SZR-MY2-1-DC24V

SZR-MY2-1-DC24V

  • 厂商:

    HONEYWELL(霍尼韦尔)

  • 封装:

    插件,21.5x28mm

  • 描述:

    RELAY GEN PURPOSE DPDT 5A 24V

  • 数据手册
  • 价格&库存
SZR-MY2-1-DC24V 数据手册
General Purpose Power Relay FEATURES • Small package design • DPDT has a fine silver contact with 5 A capability • 4PDT has a gold-plated silver contact with 3 A capability • High dielectric strength (1,800 Vac) • High reliability and long life • Ultra-high sensitivity with quick response time (20 ms max.) • Options include LED indicator, diode protection, and LED indicator/diode protection • UL listed, CE certified, CSA certified TYPICAL APPLICATIONS • Control panels • Elevator panels • Machine tools • Test equipment WARNING PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. Sensing and Control SZR-MY Series ® SZR-MY Series general-purpose power relays are designed for a wide range of applications including power as well as logic control for factory machines and control panels. SZR-MY Series relays have a small package design for multiple application needs. Relays are available in two configurations: DPDT with a 5A load and 4PDT with a 3 A load. One standard and three options are available: LED indicator, internal surge protection diode, and LED indicator/diode protection. Honeywell’s global sales and distribution channels ensure a rapid response and excellent customer service. WARNING MISUSE OF DOCUMENTATION • The information presented in this product sheet is for reference only. Do not use this document as a product installation guide. • Complete installation, operation, and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. General Purpose Power Relays SZR-MY Series RELAY MODEL SELECTION GUIDE Type Terminal Standard Plug-in/Solder PCB LED Indicator Plug-in/Solder DIODE surge suppression LED indicator + surge suppression Contact Catalog Listing DPDT SZR-MY2-1 4PDT SZR-MY4-1 DPDT SZR-MY2-1P 4PDT SZR-MY4-1P DPDT SZR-MY2-N1 4PDT SZR-MY4-N1 DPDT SZR-MY2-D1 4PDT SZR-MY4-D1 DPDT SZR-MY2-X1 4PDT SZR-MY4-X1 SOCKETS – REQUIRED ACCESSORIES Din-rail Mounting Solder Terminal PCB Terminal Relay Contact DPDT For use with SZR-MY2-1, -N1, D1, -X1 SZX-SMF-08N SZX-SMB-08 SZX-SMB-08P 4PDT For use with SZR-MY4-1, -N1, D1, -X1 SZX-SMF-14N 2 Honeywell • Sensing and Control SZX-SMB-14 SZX-SMB-14P General Purpose Power Relays SZR-MY Series CONTACT RATINGS Type Load Ratings DPDT Resistive Load (p.f. = 1) Inductive load (p.f. = 0.4, L/R = 7 ms) Rated load 220 Vac, 5A 24 Vdc, 5A Carry current Max. operating voltage Max. operating current Max. switching capacity Min. permissible load 4PDT Resistive Load (p.f. = 1) Inductive load (p.f. = 0.4, L/R = 7 ms) 220 Vac, 2A 24 Vdc, 2A 220 Vac, 3A 24 Vdc, 3A 220 Vac, 0.8 A 24 Vdc, 1.5 A 5A 250 Vac, 125 Vdc 3A 250 Vac, 125 Vdc 5A 3A 1,100 VA, 120 W 440 VA, 48 W 660 VA, 72 W 1 mA, 5 Vdc 176 VA, 16 W 1 mA, 1 Vdc COIL RATINGS Rated Voltage (V) AC Coil Inductance (H) Coil resistance Armature OFF Armature ON 0.04 0.08 (Ω) 6 214.1 183 12.2 Pick-up Voltage (V) Dropout Voltage (V) Maximum Voltage (V) Power Consumption (W) Approx. 