Model JV
Digital Pressure Gauge With
VCR Fittings
DESCRIPTION
Using VCR, the Series JV digital pressure test gauge with 0. 2%
full scale accuracy uses transducer technology and a stainless
steel diaphragm for high over pressure protection. The transducer technology provides enhanced accuracy over the entire pressure range. The JV has no moving parts and thus, may provide a
long life with fewer re-calibrations.
The stainless steel NEMA construction also provides EMI and
RFI protection. The JV provides high resolution with an easy to
read digital display. There are no operator errors due to interpolation of hash marks or parallax errors. The units can be scaled
to read in various engineering units, such as in-Hg, ft-H20, etc.
Model JVX provides a 0 Vdc to 5 Vdc output with two programmable limits and relays for process control or alarm indication.
The Model JVW is powered by one or two common 9 V alkaline
batteries. The Model JVT is powered by a 110 Vac adapter. The
JVV, JVB, JVE, JVR, and JVX models are powered by an 11 Vdc
to 32 Vdc power supply.
Each unit has a membrane face with raised buttons and tactile
feedback for setup and operation. The high, low, and clear buttons are easily accessible on this front membrane. Zero adjustment and zero offset/tare functions are standard on each unit.
Calibration and setup parameters are stored on a memory chip
to protect from loss even when power is interrupted. Unauthor-
The Model JVB provides a 4 mA to 20 mA, two-wire output. The
ized set ups and calibrations are also blocked with internal
Model JVE provides a 0 Vdc to 5 Vdc output. The Model JVR has
security. Various combinations of the front panel buttons can be
two programmable limits and relays with no analog output. The
deactivated.
FEATURES
•
Passivation or oxygen-cleaned options
•
Two programmable limits and relays (optional)
•
Test gauge accuracy - 0.2 % full scale
•
High and low detection - Microprocessor based
•
Ranges to 5000 psi - gage, absolute, vacuum, or compound
•
4½ digit display with 0.5 in height
•
Customer recalibration
•
Zero offset/tare
•
On/off switch disable feature
•
Optional carrying case and panel mounting rings
•
NEMA 4 rating (optional)
•
NIST traceable (optional)
Model JV
PERFORMANCE SPECIFICATIONS
Characteristic
Measure
Linearity and hysteresis
0.2 % full scale (better than test gauge
accuracy)
Pressure range 0 psi to
1, 5, 15, 30, 50, 100, 200, 300, 500, 750,
1000, 1500, 2000, 3000, 5000, 7500,
10000 psi
ADDITIONAL SPECIFICATIONS
Pressure range (psi)
Maximum safe
over pressure
(psi)1
Model JV
0 psi to 1 psi = 1 (opt)
10
0.001
0 psi to 5 psi = 5 (opt)
25
0.005
0 psi to 15 psi = 15
75
0.01
High and low capture
Standard
0 psi to 30 psi = 30
150
0.02
Update speed
3 times per sec
0 psi to 50 psi = 50
250
0.05
Zero and span signal
adjustment
Standard: Models JVB, JVE, JVX
0 psi to 100 psi = 100
500
0.1
0 psi to 200 psi = 200
1000
0.1
0 psi to 300 psi = 300
1200
0.2
0 psi to 500 psi = 500
1500
0.5
0 psi to 750 psi = 750
1500
0.5
0 psi to 1000 psi = 1K
2000
1
0 psi to 1500 psi = 1.5K
3000
1
0 psi to 2000 psi = 2K
4000
1
0 psi to 3000 psi = 3K
6000
2
0 psi to 5000 psi = 5K
7500
5
ENVIRONMENTAL SPECIFICATIONS
Characteristic
Measure
Temperature, operating
-1 °C to 71 °C [30 °F to 160 °F]
ELECTRICAL SPECIFICATIONS
Characteristic
Measure
0 psi to 7500 psi = 7.5K
12000
5
Rating
NEMA 2 (optional NEMA 4)
0 psi to 10000 psi = 10K
15000
5
Power, Model JVW
One or two 9 V alkaline batteries (included)
Power, Model JVT
110 Vac adapter @ 60 Hz (included)
Power, Model JVV
11 Vdc to 32 Vdc @ 100 mA (3 ft cable
included)
Power, Model JVB
11 Vdc to 32 Vdc (depending on loop
resistance) @ 20 mA
Power, Model JVE
11 Vdc to 32 Vdc @ 100 mA
Power, Model JVR
11 Vdc to 32 Vdc @ 100 mA
Power, Model JVX
11 Vdc to 32 Vdc @ 100 mA
Electrical connection
3 ft cable (standard) on Models: JVB,
JVE, JVR, JVX, JVV
1
Maximum safe overpressure is the pressure which the unit can experience occasionally without the loss of accuracy or permanent damage
Mounting dimensions and characteristics
MECHANICAL SPECIFICATIONS
Characteristic
Measure
Diameter
93,98 mm [3.7 in]
Display
4½ LCD digits - 12,7 mm [0.5 in] high
Pressure port
Size 4 stainless steel VCR (male) (Other
VCR parts available. Consult factory)
Wetted parts
Stainless steel
Case material
Stainless steel
Face membrane
Tactile feedback raised buttons
Calibration data
Stored on memory chip
Low battery indication
Standard on Model JVW
Limits and relays
Models JVR and JVX
2 Honeywell • Sensing and Control
For reference only
Model JV
Digital Pressure Gauge With VCR Fittings
Order guide
Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
Honeywell’s standard product warranty applies unless agreed
to otherwise by Honeywell in writing; please refer to your
order acknowledgement or consult your local sales office for
specific warranty details. If warranted goods are returned to
Honeywell during the period of coverage, Honeywell will repair
or replace, at its option, without charge those items it finds
defective. The foregoing is buyer’s sole remedy and is in lieu
of all warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special, or
indirect damages.
