0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
MF010-O-LC-HT

MF010-O-LC-HT

  • 厂商:

    HONEYWELL(霍尼韦尔)

  • 封装:

  • 描述:

    SENSOR OXYGEN

  • 数据手册
  • 价格&库存
MF010-O-LC-HT 数据手册
MF010 Series Low Temperature and MF020 Series High Temperature Oxygen Sensors DESCRIPTION The MF010 Series Low Temperature Oxygen Sensors is designed to determine the oxygen concentration in air or inert gas mixtures with temperatures of -100 °C to 250 °C [-148 °F to 482 °F] max. The MF020 Series High Temperature Oxygen Sensors is designed to determine the oxygen concentration in air or inert gas mixtures with temperatures of -100 °C to 400 °C [-148 °F to 752 °F] max. These products are particularly suitable for measuring oxygen in areas that are not easily accessible, or in closed systems. The MF010 and MF020 Series may both be supplied with a measuring range of 0.1 vol%O2 to 25 vol%O2 and 0.1 vol%O2 to 100 vol%O2. The entire measurement range is linear for both series. The sensor detects the gas mixture’s oxygen partial pressure (absolute oxygen content) by using a dynamic process that occurs on two zirconium dioxide discs which form a hermetically sealed chamber. Because no chemical substances are used, the sensor exhibits significantly longer service life than an electrochemical sensor. The actual oxygen sensor is mounted in the tip of the bar probe and is protected by a stainless-steel sintered disk which serves as a flame back-flash stop. The water-proof plastic housing accommodates the electronics and is mechanically connected to the bar probe. FEATURES No moving parts Low power consumption No need for temperature stabilization Functional testing and calibration in ambient air Long life Sensor electronics include: 1. Signal amplifier 2. Control for the ionic pump with an analog component 3. Test component 4. Internal monitoring logic component 5. Power supply for the sensor heating element and the analog and digital components 6. Reset 7. Voltage monitor 8. Analog output 9. Bi-directional digital output 10. Internal potentiometer The sensor outputs the measured values via an analog channel (4 mA to 20 mA or 0 V to 10 V) and a digital channel (also provides any error signals) which are evaluated and further processed in a user-specified external mounting device such as a fuel controller, display, measuring instrument, programmable logic controller or ventilation system. Both series may be calibrated manually or self-calibrated using atmospheric air instead of a reference gas. The sensor can also conduct external operational self-tests. Both series may also operate in a fault-proof mode. The sensor self-monitors during operation and provides error signal output. A second oxygen sensor is not necessary. POTENTIAL APPLICATIONS Boiler combustion controls Aircraft oxygen generation systems MF010 Series and MF020 Series Table 1. MF010 Series Specifications and Order Information Characteristic Catalog Listing MF010-0-LC1 MF010-0-LC2 MF010-0-LC3 MF010-0-LC4 MF010-1-LC1 MF010-1-LC2 MF010-1-LC3 MF010-1-LC4 MF010-2-LC1 MF010-2-LC2 MF010-2-LC3 MF010-2-LC4 Temperature range at probe tip -100 °C to 250 °C [-148 °F to 482 °F] Output 0 Vdc to 10 Vdc 4 mA to 20 mA O2 range (O2 partial pressure) 1 mbar to 250 mbar 1 mbar to 1000 mbar 1 mbar to 250 mbar 1 mbar to 1000 mbar with equivalent O2 output 0.1 vol%O2 to 25 vol%O2 0.1 vol%O2 to 100 vol%O2 0.1 vol%O2 to 25 vol%O2 0.1 vol%O2 to 100 vol%O2 Probe length: -0-LXX 220 mm [8.7 in] 400 mm [15.7 in] -1-LXX -2-LXX 600 mm [23.6 in] Table 2. MF020 Series Specifications and Order Information Characteristic Catalog Listing MF020-0-LC1 MF020-0-LC2 MF020-0-LC3 MF020-0-LC4 MF020-1-LC1 MF020-1-LC2 MF020-1-LC3 MF020-1-LC4 MF020-2-LC1 MF020-2-LC2 MF020-2-LC3 MF020-2-LC4 Temperature range at probe tip -100 °C to 400 °C [-148 °F to 752 °F] Output 0 Vdc to 10 Vdc 4 mA to 20 mA O2 range (O2 partial pressure) 1 mbar to 250 mbar 1 mbar to 1000 mbar 1 mbar to 250 mbar 1 mbar to 1000 mbar with equivalent O2 output 0.1 vol%O2 to 25 vol%O2 0.1 vol%O2 to 100 vol%O2 0.1 vol%O2 to 25 vol%O2 0.1 vol%O2 to 100 vol%O2 Probe length: -0-LXX 220 mm [8.7 in] 400 mm [15.7 in] -1-LXX -2-LXX 600 mm [23.6 in] Table 3. MF010 and MF020 Series General Specifications Characteristic Parameter Supply voltage 24 Vdc ±5% Supply current 500 mA Ambient temperature (includes solar radiation -10° C to 50° C [14 °F to 122 °F] Resolution 12 bit Heat-up time approx. 