PPT2-0300AKN2VS

PPT2-0300AKN2VS

  • 厂商:

    HONEYWELL(霍尼韦尔)

  • 封装:

    -

  • 描述:

    PPT2-0300AKN2VS

  • 数据手册
  • 价格&库存
PPT2-0300AKN2VS 数据手册
NEXT GENERATION PRECISION PRESSURE TRANSDUCER Highly Accurate Over a Wide Temperature Range Honeywell’s Next Generation Precision Pressure Transducer (PPT2) combines proven silicon sensor technology with microprocessor-based signal conditioning to provide an extremely smart pressure transducer. Available in a compact, rugged design, the PPT2 has many software features that support a wide range of digital and analog applications. FEATURES & BENEFITS HIGHLY ACCURATE • Accuracy is guaranteed over the whole operating temperature range APPLICATIONS • Simplifies System Design No additional signal compensation needed to gain the benefits of a very accurate sensor SMART, DIGITAL SENSING AND CONTROL • Efficient Data Acquisition Network up to 89 units VERSATILE AND CONFIGURABLE • Works with existing and new systems 0-5V analog and either RS-232 or RS-485 digital output • Optimizes Output User-configurable pressure units, sampling, update rate • Flags Problems Internal diagnostics set flags, indicates errors USER SELECTABLE SOFTWARE FEATURES • Baud Rate, Parity Setting, Continuous Broadcast, ASCII or Binary Output, Sensor Temperature Output (°C), Deadband, Sensitivity, Tare Value, Configurable Analog Output CE QUALIFIED. ISO-9001, ISO-14001 • Secondary Air Data • Flow and Pressure Calibrators • Altimeters • Engine Testing • Instrumentation and Analytical Equipment • Flight Testing • Process Control • Meteorology • Research and Development SPECIFICATIONS PERFORMANCE Total Error Band(1) See Ordering Information Temperature Range Operating: -40 to 85ºC Standard (S), -55 to 110°C Extended (E) Storage: -50 to 100°C Standard (S), -60 to 125°C Extended (E) Sample Rate(3) 1.0 ms to 42.67min; minimum response delay 2 ms Resolution Digital: Up to 0.001% FS, Analog: 0.1 mV typical (15+ bits) Long Term Stability 0.025% FS per year typical MECHANICAL Pressure Units(3) atm, bar, cmwc, ftwc, hPa, inHg, inwc, kg/cm2, Kpa, mBar, mmHg, MPa, mwc, psi, user, pfs Media Compatibility Suitable for non-condensing, non-corrosive, and non-combustible gases Weight 4.4 oz. (125 gm) without fittings ELECTRICAL Output(3) (4) RS-232 Digital with 0-5V Analog, RS-485 Digital with 0-5V Analog Power Requirements Supply Voltage: 6.0 to 34 VDC, Operating Current: 50 mA maximum Baud Rate User configurable between 1200 and 115200 bits/sec (3) Bus Addressing Address up to 89 units Connector MIL-C-26482, Shell Size #10, 6-pin, #20 size (3) ENVIRONMENTAL Mechanical Shock RTCA/DO-160E Sec. 7, Cat. B: up to 20 G 3 sec/direction Thermal Shock RTCA/DO-160E Sec. 5, Cat. A, -55 to 110°C Vibration RTCA/DO-160E Sec. 8, Cat. S, Curve W: 20G, 10-2000 Hz Overpressure (2) 3X FS Burst Pressure 3X FS EMC Directive Compliant, Directive 2004/108/EC, Standards BS EN 61326-1:2006 RoHS Compliant (2) Total Error Band is the sum of worst case linearity, repeatability, hysteresis, thermal effects and calibration errors over the operating temperature range. Full scale for differential ranges is the sum of + and – ranges. Calibration is traceable to NIST. (2) Exposure to overpressure will not permanently affect calibration or