MIP SERIES
32354483
Issue C
Heavy Duty, Media-Isolated Pressure Transducers
1 bar to 60 bar | 15 psi to 870 psi
DESCRIPTION
DIFFERENTIATION
The MIP Series offers a heavy duty,
media-isolated pressure transducer in a
compact, stainless steel construction for
use with a wide range of media including
aggressive fluids and water. The MIP
Series provides a cost-competitive
solution for wide-ranging potential
applications in tough environments.
• Diagnostics: Beneficial in applications
where the sensor functionality and
the need to know internal or external
failure modes is critical.
• Great customer value: Multiple
configuration possibilities provide
flexibility of use in the application with
no up front NRE or tooling charges.
• Durable: Provides the tough
environmental capabilities needed,
including long-term stability, insulation
resistance and dielectric strength,
external freeze-thaw resistance for
the Metri-Pack 150 versions and EMC
performance.
VALUE TO CUSTOMERS
• Total Error Band (TEB) ±0.75 %FSS
(Full Scale Span) from -40°C to 125°C
for ratiometric output: Provides true
measurement performance over the
compensated temperature range;
small error promotes system uptime
and efficiency (see Figure 5).
• 4 mA to 20 mA output: Supports
transmission of output signals over
longer distances
• EMC performance: Operates reliably
in the presence of electromagnetic
fields, such as wireless signals, RF
communication, and electrical devices.
• Hermetically welded design: Supports
almost any media without the use of an
internal seal. The sensors are designed to
be used in harsh environments which see
aggressive media.
Industrial:
pumps
compressors
process
•
•
•
•
•
•
Certified to
NSF/ANSI/CAN 61
•
•
•
•
•
TABLE 1. POTENTIAL APPLICATIONS
INDUSTRY
FEATURES
MEDIA
water, hydraulic fluids
compressed air
food, beverage, oil, gas, steam
HVAC/R
refrigerants (butane, propane, ammonia, CO2, R134A, R407C,
R410A, R448A/Solstice® N40, R32 and R1234ze, R1234yf,
glycol + water
Transportation
gasoline, diesel fuel, engine oil, brake fluid, coolants, CNG
Medical
O2, N2, CO2, N2O, air
Rugged, stainless steel construction
Ratiometric output: 0.5 Vdc to 4.5 Vdc
Current output: 4 mA to 20 mA
Operating temperature: -40°C to
125°C
Total Error Band: ±0.75 %FSS to
±1.0 %FSS (-40°C to 125°C) for
voltage output
Industry-leading accuracy:
±0.15 %FSS BFSL for voltage output
Long term stability: ±0.25 %FSS
Radiated immunity: 100 V/m
Drinking water approval:
NSF/ANSI/CAN 61
CE, UKCA, RoHS, REACH compliant
Mis-wiring protection
PORTFOLIO
Honeywell offers a variety
of heavy duty pressure
transducers for potential use in
industrial and transportation
applications. To view the entire
product portfolio, click here.
MIP SERIES HEAVY DUTY, MEDIA-ISOLATED PRESSURE TRANSDUCERS
TABLE 2. ELECTRICAL SPECIFICATIONS (AT 25°C [77°F] AND UNDER UNLESS OTHERWISE NOTED.)
CHARACTERISTIC
RATIOMETRIC OUTPUT (AA)
CURRENT OUTPUT (CH)
Supply voltage (Vs)
5.0 Vdc ±0.25 Vdc
8 Vdc to 30 Vdc1
Output transfer function
10 % to 90 % of Vs
4 mA to 20 mA
> 2 kΩ
(Vs - 8) x 50Ω2
Output load (pull up or pull down)
Short circuit protection
yes
Current consumption
6.5 mA ±1 mA
_
Over/reverse voltage
±40 Vdc
±35 Vdc
Supply voltage: Must be de-rated to 8 Vdc to 25 Vdc for above 100°C to 125°C [212°F to 257°F].
2
Applies at 25°C [77°F]. See Figure 4 for Current Output Supply Voltage.
1
TABLE 3. PERFORMANCE SPECIFICATIONS (AT 25°C [77°F] AND UNDER UNLESS OTHERWISE NOTED.)
