HF115F-T/024-1Z3A(257) 数据手册
HF115 F -T/ T H
MINIATURE HIGH POWER RELAY
Features
●
●
●
●
●
●
●
●
●
File No.: E134517
V
D E
File No.:116934
File No.:CQC17002168381
High Temperature: 105
Low height 15.7 mm
5kV dielectric strength (between coil and contacts)
Creepage distance: 10mm
Meeting VDE 0700, 0631 reinforce insulation
Product in accordance to IEC 60335-1 available
UL insulation system: Class F
Sockets available
Plastic sealed and flux proofed types available
RoHS compliant
COIL
CONTACT DATA
Contact arrangement
1A, 1C
Contact resistance 1)
100m max.(at 1A 6VDC)
Contact material
HF115F-TH: Approx. 250mW;
HF115F-T: Approx. 400mW
Coil power
See ordering info.
HF115F-TH: 10A 250VAC
HF115F-T: 16A 250VAC
Contact rating (Res. load)
Max. switching voltage
440VAC / 300VDC
HF115F-TH:10A
HF115F-T:16A
HF115F-TH: 2500VA
HF115F-T: 4000VA
Max. switching current
Max. switching power
4
HF115F-T 1H3B type: 5 x 10 OPS
(16A 250VAC, Resistive load,
at 105℃, 5s on 5s off)
HF115F-TH 1H3B type: 5 x 104OPS
(10A 250VAC, Resistive load,
at 105℃, 5s on 5s off)
Electrical endurance
Notes: 1) The data shown above are initial values.
Insulation resistance
1000M (at 500VDC)
Dielectric Between coil & contacts
strength Between open contacts
Surge voltage (between coil & contacts)
5000VAC 1min
1000VAC 1min
10kV (1.2 / 50µs)
Pick-up Drop-out
Voltage Voltage
VDC
VDC
max. 1)
min.1)
Max.
Voltage
VDC 2)
Coil
Resistance
62 x (1 10%)
5
3.50
0.5
6.5
6
4.20
0.6
7.8
90 x (1 10%)
202 x (1 10%)
9
6.30
0.9
11.7
12
8.40
1.2
15.6
360 x (1 10%)
18
12.6
1.8
23.4
810 x (1 10%)
24
16.8
2.4
31.2
1440 x (1 10%)
3)
33.6
4.8
62.4
5760 x (1 15%)
60 3)
42.0
6.0
78
7500 x (1 15%)
48
CHARACTERISTICS
at 23
Standard type (HF115F-T)
Nominal
Voltage
VDC
1 x 107OPS
Mechanical endurance
COIL DATA
Sensitive type (HF115F-TH)
Pick-up Drop-out
Nominal
Voltage Voltage
Voltage
VDC
VDC
VDC
max.1)
min.1)
Max.
Voltage
VDC 2)
Coil
Resistance
Operate time (at rated. volt.)
15ms max.
5
3.75
Release time (at rated. volt.)
8ms max.
6
4.50
0.6
7.8
144 x (1 10%)
55K max.
9
6.75
0.9
11.7
324 x (1 10%)
98m/s2
12
9.00
1.2
15.6
576 x (1 10%)
18
13.50
1.8
23.4
1296 x (1 10%)
Temperature rise (at rated. volt.)
Shock resistance *
Functional
Destructive
Vibration resistance *
980m/s
2
10Hz to 150Hz 10g/5g
Humidity
5% to 85% RH
Ambient temperature
-40
to 105
Termination
PCB
Unit weight
Approx. 13.5g
Construction
Plastic sealed,
Flux proofed
24
0.5
6.5
100 x (1 10%)
18.00
2.4
31.2
2304 x (1 10%)
48
3)
36.00
4.8
62.4
9216 x (1 15%)
60
3)
45.00
6.0
78
12857 x (1 15%)
Notes: 1) The data shown above are initial values.
2) Maximum voltage refers to the maximum voltage which relay
coil could endure in a short period of time.
3) For products with rated voltage ≥ 48V, measures should be
taken to prevent coil overvoltage in order to protect coil in test
and application (eg. Connect diodes in parallel).
Notes: 1) The data shown above are initial values.
2) * Index is not that of relay length direction.