accuracy of unit. Burst pressure is the sum of the measured pressure plus the static pressure and exceeding it may result in media escape. (3) User configurable. (4) Recommended load impedance of 100 k-ohm or greater. (1) PPT DIMENSIONS 0.69 (17.45) SIGNAL NAME 0.12 (3.17) 2.12 (53.72) 0.17 (4.19) 0.49 (12.45) 2.2 (55.77) 0.47 (11.92) 1.56 (39.50) 0.53 (13.34) 1.06 (26.93) 0.5 (12.70) 1.97 (50.16) 2.2 (55.88) 2.47 (62.86) 0.09 (2.29) A B C D E F RS-232(TD)/RS-485 (B) RS-232(RD)/RS-485 (A) Case Ground Common Ground (GD) DC Power In Analog Output ORDERING INFORMATION PPT2 PRECISION PRESSURE TRANSDUCER FULL SCALE PRESSURE RANGE Absolute Gauge Differential Digital Total Error Band(1) Analog Total Error Band(1) 0002 N/A 2 PSI (1) ±2 PSI ±(0.075%FS + 0.20% Abs. Reading) ±(0.090%FS + 0.20% Abs. Reading) 0005 N/A 5 PSI ±5 PSI ±(0.075%FS + 0.20% Abs. Reading) ±(0.090%FS + 0.20% Abs. Reading) 0010 N/A 10 PSI ±10 PSI ±0.075%FS ±0.090%FS 0015 15 PSI N/A N/A ±0.075%FS ±0.090%FS 0020 20 PSI N/A N/A ±0.075%FS ±0.090%FS P1 PRESSURE P2 PRESSURE TYPE A Absolute 0 (vacuum) to FS N/A G Gauge Reference to FS Reference D Differential +FS to -FS rel. to P2 +FS to -FS rel. to P1 P1 PRESSURE CONNECTION (ABSOLUTE, GAUGE, DIFFERENTIAL) F Filter (blocks debris) G Stainless Swagelok (1/8 inch female) K Stainless Swagelok-compatible (1/8 inch male) R Brass barbed, right angle (1/8 inch ID tubing) W Brass barbed (1/8 inch ID tubing) X Brass Swagelok (1/8 inch female) P2 PRESSURE CONNECTION (GAUGE, DIFFERENTIAL) F Filter (blocks debris) G Stainless Swagelok (1/8 inch female) K Stainless Swagelok-compatible (1/8 inch male) R Brass barbed, right angle (1/8 inch ID tubing) W Brass barbed (1/8 inch ID tubing) X Brass Swagelok (1/8 inch female) N Not Applicable (Absolute) OUTPUTS 2V RS-232 digital, 0-5V analog 5V RS-485 digital, 0-5V analog OPERATING TEMPERATURE RANGE S Standard: -40 to 85°C E Extended: -55 to 110°C - OPTIONS PPT2 0020 A (1) W N 2V S C Power Supply/Data Cable (RS-232 only, See Below) E Certificate of Conformance F Calibration Certificate -EF See application note AN106 “Mechanically Mounting the PPT2 in Legacy PPT Applications,” at aerospace.honeywell.com/en/learn/products/sensors/precision-pressure. PRESSURE CONNECTION OPTIONS F G K Option C R W X ESD (electrostatic discharge) sensitive device Damage may occur when subjected to high energy ESD. Proper ESD precautions should be taken to avoid performance degradation or loss of functionality. EOS (electrical overstress) sensitive device Damage may occur when subjected to EOS. Do not exceed specified ratings to avoid performance degradation or loss of functionality. Honeywell reserves the right to make changes to improve reliability, function or design. Honeywell does not assume any liability arising out of the application or use of any product or circuit described herein; neither does it convey any license under its patent rights nor the rights of others. For more information aerospace.honeywell.com/en/learn/products/sensors/precision-pressure Honeywell Aerospace 1944 East Sky Harbor Circle Phoenix, AZ 85034 aerospace.honeywell.com ADS-14211 N61-1598-000-002 | 02/20 © 2020 Honeywell International Inc.
PPT2-0300AKN2VS 价格&库存

很抱歉,暂时无法提供与“PPT2-0300AKN2VS”相匹配的价格&库存,您可以联系我们找货

免费人工找货