CHARACTERISTIC
Total Error Band1
Operating temperature range
Accuracy BFSL3
Long term stability (1000 hr, 25°C)
Typical output resolution
Typical response time4
Startup time5
EMC rating (CE Conformity):
surge immunity (all leads)
electrostatic discharge
radiated immunity
fast transient burst
immunity to conducted disturbances
radiated emissions
RATIOMETRIC OUTPUT
CURRENT OUTPUT
>10 bar or >150 psi: ±0.75 %FSS (-40°C to 125°C)
±1.0 %FSS (-20°C to 85°C)
3 to 12
24
>12 to 60
120
BURST
PRESSURE2
207
OPERATING
PRESSURE
OVERPRESSURE1
15 to 43.5
87
>43.5 to 174
348
>174 to 870
1740
BURST
PRESSURE2
3000
Overpressure: The maximum pressure which may safely be applied to the product for it to remain in specification once pressure
is returned to the operating pressure range. Exposure to higher pressures may cause permanent damage to the product.
2
Burst Pressure: The maximum pressure which may be applied without causing escape of pressure media. The product should not
be expected to function after exposure to the burst pressure.
1
FIGURE 2. RATIOMETRIC OUTPUT TRANSFER FUNCTION
FIGURE 3. ABSOLUTE VS SEALED GAGE
The transfer function shown here is applicable to a ratiometric
output ranging between 10 % Vsupply at null pressure to
90 % Vsupply at full scale pressure.
Example shown is for 100 psi.
5
4.5
Compensated Pressure Range
97.5
4.875
4.5
10
2.5
Ideal
Total
Error
Band
Pmin.
3.5
3
2.5
100 psi absolute
2
100 psi sealed gage
1.5
1
0.5
0.125
Pmax.
Pressure
4
Output (V)
Output (Vdc)
Output (% Vsupply)
90
0.5
0
0
20
40
14.7
0.8 x Vsupply
x (Pressureapplied - Pmin.) + 0.10 x Vsupply
Output (V) =
Pmax.- Pmin.
60
80
100
Pressure (psi Absolute)
120
140
114.7
FIGURE 4. CURRENT OUTPUT SUPPLY VOLTAGE VS TEMPERATURE
32
Supply Voltage (V)
30
28
Load Resistance
26
10 Ohm
24
100 Ohm
22
250 Ohm
20
18
16
100
105
110
115
120
125
Operating Temperature (ºC)
MIP Series Heavy Duty, Media-Isolated Pressure Transducers Datasheet | sps.honeywell.com/ast | 4
MIP SERIES HEAVY DUTY, MEDIA-ISOLATED PRESSURE TRANSDUCERS
TOTAL ERROR BAND
Total Error Band (TEB) is a single specification that includes
the major sources of sensor error. TEB should not be confused
with accuracy, which is actually a component of TEB. TEB is the
maximum error that the sensor could experience.
Many competitors do not use TEB—they simply specify the
accuracy of their device. Their accuracy specification, however,
may exclude certain parameters. On their datasheet, the errors
are listed individually. When combined, the total error (or what
Honeywell uses the TEB specification in its datasheet because it is would be TEB) could be significant.
the most comprehensive measurement of a sensor’s true accuracy.
Honeywell also provides the accuracy specification in order to
provide a common comparison with competitors’ literature that
does not use the TEB specification.
FIGURE 5. TEB COMPONENTS FOR THE MIP SERIES
Sources of Error
Offset
Full Scale Span
Pressure Non-Linearity
Total Error Band (%FSS)
Pressure Hysteresis
Pressure Non-Repeatability
Thermal Effect on Offset
Thermal Effect on Span
Thermal Hysteresis
Accuracy
BFSL
Total
Error
Band
3
TABLE 6. OUTPUT DIAGNOSTIC
CODE FOR RATIOMETRIC OUTPUT
FAULT CONDITION
ANALOG DIAGNOSTIC RAIL
2
Sensor internal failures
Over pressure
97.5 % of Vsupply (See Figure 2.)
1
97.5 % of Vsupply (See Figure 2.)