HONGFA RELAY
ISO9001, ISO/TS16949 , ISO14001, OHSAS18001, IECQ QC 080000 CERTIFIED
220
2020 Rev. 1.00
SAFETY APPROVAL RATINGS
HF115F-T-1H(S)3A
18.4A 250VAC at 105°C
10A 250VAC at 105°C
HF115F-TH -1H(S)3
VDE
6A 400VAC at 105°C
HF115F-T-1H(S)3B
16A 250VAC at 105°C
HF115F-TH -1H(S)3B
10A 250VAC at 105°C
NO: 16A 250VAC at 105°C
NC: 5A 250VAC at 105°C
HF115F-T-1Z(S)3B
UL/CUL
HF115F-TH -1H(S)3B
10A 277VAC
HF115F-TH -1H(S)3A
10A 277VAC
HF115F-T-1H(S)3B
16A 277VAC
HF115F-T-1H(S)3A
16A 250VAC
Notes: 1) All values unspecified are at room temperature.
2) Only typical loads are listed above. Other load specifications can be available upon request.
ORDERING INFORMATION
HF 115 F - T / T H
Type
HF115F-T: Standard
HF115F-TH: High Sensitive
Coil voltage
5, 6, 9, 12, 18, 24, 48, 60VDC
Contact arrangement
Construction
1)2)
1H: 1 Form A
0 12 -1H S
3
A
(XXX)
1Z: 1 Form C
S: Plastic sealed
Nil: Flux proofed
Version
3: 5.0mm
Contact material
A: AgSnO2
Special code3)
XXX: Customer special requirement
B: AgNi
Nil: AgCdO
Nil: Standard
Notes: 1) We recommend flux proofed types for a clean environment (free from contaminations like H2S, SO2, NO2, dust, etc.).
We suggest to choose plastic sealed types and validate it in real application for an unclean environment (with contaminations
like H2S, SO2, NO2, dust, etc.).
2) Contact is recommended for suitable condition and specifications if water cleaning or surface process is involved in assembling relays
on PCB.
3) The customer special requirement express as special code after evaluating by Hongfa. e.g.(335) stands for product in accordance to
IEC 60335-1 (GWT).
4) Two packing methods available: plastic tray package, tube package,Standard tube packing length is 616mm. Any special requirement
needed, please contact us for more details.
5) For products that should meet the explosion-proof requirements of "IEC 60079 series",please note [Ex] after the specification while placing
orders.Not all products have explosion-proof certification,so please contact us if necessary, in order to select the suitable products.
OUTLINE DIMENSIONS, WIRING DIAGRAM AND PC BOARD LAYOUT
Unit: mm
Outline Dimensions
12.7
0.5x0.5
0.3
6x0.5x0.8
221
OUTLINE DIMENSIONS, WIRING DIAGRAM AND PC BOARD LAYOUT
Unit: mm
PCB Layout
Wiring Diagram
(Bottom view)
(Bottom view)
5.04
2.6
1 Form A
5.04
8x 1.3
1 Form C
20.16
Remark: 1) In case of no tolerance shown in outline dimension: outline dimension ≤1mm, tolerance should be ±0.2mm; outline dimension >1mm
and ≤5mm, tolerance should be ±0.3mm; outline dimension >5mm, tolerance should be ±0.4mm.
2) The tolerance without indicating for PCB layout is always ±0.1mm.
3) The width of the gridding is 2.52mm.
CHARACTERISTIC CURVES
COIL OPERATING RANGE (DC) *
ENDURANCE CURVE
1000
3.6
3.4
3.0
100
2.6
0A
10 A
2.2
A
B
1.8
10
16 A
1.4
Recommended
voltage
1.0
1
0.6
0
2
4
6
8
10
12
14
16
Contact Current (A)
Notes:
1.Curve A: HF115F-T 1H3B type
Curve B: HF115F-TH 1H3B type
2.Test conditions:
NO, Resistive load, 250VAC, Flux proofed,
Room temp., 1s on 9s off
0
20
40
60
80
100
120
Ambient Temperature ( )
Notes: * The use of a relay with an energising voltage
other than the rated coil voltage may lead to
reduced electrical life.
An energising voltage over the abver range
may damage the insulation of relay coil.
Disclaimer
The specification is for reference only. See to "Terminology and Guidelines" for more information. Specifications subject to change without notice.
We could not evaluate all the performance and all the parameters for every possible application. Thus the user should be in a right position to
choose the suitable product for their own application. If there is any query, please contact Hongfa for the technical service. However, it is the user’s
responsibility to determine which product should be used only.
© Xiamen Hongfa Electroacoustic Co., Ltd. All rights of Hongfa are reserved.
222