JV
W 100 G
Z
V
(
)
* = Example
SERIES
JV*
MODEL DESIGNATION
Models with output signal
B = 4 mA to 20 mA (two-wire)
E = 0 Vdc to 5 Vdc
R = 2 programmable limits & relays
X = 0 Vdc to 5 Vdc with two limits & relays
This order
code is
used ONLY
if you want
NEMA 4
rating
Models with no output signal
W = Battery powered (9 V alkaline)*
T = 110 Vac adapter (included)
V = 11 Vdc to 32 Vdc (3 ft. cable)
PRESSURE RANGE (PSI)
1
5
15
30
50
=
=
=
=
=
0-1 (opt)
0-5 (opt)
0-15
0-30
0-50
100=
200=
300=
500=
750=
1K =
0-100*
0-200
0-300
0-500
0-750
0-1000
REFERENCE
G
A
V
C
=
=
=
=
1.5K =
2K =
3K =
5K =
7.5K =
10K =
0-1500
0-2000
0-3000
0-5000
0-7500
0-10000
While we provide application assistance personally, through our
literature and the Honeywell web site, it is up to the customer to
determine the suitability of the product in the application.
Gage (std) reads zero at atmosphere*
Absolute (opt) reads zero at vacuum (15 psi or higher)
Vacuum (opt) scaled in In Hg (15 psi or lower)
Compound (opt) reads both positive and negative
(vacuum) pressure
ELECTRICAL CONNECTION
Z
C
T
B
=
=
=
=
No electrical connection (Model JVW - 9 V battery)*
3 foot cable
ac adapter (Model JVT)
Bendix (opt) (PTIH-10-6P or equal) connector sold
separately
Call factory for availability of other electrical connections and cable lengths.
VCR PRESSURE FITTING
NEMA 4 CONSTRUCTION
4 = NEMA 4 (not available on Model JVT)
FIELD SELECTABLE STANDARD UNITS OF MEASURE
Bar
= Millibar
Kilopascals
Megapascals
Ft H20
In H20
In Hg
mmHg
=
=
=
=
For more information about Sensing and Control products, visit
www.honeywell.com/sensing or call +1-815-235-6847
Email inquiries to info.sc@honeywell.com
WARNING
PERSONAL INJURY
V = Size 4 stainless steel VCR (male)*
Other VCR ports available. Please call factory.
Bar =
MBar
kPa =
MPa =
Specifications may change without notice. The information we
supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.
Feet of water
Inches of water
Inches of mercury
mm of mercury
• DO NOT USE these products as safety or emergency
stop devices or in any other application where failure of
the product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.
WARNING
Consult factory for other units of measure not listed
MISUSE OF DOCUMENTATION
NOTES
1. The limit/relay models include two LED status indicators on front
face and two form C relays (normally open, common, normally
closed) that are rated at a maximum 24 Vdc/Vac at 1 A or 48 Vdc/
Vac at 1/2 A.
• The information presented in this catalogue is for
reference only. DO NOT USE this document as product
installation information.
• Complete installation, operation and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.
Sensing and Control
Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
+1-815-235-6847
www.honeywell.com/sensing
008696-1-EN IL50 GLO
May 2008
Copyright © 2008 Honeywell International Inc. All rights reserved.
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Honeywell:
JV-20 JV-26 JV-30 JV-7 JV-82 JV-1 JV-117 JV-207 JV-267 JV-311 JV-317 JV-4