HF115F-L/12-ZS3L2TF(257) 数据手册
HF115F-L 1 pole
MINIATURE HIGH POWER LATCHING RELAY
Features
●
●
●
●
File No.:E134517
V
D E
●
●
●
●
File No.:116934
Latching relay
Low height: 15.7 mm
20A switching capability
5kV dielectric strength
(between coil and contacts)
Creepage distance: 11mm-NO/10mm-CO version
Meeting VDE 0700, 0631 reinforce insulation
Product in accordance to IEC 60335-1 available
UL insulation system: Class F
File No.: CQC17002176310
RoHS compliant
CONTACT DATA
COIL DATA
Contact arrangement
Contact resistance1)
Contact material
1A, 1C
100m max.(at 1A 6VDC)
AgSnO2
16A 250VAC
Contact rating (Res. load)
Incandescent lamp:1500W 277VAC
Typ. applicable load
Standard ballast:8A 277VAC
Electronic ballast: 5A 120VAC
Max. switching voltage
480VAC / 300VDC
Max. switching current
20A
Max. switching power
4000VA
2 x 106OPS
Mechanical endurance
5 x 104OPS (NO: 16A 250VAC,
Resistive load, at 85 C, 1s on 9s off)
Electrical endurance
o
Notes: 1) The data shown above are initial values.
CHARACTERISTICS
Insulation resistance
1000M (at 500VDC)
Dielectric Between coil & contacts
strength Between open contacts
5000VAC 1min
1000VAC 1min
Surge voltage (between coil & contacts)
10kV (1.2 / 50µs)
Set time (at nomi. volt.)
10ms max.
Reset time (at nomi. volt.)
10ms max.
Shock resistance *
Vibration resistance *
Functional
98m/s2
Destructive
980m/s2
-40
PCB
Unit weight
Approx. 13.5g
Plastic sealed,
Flux proofed
Construction
Notes: 1) The data shown above are initial values.
2) * Index is not in relay length direction.
COIL
Coil power
≥50
30
3.5
6
62x (1 10%)
6
4.2
≥50
30
4.2
7.2
90x (1 10%)
9
6.3
≥50
30
6.3
10.8
202x (1 10%)
12
8.4
≥50
30
8.4
14.4
360x (1 10%)
24
16.8
≥50
30
16.8
1 coil latching: Approx. 400mW
2 coils latching: Approx. 600mW
28.8 1440x (1 10%)
2 coils latching
Nominal Set Pulse Width Reset Max.
Voltage Voltage
(ms)
Voltage Voltage
VDC VDC
VDC
VDC
Typical
Min.
max.1)
max.1)
Coil
Resistance
5
3.5
≥50
30
3.5
7.5
42x (1 10%)
6
4.2
≥50
30
4.2
9
55x (1 10%)
9
6.3
≥50
30
6.3
13.5
135x (1 10%)
12
8.4
≥50
30
8.4
18
240x (1 10%)
24
16.8
≥50
30
16.8
36
886x (1 10%)
Notes: 1) The data shown above are initial values.
2) *Maximun voltage refers to the maximun voltage which relay
coil could endure in a short period of time.
SAFETY APPROVAL RATINGS
to 85
Termination
Coil
Resistance
3.5
5% to 85% RH
Ambient temperature
Reset Max.
Voltage Voltage
VDC VDC
max.1)
5
10Hz to 150Hz 10g/5g
Humidity
at 23
1 coil latching
Nominal Set Pulse Width
(ms)
Voltage Voltage
VDC
VDC
Typical Min.
max.1)
UL/CUL
VDE
16A/20A 250VAC 85
1HP 240VAC 40
TV-8 240VAC 40
TV-12 120VAC 40 (1 Form A)
Tungsten 360W 125VAC 40 (1 Form A)
Tungsten 1920W 8A 240VAC 40
Tungsten 12A 120VAC 40
Standard ballast 16A 120VAC 40
Standard ballast 8A 277VAC 40
Standard ballast 5A 347VAC/480VAC 40
Electronic ballast 5A 120VAC 40
16A 250VAC at 85
AC-15 240VAC at 85
Notes: 1) All values unspecified are at room temperature.
2) Only typical loads are listed above. Other load specifications
can be available upon request.
HONGFA RELAY
ISO9001, IATF16949 , ISO14001, ISO45001, IECQ QC 080000, ISO/IEC 27001 CERTIFIED
2023 Rev. 2.00
215
ORDERING INFORMATION
H F115 F -L / 1 2
-Z
S
3
L1
F
T
(XXX)
Type
Coil voltage
5, 6, 9,12, 24VDC
Contact arrangement H: 1 Form A Z: 1 Form C
1) 2)
Construction
S: Plastic sealed
Version
3: 5.0mm 1 pole 16A
Sort
L1: 1 coil latching L2: 2 coils latching
Contact material
T: AgSnO2
Insulation standard
F: Class F
Special code4)
XXX: Customer special requirement
Nil: Flux proofed
Nil: Standard
Notes: 1) We recommend flux proofed types for a clean environment (free from contaminations like H2S, SO2, NO2, dust, etc.).
