HF152F-T/012-1ZSTQ(257) 数据手册
HF1 52 F
SUBMINIATURE HIGH POWER RELAY
Features
File No.: E134517
●
●
●
●
●
●
●
●
V
D E
File No.: 40017837
20A switching capability
TV-8 125VAC
Surge voltage up to 6kV (between coil and contacts)
Thermal class F: standard type (at 85 )
Ambient temperature meets 105
Product in accordance to IEC 60335-1 available
1 Form C and 1 Form A configurations available
Plastic sealed and dust protected types available
File No.: CQC16002155734
RoHS compliant
CONTACT DATA
CHARACTERISTICS
Contact arrangement
1A
Contact resistance1)
1C
100m max.(at 1A 24VDC)
Contact material
AgSnO2, AgNi
20A 125VAC
17A 277VAC
7A 400VAC
Contact rating
(Res. load)
Max. switching voltage
400VAC
Max. switching current
20A
Max. switching power
4700VA
16A 250VAC
10ms max.
400VAC (NO)
5ms max.
Functional
Shock resistance
Notes: 1) The data shown above are initial values.
2) For plastic sealed type, the venting-hole should be opened in
electrical endurance test.
at 23
Nominal
Voltage
VDC
Pick-up
Voltage
VDC
max.1)
Drop-out
Voltage
VDC
min.1)
3
2.25
0.3
3.9
25 x (1 10%)
5
3.75
0.5
6.5
70 x (1 10%)
6
4.50
0.6
7.8
100 x (1 10%)
9
6.75
0.9
11.7
225 x (1 10%)
Coil
Resistance
12
9.00
1.2
15.6
400 x (1 10%)
18
13.5
1.8
23.4
900 x (1 10%)
24
18.0
2.4
31.2
1600 x (1 10%)
48
36.0
4.8
62.4
6400 x (1 10%)
Notes: 1) The data shown above are initial values.
2) *Maximum voltage refers to the maximum voltage which relay
coil could endure in a short period of time.
Vibration resistance
10Hz to 55Hz 1.5mm DA
Humidity
5% to 85% RH
HF152F: -40 to 85
HF152F-T: -40 to 105
Ambient temperature
Termination
PCB
Unit weight
Approx.14g
Plastic sealed,
Dust protected
Construction
Notes: 1) The data shown above are initial values.
2) Please find coil temperature curve in the characteristic curves below.
3) UL insulation system: Class F
COIL
Approx. 360mW
Coil power
SAFETY APPROVAL RATINGS
AgNi
UL/CUL
AgSnO2
VDE
20A 125VAC
NO/NC: 17A/15A 277VAC
20A 125VAC
TV-8 125VAC
NO: 16A 250VAC at 105
NO: 1HP 250VAC
1 Form A
16A 250VAC
7A 400VAC
1 Form C
NO: 16A 250VAC
NC: 7A 250VAC
AgSnO2
Notes: 1) All values unspecified are at room temperature.
2) Only typical loads are listed above. Other load specifications
can be available upon request.
HONGFA RELAY
ISO9001, ISO/TS16949 , ISO14001, OHSAS18001, IECQ QC 080000 CERTIFIED
192
98m/s2
980m/s2
Destructive
4000VA
o
Max.
Voltage
VDC* 2)
6kV (1.2 / 50µs)
Release time (at rated. volt.)
16A
COIL DATA
Surge voltage(between coil & contacts)
1000VAC 1min
Operate time (at rated. volt.)
1 x 10 OPS
1 x 105OPS (16A 250VAC,
Resistive load, at 85 C, 1s on 9s off)
5 x 104OPS (NO, 16A 250VAC,
Resistive load,
Room temp., 1s on 9s off)
5 x 104OPS (NC, 10A 250VAC,
Resistive load,
Room temp., 1s on 9s off)
Electrical endurance
100M (at 500VDC)
2500VAC 1min
7A 400VAC (NO)
7
Mechanical endurance
Insulation resistance
Dielectric Between coil & contacts
strength Between open contacts
2020 Rev. 1.00
ORDERING INFORMATION
Type
S
P
HF 1 52F / 01 2 - 1Z
Q
T
(XXX)
HF152F: 85 , HF152F-T: 105
Coil voltage
3, 5, 6, 9, 12, 18, 24, 48VDC
Contact arrangement
1H: 1 Form A
1Z: 1 Form C
Pin version
P: Double pins
Nil: Single pin
Construction
1)
S: Plastic sealed
Contact material
T: AgSnO2
Contact capacity
Nil: Dust protected
Nil: AgNi
Q: High capacity type 16A 250VAC, at 105
Special code4)
(Only for HF152F-T) Nil: Standard type
XXX: Customer special requirement
Nil: Standard
Notes: 1) Under the ambience with dangerous gas like H2S, SO2 or NO2, plastic sealed type is recommended; Please test the relay in real applications.