Total Error
Band
2.5 %
of V
0
Under pressure (for sealed
gage only)
supply
(See Figure 2.)
Power or ground loss -1
high (external pull-up resistor)
Power or ground loss
low (external pull-down resistor)
-2
-3
-40°C
[-40°F]
-20°C
[-4°F]
0°C
[32°F]
85°C
[185°F]
125°C
[257°F]
Temperature (°C [°F])
MIP Series Heavy Duty, Media-Isolated Pressure Transducers Datasheet | sps.honeywell.com/ast | 5
Pin B
Pin C
Current Output
Pin A = Return
Pin B = Supply
Pin C = Not connected
MIP SERIES HEAVY DUTY, MEDIA-ISOLATED PRESSURE
TRANSDUCERS
Pin B
(Product
marking)
FIGURE 6. METRI-PACK 150 MOUNTING DIMENSIONS (FOR REFERENCE ONLY. MM/[IN])
Product Marking
Pinout
Pin A
22,0 A/F
[0.87]
Pin C
Ratiometric Voltage Output
Pin A = Ground
Pin B = V+
Pin C = Vout
MIPXXXXXXXXXXXXX
(Product
marking)
Current Output
Pin A = Return
Pin B = Supply
Pin C = Not connected
16-Digit product listing
H YYMMDD XXXXX
Honeywell
logo
CE Mark
UKCA Mark
CE
5-Digit serial number
6-Digit date
NSF-61
NSF Mark
Pin B
F1: 7/16-20 UNF 1/4 inch 45° Flare Female Schrader (SAE J512)
Seal: 45° cone
Mating geometry: SAE J512
Installation torque:
17 N m [12 ft-lb]
(Product
Weight: 36 g [1.3marking)
oz]
MIPXXXXXXXXXXXXX
35,0
[1.38]
46,2 CE Mark
UKCA Mark
[1.82]
CE
16-Digit product listing
Seal: O-ring (included) and retaining ring ISO 1179-3-G1/4
(not included)
H YYMMDD XXXXX
Mating geometry: ISO 1179-1
5-Digit serial number
Honeywell
Installation
torque: 20 N m [14.7 ft-lb]
logo
6-Digit date Ø17,0
Weight: 33 g [1.1 oz]
Ø17,0
35,0
[1.38]
NSF-61
CE
CE Mark
UKCA Mark
16-Digit product listing
H YYMMDD XXXXX
Honeywell
logo
G1: G1/4 A-G (ISOMIPXXXXXXXXXXXXX
1179-3)
Ø17,0 Ø17,0
[0.67] [0.67]
Ø17,0
[0.67]
NSF-61
Ø17,0[0.67]
[0.67]
Ø17,0
[0.67]
35,0
35,0[1.38]
[1.38]
35,0
[1.38]number
5-Digit serial
6-Digit date
49,0
[1.93]
10,2
10,2 [0.40]
[0.40]
10,2 10,2
[0.40] [0.40]
[0.67]
NSF Mark
46,2
O-ring
[1.82]
35,0
10,2
[1.38]
[0.40]
46,2
O-ring
Profile ring
[1.82]
Profile
10,2
[0.40]
10,2
[0.40]
G2: G1/4 A-L (ISO 1179-2)
M1: M12 x 1.5 (ISO 6149-3)
Ø17,0
Ø17,0
Seal: O-ring (included)
Ø17,0 [0.67]
[0.67]
[0.67] Mating geometry: ISO 6149-1
Seal: ISO 9974-2/DIN 3869 profile
ring (included)
Ø17,0
[0.67]
Mating geometry: ISO 1179-1
Installation torque: 20 N m [15 ft-lb]
Weight: 36 g [1.3 oz]
Ø17,0
[0.67]
Ø17,0
[0.67]
35,0
[1.38]
48,535,0
[1.91]
[1.38]
Ø17,0
[0.67]
Ø17,0
10,2 [0.67]
[0.40]
35,0
[1.38]
49,0
[1.93]
35,0
35,010,2
[1.38]
[1.38]
[0.40]
O-ring
46,2
[1.82]
O-ring
10,2
[0.40]
35,0
[1.38]
[1.38]
10,2
[0.40]
35,0
35,0 [1.38]
[1.38]
10,2
[0.40]
N1: 1/4-18 NPT
35,0
[1.38]
35,0
[1.38]
46,2
35,0[1.82]
[1.38]
2
0]
50,0
48,5 [1.97]
[1.91]
10,2
[0.40]
O-ring
Ø17,0
[0.67]
48,5
[1.91]
35,0
[1.38]
Ø17,0
[0.67]
35,0
[1.38]
35,0
[1.38]
46,2
[1.82]
Ø17,0
[0.67]
10,2
[0.40]
10,2
[0.40]
50,0
[1.97]
10,2
[0.40]
