HF105F-2/012D-1HSF(257) 数据手册
H F1 0 5F - 2
MINIATURE HIGH POWER RELAY
Features
File No.:E134517
● 40A switching capability
● Heavy load up to 7200VA
V
D E
● PCB coil terminals, ideal for heavy duty load
File No.:40025518 (DC type)
● Plastic sealed and dust protected types available
File No.: CQC10002049165(DC type)
CQC16002140270(DC type)
RoHS compliant
CONTACT DATA
Contact
arrangement
Contact
resistance1)
COIL
1A
1B
1C (NO)
DC type: Approx. 900mW;
AC type: Approx. 2VA
Coil power
50m max.(at 1A 24VDC)
Contact material
Max. switching
capacity
Max. switching
voltage
Max. switching
current
1C (NC)
AgSnO2, AgCdO
SAFETY APPROVAL RATINGS
7200VA/560W 3600VA/280W 4800VA/560W 2400VA/280W
40A
15A
2)
20A
10A
1 Form A
When PCB terminals carry current≤30A
When PCB terminals do not carry current
(only QC terminals carry current)≤25A
Max.continuous
current
HF105F-2
rating
HF105F-2L
rating
Mechanical
endurance
30A 277VAC
277VAC/28VDC
AgSnO2
AgCdO
OPS
5
1H type(Non-plastic sealed): 1 x 10 OPS
(28A 277VAC, Resistive load,
AgCdO, Room temp., 1s on 9s off)
Electrical
endurance
UL/
CUL
1 Form B
Notes:1) The data shown above are initial values.
2) Long time current-carrying under 40A condition is prohibited.
CHARACTERISTICS
Insulation resistance
Dielectric Between coil & contacts
strength Between open contacts
2500VAC 1min
Operate time (at rated. volt.)
DC type: 15ms max.
Release time (at rated. volt.)
DC type: 10ms max.
Functional
to 85
to 60
98m/s2
Destructive
980m/s2
Ambient temperature
Shock resistance
Vibration resistance
Humidity
DC: -55
AC: -55
AgCdO
15A 277VAC
10A 28VDC
1/2HP 250VAC
1/4HP 125VAC
277VAC(FLA=10)(LRA=33)
AgSnO2
AgCdO
2HP 250VAC
AgCdO
20A 277VAC
30A 277VAC
1HP 125VAC
20A 28VDC
277VAC(FLA=20)(LRA=60)
1 Form C
AgSnO2
AgCdO
20A 277VAC
1/2HP 250VAC
1/4HP 125VAC
NC
10A 277VAC
AgCdO
10A 28VDC
10Hz to 55Hz 1.5mm DA
277VAC(FLA=10)(LRA=33)
5% to 85% RH
Notes: 1) All values unspecified are at room temperature.
2) Only typical loads are listed above. Other load specifications
can be available upon request.
Termination
PCB & QC
Unit weight
Approx. 36g
Plastic sealed,
Dust protected
Construction
NO
1000M (at 500VDC)
1500VAC 1min
28A 277VAC
277VAC(FLA=20)(LRA=60)
25A 240VAC 15A 240VAC 20A 240VAC 10A 240VAC
20A 28VDC 10A 28VDC 20A 28VDC 10A 28VDC
1 x 10
1HP 125VAC
30A 28VDC
AgCdO
30A 240VAC 15A 240VAC 20A 240VAC 10A 240VAC
20A 28VDC 10A 28VDC 20A 28VDC 10A 28VDC
7
40A 277VAC
2HP 250VAC
Notes: 1) For plastic sealed type, the venting-hole should be opened in test.
2) The data shown above are initial values.
3) Please find coil temperature curve in the characteristic curves below.
4) UL insulation system: Class F, Class B.
HONGFA RELAY
ISO9001, ISO/TS16949 , ISO14001, OHSAS18001, IECQ QC 080000 CERTIFIED
2019 Rev. 1.02
315
COIL DATA
at 23
DC type
AC type
Nominal
Voltage
VDC
Pick-up
Voltage
VDC
max.3)
Drop-out
Voltage
VDC
min.3)
Max.
Voltage
VDC *4)
Coil
Resistance
Nominal Pick-up
Voltage
Voltage
VAC
VAC
max.3)
5
3.75
0.5
6.5
27 x (1 10%)
12
6
4.50
0.6
7.8
40 x (1 10%)
24
Drop-out
Voltage
VAC
min.3)
Max.
