HF105F-1/024DT-1ZSTF(257) 数据手册
HF1 05 F -1
MINIATURE HIGH POWER RELAY
Features
File No.:E134517
●
●
●
●
●
V
D E
File No.:40025518 (DC Type)
40A switching capability
4kV dielectric strength (between coil and contacts)
Heavy load up to 7200VA
PCB coil terminals, ideal for heavy duty load
Unenclosed, Plastic sealed and dust protected types available
File No.:CQC12002071130(DC Type)
CQC10002049165(DC Type)
CQC16002140270(DC Type)
RoHS compliant
COIL
CONTACT DATA
Contact
arrangement
Contact
resistance1)
1A
1B
1C (NO)
50m
DC type: Approx. 900mW;
AC type: Approx. 2VA
Coil power
max. (at 1A 24VDC)
AgSnO2, AgCdO
Contact material
11080VA
1200W
Max. switching
capacity
Max. switching
voltage
Max. switching
current
HF105F-1
rating
HF105F-1L
rating
Mechanical
endurance
1C (NC)
4155VA
450W
5540VA
600W
2770VA
300W
SAFETY APPROVAL RATINGS
30A 277VAC
277VAC / 28VDC
40A2)
15A
20A
10A
30A 240VAC 15A 240VAC 20A 240VAC
20A 28VDC
10A 28VDC
25A 240VAC 15A 240VAC 20A 240VAC
10A 240VAC
Electrical
endurance
10A 28VDC
20A 28VDC
1 Form A
10A 240VAC
20A 28VDC
20A 28VDC
10A 28VDC
2HP 250VAC
AgCdO
28A 277VAC
1 x 107OPS
277VAC(FLA=20)(LRA=60)
1H type(Non-plastic sealed): 1 x 105OPS
(28A 277VAC, Resistive load,
AgCdO, Room temp., 1s on 9s off)
AgCdO
15A 277VAC
10A 28VDC
1/2HP 250VAC
1/4HP 125VAC
277VAC(FLA=10)(LRA=33)
AgSnO2
AgCdO
2HP 250VAC
UL/
CUL
1 Form B
CHARACTERISTICS
Insulation resistance
Dielectric Between coil & contacts
strength Between open contacts
1000M (at 500VDC)
2500VAC/4000VAC 1min
1500VAC 1min
Operate time (at rated. volt.)
DC type: 15ms max.
Release time (at rated. volt.)
DC type: 10ms max.
DC: -55 to 85
AC: -55 to 60
Ambient temperature
Vibration resistance
Humidity
1HP 125VAC
30A 28VDC
10A 28VDC
Notes:1) The data shown above are initial values.
2) Long time current-carrying under 40A condition is prohibited.
Shock resistance
40A 277VAC
AgSnO2
AgCdO
Functional
98m/s2
Destructive
980m/s2
10Hz to 55Hz 1.5mm DA
5% to 85% RH
NO
30A 277VAC
1HP 125VAC
20A 277VAC
AgCdO
20A 28VDC
277VAC(FLA=20)(LRA=60)
1 Form C
AgSnO2
AgCdO
20A 277VAC
1/2HP 250VAC
1/4HP 125VAC
NC
10A 277VAC
AgCdO
10A 28VDC
Termination
PCB
277VAC(FLA=10)(LRA=33)
Unit weight
Approx.36g
Unenclosed (Only for DC coil),
Plastic sealed,
Dust protected
Notes: 1) All values unspecified are at room temperature.
2) Only typical loads are listed above. Other load specifications
can be available upon request.
Construction
Notes: 1) For plastic sealed type, the venting-hole should be opened in
test.
2) The data shown above are initial values.
3) Please find coil temperature curve in the characteristic curves below.
4) UL insulation system: Class F, Class B.
HONGFA RELAY
ISO9001, ISO/TS16949 , ISO14001, OHSAS18001, IECQ QC 080000 CERTIFIED
2020 Rev. 1.00
309
COIL DATA
at 23
DC type
AC type
Nominal
Voltage
VDC
Pick-up
Voltage
VDC
max.3)
5
3.75
Drop-out
Max.
