HF115F-S/12-HSF(257) 数据手册
HF 115 F -S
MINIATURE HIGH POWER RELAY
Features
File No.:E134517
●
●
●
●
●
●
●
●
V
D E
File No.:116934
Special contact struction
Incandescent lamp load: 3000W 230VAC
5kV dielectric strength (between coil and contacts)
Creepage distance: 11mm
Low height: 15.7 mm
Meeting reinforce insulation
Product in accordance to IEC 60335-1 available
Plastic sealed and flux proofed types available
File No.:CQC17002168381
CONTACT DATA
COIL
Contact arrangement
1A
Contact resistance 1)
Coil power
Approx. 400mW
100m max.(at 1A 6VDC)
Contact material
W+AgSnO2
Resistive:16A 250VAC
Incandescent Lamp: 3000W 230VAC
Inrush current: 165A / 20ms
LED(Electronic ballast): 492A/1.5ms
Contact rating
COIL DATA
at 23
Nominal
Voltage
VDC
Pick-up
Voltage
VDC
max.1)
Drop-out
Voltage
VDC
1)
min.
Max.
Voltage
VDC 2)
5
3.50
0.5
7.5
62 x (1 10%)
Coil
Resistance
Max. switching voltage
440VAC
Max. switching current
Max. switching power
16A
6
4.20
0.6
9.0
90 x (1 10%)
4000VA
9
6.30
0.9
13.5
202 x (1 10%)
12
8.40
1.2
18
360 x (1 10%)
18
12.6
1.8
27
810 x (1 10%)
16.8
2.4
36
1440 x (1 10%)
33.6
4.8
72
5760 x (1 15%)
42.0
6.0
90
7500 x (1 15%)
77.0
11.0
165
25200 x (1 15%)
Mechanical endurance
Electrical endurance
5 x 106OPS
4
1.2 x 10 OPS (3000W 230VAC,
Incand escentlamp load, Room temp.,
1s on 11s off)
Notes:1) The data shown above are initial values.
24
CHARACTERISTICS
Insulation resistance
Dielectric
strength
1000M (at 500VDC)
Between coil & contacts
5000VAC 1min
Between open contacts
1250VAC 1min
Surge voltage (between coil & contacts)
10kV (1.2 / 50µs)
Operate time (at rated. volt.)
10ms max.
Release time (at rated. volt.)
5ms max.
Temperature rise (at rated. volt.)
55K max.
Functional
98m/s2
Destructive
980m/s2
Shock resistance *
Vibration resistance *
60
110
3)
3)
Notes:1) The data shown above are initial values.
2) Maximum voltage refers to the maximum voltage which relay
coil could endure in a short period of time.
3) For products with rated voltage ≥ 48V, measures should be
taken to prevent coil overvoltage in order to protect coil in test
and application (eg. Connect diodes in parallel).
SAFETY APPROVAL RATINGS
VDE
5% to 85% RH
Humidity
Ambient temperature
Termination
10Hz to 150Hz 10g
48
3)
-40
to 85
PCB
Unit weight
Approx. 13.5g
Construction
Plastic sealed,
Flux proofed
Notes:1) This contact resistance value is tested under the norminal
voltage.
2) * Index is not that of relay length direction.
3) The data shown above are initial values.
4) UL insulation system: Class F, Class B.
UL/CUL
16A 250VAC at 85°C
16A 250VAC at 85°C
Incandescent lamp 3000W 230VAC
TV-8 120VAC
Incandescent lamp 1200W 120VAC at 50°C
Incandescent lamp 1200W 277VAC at 50°C
Standard ballast 2.2A 277VAC at 50°C
Electronic ballast 16A 277/120VAC 85°C
Electronic ballast 12A 277/120VAC 85°C
Electronic ballast 8A 277/347VAC 85°C
Electronic ballast 15A 120VAC 85°C3)
Electronic ballast 8A 277/347VAC 85°C3)
Notes: 1) All values unspecified are at room temperature.
2) Only typical loads are listed above. Other load specifications
can be available upon request.
3) Zero crossing control cooperative.
HONGFA RELAY
ISO9001, IATF16949 , ISO14001, ISO45001, IECQ QC 080000, ISO/IEC 27001 CERTIFIED
2023 Rev. 2.00
213
ORDERING INFORMATION
H F 11 5F -S /
12
-H
S
F
(XXX)
Type
Coil voltage
5, 6, 9, 12, 18, 24, 48, 60, 110VDC
Contact arrangement
H: 1 Form A
Construction1) 2)
S: Plastic sealed
Insulation Standard
F: Class F
Special code3)
XXX: Customer special requirement
Nil: Flux proofed
Nil: Class B
Nil: Standard
Notes: 1) We recommend flux proofed types for a clean environment (free from contaminations like H2S, SO2, NO2, dust, etc.).
We suggest to choose plastic sealed types and validate it in real application for an unclean environment (with contaminations like H2S,
SO2, NO2, dust, etc.).
2) Contact is recommended for suitable condition and specifications if water cleaning or surface process is involved in assembling relays
on PCB.
3) The customer special requirement express as special code after evaluating by Hongfa. e.g.(335) stands for product in accordance to
IEC 60335-1 (GWT).
4) Two packing methods available: plastic tray package, tube package,Standard tube packing length is 616mm. Any special requirement
needed, please contact us for more details.
5) For products that should meet the explosion-proof requirements of "IEC 60079 series",please note [Ex] after the specification while placing
orders.Not all products have explosion-proof certification,so please contact us if necessary, in order to select the suitable products.
OUTLINE DIMENSIONS, WIRING DIAGRAM AND PC BOARD LAYOUT
Unit: mm
Outline Dimensions
12.7
2x□0.5
0.5x0.8(4处)
PCB Layout
Wiring Diagram
(Bottom view)
(Bottom view)
2.6
6x 1.3
0.3
5.04
①
⑥ ⑤
②
③ ④
20.16
Remark: 1) In case of no tolerance shown in outline dimension: outline dimension ≤1mm, tolerance should be ±0.2mm; outline dimension >1mm
and ≤5mm, tolerance should be ±0.3mm; outline dimension >5mm, tolerance should be ±0.4mm.
2) The tolerance without indicating for PCB layout is always ±0.1mm.
3) The width of the gridding is 2.52mm.
Disclaimer
The specification is for reference only. See to "Terminology and Guidelines" for more information. Specifications subject to change without notice.
We could not evaluate all the performance and all the parameters for every possible application. Thus the user should be in a right position to
choose the suitable product for their own application. If there is any query, please contact Hongfa for the technical service. However, it is the
user’s responsibility to determine which product should be used only.
© Xiamen Hongfa Electroacoustic Co., Ltd. All rights of Hongfa are reserved.
214
12.7
0.3
HF115F-S/12-HSF(257) 价格&库存
很抱歉,暂时无法提供与“HF115F-S/12-HSF(257)”相匹配的价格&库存,您可以联系我们找货
免费人工找货