HF115F-H/009-1HS1B(257) 数据手册
HF115 F -H
MINIATURE HIGH POWER RELAY
Features
●
●
●
●
●
●
●
●
File No.:E134517
V
D E
File No.:116934
High sensitive: 0.25W
Low height: 15.7 mm
5kV dielectric strength (between coil and contacts)
Creepage distance: 10mm
Meeting VDE 0700, 0631 reinforce insulation
Product in accordance to IEC 60335-1 available
Sockets available
Plastic sealed and flux proofed types available
File No.:CQC17002168381
RoHS compliant
CONTACT DATA
COIL
Contact arrangement
1A, 1B, 1C
Contact resistance
Coil power
Approx. 250mW
100m max.(at 1A 6VDC)
Contact material
See ordering info.
Contact rating
(Sensitive coil)
10A 250VAC
Max. switching voltage
440VAC / 300VDC
Max. switching current
10A
Pick-up Drop-out
Voltage Voltage
VDC
VDC
min. 1)
max. 1)
Max.
Voltage
VDC 2)
Coil
Resistance
5
3.75
0.5
7.5
100 x (1 10%)
1 x 107OPS
1H3 type: 1 x 10 OPS (10A 250VAC,
Resistive load, at 85 C, 5s on 5s off)
6
4.50
0.6
9.0
144 x (1 10%)
12
9.00
1.2
18
576 x (1 10%)
18
13.50
1.8
27
1296 x (1 10%)
24
18.00
2.4
36
2304 x (1 10%)
3)
36.00
4.8
72
9216 x (1 15%)
3)
45.00
6.0
90
12857 x (1 15%)
5
Electrical endurance
Nominal
Voltage
VDC
at 23
2500VA
Max. switching power
Mechanical endurance
COIL DATA
o
Notes: 1) The data shown above are initial values.
CHARACTERISTICS
Insulation resistance
1000M (at 500VDC)
Dielectric Between coil & contacts
strength
5000VAC 1min
Between open contacts
Surge voltage (between coil & contacts)
1000VAC 1min
10kV (1.2 / 50µs)
Operate time (at nomi. volt.)
15ms max.
Release time (at nomi. volt.)
8ms max.
Temperature rise (at nomi. volt.)
55K max.
Shock resistance *
Functional
98m/s2
Destructive
980m/s2
Vibration resistance *
48
60
Notes: 1) The data shown above are initial values.
2)Maximum voltage refers to the maximum voltage which relay
coil could endure in a short period of time.
3) For products with rated voltage ≥ 48V, measures should be
taken to prevent coil overvoltage in order to protect coil in test
and application (eg. Connect diodes in parallel).
10Hz to 150Hz 10g/5g
Humidity
5% to 85% RH
Ambient temperature
Termination
-40
to 85
PCB
Unit weight
Approx. 13.5g
Construction
Plastic sealed,
Flux proofed
Notes: 1) The data shown above are initial values.
2) * Index is not that of relay length direction.
3) UL insulation system: Class F, Class B.
HONGFA RELAY
ISO9001, ISO/TS16949 , ISO14001, OHSAS18001, IECQ QC 080000 CERTIFIED
2020 Rev. 1.00
223
SAFETY APPROVAL RATINGS
VDE
Contact Material
Specifications
Ratings
AgSnO2
HF115F-H….1(H;Z)(S)(1;2;3)A(G)(F)
AgCdO
HF115F-H….1(H;Z)(S)(1;2;3)(G)(F)
10A 250VAC at 85°C
10A 250VAC at 85°C
6A 400VAC at 85°C
UL/CUL
Contact Material
Specifications
Ratings
HF115F-H….1(H;Z)(S)(1;2;3)(G)(F)
AgCdO
10A 250VAC
Notes: 1) All values unspecified are at room temperature.
2) Only typical loads are listed above. Other load specifications can be available upon request.