We suggest to choose plastic sealed types and validate it in real application for an unclean environment (with contaminations like H2S,
SO2, NO2, dust, etc).
2) Contact is recommended for suitable condition and specifications if water cleaning or surface process is involved in assembling relays
on PCB.
3) The customer special requirement express as special code after evaluating by Hongfa. e.g.(335) stands for product in accordance to
IEC 60335-1 (GWT).
4) Two packing methods available: plastic tray package, tube package,Standard tube packing length is 616mm. Any special requirement
needed, please contact us for more details.
5) For products that should meet the explosion-proof requirements of "IEC 60079 series",please note [Ex] after the specification while placing
orders.Not all products have explosion-proof certification,so please contact us if necessary, in order to select the suitable products.
OUTLINE DIMENSIONS, WIRING DIAGRAM AND PC BOARD LAYOUT
Unit: mm
Outline Dimensions
1 coil latching
29
2 coils latching
12.7
0.3
29
0.3
0.3
12.7
0.3
12.7
0.3
1 Form A
2x□0.5
29
3x□0.5
4x0.5x0.8
12.7
0.3
4x0.5x0.8
0.3
29
0.3
1 Form C
2x□0.5
216
6x0.5x0.8
3x□0.5
6x0.5x0.8
OUTLINE DIMENSIONS, WIRING DIAGRAM AND PC BOARD LAYOUT
Unit: mm
Wiring Diagram
(Bottom view)
1 coil latching(Reset Status)
+
1 Form A
1 Form C
①
⑧
2 coils latching(Set Status)
-
③
+
①
set
⑤
⑨
⑧
⑥
⑤
⑥
1 coil latching(Reset Status)
1 Form A
1 Form C
-
①
⑧
⑦
+
③
⑤
⑥
-
①
⑧
⑦
reset
④
③
⑤
-
③
⑤
⑥
+
②
⑨
⑧
⑦
-
③
④
⑤
⑥
-
①
+
②
⑧
⑦
⑤
⑥
⑨
⑧
⑦
④
⑤
⑥
③
reset
reset
+
⑦
2 coils latching(Reset Status)
reset
⑨
②
①
set
④
③
+
⑦
set
-
⑧
①
⑦
set
-
①
+
②
③
⑥
PCB Layout
(Bottom view)
2 coils latching
1 coil latching
5.04
2.6
5.04
2.6
1 Form A
6x 1.3
20.16
7x 1.3
20.16
217
OUTLINE DIMENSIONS, WIRING DIAGRAM AND PC BOARD LAYOUT
Unit: mm
PCB Layout
(Bottom view)
2 coils latching
1 coil latching
5.04
5.04
2.6
2.6
5.04
5.04
1 Form C
8x 1.3
20.16
9x 1.3
20.16
Remark: 1) In case of no tolerance shown in outline dimension: outline dimension ≤1mm, tolerance should be ±0.2mm; outline dimension >1mm
and ≤5mm, tolerance should be ±0.3mm; outline dimension >5mm, tolerance should be ±0.4mm.
2) The tolerance without indicating for PCB layout is always ±0.1mm.
3) The width of the gridding is 2.52mm.
Notice
1. Relay is on the “reset” status when being released from stock, with the consideration of shock risen from transit and relay mounting, relay would
be changed to “set” status, therefore, when application ( connecting the power supply), please reset the relay to “set” or “reset” status on request.
2. In order to maintain “set” or “reset” status, energized voltage to coil should reach the rated voltage. Do not energize voltage to “set” coil and “reset”
coil simultaneously. And also long energized time (more than 1 min) should be avoided.
3. Keep the product away from strong magnetic field during transportation, storage and application, to avoid change of set/reset voltage.
Disclaimer
The specification is for reference only. See to "Terminology and Guidelines" for more information. Specifications subject to change without notice.
We could not evaluate all the performance and all the parameters for every possible application. Thus the user should be in a right position to
choose the suitable product for their own application. If there is any query, please contact Hongfa for the technical service. However, it is the user’s
responsibility to determine which product should be used only.
© Xiamen Hongfa Electroacoustic Co., Ltd. All rights of Hongfa are reserved.
218
HF115F-L/12-ZS3L2TF(257) 价格&库存
很抱歉,暂时无法提供与“HF115F-L/12-ZS3L2TF(257)”相匹配的价格&库存,您可以联系我们找货
免费人工找货