PX2EN1XX100PAAAX 数据手册
PX2 Series Heavy Duty Pressure Transducer DESCRIPTION Honeywell’s PX2 Series Heavy Duty Pressure Transducer is a line of highly configurable pressure transducers that use piezoresistive sensing technology with ASIC (Application Specific Integrated Circuit) signal conditioning in a stainless steel housing that is compatible with a variety of harsh media. The PX2 Series is compatible with a variety of harsh media including brake fluid, refrigerants, engine oil, tap water, hydraulic fluids, and compressed air. The wide operating temperature range, up to IP69K protection, and CE compliance allow compatibility for reliable performance in tough environments. The PX2 Series is fully calibrated and compensated for transducer offset, sensitivity, temperature effects and nonlinearity using an on-board ASIC. This provides a Total Error Band of ±2% over the operation temperature range of -40 ºC to 125 ºC [-40 °F to 257 °F]. These transducers measure absolute or sealed gage pressure. The absolute versions have an internal vacuum reference and an output value proportional to absolute pressure. The sealed gage versions have an internal pressure reference of one atmosphere at sea level. With thousands of possible configurations, the PX2 Series allows Honeywell to meet customer requirements and quickly provide samples. New standard configurations are regularly being added to the series. Honeywell’s PX2 transducer is available in 7 bar to 34 bar [100 psi to 500 psi] pressure ranges with additional pressure ranges coming soon. All products are designed and manufactured according to ISO 9001 standards. VALUE PROPOSITIONS(=competitive differentiator)  Designed for configurability: Numerous standard or custom connectors, ports, pressure types and ranges, and output options: Allows customers the ability to configure devices to meet their specific application needs Allows for quick availability of product samples  Cost-effective: The PX2 Series’ configurability makes it a cost-effective solution; by configuring the transducer to meet the system’s needs, the PX2 Series reduces the design and implementation costs of the end product  Application expertise: Honeywell’s knowledgeable application engineers are available to answer customers’ specific design questions during the development, launch, and production of their product  Global support: Honeywell’s global presence offers customers immediate product and application support; this allows Honeywell to support the customer throughout the development cycle from design to global manufacturing Industry-leading Total Error Band (TEB): Honeywell specifies TEB—the most comprehensive, clear, and meaningful measurement—that provides the transducer’s true accuracy over a compensated temperature range of 40°C to 125 °C [-40 °F to 257 °F]. The PX2 Series TEB of ±2%: Provides excellent transducers interchangeability due to minimal part-to-part variation in accuracy Eliminates the customers’ need for individual transducer testing and calibration Supports system accuracy and warranty requirements Durable: Compatibility with a wide variety of harsh media (brake fluid, refrigerants, engine oil, tap water, hydraulic fluids, and compressed air), wide operating temperature range, up to IP69K sealing, and CE compliance allow for use in tough environments  Designed to Six Sigma standards: Provides the highest level of product quality, performance, and consistency; Six Sigma provides confidence that the transducer will perform to specification PX2 Series FEATURES AND BENEFITS Broad compensated temperature range allows customers to design the same transducer into a broad set of applications Good EMC protection means that the transducer will not be damaged by environmental electromagnetic interference