JV-1

JV-1

  • 厂商:

    HONEYWELL(霍尼韦尔)

  • 封装:

    -

  • 描述:

    SWITCH LEVER

  • 数据手册
  • 价格&库存
JV-1 数据手册
Model JV Digital Pressure Gauge With VCR Fittings DESCRIPTION Using VCR, the Series JV digital pressure test gauge with 0. 2% full scale accuracy uses transducer technology and a stainless steel diaphragm for high over pressure protection. The transducer technology provides enhanced accuracy over the entire pressure range. The JV has no moving parts and thus, may provide a long life with fewer re-calibrations. The stainless steel NEMA construction also provides EMI and RFI protection. The JV provides high resolution with an easy to read digital display. There are no operator errors due to interpolation of hash marks or parallax errors. The units can be scaled to read in various engineering units, such as in-Hg, ft-H20, etc. Model JVX provides a 0 Vdc to 5 Vdc output with two programmable limits and relays for process control or alarm indication. The Model JVW is powered by one or two common 9 V alkaline batteries. The Model JVT is powered by a 110 Vac adapter. The JVV, JVB, JVE, JVR, and JVX models are powered by an 11 Vdc to 32 Vdc power supply. Each unit has a membrane face with raised buttons and tactile feedback for setup and operation. The high, low, and clear buttons are easily accessible on this front membrane. Zero adjustment and zero offset/tare functions are standard on each unit. Calibration and setup parameters are stored on a memory chip to protect from loss even when power is interrupted. Unauthor- The Model JVB provides a 4 mA to 20 mA, two-wire output. The ized set ups and calibrations are also blocked with internal Model JVE provides a 0 Vdc to 5 Vdc output. The Model JVR has security. Various combinations of the front panel buttons can be two programmable limits and relays with no analog output. The deactivated. FEATURES • Passivation or oxygen-cleaned options • Two programmable limits and relays (optional) • Test gauge accuracy - 0.2 % full scale • High and low detection - Microprocessor based • Ranges to 5000 psi - gage, absolute, vacuum, or compound • 4½ digit display with 0.5 in height • Customer recalibration • Zero offset/tare • On/off switch disable feature • Optional carrying case and panel mounting rings • NEMA 4 rating (optional) • NIST traceable (optional) Model JV PERFORMANCE SPECIFICATIONS Characteristic Measure Linearity and hysteresis 0.2 % full scale (better than test gauge accuracy) Pressure range 0 psi to 1, 5, 15, 30, 50, 100, 200, 300, 500, 750, 1000, 1500, 2000, 3000, 5000, 7500, 10000 psi ADDITIONAL SPECIFICATIONS Pressure range (psi) Maximum safe over pressure (psi)1 Model JV 0 psi to 1 psi = 1 (opt) 10 0.001 0 psi to 5 psi = 5 (opt) 25 0.005 0 psi to 15 psi = 15 75 0.01 High and low capture Standard 0 psi to 30 psi = 30 150 0.02 Update speed 3 times per sec 0 psi to 50 psi = 50 250 0.05 Zero and span signal adjustment Standard: Models JVB, JVE, JVX 0 psi to 100 psi = 100 500 0.1 0 psi to 200 psi = 200 1000 0.1 0 psi to 300 psi = 300 1200 0.2 0 psi to 500 psi = 500 1500 0.5 0 psi to 750 psi = 750 1500 0.5 0 psi to 1000 psi = 1K 2000 1 0 psi to 1500 psi = 1.5K 3000 1 0 psi to 2000 psi = 2K 4000 1 0 psi to 3000 psi = 3K 6000 2 0 psi to 5000 psi = 5K 7500 5 ENVIRONMENTAL SPECIFICATIONS Characteristic Measure Temperature, operating -1 °C to 71 °C [30 °F to 160 °F] ELECTRICAL SPECIFICATIONS Characteristic Measure 0 psi to 7500 psi = 7.5K 12000 5 Rating NEMA 2 (optional NEMA 4) 0 psi to 10000 psi = 10K 15000 5 Power, Model JVW One or two 9 V alkaline batteries (included) Power, Model JVT 110 Vac adapter @ 60 Hz (included) Power, Model JVV 11 Vdc to 32 Vdc @ 100 mA (3 ft cable included) Power, Model JVB 11 Vdc to 32 Vdc (depending on loop resistance) @ 20 mA Power, Model JVE 11 Vdc to 32 Vdc @ 100 mA Power, Model JVR 11 Vdc to 32 Vdc @ 100 mA Power, Model JVX 11 Vdc to 32 Vdc @ 100 mA Electrical connection 3 ft cable (standard) on Models: JVB, JVE, JVR, JVX, JVV 1 Maximum safe overpressure is the pressure which the unit can experience occasionally without the loss of accuracy or permanent damage Mounting dimensions and characteristics MECHANICAL SPECIFICATIONS Characteristic Measure Diameter 93,98 mm [3.7 in] Display 4½ LCD digits - 12,7 mm [0.5 in] high Pressure port Size 4 stainless steel VCR (male) (Other VCR parts available. Consult factory) Wetted parts Stainless steel Case material Stainless steel Face membrane Tactile feedback raised buttons Calibration data Stored on memory chip Low battery indication Standard on Model JVW Limits and relays Models JVR and JVX 2 Honeywell • Sensing and Control For reference only Model JV Digital Pressure Gauge With VCR Fittings Order guide Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. JV W 100 G Z V ( ) * = Example SERIES JV* MODEL DESIGNATION Models with output signal B = 4 mA to 20 mA (two-wire) E = 0 Vdc to 5 Vdc R = 2 programmable limits & relays X = 0 Vdc to 5 Vdc with two limits & relays This order code is used ONLY if you want NEMA 4 rating Models with no output signal W = Battery powered (9 V alkaline)* T = 110 Vac adapter (included) V = 11 Vdc to 32 Vdc (3 ft. cable) PRESSURE RANGE (PSI) 1 5 15 30 50 = = = = = 0-1 (opt) 0-5 (opt) 0-15 0-30 0-50 100= 200= 300= 500= 750= 1K = 0-100* 0-200 0-300 0-500 0-750 0-1000 REFERENCE G A V C = = = = 1.5K = 2K = 3K = 5K = 7.5K = 10K = 0-1500 0-2000 0-3000 0-5000 0-7500 0-10000 While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Gage (std) reads zero at atmosphere* Absolute (opt) reads zero at vacuum (15 psi or higher) Vacuum (opt) scaled in In Hg (15 psi or lower) Compound (opt) reads both positive and negative (vacuum) pressure ELECTRICAL CONNECTION Z C T B = = = = No electrical connection (Model JVW - 9 V battery)* 3 foot cable ac adapter (Model JVT) Bendix (opt) (PTIH-10-6P or equal) connector sold separately Call factory for availability of other electrical connections and cable lengths. VCR PRESSURE FITTING NEMA 4 CONSTRUCTION 4 = NEMA 4 (not available on Model JVT) FIELD SELECTABLE STANDARD UNITS OF MEASURE Bar = Millibar Kilopascals Megapascals Ft H20 In H20 In Hg mmHg = = = = For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847 Email inquiries to info.sc@honeywell.com WARNING PERSONAL INJURY V = Size 4 stainless steel VCR (male)* Other VCR ports available. Please call factory. Bar = MBar kPa = MPa = Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. Feet of water Inches of water Inches of mercury mm of mercury • DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. WARNING Consult factory for other units of measure not listed MISUSE OF DOCUMENTATION NOTES 1. The limit/relay models include two LED status indicators on front face and two form C relays (normally open, common, normally closed) that are rated at a maximum 24 Vdc/Vac at 1 A or 48 Vdc/ Vac at 1/2 A. • The information presented in this catalogue is for reference only. DO NOT USE this document as product installation information. • Complete installation, operation and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. Sensing and Control Automation and Control Solutions Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 USA +1-815-235-6847 www.honeywell.com/sensing 008696-1-EN IL50 GLO  May 2008 Copyright © 2008 Honeywell International Inc. All rights reserved. Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Honeywell: JV-20 JV-26 JV-30 JV-7 JV-82 JV-1 JV-117 JV-207 JV-267 JV-311 JV-317 JV-4

很抱歉,暂时无法提供与“JV-1”相匹配的价格&库存,您可以联系我们找货

免费人工找货
JV-1
    •  国内价格 香港价格
    • 1+109.643241+13.16450
    • 5+98.537745+11.83110
    • 10+92.8908810+11.15310

    库存:19

    JV-1
      •  国内价格
      • 1+224.50109
      • 5+53.73885
      • 11+39.15511

      库存:19

      JV-1
        •  国内价格
        • 1+19.68870

        库存:50