ORDERING INFORMATION
H F 11 5F -H /
0 12
-1H
S
3
A
F (XXX)
Type
Coil voltage
5, 6, 12, 18, 24, 48, 60VDC
Contact arrangement 1H:1 Form A 1D:1 Form B 1Z:1 Form C
Construction 1) 2)
S: Plastic sealed
Version
1: 3.5mm 1 pole
Contact materia
3)
Nil: Flux proofed
2: 5.0mm 1 pole
A: AgSnO2
B: AgNi
AG: AgSnO2+Au plated
3: 5.0mm 1 pole
Nil: AgCdO
G: AgCdO+Au plated
BG: AgNi+Au plated
Insulation standard
F: Class F
Special code4)
XXX: Customer special requirement
Nil: Class B
Nil: Standard
Notes: 1) We recommend flux proofed types for a clean environment (free from contaminations like H2S, SO2, NO2, dust, etc.).
We suggest to choose plastic sealed types and validate it in real application for an unclean environment (with contaminations
like H2S, SO2, NO2, dust, etc.).
2) Contact is recommended for suitable condition and specifications if water cleaning or surface process is involved in assembling relays
on PCB.
3) For gold plated type, the min. switching current and min. switching voltage is 10mA 5VDC.
4) The customer special requirement express as special code after evaluating by Hongfa. e.g.(335) stands for product in accordance to
IEC 60335-1 (GWT).
5) Two packing methods available: plastic tray package, tube package,Standard tube packing length is 616mm. Any special requirement
needed, please contact us for more details.
6) For products that should meet the explosion-proof requirements of "IEC 60079 series",please note [Ex] after the specification while
placing orders.Not all products have explosion-proof certification,so please contact us if necessary, in order to select the suitable products.
OUTLINE DIMENSIONS, WIRING DIAGRAM AND PC BOARD LAYOUT
Unit: mm
Outline Dimensions
3.5mm Pinning (HF115F-H/ □□□ -□□ -1-□)
12.7
0.5x0.5
224
3x0.5x0.8
5mm Pinning (HF115F-H/ □□□ -□□-2/3-□)
12.7
0.3
0.5x0.5
6x0.5x0.8
0.3
OUTLINE DIMENSIONS, WIRING DIAGRAM AND PC BOARD LAYOUT
Unit: mm
PCB Layout (Bottom view)
3.5mm Pinning, 1 Pole
5mm Pinning, 1 Pole
5.04
3.5
2.6
3.5
2.6
5.04
5.04
2.6
7.56
7.56
5x 1.3
5mm Pinning, 1 Pole
5x 1.3
20.16
5.04
7.56
20.16
8x 1.3
20.16
Wiring Diagram (Bottom view)
3.5/5mm Pinning, 1 Pole, 10A, HF115F-H/ □□□ -□□ -□ -1/2 -□
1 Form A
1 Form B
1 Form C
5mm Pinning, 1 Pole, 10A, HF115F-H/ □□□ -□□ -□ -3 -□
1 Form A
1 Form B
1 Form C
Remark: 1) In case of no tolerance shown in outline dimension: outline dimension ≤1mm, tolerance should be ±0.2mm; outline dimension >1mm
and ≤5mm, tolerance should be ±0.3mm; outline dimension >5mm, tolerance should be ±0.4mm.
2) The tolerance without indicating for PCB layout is always ±0.1mm.
3) The width of the gridding is 2.52mm.
CHARACTERISTIC CURVES
COIL OPERATING RANGE (DC) *
ENDURANCE CURVE
1000
3.6
3.4
3.0
100
2.6
2.2
1.8
10
10 A
1.4
Recommended
voltage
1.0
0.6
1
0
0
2
Notes:
4
6
8
10
12
14
16
Contact Current (A)
1) Curve : 1H3 type
2) Test conditions:
NO, 250VAC, Resistive load,
o
Flux proofed, at 85 C, 5s on 5s off.
20
40
60
80 85
Ambient Temperature (
100
)
Notes: * The use of a relay with an energising voltage
other than the rated coil voltage may lead to
reduced electrical life.
An energising voltage over the abver range
may damage the insulation of relay coil.
Disclaimer
The specification is for reference only. See to "Terminology and Guidelines" for more information. Specifications subject to change without notice.
We could not evaluate all the performance and all the parameters for every possible application. Thus the user should be in a right position to
choose the suitable product for their own application. If there is any query, please contact Hongfa for the technical service. However, it is the user’s
responsibility to determine which product should be used only.
© Xiamen Hongfa Electroacoustic Co., Ltd. All rights of Hongfa are reserved.
225