49,0
[1.93]
10,2
[0.40]
10,2
[0.40]
O-ring
10,2
[0.40]
N2:
1/8-27
O-ring
Profile ring NPT
Profile ring
Seal: Pipe thread
Mating geometry: ANSI B1.20.1
Installation torque: Two to three turns from finger tight
Weight: 30 g [1.0 oz]
Pipe thread
Ø17,0
Mating geometry: ANSI B1.20.1
[0.67]
Installation torque: Two to three turns from finger tight
Weight: 38 g [1.3 oz]
Ø17,0
[0.67]
50,0
46,2
[1.97] 35,0
10,2
[1.82]
[1.38]
[0.40]
O-ring
O-ring
Ø17,0
Seal:
[0.67]
Ø17,0
[0.67]
Ø17,0
[0.67]
Ø17,0
[0.67]
35,0
[1.38]
49,0
Profile ring
46,2 [1.93]
[1.82]
46,2
[1.82]
O-ri
Installation torque: 20 N m [15 ft-lb]
Weight: 34 g [1.235,0
oz]
50,0
Ø17,0
48,5 [1.97]
[0.67]
[1.91]
10,2 Ø17,0
10,2 [0.40] [0.67]
[0.40]
Ø17,0
[0.67]
Ø17,0
[0.67]
35,0
[1.38]
49,0
46,235,0
[1.93]
[1.82]
[1.38]
Mark
46,2NSF46,2
[1.82] [1.82]
10,2
[0.40]
2
0]
]
Pin C = Not connected
[0.87]
Ø17,0
[0.67]
Ø17,0
[0.67]
Ø17,0
[0.67]
Ø17,0
[0.67]
35,0
[1.38]
35,0
[1.38]
10,2
[0.40]
50,0
[1.97]
10,2
[0.40]
46,2
[1.82]
10,2
[0.40]
35,0
[1.38]
46,2
[1.82]
10,2
[0.40]
10,2
[0.40]
O-ring
MIP Series Heavy Duty, Media-Isolated Pressure Transducers Datasheet | sps.honeywell.com/ast | 6
2-wire
3-wire
MIP SERIES HEAVY DUTY, MEDIA-ISOLATED PRESSURE TRANSDUCERS
FIGURE 7. CABLE HARNESS MOUNTING DIMENSIONS (FOR REFERENCE ONLY. MM/[IN])
Product Marking
Wireout with Free Ends
MIPXXXXXXXXXXXXX
Ratiometric Voltage Output
Black = Ground
Red = V+
White = Vout
22,0 AF
[0.87]
H YYMMDD XXXXX
Honeywell
logo
Current Output
Black = Return
Red = Supply
2-wire
CE Mark
UKCA Mark
CE
NSF-61
16-Digit product listing
5-Digit serial number
6-Digit date
NSF Mark
3-wire
F1: 7/16-20 UNF 1/4 inch 45° Flare Female Schrader (SAE J512)
Seal: 45° cone
Mating geometry: SAE J512
Installation torque: 17 N m [12 ft-lb]
Weight: 68 g [2.4 oz]
G1: G1/4 A-G (ISO 1179-3)
Seal: O-ring (included) and retaining ring ISO 1179-3-G1/4
(not included)
Mating geometry: ISO 1179-1
Installation torque: 20 N m [14.7 ft-lb]
Weight: 65 g [2.3 oz]
1000
[39.4]
MIPXXXXXXXXXXXXX
Ø4,75
H YYMMDD [0.187]
XXXXX
Honeywell
logo
31,9
[1.26]
CE Mark
UKCA 43,1
Mark
CE
[1.70]
NSF-61
1000
[39.4]
16-Digit product listing
Ø4,75
[0.187]
5-Digit serial number
6-Digit date
31,9
[1.26]
NSF Mark
43,1
[1.70]
10,2
[0.40]
10,2
[0.40]
11,2
[0.44]
11,2
[0.44]
G2: G1/4 A-L (ISO 1179-2)
Seal: ISO 9974-2/DIN 3869 profile ring (included)
Mating geometry: ISO 1179-1
Installation torque: 20 N m [15 ft-lb]
Weight: 68 g [2.4 oz]
0-Ring
M1: M12 x 1.5 (ISO 6149-3)
Seal: O-ring (included)
Mating geometry: ISO 6149-1
Installation torque: 20 N m [15 ft-lb]
Weight: 66 g [2.3 oz]
1000
[39.4]
1000
[39.4]
Ø4,75
[0.187]
Ø4,75
[0.187]
31,9
[1.26]
31,9
[1.26]
45,9
[1.81]
45,4
[1.79]
10,2
[0.40]
14,0
[0.55]
13,5
[0.53]
Profile ring
N1: 1/4-18 NPT
Seal: Pipe thread
Mating geometry: ANSI B1.20.1
