MF010 Series Low
Temperature and
MF020 Series High
Temperature
Oxygen Sensors
DESCRIPTION
The MF010 Series Low Temperature Oxygen Sensors is
designed to determine the oxygen concentration in air or inert
gas mixtures with temperatures of -100 °C to 250 °C [-148 °F
to 482 °F] max. The MF020 Series High Temperature Oxygen
Sensors is designed to determine the oxygen concentration in
air or inert gas mixtures with temperatures of -100 °C to 400 °C
[-148 °F to 752 °F] max.
These products are particularly suitable for measuring oxygen
in areas that are not easily accessible, or in closed systems.
The MF010 and MF020 Series may both be supplied with a
measuring range of 0.1 vol%O2 to 25 vol%O2 and 0.1 vol%O2
to 100 vol%O2. The entire measurement range is linear for
both series.
The sensor detects the gas mixture’s oxygen partial pressure
(absolute oxygen content) by using a dynamic process that
occurs on two zirconium dioxide discs which form a
hermetically sealed chamber. Because no chemical
substances are used, the sensor exhibits significantly longer
service life than an electrochemical sensor.
The actual oxygen sensor is mounted in the tip of the bar
probe and is protected by a stainless-steel sintered disk which
serves as a flame back-flash stop. The water-proof plastic
housing accommodates the electronics and is mechanically
connected to the bar probe.
FEATURES
No moving parts
Low power consumption
No need for temperature stabilization
Functional testing and calibration in ambient air
Long life
Sensor electronics include:
1. Signal amplifier
2. Control for the ionic pump with an analog component
3. Test component
4. Internal monitoring logic component
5. Power supply for the sensor heating element and the
analog and digital components
6. Reset
7. Voltage monitor
8. Analog output
9. Bi-directional digital output
10. Internal potentiometer
The sensor outputs the measured values via an analog
channel (4 mA to 20 mA or 0 V to 10 V) and a digital channel
(also provides any error signals) which are evaluated and
further processed in a user-specified external mounting device
such as a fuel controller, display, measuring instrument,
programmable logic controller or ventilation system.
Both series may be calibrated manually or self-calibrated using
atmospheric air instead of a reference gas. The sensor can
also conduct external operational self-tests.
Both series may also operate in a fault-proof mode. The sensor
self-monitors during operation and provides error signal output.
A second oxygen sensor is not necessary.
POTENTIAL APPLICATIONS
Boiler combustion controls
Aircraft oxygen generation systems
MF010 Series and MF020 Series
Table 1. MF010 Series Specifications and Order Information
Characteristic
Catalog Listing
MF010-0-LC1
MF010-0-LC2
MF010-0-LC3
MF010-0-LC4
MF010-1-LC1
MF010-1-LC2
MF010-1-LC3
MF010-1-LC4
MF010-2-LC1
MF010-2-LC2
MF010-2-LC3
MF010-2-LC4
Temperature range at probe tip
-100 °C to 250 °C [-148 °F to 482 °F]
Output
0 Vdc to 10 Vdc
4 mA to 20 mA
O2 range (O2 partial pressure)
1 mbar to 250 mbar
1 mbar to 1000 mbar
1 mbar to 250 mbar
1 mbar to 1000 mbar
with equivalent O2 output
0.1 vol%O2 to 25 vol%O2 0.1 vol%O2 to 100 vol%O2 0.1 vol%O2 to 25 vol%O2 0.1 vol%O2 to 100 vol%O2
Probe length:
-0-LXX
220 mm [8.7 in]
400 mm [15.7 in]
-1-LXX
-2-LXX
600 mm [23.6 in]
Table 2. MF020 Series Specifications and Order Information
Characteristic
Catalog Listing
MF020-0-LC1
MF020-0-LC2
MF020-0-LC3
MF020-0-LC4
MF020-1-LC1
MF020-1-LC2
MF020-1-LC3
MF020-1-LC4
MF020-2-LC1
MF020-2-LC2
MF020-2-LC3
MF020-2-LC4
Temperature range at probe tip
-100 °C to 400 °C [-148 °F to 752 °F]
Output
0 Vdc to 10 Vdc
4 mA to 20 mA
O2 range (O2 partial pressure)
1 mbar to 250 mbar
1 mbar to 1000 mbar
1 mbar to 250 mbar
1 mbar to 1000 mbar
with equivalent O2 output
0.1 vol%O2 to 25 vol%O2 0.1 vol%O2 to 100 vol%O2 0.1 vol%O2 to 25 vol%O2 0.1 vol%O2 to 100 vol%O2
Probe length:
-0-LXX
220 mm [8.7 in]
400 mm [15.7 in]
-1-LXX
-2-LXX
600 mm [23.6 in]
Table 3. MF010 and MF020 Series General Specifications
Characteristic
Parameter
Supply voltage
24 Vdc ±5%
Supply current
500 mA
Ambient temperature (includes solar radiation
-10° C to 50° C [14 °F to 122 °F]
Resolution
12 bit
Heat-up time
approx. 10 min
Accuracy
±2% FS (Full Scale)
Reproducibility
±1% FS (Full Scale)
Gas flow rate
0 m/s to 10 m/s
Reaction time
approx. 3 s
Incidental permissible acceleration
30 g
Repetitive permissible acceleration
5g
Bar probe material
stainless steel 1.4301
Housing material
Makrolon 8030 (30% GV), UL94 V-1
Housing sealing
IP65
Connector sealing
IP67
Weight (without bar probe)
150 g [5.3 oz]
Termination (female connector)
99-4226-14-07 (Binder 693 series)
Certification
complies with EMC directives EN 50082-2 and EN 50081-1 and directives
89/336/EWG and 92/31/EWG
2
www.honeywell.com/sensing
Oxygen Sensors
Figure 1. Dimensional Drawing and Pinout (For reference only: mm/in.)
