SX05GD2 数据手册
Datasheet -- SX05GD2 SX05GD2 Pressure Sensors: Measurement Type: Gage; 0 psid to 5 psid, Unamplified, "D2" DIP Package - Straight Port Features ● ● Representative photograph, actual product appearance may vary. Due to regional agency approval requirements, some products may not be available in your area. Please contact your regional Honeywell office regarding your product of choice. ● ● ● Low Cost High-Impedance Bridge Absolute and Differential (Gauge) Low Noise Low Power Consumption for Battery Power Typical Applications ● ● ● ● ● ● Medical Instrumentation Barometric Measurement Pneumatic Controls Battery Powered Equipment Description The SX Series pressure sensors provide the lowest cost components for measuring pressures up to 150 psi. These sensors are designed for use with non-corrosive, non-ionic media, such as air and dry gases. Convenient pressure ranges are available to measure differential, gauge, and absolute pressures from 0 psi to 1 psi (SX01) up to 0 psi to 150 psi (SX150). The Absolute (A) devices have an internal vacuum reference and an output voltage proportional to absolute pressure. The differential (D) devices allow application of pressure to either side of the diaphragm and can be used for gauge or differential pressure measurements. This product is packaged in either the standard low cost chip carrier “button” package, a plastic ported “N” package, or a DIP package. file:///C|/Documents%20and%20Settings/rabab/Desktop/Datasheet%20--%20SX05GD2.htm (1 of 5)15/03/2005 01:23:29 ã Datasheet -- SX05GD2 All packages are designed for applications where the sensing element is integral to the OEM equipment. These packages can be oring sealed, epoxied, and/or clamped onto a pressure fitting. A closed-bridge four pin SIP configuration is provided for electrical connection to the “Button” or “N” Package. The DIP Package mounts on a PC board like a standard IC with through-hole pins. This extremely small size package enables the use of multiple sensors in applications with limited space. SX05GD2 Pressure Sensors: Measurement Type: Gage; 0 psid to 5 psid, Unamplified, "D2" DIP Package - Straight Port Product Specifications Measurement Type Gage Signal Conditioning Unamplified Pressure Range 0 psid to 5 psid Maximum Overpressure 20 psi Supply Voltage 12 Vdc max. Compensated No Output Calibration No Response Time 100 µS Termination PCB Port Style Straight Package Style D2 DIP Typical Sensitivity 3 mV/V/psi Full Scale Span 50 mV min., 75 mV typ., 100 mV max. Zero Pressure Offset -35.0 mV min., -20.0 mV typ., 0.0 mV max. Linearity, Repeatability & Hysteresis Error - 0.5 min., 0.2 typ., 0.5 max. % Full Scale Span Repeatability 0.5 % span Input Resistance 4.1 kOhms typ. Output Resistance 4.1 kOhms typ. file:///C|/Documents%20and%20Settings/rabab/Desktop/Datasheet%20--%20SX05GD2.htm (2 of 5)15/03/2005 01:23:29 ã Datasheet -- SX05GD2 Operating Temperature Range -40 °C to 85 °C [-40 °F to 185 °F] Storage Temperature Range -55 °C to 125 °C [-67 °F to 257 °F] Media Compatibility Clean, dry gases only UNSPSC Code 411121 UNSPSC Commodity 411121 Transducers Comment Lead Temperature Soldering 2 s to 4 s at 250 °C [482 °F] Availability Global Series Name SX Series SX05GD2 Pressure Sensors: Measurement Type: Gage; 0 psid to 5 psid, Unamplified, "D2" DIP Package - Straight Port file:///C|/Documents%20and%20Settings/rabab/Desktop/Datasheet%20--%20SX05GD2.htm (3 of 5)15/03/2005 01:23:29 ã Datasheet -- SX05GD2 SX05GD2 Pressure Sensors: Measurement Type: Gage; 0 psid to 5 psid, Unamplified, "D2" DIP Package - Straight Port [Electrical Connections] SX05GD2 Pressure Sensors: Measurement Type: Gage; 0 psid to 5 psid, Unamplified, "D2" DIP Package - Straight Port [Equivalent circuit] SX05GD2 Pressure Sensors: Measurement Type: Gage; 0 psid to 5 psid, Unamplified, "D2" DIP Package - Straight Port PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices, or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. file:///C|/Documents%20and%20Settings/rabab/Desktop/Datasheet%20--%20SX05GD2.htm (4 of 5)15/03/2005 01:23:29 ã Datasheet -- SX05GD2 MISUSE OF DOCUMENTATION ● ● The information presented in this product sheet (or catalog) is for reference only. DO NOT USE this document as product installation information. Complete installation, operation and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. © Copyright Honeywell Inc.1998-2004 All rights reserved. file:///C|/Documents%20and%20Settings/rabab/Desktop/Datasheet%20--%20SX05GD2.htm (5 of 5)15/03/2005 01:23:29 ã
SX05GD2
物料型号:SX05GD2

器件简介:SX系列压力传感器是用于测量高达150 psi压力的低成本组件。设计用于与非腐蚀性、非离子介质(如空气和干燥气体)一起使用。

引脚分配:文档中未明确提供引脚分配信息,但提到了“D2”DIP封装,通常这种封装有8个引脚。

参数特性: - 测量类型:表压(Gage) - 信号调理:未放大(Unamplified) - 压力范围:0 psid至5 psid - 最大过压:20 psi - 供电电压:最大12Vdc - 输出校准:无 - 响应时间:100秒 - 端口样式:直通(Straight) - 封装样式:D2DIP - 典型灵敏度:3 mV/V/psi - 满量程跨度:最小50 mV,典型75 mV,最大100 mV - 零压力偏移:最小-35.0 mV,典型-20.0 mV,最大0.0 mV - 线性度、重复性和滞后误差:最小-0.5%,典型0.2%,最大0.5%满量程跨度 - 重复性:0.5%跨度 - 输入电阻:典型值4.1 kOhms - 输出电阻:典型值4.1 kOhms

功能详解:SX系列压力传感器提供绝对(A)和差分(D)设备,绝对设备具有内部真空参考和与绝对压力成比例的输出电压。差分设备允许在膜片的任一侧施加压力,可用于表压或差分压力测量。

应用信息:适用于医疗、仪器、气压测量、气动控制和电池供电设备。

封装信息:该产品采用标准低成本芯片载体“按钮”封装、塑料端口“N”封装或DIP封装。DIP封装安装在PC板上,像标准IC一样使用通孔引脚。这种极小尺寸的封装使得在空间有限的应用中可以使用多个传感器。
SX05GD2 价格&库存

很抱歉,暂时无法提供与“SX05GD2”相匹配的价格&库存,您可以联系我们找货

免费人工找货