POTENTIAL APPLICATIONS Industrial: HVAC/R - Compressor inlet and outlet pressure - Rooftop chillers - Compressor rack rooms - Refrigerant recovery systems - Compressor oil pressure General - System pressure - Fluid power, flow and level - Factory automation - Pneumatics - Injection molding knockout valves - Pumps - Valves - Packaging/laminating equipment Sprayers, industrial lasers Foam dispensing Solar energy Emissions monitoring Transportation (Heavy Equipment and Alternative Fuel Vehicles): System pressure Fluid power, flow and level Pneumatics Light hydraulics Brake and engine oil pressure Transmission Truck/trailer air braking Air Compressors - Compressor inlet and outlet pressure - Filter pressure drop - Cooling water inlet and outlet pressure - Compressor oil pressure Table 1. Electrical Specifications Characteristic Ratiometric Current Output Regulated Output Output Transfer Function Order Code (See Figure 5.) AA AB CH BC BD BE BG 4 mA 16 mA 8V 1V 5V 9V 0.25 V 0.5 V 10 V 4V 13 V 8V 30 V 30 V 30 V 5 mA 1 Output transfer function : null output value full scale span (FSS) 2 operating supply voltage, min.(Vs) 2 operating supply voltage, typ. (Vs) 2 operating supply voltage, max. (Vs) Supply current (typ.) Output load (pull up or down) minimum maximum 5 Absolute voltage ratings : 6 minimum 6 maximum maximum applied to output pin 7 EMC rating CE compliance : electrostatic discharge radiated immunity fast transient burst immunity to conducted disturbances radiated emissions 7 EMC Rating – ISO 11452-2 radiated immunity 10% of Vs 5% of Vs 80% of Vs 90% of Vs 4.75 V 4.75 V 5V 5V 5.25 V 5.25 V 4 mA 30 V 4 2 kOhm 3 30 V 2 kOhm (Vs - 8) x 50 Ohm -16 V 16 V Vs 3 1V 4V 8V -16 V 30 V 4 -16 V 30 V Vs ±4 kV contact, ±8 kV air per IEC 61000-4-2 10 V/m (80 MHz to 1000 MHz) per IEC 61000-4-3 ±1 kV per IEC61000-4-4 3 V per IEC61000-4-6 40 dB 30 MHz to 230 MHz; 47 dB 230 MHz to 1000 MHz per CISPR 11 100 V/m 200 MHz to 2 GHz 20 V/m 200 MHz to 2 GHz Notes: 1. 2. 3. 4. 5. Transfer function options are shown in the Nomenclature and Order Guide. (See Figure 5.) Transducer will not produce valid output when supply voltage is outside of operating range. Applies at 25 °C. See Figure 1 for Regulated Output Supply Voltage. Applies at 25 °C. See Figure 2 for Current Output Supply Voltage. Absolute maximum ratings are the extreme limits the device can withstand without damage to the product. Voltages above these ratings may cause permanent damage. Exposure to absolute maximum conditions for extended periods may degrade device reliability. 6. Absolute voltage applies to potential across power and ground terminals. 7. All EMC ratings verified with the Packard Metripak 150 connector type. 2 www.honeywell.com/sensing 3 Heavy Duty Pressure Transducer Figure 2. Current Output Supply Voltage 32 32 30 30 28 28 Supply Voltage (V) Supply Voltage (V) Figure 1. Regulated Output Supply Voltage 26 24 22 20 26 250 Ohm 24 100 Ohm 22 10 Ohm 20 18 18 16 16 85 90 100 105 115 110 120 Operating Temperature (°C) Table 2. Performance Specifications Parameter 9 Operating temperature range 10 Storage temperature range 11 Compensated temperature range 12 Overpressure minimum rating 13 Burst pressure minimum rating 14 Accuracy 16 Offset error 17 Total Error Band 18 Response time 19 Turn on time 20 Life Notes: 125 100 105 110 115 120 125 Operating Temperature (°C) 8 Description -40 °C to 125 °C [-40 °F to 257 °F] -40 °C to 125 °C [-40 °F to 257 °F] -40 °C to 125 °C [-40 °F to 257 °F] 3x operating pressure: Max. 1000 psi (See Figure 3.) 5x operating pressure: Max. 1500 psi (See Figure 3.) 15 ±0.25 %FSS (See Figure 4.) 15 ±1 %FSS 15 ±2 %FSS (-40 °C to 125 °C [-40 °F to 257 °F]) (See Figure 4.)
PX2EN1XX100PAAAX 价格&库存

很抱歉,暂时无法提供与“PX2EN1XX100PAAAX”相匹配的价格&库存,您可以联系我们找货

免费人工找货