105,0
[4.13]
Varies with catalog listing.
See Table 1.)
Pin
88,0
[3.46]
27,7
[1.09]
17,5
[0.69]
21,0
[0.83]
30,0
[1.18] 35,5
[1.38] 42,5
[1.67]
1
+24 Vdc
2
0V
3
not assigned
5
Channel 1
(4 mA to 20 mA)
Ø12,0
[0.47]
Ø9,0
[0.35]
2
3
0 V or 4 mA = 0 Vol%O2
10 V or 20 mA = 25 Vol%O2
5V
0V
Channel 2 (I/O)
calibration switch
ground
7
Ø26,5
[1.04]
4
input +24 Vdc
14,0
[0.55]
21,0
[0.83]
1
7
5
4
6
60,0
[2.36]
6
42,0
[1.65]
Ø0,21
[5.3]
Figure 2. System Block Diagram
Figure 3. Sensor Mounting
Partition
Housing
Atmospheric Air
50 °C [122 °F] Max.
Gas Mixture
250 °C [482 °F] Max. (MF010)
400 °C [752 °F] Max. (MF020)
15°
MF010/MF020
Sensor
Bar Probe
Calibration
Ground
Connection Cable
Test
1 kOhm + LED
Order Guide
Catalog Listing
0V
User-Specified
External Monitoring
Device
(4 mA to 20 mA
or 0 V to 10 V
Output)
Power
Supply
24 Vdc
Partition
Bar Probe
O-Ring
Nut
Weld Socket
Description
MF010 Series
Low temperature oxygen sensor (See Table 1 for specifics.)
MF020 Series
High temperature oxygen sensor (See Table 2 for specifics.)
Honeywell Sensing and Control
3
WARNING
WARNING
PERSONAL INJURY
MISUSE OF DOCUMENTATION
DO NOT USE these products as safety or emergency stop
The information presented in this product sheet is for
devices or in any other application where failure of the
reference only. Do not use this document as a product
product could result in personal injury.
installation guide.
Failure to comply with these instructions could result in
Complete installation, operation, and maintenance
death or serious injury.
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
WARRANTY/REMEDY
Honeywell warrants goods of its manufacture as being free of
death or serious injury.
defective materials and faulty workmanship. Honeywell’s
standard product warranty applies unless agreed to otherwise
SALES AND SERVICE
by Honeywell in writing; please refer to your order
Honeywell serves its customers through a worldwide network
acknowledgement or consult your local sales office for specific
of sales offices, representatives and distributors. For
warranty details. If warranted goods are returned to Honeywell
application assistance, current specifications, pricing or name
during the period of coverage, Honeywell will repair or replace,
of the nearest Authorized Distributor, contact your local sales
at its option, without charge those items it finds defective. The
office or:
foregoing is buyer’s sole remedy and is in lieu of all other
warranties, expressed or implied, including those of
E-mail: info.sc@honeywell.com
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special,
or indirect damages.
Internet: www.honeywell.com/sensing
Phone and Fax:
While we provide application assistance personally, through
Asia Pacific
+65 6445-3033 Fax
our literature and the Honeywell web site, it is up to the
customer to determine the suitability of the product in the
+65 6355-2828
Europe
+44 (0) 1698 481481
+44 (0) 1698 481676 Fax
application.
Latin America +1-305-805-8188
Specifications may change without notice. The information we
supply is believed to be accurate and reliable as of this
printing. However, we assume no responsibility for its use.
+1-305-883-8257 Fax
USA/Canada +1-800-537-6945
+1-815-235-6847
+1-815-235-6545 Fax
Sensing and Control
Honeywell
1985 Douglas Drive North
Minneapolis, MN 55422
www.honeywell.com/sensing
000670-3-EN IL50 GLO Printed in USA
July 2011
Copyright © 2011 Honeywell International Inc. All rights reserved.
很抱歉,暂时无法提供与“MF010-2-LC4”相匹配的价格&库存,您可以联系我们找货