12 106.5 91 46 0.17 0.33 24 53.8 46 180 0.69 1.3 Max. Min. 50 25.7 22 788 3.22 5.66 75 % 30% 100/110 11.7/12.9 10/11 3,750 14.54 24.6 Approx 1.0 W to 1.2 W (60 Hz) 110% 110/120 9.9/10.8 8.4/9.2 4,430 19.2 32.1 0.9 W to 1.1 W 200/220 6.2/6.8 5.3/5.8 12,950 54.75 94.07 (60 Hz) 220/240 4.8/5.3 4.2/4.6 18,790 83.5 136.4 40 0.17 0.33 6 DC Rated Current (mA) 50 Hz 60 Hz 150 12 75 160 0.73 1.37 Max. Min. 24 36.9 650 3.2 5.72 75% 10% 48 18.5 2,600 10.6 21.0 100/110 9.1/10 11,000 45.6 86.2 Approx. 110% 0.9 W Note 1: The rated current and coil resistance are measured at a coil temperature of 23 °C [73.4 °F] with tolerances of +15%, -20% for AC rated current and ± 15% for DC coil resistance. Note 2: The rated current of N1 and X1 types is 4 mA higher than the value in the table above. Honeywell • Sensing and Control 3 General Purpose Power Relays SZR-MY Series SPECIFICATIONS Contact material Contact resistance Operate time Release time Operating Mechanical frequency Electrical Silver Max. 50 MOhm Max. 20 ms Max. 20 ms 18,000 operations per hour 1,800 operations per hour Insulation resistance Dielectric withstand voltage Min. 100 Mw at 500 Vdc 1,800 Vac 50 Hz/60 Hz for one minute between non-continuous current carrying terminals and between coil thermals and contact terminals Vibration Mechanical durability 10 Hz to 55 Hz at double amplitude of 1.0 mm resistance Malfunction durability 10 Hz to 55 Hz at double amplitude of 1.0 mm Shock resistance Mechanical durability 1,000 m/s2 (approx. 100 g) Malfunction durability 200 m/s2 (approx. 20 g) Service life Mechanical AC: Min. 50 million operations (at operating frequency of 18,000 operations/hour) DC: Min. 100 million operations (at operating frequency of 18,000 operations/hour) Electrical DPDT: Min. 500,000 operations (at operating frequency of 1,800 operations/hour) 4PDT: Min. 200,000 operations (at operating frequency of 1,800 operations/hour) Weight Approximately 35 g Note 1: The data shown above are of initial value CHARACTERISTIC DATA AC inductive p.f.=0.4 DC resistive 1 0.5 DC inductive L/R=7ms 0.1 5 10 ) 4 1,000 500 AC110V AC220V 100 50 DC24V 10 0 50 100 500 Rated operating voltage(V) 3 4 5 6 AC resistive 5 3 AC inductive p.f.=0.4 DC resistive 1 0.5 DC inductive L/R=7ms 0.1 5 10 50 100 500 Rated operating voltage(V) 4 Honeywell • Sensing and Control 500 AC110V p.f.=0.4 AC220V p.f.