10 min Accuracy ±2% FS (Full Scale) Reproducibility ±1% FS (Full Scale) Gas flow rate 0 m/s to 10 m/s Reaction time approx. 3 s Incidental permissible acceleration 30 g Repetitive permissible acceleration 5g Bar probe material stainless steel 1.4301 Housing material Makrolon 8030 (30% GV), UL94 V-1 Housing sealing IP65 Connector sealing IP67 Weight (without bar probe) 150 g [5.3 oz] Termination (female connector) 99-4226-14-07 (Binder 693 series) Certification complies with EMC directives EN 50082-2 and EN 50081-1 and directives 89/336/EWG and 92/31/EWG 2 www.honeywell.com/sensing Oxygen Sensors Figure 1. Dimensional Drawing and Pinout (For reference only: mm/in.) 105,0 [4.13] Varies with catalog listing. See Table 1.) Pin 88,0 [3.46] 27,7 [1.09] 17,5 [0.69] 21,0 [0.83] 30,0 [1.18] 35,5 [1.38] 42,5 [1.67] 1 +24 Vdc 2 0V 3 not assigned 5 Channel 1 (4 mA to 20 mA) Ø12,0 [0.47] Ø9,0 [0.35] 2 3 0 V or 4 mA = 0 Vol%O2 10 V or 20 mA = 25 Vol%O2 5V 0V Channel 2 (I/O) calibration switch ground 7 Ø26,5 [1.04] 4 input +24 Vdc 14,0 [0.55] 21,0 [0.83] 1 7 5 4 6 60,0 [2.36] 6 42,0 [1.65] Ø0,21 [5.3] Figure 2. System Block Diagram Figure 3. Sensor Mounting Partition Housing Atmospheric Air 50 °C [122 °F] Max. Gas Mixture 250 °C [482 °F] Max. (MF010) 400 °C [752 °F] Max. (MF020) 15° MF010/MF020 Sensor Bar Probe Calibration Ground Connection Cable Test 1 kOhm + LED Order Guide Catalog Listing 0V User-Specified External Monitoring Device (4 mA to 20 mA or 0 V to 10 V Output) Power Supply 24 Vdc Partition Bar Probe O-Ring Nut Weld Socket Description MF010 Series Low temperature oxygen sensor (See Table 1 for specifics.) MF020 Series High temperature oxygen sensor (See Table 2 for specifics.) Honeywell Sensing and Control 3 WARNING WARNING PERSONAL INJURY MISUSE OF DOCUMENTATION DO NOT USE these products as safety or emergency stop The information presented in this product sheet is for devices or in any other application where failure of the reference only. Do not use this document as a product product could result in personal injury. installation guide. Failure to comply with these instructions could result in Complete installation, operation, and maintenance death or serious injury. information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in WARRANTY/REMEDY Honeywell warrants goods of its manufacture as being free of death or serious injury. defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise SALES AND SERVICE by Honeywell in writing; please refer to your order Honeywell serves its customers through a worldwide network acknowledgement or consult your local sales office for specific of sales offices, representatives and distributors. For warranty details. If warranted goods are returned to Honeywell application assistance, current specifications, pricing or name during the period of coverage, Honeywell will repair or replace, of the nearest Authorized Distributor, contact your local sales at its option, without charge those items it finds defective. The office or: foregoing is buyer’s sole remedy and is in lieu of all other warranties, expressed or implied, including those of E-mail: info.sc@honeywell.com merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. Internet: www.honeywell.com/sensing Phone and Fax: While we provide application assistance personally, through Asia Pacific +65 6445-3033 Fax our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the +65 6355-2828 Europe +44 (0) 1698 481481 +44 (0) 1698 481676 Fax application. Latin America +1-305-805-8188 Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. +1-305-883-8257 Fax USA/Canada +1-800-537-6945 +1-815-235-6847 +1-815-235-6545 Fax Sensing and Control Honeywell 1985 Douglas Drive North Minneapolis, MN 55422 www.honeywell.com/sensing 000670-3-EN IL50 GLO Printed in USA July 2011 Copyright © 2011 Honeywell International Inc. All rights reserved.
MF010-O-LC-HT 价格&库存

很抱歉,暂时无法提供与“MF010-O-LC-HT”相匹配的价格&库存,您可以联系我们找货

免费人工找货