Features
●
●
●
●
●
●
●
●
●
File No.:E134517
V
D E
File No.:116934
Max high inrush:120A 20ms
Low height: 15.7 mm
5kV dielectric strength (between coil and contacts)
Creepage distance: 10mm
Meeting VDE 0700, 0631 reinforce insulation
Product in accordance to IEC 60335-1 available
Sockets available
Plastic sealed and flux proofed types available
UL insulation system: Class F
File No.:CQC17002168381
RoHS compliant
CONTACT DATA
COIL
Contact arrangement
1A, 1C
Contact resistance 1)
Contact material
AgSnO2
Contact rating
16A 250VAC
NO: TV-5 80A
120A / 20ms
Approx. 400mW
COIL DATA
at 23
Nominal
Voltage
VDC
Pick-up
Voltage
VDC
max.1)
Drop-out
Voltage
VDC
min.1)
Max.
Voltage
VDC 2)
5
3.50
0.5
7.5
62 x (1 10%)
6
4.20
0.6
9.0
90 x (1 10%)
9
6.30
0.9
13.5
202 x (1 10%)
12
8.40
1.2
18
360 x (1 10%)
18
12.6
1.8
27
810 x (1 10%)
24
16.8
2.4
36
1440 x (1 10%)
483)
33.6
4.8
72
5760 x (1 15%)
1000M (at 500VDC)
60 3)
42.0
6.0
90
7500 x (1 15%)
Between coil & contacts
5000VAC 1min
3)
77.0
11.0
165
25200 x (1 15%)
Between open contacts
1000VAC 1min
Inrush rating (120VAC)
Max. switching voltage
440VAC / 300VDC
Max. switching current
16A
Max. switching power
4000VA
Mechanical endurance
Electrical endurance
1 x 107OPS
1H3A type: 7.5 x 104OPS (16A 250VAC,
General use, Room temp.,
1s on 9s off)
1H3A type: 2.5 x 104OPS (TV-5 120VAC,
Room temp., 1s on 59s off)
Notes: 1) The data shown above are initial values.
CHARACTERISTICS
Insulation resistance
Dielectric
strength
Coil power
100m max.(at 1A 6VDC)
Surge voltage (between coil & contacts)
10kV (1.2 / 50µs)
Operate time (at nomi. volt.)
15ms max.
Release time (at nomi. volt.)
8ms max.
Temperature rise (at nomi. volt.)
55K max.
Functional
98m/s2
Destructive
980m/s2
Shock resistance *
Vibration resistance *
10Hz to 150Hz 20g/5g
Humidity
110
Notes: 1) The data shown above are initial values.
Notes: 2) Maximum voltage refers to the maximum voltage which relay
coil could endure in a short period of time.
3) For products with rated voltage ≥ 48V, measures should be
taken to prevent coil overvoltage in order to protect coil in
test and application (eg. Connect diodes in parallel).
SAFETY APPROVAL RATINGS
HF115F-I....1Z(S)3A
UL/CUL
HF115F-I....1H(S)3A
5% to 85% RH
Ambient temperature
-40
PCB
Unit weight
Approx. 13.5g
Plastic sealed,
Flux proofed
Notes: 1) The data shown above are initial values.
2) * Index is not that of relay length direction.
16A 250VAC
TV-5,120VAC
HF115F-I....1H(S)3A
16A 250VAC at 85°C
HF115F-I....1Z(S)3A
NO: 16A 250VAC at 85°C
VDE
Notes: 1) All values unspecified are at room temperature.
2) Only typical loads are listed above. Other load specifications
can be available upon request.
HONGFA RELAY
ISO9001, ISO/TS16949 , ISO14001, OHSAS18001, IECQ QC 080000 CERTIFIED
226
NO: 16A 250VAC at 85°C
to 85
Termination
Construction
Coil
Resistance
2020 Rev. 1.00
ORDERING INFORMATION
HF 115 F - I /
0 1 2 -1 H
S
3
A
(XXX)
Type
Coil voltage
5, 6, 9, 12, 18, 24, 48, 60, 110VDC
Contact arrangement
Construction
1)2)
1H: 1 Form A
1Z: 1 Form C
S: Plastic sealed
Nil: Flux proofed
Version
3: 5.0mm
Contact material
A: AgSnO2
Special code3)
XXX: Customer special requirement
Nil: Standard
Notes: 1) We recommend flux proofed types for a clean environment (free from contaminations like H2S, SO2, NO2, dust, etc.).
We suggest to choose plastic sealed types and validate it in real application for an unclean environment (with contaminations
like H2S, SO2, NO2, dust, etc.).
2) Contact is recommended for suitable condition and specifications if water cleaning or surface process is involved in assembling relays
on PCB.
3) The customer special requirement express as special code after evaluating by Hongfa. e.g.(335) stands for product in accordance to
IEC 60335-1 (GWT).
4) Two packing methods available: plastic tray package, tube package,Standard tube packing length is 616mm. Any special requirement
needed, please contact us for more details.
5) For products that should meet the explosion-proof requirements of "IEC 60079 series",please note [Ex] after the specification while placing
orders.Not all products have explosion-proof certification,so please contact us if necessary, in order to select the suitable products.
OUTLINE DIMENSIONS, WIRING DIAGRAM AND PC BOARD LAYOUT
Unit: mm
Outline Dimensions
12.7
6x0.5x0.8
0.5x0.5
7.56
0.3
PCB Layout
Wiring Diagram
(Bottom view)
(Bottom view)
5.04
2.6
1 Form A
1 Form A
6x 1.3
20.16
5.04
7.56
5.04
2.6
1 Form C
1 Form C
8x 1.3
20.16
Remark: 1) In case of no tolerance shown in outline dimension: outline dimension ≤1mm, tolerance should be ±0.2mm; outline dimension >1mm
and ≤5mm, tolerance should be ±0.3mm; outline dimension >5mm, tolerance should be ±0.4mm.
2) The tolerance without indicating for PCB layout is always ±0.1mm.
3) The width of the gridding is 2.52mm.
227
CHARACTERISTIC CURVES
ENDURANCE CURVE
COIL OPERATING RANGE (DC) *
3.6
1000
3.4
3.0
100
2.6
2.2
16 A
1.8
10
1.4
Recommended
voltage
1.0
1
0.6
0
2
4
6
8
10
12
14
16
Contact Current (A)
Test conditions:
NO, 250VAC, Resistance Load,
Flux proofed, Room temp., 1s on 9s off
0
+20
+40
+60
+80
+100
Ambient Temperature ( )
Notes: * The use of a relay with an energising voltage
other than the rated coil voltage may lead to
reduced electrical life.
An energising voltage over the abover range
may damage the insulation of relay coil.
Disclaimer
The specification is for reference only. See to "Terminology and Guidelines" for more information. Specifications subject to change without notice.
We could not evaluate all the performance and all the parameters for every possible application. Thus the user should be in a right position to
choose the suitable product for their own application. If there is any query, please contact Hongfa for the technical service. However, it is the user’s
responsibility to determine which product should be used only.
© Xiamen Hongfa Electroacoustic Co., Ltd. All rights of Hongfa are reserved.
228