H F1 6 1F
MINIATURE HIGH POWER RELAY
Features
File No.: E134517
● 4.5kV dielectric strength
(between coil and contacts)
V
D E
● Heavy load up to 6250VA
File No.: 40031410
● Ideal for motor switching
● PCB layouts available
● UL insulation system: Class F
File No.:CQC10002050943
CQC18002203499
RoHS compliant
COIL
CONTACT DATA
Contact arrangement
1A
Contact resistance1)
100m max.(at 1A 6VDC)
Contact material
AgSnO2, AgCdO
Resistive: 20A 250VAC
Motor: 2HP 250VAC
Contact rating
Max. switching voltage
250VAC
Max. switching current
Resistive: 25A
Max. switching power
6250VA
2 x 106OPS
Mechanical endurance
HT type: 1 x 105OPS (20A 250VAC,
Resistive load, Room temp.,
1.5s on 1.5s off)
Electrical endurance
Notes: 1)The data shown above are initial values.
Approx. 900mW
Coil power
COIL DATA
at 23
Pick-up
Voltage
VDC
max.1)
Drop-out
Voltage
VDC
min.1)
5
3.5
0.5
6.0
27.8 x (1 10%)
12
8.4
1.2
14.4
160 x (1 10%)
24
16.8
2.4
28.8
640 x (1 10%)
48
33.6
4.8
57.6
2560 x (1 10%)
Nominal
Voltage
VDC
Max.
Voltage
VDC * 2)
Coil
Resistance
Notes: 1)The data shown above are initial values.
2)*Maximum voltage refers to the maximum voltage which relay
coil could endure in a short period of time.
SAFETY APPROVAL RATINGS
CHARACTERISTICS
Insulation resistance
1000M (at 500VDC)
Between coil & contacts
4500VAC 1min
Between open contacts
1000VAC 1min
Surge voltage (between coil & contacts)
10kV (1.2 / 50µs)
Dielectric
strength
25A 250VAC at 85 C
20A 250VAC at 85 C
2HP 250VAC at 85 C
o
UL/CUL
o
o
Operate time (at rated. volt.)
20ms max.
Release time (at rated. volt.)
10ms max.
Temperature rise (at rated. volt.)
Shock resistance
60K max.
Functional
196m/s2
Destructive
980m/s2
Vibration resistance
25A 250VAC at 85 C
o
VDE
20A 250VAC at 85 C
o
Notes: 1) All values unspecified are at room temperature.
2) Only typical loads are listed above. Other load specifications
can be available upon request.
10Hz to 55Hz 1.5mm DA
Ambient temperature
Humidity
-40
to 85
5% to 85% RH
Termination
PCB
Unit weight
Approx. 21g
Construction
Flux proofed
Notes: The data shown above are initial values.
HONGFA RELAY
ISO9001, ISO/TS16949 , ISO14001, OHSAS18001, IECQ QC 080000 CERTIFIED
282
2020 Rev. 1.00
ORDERING INFORMATION
HF 1 61 F /
12
-H
T
(XXX)
Type
Coil voltage
5, 12, 24, 48VDC
Contact arrangement
H: 1 Form A
Contact matcrial
T: AgSnO2
Special code3)
XXX: Customer special requirement
Nil: AgCdO
Nil: Standard
Notes: 1) Water cleaning or surface process is not suggested after the flux-proofed relays are assembled on PCB.
2) Flux-proofed relays can not be used in the environment with pollutants like H2S, SO2, NO2, dust, etc.
3) The customer special requirement express as special code after evaluating by Hongfa. e.g. (414) stands for product with coil terminal of
1.4X0.4.
4) Two packing methods available: plastic tray package, tube package,Standard tube packing length is 592mm. Any special requirement
needed, please contact us for more details.
5) For products that should meet the explosion-proof requirements of "IEC 60079 series",please note [Ex] after the specification while placing
orders.Not all products have explosion-proof certification,so please contact us if necessary, in order to select the suitable products.
OUTLINE DIMENSIONS, WIRING DIAGRAM AND PC BOARD LAYOUT
Unit: mm
Outline Dimensions
Standard type
30.4 ±0.3
15.9 ±0.3
+0.2
2- (0.8 ±0.3 )x(1.5 ±0.3 )
2xØ 0.7- 0 . 0 5
(414) special code version
30.4 ±0.3
+0.2
+0.2
15.9 ±0.3
2-(0.8 ±0.3 )x(1.5 ±0.3 )
2-1.4- 0 . 0 5x0.4- 0 . 0 5
283
OUTLINE DIMENSIONS, WIRING DIAGRAM AND PC BOARD LAYOUT
Unit: mm
PCB Layout (Bottom view)
Standard type
(414) special code version
27.6 ±0.1
12 ±0.05
22 ±0.1
Wiring Diagram
Remark: 1) In case of no tolerance shown in outline dimension: outline dimension ≤1mm, tolerance should be ±0.2mm; outline dimension >1mm
and ≤5mm, tolerance should be ±0.3mm; outline dimension >5mm, tolerance should be ±0.4mm.
2) The tolerance without indicating for PCB layout is always ±0.1mm.
CHARACTERISTIC CURVES
ENDURANCE CURVE
MAXIMUM SWITCHING POWER
500
100
50
AC Resistive Load
250VAC
Inductive Load
(cosØ=0.4)
10
100
5
50
250VAC
Resistive Load
1
250VAC
Inductive Load
(cosØ=0.4)
0.5
10
0.1
1
10
20 30
100
200 300
1000
Contact Voltage (V)
0
2
4
6
8
10 12
14 16 18 20 22
Contact Current (A)
Test conditions:
Room temp., 1s on 9s off.
Disclaimer
The specification is for reference only. See to "Terminology and Guidelines" for more information. Specifications subject to change without notice.
We could not evaluate all the performance and all the parameters for every possible application. Thus the user should be in a right position to
choose the suitable product for their own application. If there is any query, please contact Hongfa for the technical service. However, it is the user’s
responsibility to determine which product should be used only.
© Xiamen Hongfa Electroacoustic Co., Ltd. All rights of Hongfa are reserved.
284
很抱歉,暂时无法提供与“HF161F/24-HT(257)”相匹配的价格&库存,您可以联系我们找货