Installation torque: Two to three turns from finger tight
Weight: 79 g [2.5 oz]
10,2
[0.40]
O-Ring
N2: 1/8-27 NPT
Seal: Pipe thread
Mating geometry: ANSI B1.20.1
Installation torque: Two to three turns from finger tight
Weight: 62 g [2.2 oz]
1000
[39.4]
1000
[39.4]
Ø4,75
[0.187]
Ø4,75
[0.187]
31,9
[1.26]
46,9
[1.85]
31,9
[1.26]
10,2
[0.40]
15,0
[0.59]
43,1
[1.70]
10,2
[0.40]
11,2
[0.44]
MIP Series Heavy Duty, Media-Isolated Pressure Transducers Datasheet | sps.honeywell.com/ast | 7
ADDITIONAL MATERIALS
WARRANTY/REMEDY
The following associated literature is
available on our website:
Honeywell warrants goods of its
manufacture as being free of defective
materials and faulty workmanship
during the applicable warranty period.
Honeywell’s standard product warranty
applies unless agreed to otherwise by
Honeywell in writing; please refer to
your order acknowledgment or consult
your local sales office for specific
warranty details. If warranted goods
are returned to Honeywell during the
period of coverage, Honeywell will
repair or replace, at its option, without
charge those items that Honeywell,
in its sole discretion, finds defective.
The foregoing is buyer’s sole remedy
and is in lieu of all other warranties,
expressed or implied, including those
of merchantability and fitness for a
particular purpose. In no event shall
Honeywell be liable for consequential,
special, or indirect damages.
• Product range guide
• Application-specific and technical
information
• CAD Models
While Honeywell may provide
application assistance personally,
through our literature and the
Honeywell web site, it is buyer’s
sole responsibility to determine
the suitability of the product in the
application.
FOR MORE INFORMATION
Honeywell Advanced Sensing
Technologies services its customers
through a worldwide network of sales
offices and distributors. For application
assistance, current specifications,
pricing or the nearest Authorized
Distributor, visit our website or call:
USA/Canada
Latin America
Europe
Japan
Singapore
Greater China
Specifications may change without
notice. The information we supply is
believed to be accurate and reliable
as of this writing. However, Honeywell
assumes no responsibility for its use.
+1 302 613 4491
+1 305 805 8188
+44 1344 238258
+81 (0) 3-6730-7152
+65 6355 2828
+86 4006396841
Honeywell
Advanced Sensing Technologies
830 East Arapaho Road
Richardson, TX 75081
sps.honeywell.com/ast
32354483-C-EN | C | 10/21
© 2021 Honeywell International Inc. All rights reserved.
m WARNING
PERSONAL INJURY
DO NOT USE these products as safety
or emergency stop devices or in any
other application where failure of the
product could result in personal injury.
Failure to comply with these
instructions could result in death or
serious injury.