HF105F-4/024DK-1HTF(257) 数据手册
H F1 0 5F- 4
MINIATURE HIGH POWER RELAY
Features
File No.:E134517
● 40A switching capability
● 2.5kV dielectric strength
V
D E
(between coil and contacts)
File No.:40025518 (DC type)
● Heavy load up to 7200VA
File No.:CQC09002031229(DC type)
CQC10002049165(DC type)
RoHS compliant
COIL
CONTACT DATA
Contact
arrangement
Contact
resistance1)
1A
1B
1C (NO)
DC type: Approx. 900mW;
AC type: Approx. 2VA
Coil power
50m max.(at 1A 24VDC)
AgSnO2, AgCdO
Contact material
Max. switching
capacity
Max. switching
voltage
Max. switching
current
1C (NC)
7200VA/560W 3600VA/280W 4800VA/560W 2400VA/280W
Max.continuous
current
HF105F-4
rating
HF105F-4L
rating
Mechanical
endurance
SAFETY APPROVAL RATINGS
30A 277VAC
277VAC/28VDC
40A2)
15A
20A
10A
1 Form A
≤25A
2HP 250VAC
AgCdO
28A 277VAC
25A 240VAC 15A 240VAC 20A 240VAC 10A 240VAC
20A 28VDC 10A 28VDC 20A 28VDC 10A 28VDC
277VAC(FLA=20)(LRA=60)
AgCdO
15A 277VAC
10A 28VDC
1/2HP 250VAC
1/4HP 125VAC
277VAC(FLA=10)(LRA=33)
AgSnO2
AgCdO
2HP 250VAC
AgCdO
20A 277VAC
1 x 107OPS
5
1H type(Non-plastic sealed): 1 x 10 OPS
(28A 277VAC, Resistive load,
AgCdO, Room temp., 1s on 9s off)
UL/
CUL
1 Form B
Notes:1) The data shown above are initial values.
2) Long time current-carrying under 40A condition is prohibited.
CHARACTERISTICS
Insulation resistance
1000M (at 500VDC)
Dielectric Between coil & contacts
strength Between open contacts
1500VAC 1min
DC type: 15ms max.
Release time (at rated. volt.)
DC type: 10ms max.
DC: -55 to 85
AC: -55 to 60
98m/s2
Ambient temperature
Shock resistance
Vibration resistance
Functional
Destructive
NO
2500VAC 1min
Operate time (at rated. volt.)
30A 277VAC
1HP 125VAC
20A 28VDC
277VAC(FLA=20)(LRA=60)
1 Form C
AgSnO2
AgCdO
20A 277VAC
1/2HP 250VAC
1/4HP 125VAC
NC
980m/s2
10Hz to 55Hz 1.5mm DA
1HP 125VAC
30A 28VDC
30A 240VAC 15A 240VAC 20A 240VAC 10A 240VAC
20A 28VDC 10A 28VDC 20A 28VDC 10A 28VDC
Electrical
endurance
40A 277VAC
AgSnO2
AgCdO
10A 277VAC
AgCdO
10A 28VDC
5% to 85% RH
277VAC(FLA=10)(LRA=33)
Termination
QC
Unit weight
Approx. 36g
Plastic sealed,
Dust protected
Notes: 1) All values unspecified are at room temperature.
2) Only typical loads are listed above. Other load specifications
can be available upon request.
Humidity
Construction
Notes: 1) For plastic sealed type, the venting-hole should be opened in
test.
2) The data shown above are initial values.
3) Please find coil temperature curve in the characteristic curves below.
4) UL insulation system: Class F, Class B.
HONGFA RELAY
ISO9001, ISO/TS16949 , ISO14001, OHSAS18001, IECQ QC 080000 CERTIFIED
2019 Rev. 1.00
319
COIL DATA
at 23
DC type
AC type
Nominal
Voltage
VDC
Pick-up
Voltage
VDC
max.3)
Drop-out
Voltage
VDC
min.3)
Max.
Voltage
VDC *4)
5
3.75
0.5
6.5
27 x (1 10%)
12
6
4.50
0.6
7.8
40 x (1 10%)
24
Coil
Resistance
Nominal Pick-up
Voltage Voltage
VAC
VAC
max.3)
Drop-out
Voltage
VAC
min.3)
Max.
