PX2 Series
Heavy Duty Pressure
Transducer
DESCRIPTION
Honeywell’s PX2 Series Heavy Duty Pressure Transducer is a
line of highly configurable pressure transducers that use
piezoresistive sensing technology with ASIC (Application
Specific Integrated Circuit) signal conditioning in a stainless
steel housing that is compatible with a variety of harsh media.
The PX2 Series is compatible with a variety of harsh media
including brake fluid, refrigerants, engine oil, tap water,
hydraulic fluids, and compressed air. The wide operating
temperature range, up to IP69K protection, and CE compliance
allow compatibility for reliable performance in tough
environments.
The PX2 Series is fully calibrated and compensated for
transducer offset, sensitivity, temperature effects and nonlinearity using an on-board ASIC. This provides a Total Error
Band of ±2% over the operation temperature range of -40 ºC to
125 ºC [-40 °F to 257 °F].
These transducers measure absolute or sealed gage pressure.
The absolute versions have an internal vacuum reference and
an output value proportional to absolute pressure. The sealed
gage versions have an internal pressure reference of one
atmosphere at sea level.
With thousands of possible configurations, the PX2 Series
allows Honeywell to meet customer requirements and quickly
provide samples. New standard configurations are regularly
being added to the series.
Honeywell’s PX2 transducer is available in 7 bar to 34 bar
[100 psi to 500 psi] pressure ranges with additional pressure
ranges coming soon. All products are designed and
manufactured according to ISO 9001 standards.
VALUE PROPOSITIONS(=competitive differentiator)
Designed for configurability: Numerous standard or
custom connectors, ports, pressure types and ranges, and
output options:
Allows customers the ability to configure devices to
meet their specific application needs
Allows for quick availability of product samples
Cost-effective: The PX2 Series’ configurability makes it a
cost-effective solution; by configuring the transducer to
meet the system’s needs, the PX2 Series reduces the
design and implementation costs of the end product
Application expertise: Honeywell’s knowledgeable
application engineers are available to answer customers’
specific design questions during the development, launch,
and production of their product
Global support: Honeywell’s global presence offers
customers immediate product and application support; this
allows Honeywell to support the customer throughout the
development cycle from design to global manufacturing
Industry-leading Total Error Band (TEB): Honeywell
specifies TEB—the most comprehensive, clear, and
meaningful measurement—that provides the transducer’s
true accuracy over a compensated temperature range of 40°C to 125 °C [-40 °F to 257 °F]. The PX2 Series TEB of
±2%:
Provides excellent transducers interchangeability due to
minimal part-to-part variation in accuracy
Eliminates the customers’ need for individual transducer
testing and calibration
Supports system accuracy and warranty requirements
Durable: Compatibility with a wide variety of harsh media
(brake fluid, refrigerants, engine oil, tap water, hydraulic
fluids, and compressed air), wide operating temperature
range, up to IP69K sealing, and CE compliance allow for
use in tough environments
Designed to Six Sigma standards: Provides the highest
level of product quality, performance, and consistency; Six
Sigma provides confidence that the transducer will perform
to specification
PX2 Series
FEATURES AND BENEFITS
Broad compensated temperature range allows
customers to design the same transducer into a broad set
of applications
Good EMC protection means that the transducer will not
be damaged by environmental electromagnetic interference
POTENTIAL APPLICATIONS
Industrial:
HVAC/R
- Compressor inlet and outlet pressure
- Rooftop chillers
- Compressor rack rooms
- Refrigerant recovery systems
- Compressor oil pressure
General
- System pressure
- Fluid power, flow and level
- Factory automation
- Pneumatics
- Injection molding knockout valves
- Pumps
- Valves
-
Packaging/laminating
equipment
Sprayers, industrial
lasers
Foam dispensing
Solar energy
Emissions monitoring
Transportation (Heavy Equipment and Alternative Fuel
Vehicles):
System pressure
Fluid power, flow and level
Pneumatics
Light hydraulics
Brake and engine oil pressure
Transmission
Truck/trailer air braking
Air Compressors
- Compressor inlet and outlet pressure
- Filter pressure drop
- Cooling water inlet and outlet pressure
- Compressor oil pressure
Table 1. Electrical Specifications
Characteristic
Ratiometric
Current Output
Regulated Output
Output Transfer Function Order Code (See Figure 5.)
