPa | ±0.5 inH2O to ±150 psi Digital Operating Specifications. . . . . . . . . . . . 10 Transfer Function Limits. . . . . . . . . . . . . . . . . . 11 Total Error Band Values . . . . . . . . . . . . . . . . . . 12 • Small package size • Extremely low power consumption Nomenclature and Order Guide. . . . . . . . . . . . 13 Pressure Range Specifications ±1.6 mbar to ±10 bar . . . . . . . . . . . . . . . . . . . 14 ±160 Pa to ±1 MPa. . . . . . . . . . . . . . . . . . . . . 15 ±0.5 inH2O to ±150 psi. . . . . . . . . . . . . . . . . . 16 Available Standard Configurations. . . . . . . 17-18 Dimensional Drawings DIP Packages. . . . . . . . . . . . . . . . . . . . . . 19-21 SMT Packages . . . . . . . . . . . . . . . . . . . . 21-24 SIP Packages. . . . . . . . . . . . . . . . . . . . . . 24-29 Pinouts, PCB Layouts. . . . . . . . . . . . . . . . . . . 30 TruStability® Board Mount Pressure Sensors Portfolio Overview . . . . . . . . . . . . . . . . . . . . . . 31 Additional Information. . . . . . . . . . . . . . . . . . . 32 stability • accuracy • flexibility • Small size 2 sensing.honeywell.com Features and Benefits Proprietary Honeywell technology Combines high sensitivity with high overpressure and burst pressure while providing industry leading stability—performance factors that are difficult to achieve in the same product; this gives the customer more flexibility in sensor implementation and reduces the customer design requirements for protecting the sensor without sacrificing the ability to sense very small changes in pressure. PROTECTED BY MULTIPLE GLOBAL PATENTS Industry-leading long-term stability Even after long-term use and thermal extremes, the sensor’s stability remains best in class: • Minimizes system calibration needs. • Improves system performance. • Helps support system uptime by minimizing the need to service or replace the sensor during its application life. Total Error Band (TEB) Honeywell specifies TEB—the most comprehensive, clear, and meaningful measurement—that provides the sensor’s true performance over a compensated range of 0 °C to 50 °C [32 °F to 122 °F] (see Figure 1): • Minimizes individually testing and calibrating every sensor, decreasing manufacturing time and process costs. • Improves system accuracy. • Provides enhanced sensor interchangeability—there is minimal part-to-part variation in accuracy. All Possible Errors Offset + Full Scale Span + Pressure Non-Linearity + Pressure Hysteresis + = Accuracy = Total Error Band Pressure Non-Repeatability + Thermal Effect on Offset + Thermal Effect on Span + Thermal Hysteresis Figure 1. TEB Components for TruStability® Board Mount Pressure Sensors sensing.honeywell.com 3 Features and Benefits Industry-leading accuracy Extremely tight accuracy of ±0.25 %FSS BFSL (Full Scale Span Best Fit Straight Line) reduces software needed to correct system inaccuracies, minimizing system design time: • Avoids additional customer calibration. • Helps to improve system efficiency. • Often simplifies software development. High burst pressures • Promotes system reliability and reduces potential system downtime. • Can simplify the design process. High working pressure ranges Allows ultra-low pressure sensors to be used continuously well above the calibrated pressure range. Industry-leading flexibility Modular, flexible design with many package styles (with the same industryleading stability), pressure ports, and options simplify integration into the device manufacturer’s application. Wide variety of pressure ranges From ±1.6 mbar to ±10 bar | ±160 Pa to ±1 MPa | ±0.5 inH2O to 150 psi provide support for many unique applications. Meets IPC/JEDEC J-STD-020D.1 Moisture Sensitivity Level 1 requirementS • Allows the customer to avoid the thermal and mechanical damage during solder reflow attachment and/or repair that lesser rated products would incur. • Allows unlimited floor life when stored as specified (
HSCMRNN015PDSA3 价格&库存

很抱歉,暂时无法提供与“HSCMRNN015PDSA3”相匹配的价格&库存,您可以联系我们找货

免费人工找货