Voltage
VDC* 4)
9.6
2.4
15.6
25 x (1 10%)
19.2
4.8
31.2
100 x (1 10%)
Coil
Resistance
9
6.75
0.9
11.7
97 x (1 10%)
120
96.0
24.0
156
2500 x (1 10%)
12
9.00
1.2
15.6
155 x (1 10%)
208
166.4
41
270.4
11000 x (1 10%)
15
11.25
1.5
19.5
256 x (1 10%)
220
176
44
286
13490 x (1 10%)
18
13.50
1.8
23.4
380 x (1 10%)
240
192
48
286
13490 x (1 10%)
24
18.00
2.4
31.2
660 x (1 10%)
277
220
54
360.1
15000 x (1 10%)
48
36.00
4.8
62.4
2560 x (1 10%)
70
52.50
7.0
91
5500 x (1 10%)
110
82.50
11
143
13450 x (1 10%)
Notes: 1) When requiring pick-up voltage < 80% of nominal voltage,
special order allowed.
2) The data shown above are initial values at 50Hz. When
requiring 60Hz, special order allowed.
3) The data shown above are initial values.
4) *Maximum voltage refers to the maximum voltage which
relay coil could endure in a short period of time.
ORDERING INFORMATION
HF 1 05F -4 /
Type
018
D
K - 1H S
T
F (XXX)
HF105F-4: 30A
HF105F-4L: 25A
Coil voltage
DC: 5VDC to 110VDC
AC: 12VAC to 277VAC
Coil voltage form
D: DC
Coil terminal width
K: 4.8mm
A: AC
Nil: 2.8mm
Contact arrangement 1H:1 Form A 1D:1 Form B 1Z:1 Form C
Construction 1)
S: Plastic sealed
Contact material
T: AgSnO2
Nil: AgCdO
Insulation standard
F: Class F
Nil: Class B
Special code3)
XXX: Customer special requirement
Nil: Dust protected
Nil: Standard
Notes: 1) We recommend dust protected types for a clean environment (free from contaminations like H2S, SO2, NO2, dust, etc.).
We suggest to choose plastic sealed types and validate it in real application for an unclean environment (with contaminations
like H2S, SO2, NO2, dust, etc.).
2) Contact is recommended for suitable condition and specifications if water cleaning or surface process is involved in assembling relays
on PCB.
3) The customer special requirement express as special code after evaluating by Hongfa.
320
OUTLINE DIMENSIONS, WIRING DIAGRAM AND PC BOARD LAYOUT
Unit: mm
1 Form A
Outline Dimensions
Wiring Diagram
(Top view)
2.8mm Terminal width
27.2
27.8
2x6.4
2.2
2x2.8
3.5
4.8mm Terminal width
27.2
27.8
2x6.4
2.2
2x4.8
3.5
1 Form B
2.8mm Terminal width
27.2
27.8
2x6.4
2.2
2x2.8
3.5
4.8mm Terminal width
27.2
27.8
2x6.4
2.2
2x4.8
3.5
321
OUTLINE DIMENSIONS, WIRING DIAGRAM AND PC BOARD LAYOUT
Unit: mm
1 Form C
Outline Dimensions
Wiring Diagram
(Top view)
2.8mm Terminal width
27.2
27.8
3x6.4
2.2
2x2.8
3.5
4.8mm Terminal width
27.2
27.8
3x6.4
2.2
2x4.8
3.5
Remark: In case of no tolerance shown in outline dimension: outline dimension ≤1mm, tolerance should be ±0.2mm; outline dimension >1mm
and ≤5mm, tolerance should be ±0.3mm; outline dimension >5mm, tolerance should be ±0.4mm.
CHARACTERISTIC CURVES
100
COIL TEMPERATURE RISE
ENDURANCE CURVE
MAXIMUM SWITCHING POWER
100
DC Coil
1A
40
1C (NO)
30
1B
20
1C (NC)
15
110
30
100
1A
90
10
1C (NO)
1C (NC)
10
80
1B
70
30A
1
AC Resistive
Load
60
25A
20A
50
DC Resistive
1 Load
10
15A
40
100
200
1000
Contact Voltage (V)
0
0A
10
20
30
40
Contact Current (A)
Test conditions:
Resistive load, Dust protected,
AgCdO, Room temp., 1s on 9s off.
0
80
90
100
110
120
130
140
150
160
Percentage Of Nominal Coil Voltage
Disclaimer
The specification is for reference only. See to "Terminology and Guidelines" for more information. Specifications subject to change without notice.
We could not evaluate all the performance and all the parameters for every possible application. Thus the user should be in a right position to
choose the suitable product for their own application. If there is any query, please contact Hongfa for the technical service. However, it is the user’s
responsibility to determine which product should be used only.
© Xiamen Hongfa Electroacoustic Co., Ltd. All rights of Hongfa are reserved.
322
HF105F-4/024DK-1HTF(257) 价格&库存
很抱歉,暂时无法提供与“HF105F-4/024DK-1HTF(257)”相匹配的价格&库存,您可以联系我们找货
免费人工找货