Voltage
VDC *4)
9.6
2.4
15.6
19.2
4.8
31.2
100 x (1 10%)
Coil
Resistance
25 x (1 10%)
9
6.75
0.9
11.7
97 x (1 10%)
120
96.0
24.0
156
2500 x (1 10%)
12
9.00
1.2
15.6
155 x (1 10%)
208
166.4
41
270.4
11000 x (1 10%)
13490 x (1 10%)
15
11.25
1.5
19.5
256 x (1 10%)
220
176
44
286
18
13.50
1.8
23.4
380 x (1 10%)
240
192
48
286
13490 x (1 10%)
24
18.00
2.4
31.2
660 x (1 10%)
277
220
54
360.1
15000 x (1 10%)
48
36.00
4.8
62.4
2560 x (1 10%)
70
52.50
7.0
91
5500 x (1 10%)
110
82.50
11
143
13450 x (1 10%)
Notes: 1) When requiring pick-up voltage < 80% of nominal voltage,
special order allowed.
2) The data shown above are initial values at 50Hz. When
requiring 60Hz, special order allowed.
3) The data shown above are initial values.
4) *Maximum voltage refers to the maximum voltage which
relay coil could endure in a short period of time.
ORDERING INFORMATION
HF 1 0 5F -2 / 0 1 8 D
Type
-1H
S
T
F
(XXX)
HF105F-2: 30A
HF105F-2L: 25A
Coil voltage
DC: 5VDC to 110VDC
AC: 12VAC to 277VAC
Coil voltage form
D: DC
Contact arrangement 1H:1 Form A
Construction
1)
A: AC
1D:1 Form B
S: Plastic sealed
1Z:1 Form C
Nil: Dust protected
Contact material
T: AgSnO2
Nil: AgCdO
Insulation standard
F: Class F
Nil: Class B
Special code3)
XXX: Customer special requirement
Nil: Standard
Notes: 1) We recommend dust protected types for a clean environment (free from contaminations like H2S, SO2, NO2, dust, etc.).
We suggest to choose plastic sealed types and validate it in real application for an unclean environment (with contaminations
like H2S, SO2, NO2, dust, etc.).
2) Contact is recommended for suitable condition and specifications if water cleaning or surface process is involved in assembling relays
on PCB.
3) The customer special requirement express as special code after evaluating by Hongfa.
316
OUTLINE DIMENSIONS, WIRING DIAGRAM AND PC BOARD LAYOUT
Unit: mm
1 Form A
Outline Dimensions
Wiring Diagram
PCB Layout
(Bottom view)
27.5
3.6±0.5
27.8
2x 2.1
0.8(两处)
6.4(两处)
2x 1.1
3.8
(Bottom view)
14
17.8
(Top view)
1 Form B
27.5
3.6±0.5
2x 2.1
27.8
0.8(两处)
6.4(两处)
(Bottom view)
(Top view)
2x 1.1
3.8
14
17.8
1 Form C
27.5
3.6±0.5
27.8
3x 2.1
0.8(三处)
6.4(三处)
(Bottom view)
(Top view)
2x 1.1
3.8
14
17.8
Remark: 1) In case of no tolerance shown in outline dimension: outline dimension ≤1mm, tolerance should be ±0.2mm; outline dimension >1mm
and ≤5mm, tolerance should be ±0.3mm; outline dimension >5mm, tolerance should be ±0.4mm.
2) The tolerance without indicating for PCB layout is always ±0.1mm.
317
CHARACTERISTIC CURVES
MAXIMUM SWITCHING POWER
100
40
30
20
15
ENDURANCE CURVE
COIL TEMPERATURE RISE
110
100
DC Coil
1A
1C (NO)
100
30
1A
90
1B
10
1C (NO)
1C (NC)
80
1C (NC)
10
1B
70
30A
60
1
AC Resistive
Load
15A
40
DC Resistive
1 Load
10
25A
20A
50
0A
100
200
1000
Contact Voltage (V)
0
10
20
30
40
Contact Current (A)
0
80
90
100
110
120
130
140
150
160
Percentage Of Nominal Coil Voltage
Test conditions:
Resistive load, Dust protected,
AgCdO, Room temp., 1s on 9s off.
Disclaimer
The specification is for reference only. See to "Terminology and Guidelines" for more information. Specifications subject to change without notice.
We could not evaluate all the performance and all the parameters for every possible application. Thus the user should be in a right position to
choose the suitable product for their own application. If there is any query, please contact Hongfa for the technical service. However, it is the user’s
responsibility to determine which product should be used only.
© Xiamen Hongfa Electroacoustic Co., Ltd. All rights of Hongfa are reserved.
318
HF105F-2/012D-1HSF(257) 价格&库存
很抱歉,暂时无法提供与“HF105F-2/012D-1HSF(257)”相匹配的价格&库存,您可以联系我们找货
免费人工找货