=0.4 100 50 DC24V L/R=7ms 10 7 8 Current(A) 0 1 2 Current(A) ) Induc tive Load 4 ) 4 10 1,000 Resistive Load Number of operations(× 10 4PDT Rated operating current(A) Max. Switching capacity 1 2 Number of operations(× 10 5 Induc tive Load 1,000 500 AC110V AC220V 100 50 DC30V 10 0 1 2 Number of operations(× 10 AC resistive 10 4 ) Resistive Load Number of operations(× 10 DPDT Rated operating current(A) Max. Switching capacity 1,000 500 AC110V p.f.=0.4 DC30V L/R=7ms 100 50 AC220V p.f.=0.4 10 0 3 Current(A) 0.5 1 1.5 Current(A) General Purpose Power Relays SZR-MY Series HOLDING CLIPS • Holding clips are included with the sockets • Holding clips for the SMF-08N and SMF-14N cannot be removed once inserted • Holding clips for all SMB sockets are wire for easy removal • Holding clips are to be inserted into the slots provided on the socket DIMENSIONS (For reference only – mm/in) Figure 1. Dimensions For SZX-SMF-08N and SZX-SMF-14N sockets Figure 2. Dimensions For all SZX-SMB sockets 5,0 [0.20] 14,5 [0.57] 29,0 [1.14] 22,0 [0.87] 6,5 [0.26] 4,6 [0.18] 6,2 [0.24] 39,6 [1.56] 49,9 [1.96] 2,2 [0.09 ] Honeywell • Sensing and Control 15° 5 General Purpose Power Relays SZR-MY Series CATALOG LISTING MATRIX SZR – MY 2 - ___ 1 P - AC110-120V Terminal Type __ = Solder/Plug-in P = PCB Mounting Type 1 = Terminal Poles 2 = DPDT 4 = 4PDT Amp Rating: MY = 5 A or 3 A LY = 10 A Product Type General Purpose Relay 6 Honeywell • Sensing and Control Option Type __ = No Indicator or Diode D = Internal Surge Protection Diode N = Red LED Operation Indicator X = LED and Diode Voltage Rating: AC6V = AC12V = AC24V = AC50V = AC100V = AC110-120V = AC200V = AC220V = AC220-240V = DC6V = DC12V = DC24V = DC48V = DC100V = 6 Vac 12 Vac 24 Vac 50 Vac 100 Vac 110/120 Vac 200 Vac 220 Vac 220/240 Vac 6 Vdc 12 Vdc 24 Vdc 48 Vdc 100 Vdc General Purpose Power Relays SZR-MY Series Max. 28,0 [1.10] 6,3 [0.25] 0,5 [0.02] 2,6 [0.10] FIGURE 3. DIMENSION, CIRCUIT DIAGRAM, TERMINAL ARRANGEMENT, AND MOUNTING HOLE FOR SZR-MY2-1, SZR-MY2-N1, SZR-MY2-D1, and SZR-MY2-X1 8 - O 1,2 [0.05] x 3 Holes 0,5 [0.02] Max. 21,5 [0.85] Max. 36,0 [1.42] MY2-1 6,0 [0.24] MY2-N1 AC MY2-N1 DC MY2-D1 MY2-X1 1 4 1 4 1 4 1 4 1 4 5 8 5 8 5 8 5 8 5 8 9 12 9 12 9 13 14 13 14 13 - + 12 9 14 13 - + 12 9 14 13 12 - + 14 Bottom view 3,5 [0.14] 0,5 [0.02] Max. 36,0 [1.42] Max. 21,5 [0.85] 6,0 [0.24] The circuit diagram is the same wit standard type of SZR-MY2-1 or the SZR-MY4-1 Honeywell • Sensing and Control 7 3,3 [0.13] 1,0 [0.04] Max. 28,0 [1.10] 6,3 [0.25] 0,5 [0.02] FIGURE 4. DIMENSION, CIRCUIT DIAGRAM, TERMINAL ARRANGEMENT, AND MOUNTING HOLE FOR SZR-MY2-1P and SZR-MY4-1P General Purpose Power Relays SZR-MY Series Max. 28,0 [1.10] 6,3 [0.25] 2,6 [0.10] 0,5 [0.02] FIGURE 5. DIMENSION, CIRCUIT DIAGRAM, TERMINAL ARRANGEMENT, AND MOUNTING HOLE FOR SZR-MY4-1, SZR-MY4-N1, SZR-MY4-D1, and SZR-MY4-X1 14 - O 1.2 [0.05] x 3 Holes Max. 21,5 [0.85] 0,5 [0.02] Max. 36,0 [1.42] MY4-1 6,0 [0.24] MY4-N1 AC MY4-N1 DC MY4-D1 MY4-X1 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 5 6 7 8 5 6 