0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
PPTR1050AP2VD-R033

PPTR1050AP2VD-R033

  • 厂商:

    HONEYWELL(霍尼韦尔)

  • 封装:

    圆柱型

  • 描述:

    TRANSDUCER PREC PRESSURE

  • 数据手册
  • 价格&库存
PPTR1050AP2VD-R033 数据手册
Precision Pressure Transducer-Ruggedized PPTR Honeywell’s PPTR offers a rugged, smart pressure transducer for use in harsh environments. It combines proven silicon sensor technology with microprocessor-based signal conditioning to provide an extremely smart pressure transducer. Designed with a hermetically sealed, stainless steel construction, the PPTR operates in severe vibration, thermal and mechanical shock environments. The PPTR has many software features that support a wide range of applications. APPLICATIONS: ±0.10% Accuracy from -40 to 85ºC  Engine Test Stands  Flight Testing  Water Depth  Unmanned Underwater Vehicles  Instrumentation and Analytical Equipment  Process Control  Research and Development Hermetically Sealed Digital and Analog Qualified FEATURES AND BENEFITS  ISO-9001 ISO-14001 High Accuracy 0.10% FS typical accuracy from -40 to 85 C System Design - No additional signal compensation   Simplifies needed to gain the benefits of a very accurate sensor. Smart, Digital Sensing and Control Data Acquisition - Connect up to 89 units on a multidrop  Efficient bus using built-in RS-485 capability. Easy Interface - Directly connects to PC via communication ports. Closes the Loop - Smart PPTR makes control decisions.  Versatile and Configurable with existing and new systems. - All units have 0-5V analog  Works and either RS-232 or RS-485 digital outputs. Isolation diaphragms handle most media - harsh gases or liquids. Rugged Design - Operates in severe vibration, thermal, and mechanical shock environments. Optimizes Output - User-configurable pressure units, sampling, update rate. Flags Problems - Internal diagnostics set flags, provide alarms.  User Selectable Software Features  Baud Rate, Parity Setting, Continuous Broadcast, ASCII or Binary Output, Sensor Temperature Output ( C or F), Deadband, Sensitivity, Tare Value, Configurable Analog Output PPTR SPECIFICATIONS Performance Specifications (1) Accuracy: (from -40 to 85ºC) Digital: ±0.10% FS Typ., ±0.20% FS Max.(2) Analog: ±0.12% FS Typ., ±0.24% FS Max.(2) Temperature: ±1ºC (at sensing element) Temperature Range: Operating -40 to 85ºC (-40 to 185ºF) Storage: -55 to 90ºC (-67 to 194ºF) Sample Rate(5): 8.33ms to 51.2 min Resolution: Digital: Up to 0.0011% FS Analog: 1.22mV steps (12 bits) Response Delay: (1000/update rate) +1ms, minimum 17ms Mechanical Specifications Pressure Ranges and Type: See Ordering Information Pressure Units(5): atm, bar, cmwc, ftwc, hPa, inHg, inwc, kg/cm², KPa, mBar, mmHg, MPa, mwc, psi, user, Icom, pfs Media Compatibility: Suitable for media compatible with 316 stainless steel (Consult factory for Hastelloy diaphragm.) Weight: 14 oz. (397 gm) 6-pin connector 22 oz. (624 gm) NPT w/pigtail style Electrical Specifications Output: RS-232 Digital w/0-5VAnalog(5) RS-485 Digital w/0-5V Analog(5) Power Requirements: Supply Voltage: 6 to 30 VDC Operating Current: 19-27mA Baud Rate(5): 1200, 2400, 4800, 9600, 14400, 19200, 28800 Bus Addressing(5): Address up to 89 units Environmental Features(3)(4) Overpressure: 3x FS, maximum 6000psi Burst Pressure: 3x FS, maximum 8500psi Mechanical Shock: 1500g, 0.5ms half sine Temp Shock: 24 1-hour cycles, -40 to 85ºC Vibration: 0.5in or 20G’s, 20Hz – 2K Hz (1) Accuracy is the sum of worst case linearity, repeatability, hysteresis, thermal effects and calibration errors from -40 to 85ºC. Typical is the average of absolute value of errors at all pressures and temperatures. Calibration is traceable to NIST. (2)Tighter accuracy available on some models. Consult factory. (3) Exposure to overpressure will not permanently affect calibration or accuracy of unit. Exceeding burst pressure may result in media escape. Mechanical Shock tested per MIL-STD-883D, M2002.3, Cond. B.Vibration tested per MIL-STD-883D, M2007.2, Cond. A. (4) CE Mark per IEC 61326. See www.ssec.honeywell.com/pressure/datasheets.html for information on test levels and results. Connector MIL-C26482, Shell Size #10, 6-pin #20 size. (5) User configurable. (6) Demonstration kit includes unit, power supply/data cable (120V), demonstration software, and user manual. CASE OUTLINE ORDERING INFORMATION PPTR Precision Pressure Transducer - Ruggedized FULL SCALE PRESSURE RANGE Absolute Gauge 0015 15 PSI n/a 0020 20 PSI 20 PSI 0040 40 PSI 40 PSI 0100 100 PSI 100 PSI 0300 300 PSI 300 PSI 0500 500 PSI 500 PSI 1000 1000 PSI 1000 PSI 1500 1500 PSI 1500 PSI 3000 3000 PSI 3000 PSI TYPE P1 Pressure P2 Pressure A Absolute 0(vacuum) to FS N/A G Gauge Reference to FS Reference P1 PRESSURE CONNECTION P ¼ - 18 NPT (internal) OUTPUTS 2V RS-232 digital, 0-5V analog 5V RS-485 digital, 0-5V analog ELECTRICAL CONFIGURATION AND CONNECTION B 6-pin connector(4) D ½ - 14 NPT external w/4ft pigtail cable OPTIONS A Demonstration Kit(6) (RS-232 only) B Mating Connector – for 6-pin connector version C Power Supply/Data Cable – for 6-pin connector version (RS-232 only) PPTR 0500 A P 2V B -A Find out more For more information on Honeywell’s Precision Pressure Transducers visit us online at www.honeywell.com/pressuresensing or contact us at 800-323-8295 or 763-954-2474. Customer Service Email: ps.customer.support@honeywell.com. Honeywell reserves the right to make changes to improve reliability, function or design. Honeywell does not assume any liability arising out of the application or use of any product or circuit described herein; neither does it convey any license under its patent rights nor the rights of others. Covered by one or more of the following US Patents: 4,918,992, 4,788,521 and 5,948,988. Honeywell Aerospace Honeywell International Inc. 12001 Highway 55 Plymouth, MN 55441 www.honeywell.com ADS-14180 June 2009 ©2009 Honeywell International Inc.
PPTR1050AP2VD-R033 价格&库存

很抱歉,暂时无法提供与“PPTR1050AP2VD-R033”相匹配的价格&库存,您可以联系我们找货

免费人工找货