If the ambience allows, dust protected type is preferentially recommended.
2) Contact is recommended for suitable condition and specifications if water cleaning or surface process is involved in assembling relays
on PCB.
3) If plastic sealed type is selected for cleaning purpose, the vent-hole cover should be excised after cleaning.
4) The customer special requirement express as special code after evaluating by Hongfa.
5) HF152F-T is only available for AgSnO2 contact.
6) Two packing methods available: paper box package, tube package,Standard tube packing length is 455mm. Any special requirement
needed, please contact us for more details.
7) For products that should meet the explosion-proof requirements of "IEC 60079 series",please note [Ex] after the specification while placing
orders.Not all products have explosion-proof certification,so please contact us if necessary, in order to select the suitable products.
OUTLINE DIMENSIONS, WIRING DIAGRAM AND PC BOARD LAYOUT
Single pin version
Unit: mm
Outline Dimensions
16
21
Vent-hole cover
+0.3
(Top view)
3.5 -0.5
Wiring Diagram
(Bottom view)
1 Form A
1 Form C
PCB Layout
(Bottom view)
12.2
12.2
4x Ø1.3
1 Form A
5xØ 1.3
1 Form C
2
4.8
2
4.8
193
OUTLINE DIMENSIONS, WIRING DIAGRAM AND PC BOARD LAYOUT
Double pin version
Unit: mm
Outline Dimensions
16
21
Vent-hole cover
+0.3
3.5 -0.5
1x0.4
(Top view)
1.8x0.4
0.5x0.5
Wiring Diagram
(Bottom view)
1 Form A
1 Form C
PCB Layout
(Bottom view)
4
4
4xØ 1.3
2x0.8
2x0.8
1 Form A
2
6xØ 1.3
1 Form C
12.2
2.8
2
12.2
2.8
Remark: 1) In case of no tolerance shown in outline dimension: outline dimension ≤1mm, tolerance should be ±0.2mm; outline dimension >1mm
and ≤5mm, tolerance should be ±0.3mm; outline dimension >5mm, tolerance should be ±0.4mm.
2) The tolerance without indicating for PCB layout is always ±0.1mm.
CHARACTERISTIC CURVES
ENDURANCE CURVE
MAX. SWITCHING POWER
40
1A, 1C
COIL TEMPERATURE RISE
60
100
1A
1C (NO)
20
17
16
10
50
B
A
7
1A, 1C (NO)
D
10
1
16A at 105
40
30
5
20
C
10
0
10
100 125
300 400
1000
Contact Voltage (V)
4
6
8
10
12
14
16
18
20
0
80
90
100
110
120
Percentage Of Nominal Coil Voltage
Contact Current (A)
Notes:
1. Curve A:1H type, Curve B:1H type, Curve C:1Z type, Curve D:1Z type
2. Test conditions:
Curve A: 20A 125VAC, Resistive load, Room temp., 1s on 9s off
Curve B: 16A 250VAC, Resistive load, at 85 , 1s on 9s off
Curve C: NO, 20A 125VAC, Resistive load, Room temp., 1s on 9s off
Curve D: NO, 16A 250VAC, Resistive load, at 85 , 1s on 9s off
Disclaimer
The specification is for reference only. See to "Terminology and Guidelines" for more information. Specifications subject to change without notice.
We could not evaluate all the performance and all the parameters for every possible application. Thus the user should be in a right position to
choose the suitable product for their own application. If there is any query, please contact Hongfa for the technical service. However, it is the
user’s responsibility to determine which product should be used only.
© Xiamen Hongfa Electroacoustic Co., Ltd. All rights of Hongfa are reserved.