7 8 5 6 7 8 5 6 7 8 5 6 7 8 9 10 11 12 9 10 11 12 9 10 11 12 9 10 11 12 9 10 11 13 14 13 14 13 - + 14 13 - + 14 13 - + Bottom view FIGURE 6. CIRCUIT DRAWING FOR SZR-MY2- and SZR-MY4- 4PDT DPDT 13.2 14- 1.3 0.1 13.2 3.75 8 Honeywell • Sensing and Control 8- 1.3 0.1 6.35 6.3 12.65 4.3 4.1 4.4 12 14 General Purpose Power Relays SZR-MY Series SOCKETS FIGURE 7. SZX-SMF-08N 18,0 [0.70] 30,0 [1.18] 25,0 [0.99] 35,2 [1.39] 62,0 ± 0,1 [2.44 ± .004] 26,0 [1.02] 15,6 [0.61] 3,0 [0.12] 2 - O 4,5 [0.18] Holes 26,0 [1.02] 45,0 [1.77] 4,2 [0.17] 62,0 ± 0,1 [2.44 ± .004] 35,2 [1.39] 2-M3 or 2-M4 15,6 [0.61] 3,0 [0.12] 3,9 [0.15] 26,0 [1.02] 45,0 [1.77] 4,2 [0.17] 62,0 [2.44] 6,0 [0.24] 3,9 [0.15] 62,0 [2.44] 6,0 [0.24] FIGURE 8. SZX-SMF-14N 2-M3 or 2-M4 2 - O 4,5 [0.18] Holes 18,0 [0.70] 26,0 [1.02] 30,0 [1.18] Max. 61,0 [2.40] Max. 61,0 [2.40] 25,0 [0.99] FIGURE 9. SZX-SMB-08 FIGURE 10. SZX-SMB-14 14 - 3 x O 1,2 [0.05] Holes 8 - 3 X O 1,2 [0.05] Holes 2,7 [0.11] 7,7 [0.30] Max. 25,5 [1.00] 2,7 [0.11] 2,6 [0.10] 7,7 [0.30] Max. 29,5 [1.16] 0,3 [0.01] Max. 29,5 [1.16] Max. 25,5 [1.00] 0,3 [0.01] Max 24,0 [0.94] Max. 24,0 [0.94] 2,6 [0.10] Max. 20,0 [0.79] 21,4 ± 0,2 0.84 ± .008 Honeywell • Sensing and Control 25,8 ± 0,2 [1.02 ± .008] 38,5 [1.52] 25,8 ± 0,2 [1.02 ± .008] Max. 38,5 [1.52] Max. 20,0 [0.79] 21,4 ± 0,2 [0.84 ± .008] 9 General Purpose Power Relays SZR-MY Series 2,7 [0.11] 4,2 [0.17] WARRANTY/REMEDY Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Contact your local sales office for warranty information. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace without charge those items it finds defective. The foregoing is Buyer’s sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. Sensing and Control www.honeywell.com/sensing Honeywell 11 West Spring Street Freeport, Illinois 61032 009550-4-EN IL50 GLO 0104 Printed in USA Copyright 2003-2004 Honeywell International Inc. All Rights Reserved. 4,1 [0.16] 4,4 [0.17] 38,5 [1.52] 12,65 [0.50] 8 - O 2,0 [0.08] Holes 13,2 [0.52] 6,4 [0.25] 6,4 [0.25] 6,35 [0.25] 5,8 [0.23] 4,1 [0.16] Max. 16,5 [0.65] 13,2 [0.52] Max. 29,5 [1.16] 2,6 [0.10] 4,2 [0.17] 12,65 [0.50] Max. 16,5 [0.65] 6,35 [0.25] 2,6 [0.10] 38,5 [1.52] Max. 22,0 [0.87] 0,3 [0.01] Max. 29,5 [1.16] Max. 25,5 [1.00] 0,3 [0.01] 2,7 [0.11] 4,3 [0.17] Max. 22,0 [0.87] 5,8 [0.23] 4,3 [0.17] FIGURE 12. SZX-SMB-14P Max. 25,5 [1.00] FIGURE 11. SZX-SMB-08P 14 - O 2,0 [0.08] Holes While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. For application assistance, current specifications, or name of the nearest Authorized Distributor, contact a nearby sales office. Or call: 1-800-537-6945 USA/Canada 1-815-235-6847 International FAX 1-815-235-6545 USA INTERNET www.honeywell.com/sensing info.sc@honeywell.com
SZR-MY2-1-DC24V 价格&库存

很抱歉,暂时无法提供与“SZR-MY2-1-DC24V”相匹配的价格&库存,您可以联系我们找货

免费人工找货