SCC30AD2

SCC30AD2

  • 厂商:

    HONEYWELL(霍尼韦尔)

  • 封装:

    DIP-6

  • 描述:

    SCC30AD2

  • 数据手册
  • 价格&库存
SCC30AD2 数据手册
SCC Series Silicon pressure sensors 0 psi to 5 psi and 0 psi to 300 psi DESCRIPTION The SCC Series sensors offer an extremely low cost sensor of the diaphragm and devices are thereby available to element with a temperature stable output when driven with a measure both differential and gage pressures. constant current source. These integrated circuit sensors This product is packaged either in standard low cost chip were designed for extremely cost sensitive applications where carrier “button” package or a DIP package. Both packages precise accuracy over a wide temperature range is not are designed for applications where the sensing element is to required. This series is intended for use with non-corrosive, be integral to the OEM equipment. These packages can be o- non-ionic working fluids such as air, and dry gases. ring sealed, epoxied, and/or clamped onto a pressure fitting. Absolute devices have an internal vacuum reference and an A closed bridge four pin SIP configuration is provided for output voltage proportional to applied pressure. The electrical connection to the button package. The DIP package differential devices allow application of pressure to either side offers a 5-pin open bridge configuration. FEATURES TYPICAL APPLICATIONS • Low cost sensor element • Pneumatic controls • Internal temperature compensation • Automotive diagnostics • Differential or gage pressures • Medical equipment • Dental equipment • Environmental controls ORDERING INFORMATION Par dering Partt Number for Or Ordering Pr essur e Range Pressur essure Sensor in Sensor in Sensor in Sensor in Button Package “N” Package Nipple Package DIP Package 0 psid to 5 psid or psig SCC05D SCC05DN SCC05DP1 SCC05GD2, SCC05DD4 0 psid to 15 psid or psig SCC015D SCC015DN SCC015DP1 SCC15GD2, SCC15DD4 0 psid to 30 psid or psig SCC30D SCC30DN SCC30DP1 SCC30GD2, SCC30DD4 0 psig to 100 psig SCC100D SCC100DN – SCC100GD2, SCC100DD4 0 psia to 15 psia SCC15A SCC15AN SCC15AP1 SCC15AD2 0 psia to 30 psia SCC30A SCC30AN SCC30AP1 SCC30AD2 0 psia to 100 psia SCC100A SCC100AN – SCC100AD2 0 psia to 300 psi – – – – WARNING MISUSE OF DOCUMENTATION • The information presented in this product sheet is for reference only. Do not use this document as a product installation guide. • Complete installation, operation, and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. WARNING PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failur e to comply with these instr uctions could rresult esult in Failure instructions death or serious injur y. injury SCC Series SPECIFICATION CHARACTERISTICS (Maximum Ratings for All Devices) Supply current, IS 1.5 mA Compensated temperature range 0 °C to 50 °C [32 °F to 122 °F] Operating temperature range -40 °C to 85 °C [-40 °F to 185 °F] Storage temperature range -55 °C to 125 °C [-67 °F to 257 °F] Humidity 0 % to 100 % RH Lead temperature 250 °C [482 °F] Soldering 2 sec to 4 sec Common-mode pressure 150 psi PERFORMANCE CHARACTERISTICS (Individual Models) Is=1.0 mA, TA=25 °C [77 °F](1) Part Operating Maximum Effect(5, 4) Full-Scale on Span on Offset Span(6) Number Pressure Range Over Pressure 0 °C to 50 °C 0 °C to 50 °C mV SCC05(D,G) 0 psid to 5 psid (g) 20 psi 0.50 % 1.50 % 30 µV/°C 25-65 SCC15A Accuracy (2) Effect (3, 4) 0 psia to 15 psia 30 psia 0.50 % 1.50 % 40 µV/°C 40-95 SCC15(D,G) 0 psid to 15 psid (g) 30 psi 0.50 % 1.50 % 40 µV/°C 40-95 SCC30(D,G) 0 psid to 30 psid (g) 60 psi 0.50 % 1.50 % 60 µV/°C 60-150 0 psia to 100 psia 150 psia 0.50 % 1.50 % 30 µV/°C 85-225 0 psig to 100 psig 150 psig 0.50 % 1.50 % 90 µV/°C 85-225 0 psia to 300 psia 450 psia 0.50 % 1.50 % 50 µV/°C 50-120 SCC100A SCC100(D,G) (7) SCC300A PERFORMANCE SPECIFICATIONS (All Models) Is=10.0 Ma, Ta=25 °C [77 °F] Zero Pressure Offset (8) Min. Typ. Max. Unit -30.0 -10.0 20.0 mV Combined Linearity, Hysteresis and Repeatability(2) – 0.25 0.50 % FSO Long Term Stability of Offset and Span(9) – 0.10 – mV Response Time (10 % to 90 %)(10) – 0.10 – ms Input Impedance 4.00 5.00 6.50 kOhm Output Impedance 4.00 5.00 6.50 kOhm Specification Notes: Note 1: Reference Conditions; Supply Current = 1.0 mA; TA = 25 °C [77 °F], Common-mode Line Pressure = 0 psig, Pressure Applied to P1, unless otherwise noted. Note 2: Accuracy is the sum of Hysteresis and Linearity. Hysteresis is the maximum output difference at any point within the operating pressure range for increasing and decreasing pressure. Linearity refers to the best straight line fit as measured for the offset, full-scale and ½ full-scale pressure at 25 °C [77 °F]. Note 3: This is the maximum temperature shift for span when measured between 0 °C and 50 °C [32 °F to 122 °F] relative to the 25 °C [77 °F] reading. Typical temperature coefficients for span and resistance are -2200 ppm/°C and 2200 ppm/°C respectively. Note 4: Temperature effect on span and offset are guaranteed by design. Therefore these parameters are not 100 % tested. Note 5: This is the maximum temperature shift for offset when measured at 0 °C and 50 °C [32 °F to 122 °F] divided by the temperature difference. Note 6: Span is the algebraic difference between the output voltage at full-scale pressure and the ouput at zero pressure. Note 7: The SCC100D devices can only be used in a forward gauge mode. Application of more than 30 psig to the back side of any of the SCC Series devices can result in device failure. On the SCC100GD2 pressure can only be applied to the back side of the die. No pressure I accessible from the front/top side of die. Note 8: The zero pressure offset is 30 to -20 mV max. form parts SCCxxxGD2 and SCCxxDD4 devices. Note 9: Maximum difference in output at any pressure with the operating pressure range and temperature within 0 °C and 50 °C [32 °F to 122 °F]. a) 100 temperature cycles, 0 °C and 50 °C [32 °F to 122 °F] b) 1.0 million pressure cycles, 0 psi to full-scale span. Note 10: Response time for a 0 psi to full-scale span pressure step change. 10 % to 90 % rise time. 2 www.honeywell.com/sensing Silicon pressure sensors ELECTRICAL CONNECTIONS (+Vo) (Vs) MOUNTING DIMENSIONS IN MM (INCHES), FOR REFERENCE ONLY Button package EQUIVALENT CIRCUITS Vs 3 2 + OUTPUT 4 - 1 GND Button, Nipple and “N” Packages 4 Vs 5 Nipple package 1 - OUTPUT 3 + 2 GND DIP Packages N Housing package Honeywell Sensing and Control 3 D2 DIP package DD4 DIP package AD4 DIP package WARRANTY/REMEDY Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The for egoing is buyer emedy and foregoing buyer’’s sole rremedy is in lieu of all war ranties, expr essed warranties, expressed or implied, including those of SALES AND SERVICE mer chantability and fitness for a merchantability par ticular purpose. In no event shall particular Honeywell be liable for consequential, special, or indir ect indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. Automation and Control Solutions Sensing and Control Honeywell 11 West Spring Street Freeport, Illinois 61032, USA www.honeywell.com 008135-2-EN IL50 GLO May 2005 Copyright 2004-2005 Honeywell International Inc. Honeywell serves its customers through a worldwide network of sales offices, representatives and distributors. For application assistance, current specifications, pricing or name of the nearest Authorized Distributor, contact your local sales office or: E-mail: info.sc@honeywell.com Inter net: www.honeywell.com/sensing Internet: Phone and Fax: Asia Pacific +65 6355-2828 +65 6445-3033 Fax Europe +44 (0) 1698 481481 +44 (0) 1698 481676 Fax Latin America +1-305-805-8188 +1-305-883-8257 Fax USA/Canada +1-800-537-6945 +1-815-235-6847 +1-815-235-6545 Fax
SCC30AD2 价格&库存

很抱歉,暂时无法提供与“SCC30AD2”相匹配的价格&库存,您可以联系我们找货

免费人工找货