Voltage
Voltage
VDC
VDC *4)
min.3)
0.5
Nominal Pick-up
Voltage Voltage
VAC
VAC
max.3)
Coil
Resistance
27 x (1 10%)
6.5
12
9.6
Drop-out
Voltage
VAC
min.3)
Max.
Voltage
VDC *4)
2.4
15.6
25 x (1 10%)
Coil
Resistance
6
4.50
0.6
7.8
40 x (1 10%)
24
19.2
4.8
31.2
100 x (1 10%)
9
6.75
0.9
11.7
97 x (1 10%)
120
96.0
24.0
156
2500 x (1 10%)
12
9.00
1.2
15.6
155 x (1 10%)
208
166.4
41
270.4
11000 x (1 10%)
15
11.25
1.5
19.5
256 x (1 10%)
220
176
44
286
13490 x (1 10%)
18
13.50
1.8
23.4
380 x (1 10%)
240
192
48
286
13490 x (1 10%)
24
18.00
2.4
31.2
660 x (1 10%)
277
220
54
360.1
15000 x (1 10%)
48
36.00
4.8
62.4
70
52.50
7.0
91
5500 x (1 10%)
110
82.50
11
143
13450 x (1 10%)
2560 x (1 10%)
Notes: 1) When requiring pick-up voltage < 80% of nominal voltage,
special order allowed.
2) The data shown above are initial values at 50Hz. When
requiring 60Hz, special order allowed.
3) The data shown above are initial values.
4) *Maximum voltage refers to the maximum voltage which
relay coil could endure in a short period of time.
ORDERING INFORMATION
HF 1 05F -1 /
Type
018 D
T -1H S
T
F (XXX)
HF105-1: 30A (Unenclosed, only for DC coil)
HF105-1L: 25A (Unenclosed, only for DC coil)
HF105F-1: 30A
HF105F-1L: 25A
DC: 5VDC to 110VDC
Coil voltage
AC: 12VAC to 277VAC
Coil voltage form
Termination
D: DC
A: AC
6: With Pin NO.6, Dielectric Strength Between Coil and Contact: 2500VAC
T: Without Pin NO.6, Dielectric Strength Between Coil and Contact: 4000VAC
Nil: Without Pin NO.6, Dielectric Strength Between Coil and Contact: 2500VAC
Contact arrangement 1H: 1 Form A 1D: 1 Form B 1Z: 1 Form C
Construction
S: Plastic sealed
Nil: Dust protected (For HF105F-1, HF105F-1L)
Unenclosed (For HF105-1, HF105-1L)
Contact material
T: AgSnO2
Nil: AgCdO
Insulation standard
F: Class F
Nil: Class B
Special code3)
XXX: Customer special requirement
1)2)
Nil: Standard
Notes:1) We recommend dust protected types for a clean environment (free from contaminations like H2S, SO2, NO2, dust, etc.).
We suggest to choose plastic sealed types and validate it in real application for an unclean environment (with contaminations
like H2S, SO2, NO2, dust, etc.).
2) Contact is recommended for suitable condition and specifications if water cleaning or surface process is involved in assembling relays
on PCB.
3) The customer special requirement express as special code after evaluating by Hongfa.
4) For products that should meet the explosion-proof requirements of "IEC 60079 series",please note [Ex] after the specification while
placing orders.Not all products have explosion-proof certification,so please contact us if necessary, in order to select the suitable products.