AA
AB
CH
BC
BD
BE
BG
4 mA
16 mA
8V
1V
5V
9V
0.25 V 0.5 V
10 V
4V
13 V
8V
30 V
30 V 30 V
5 mA
1
Output transfer function :
null output value
full scale span (FSS)
2
operating supply voltage, min.(Vs)
2
operating supply voltage, typ. (Vs)
2
operating supply voltage, max. (Vs)
Supply current (typ.)
Output load (pull up or down)
minimum
maximum
5
Absolute voltage ratings :
6
minimum
6
maximum
maximum applied to output pin
7
EMC rating CE compliance :
electrostatic discharge
radiated immunity
fast transient burst
immunity to conducted disturbances
radiated emissions
7
EMC Rating – ISO 11452-2
radiated immunity
10% of Vs
5% of Vs
80% of Vs
90% of Vs
4.75 V
4.75 V
5V
5V
5.25 V
5.25 V
4 mA
30 V
4
2 kOhm
3
30 V
2 kOhm
(Vs - 8) x 50 Ohm
-16 V
16 V
Vs
3
1V
4V
8V
-16 V
30 V
4
-16 V
30 V
Vs
±4 kV contact, ±8 kV air per IEC 61000-4-2
10 V/m (80 MHz to 1000 MHz) per IEC 61000-4-3
±1 kV per IEC61000-4-4
3 V per IEC61000-4-6
40 dB 30 MHz to 230 MHz; 47 dB 230 MHz to 1000 MHz per CISPR 11
100 V/m 200 MHz to 2 GHz
20 V/m 200 MHz to 2 GHz
Notes:
1.
2.
3.
4.
5.
Transfer function options are shown in the Nomenclature and Order Guide. (See Figure 5.)
Transducer will not produce valid output when supply voltage is outside of operating range.
Applies at 25 °C. See Figure 1 for Regulated Output Supply Voltage.
Applies at 25 °C. See Figure 2 for Current Output Supply Voltage.
Absolute maximum ratings are the extreme limits the device can withstand without damage to the product. Voltages above these ratings may
cause permanent damage. Exposure to absolute maximum conditions for extended periods may degrade device reliability.
6. Absolute voltage applies to potential across power and ground terminals.
7. All EMC ratings verified with the Packard Metripak 150 connector type.
2
www.honeywell.com/sensing
3
Heavy Duty Pressure Transducer
Figure 2. Current Output Supply Voltage
32
32
30
30
28
28
Supply Voltage (V)
Supply Voltage (V)
Figure 1. Regulated Output Supply Voltage
26
24
22
20
26
250 Ohm
24
100 Ohm
22
10 Ohm
20
18
18
16
16
85
90
100
105
115
110
120
Operating Temperature (°C)
Table 2. Performance Specifications
Parameter
9
Operating temperature range
10
Storage temperature range
11
Compensated temperature range
12
Overpressure minimum rating
13
Burst pressure minimum rating
14
Accuracy
16
Offset error
17
Total Error Band
18
Response time
19
Turn on time
20
Life
Notes:
125
100
105
110
115
120
125
Operating Temperature (°C)
8
Description
-40 °C to 125 °C [-40 °F to 257 °F]
-40 °C to 125 °C [-40 °F to 257 °F]
-40 °C to 125 °C [-40 °F to 257 °F]
3x operating pressure: Max. 1000 psi (See Figure 3.)
5x operating pressure: Max. 1500 psi (See Figure 3.)
15
±0.25 %FSS (See Figure 4.)
15
±1 %FSS
15
±2 %FSS (-40 °C to 125 °C [-40 °F to 257 °F]) (See Figure 4.)