310
OUTLINE DIMENSIONS, WIRING DIAGRAM AND PC BOARD LAYOUT
HF105F-1
Unit: mm
1 Form A
Outline Dimensions
Wiring Diagram
PCB Layout
(Bottom view)
(Bottom view)
With 6# terminal
+0.2
3.6
27.1- 0.8
20 +0.2
- 0.8
5.3
3x 2.1
3.8
2x 1.1
8.9
+0.2
- 0.8
20.2
3.6
14
17.8
22.1
Without 6# terminal
6# terminal
+0.2
27.1- 0.8
20+0.2
- 0.8
5.3
2x 2.1
3.8
2x 1.1
14
17.8
20.2
+0.2
- 0.8
22.1
1 Form B
With 6# terminal
3.6
20 +0.2
- 0.8
27.1
+0.2
- 0.8
3x 2.1
5.3
3.8
2x 1.1
8.9
20.2 +0.2
- 0.8
6# terminal
14
22.1
17.8
Without 6# terminal
+0.2
27.1- 0.8
3.6
20 +0.2
- 0.8
2x 2.1
5.3
3.8
2x 1.1
20.2
+0.2
- 0.8
14
17.8
22.1
311
OUTLINE DIMENSIONS, WIRING DIAGRAM AND PC BOARD LAYOUT
Unit: mm
1 Form C
Outline Dimensions
With 6# terminal
3.6
20 +0.2
- 0.8
Wiring Diagram
PCB Layout
(Bottom view)
(Bottom view)
+0.2
27.1- 0.8
4x 2.1
5.3
3.8
2x 1.1
8.9
20.2
14
+0.2
- 0.8
17.8
22.1
Without 6# terminal
+0.2
3x 2.1
27.1- 0.8
3.6
20 +0.2
- 0.8
6# terminal
5.3
3.8
2x 1.1
14
17.8
20.2
+0.2
- 0.8
22.1
HF105-1
1 Form A
With 6# terminal
3.6
16.3
23.3
4.1
3x 2.1
3.8
2x 1.1
8.9
6# terminal
14
17.8
Without 6# terminal
3.6
16.3
23.3
4.1
2x 2.1
3.8
2x 1.1
14
17.8
312
OUTLINE DIMENSIONS, WIRING DIAGRAM AND PC BOARD LAYOUT
Unit: mm
1 Form B
Outline Dimensions
With 6# terminal
3.6
16.3
Wiring Diagram
PCB Layout
(Bottom view)
(Bottom view)
3x 2.1
23.3
4.1
3.8
2x 1.1
8.9
6# terminal
14
17.8
Without 6# terminal
3.6
16.3
2x 2.1
23.3
4.1
3.8
2x 1.1
14
17.8
1 Form C
With 6# terminal
4x 2.1
3.6
16.3
23.3
4.1
3.8
2x 1.1
8.9
6# terminal
14
17.8
Without 6# terminal
3.6
16.3
3x 2.1
23.3
4.1
3.8
2x 1.1
14
17.8
Remark: 1) In case of no tolerance shown in outline dimension: outline dimension ≤1mm, tolerance should be ±0.2mm; outline dimension >1mm
and ≤5mm, tolerance should be ±0.3mm; outline dimension >5mm, tolerance should be ±0.4mm.
2) The tolerance without indicating for PCB layout is always ±0.1mm.
313
CHARACTERISTIC CURVES
MAXIMUM SWITCHING POWER
COIL TEMPERATURE RISE
ENDURANCE CURVE
110
100
100
DC Coil
1A
40
1C (NO)
30
1B
20
1C (NC)
15
100
30
1A
90
10
1C (NO)
80
1C (NC)
1B
10
70
30A
60
1
AC Resistive
Load
15A
40
DC Resistive
1 Load
10
25A
20A
50
0A
100
200
1000
Contact Voltage (V)
0
10
20
30
40
Contact Current (A)
0
80
90
100
110
120
130
140
150
160
Percentage Of Nominal Coil Voltage
Test conditions:
Resistive load, Dust protected,
AgCdO, Room temp., 1s on 9s off.
Disclaimer
The specification is for reference only. See to "Terminology and Guidelines" for more information. Specifications subject to change without notice.
We could not evaluate all the performance and all the parameters for every possible application. Thus the user should be in a right position to
choose the suitable product for their own application. If there is any query, please contact Hongfa for the technical service. However, it is the user’s
responsibility to determine which product should be used only.
© Xiamen Hongfa Electroacoustic Co., Ltd. All rights of Hongfa are reserved.
314