HF2100-1A-12DEF(257) 数据手册
HF2 10 0
MINIATURE HIGH POWER RELAY
Features
File No.:E134517
● 30A switching capability
● PCB coil terminals, ideal for heavy duty load
● 2.5kV dielectric strength (between coil and contacts)
● Plastic sealed and Dust protected types available
File No.:R50153835
● UL insulation system: Class F available
File No.:CQC10002049166
RoHS compliant
COIL
CONTACT DATA
Contact
arrangement
Contact
resistance1)
1A
1B
1C (NO)
Approx. 900mW
Coil power
50m max.(at 1A 24VDC)
Contact material
AgSnO2, AgCdO
Contact rating
(Res. load)
30A 240VAC 15A 240VAC
20A 30VDC 10A 30VDC
Max. switching
power
11080VA
1200W
Max. switching
voltage
Max. switching
current
1C (NC)
4155VA
450W
20A 240VAC 10A240VAC
20A 30VDC 10A 30VDC
5540VA
600W
2770VA
300W
277VAC / 30VDC
40A2)
Max.continuous
current
15A
20A
10A
When PCB terminals carry current≤30A
When PCB terminals do not carry current
(only QC terminals carry current)≤25A
Mechanical
endurance
1 x 107OPS
Electrical
endurance
1A type(Non-plastic sealed): 1 x 105OPS
(30A 240VAC, Resistive load,
AgCdO, Room temp., 1s on 9s off)
Notes:1) The data shown above are initial values.
2) Long time current-carrying under 40A condition is prohibited.
CHARACTERISTICS
Insulation resistance
Dielectric Between coil & contacts
strength Between open contacts
Operate time (at rated. volt.)
Release time (at rated. volt.)
Ambient temperature
Functional
Shock
resistance Destructive
Vibration resistance
Humidity
Termination
Unit weight
Construction
1000M (at 500VDC)
2500VAC 1min
1500VAC 1min
15ms max.
10ms max.
-55 C to 85 C
98m/s2
980m/s2
o
COIL DATA
at 23
Nominal
Voltage
VDC
Pick-up
Voltage
VDC
max.1)
Drop-out
Voltage
VDC
min.1)
Max.
Voltage
VDC*2)
5
3.75
0.5
6.5
27 x (1 10%)
6
4.50
0.6
7.8
40 x (1 10%)
9
6.75
0.9
11.7
97 x (1 10%)
12
9.00
1.2
15.6
155 x (1 10%)
15
11.25
1.5
19.5
256 x (1 10%)
18
13.50
1.8
23.4
380 x (1 10%)
24
18.00
2.4
31.2
660 x (1 10%)
48
36.00
4.8
62.4
2560 x (1 10%)
70
52.50
7.0
91.0
5500 x (1 10%)
110
82.50
11.0
143.0
13450 x (1 10%)
Coil
Resistance
Notes:1)The data shown above are initial values.
2)*Maximum voltage refers to the maximum voltage which relay
coil could endure in a short period of time.
o
10Hz to 55Hz 1.5mm DA
5% to 85% RH
PCB & QC
Approx. 35g
Plastic sealed,
Dust protected
Notes: 1) For plastic sealed type, the venting-hole should be opened in
test.
2) The data shown above are initial values.
3) Please find coil temperature curve in the characteristic curves below.
4) UL insulation system: Class F, Class B.
5) It is recommended that the terminal of the process QC cannot
pass through more than 25A current for a long period of time .
HONGFA RELAY
ISO9001, ISO/TS16949 , ISO14001, OHSAS18001, IECQ QC 080000 CERTIFIED
2019 Rev. 1.00
327
SAFETY APPROVAL RATINGS
UL/CUL
Contact
material
Load type
General
purpose
Resistive
Ballast
Pilot duty
AgCdO
Motor load
Definite
1 Form A
30A
1 Form B
15A
277VAC
30A
30A
125/240VAC
30A
15A
10A
30VDC
20A
277VAC
20A
240VAC
15A
250VAC
40A
125/240/277VAC
6A
3A
125VAC
800VA
290VA
125VAC
690VA
125VAC
800VA
240VAC
1152VA
277VAC
764VA
30A
30A
20A
10A
6A
3A
800VA
290VA
690VA
800VA
768VA
1152VA
768VA
764VA
125VAC
1HP
1/4HP
1HP
1/4HP
240VAC
2HP
1HP
2HP
1HP
125VAC
1HP
125/277VAC
3/4HP
3/4HP
120VAC 82.8LRA, 13.8FLA
82.8LRA, 13.8FLA
1HP
125VAC
96LRA, 30FLA
33LRA, 10FLA
125VAC
60LRA, 20FLA
30LRA, 12FLA
(LRA-
125VAC
82.8LRA, 27FLA
60LRA, 20FLA 33LRA, 10FLA
60LRA, 20FLA 30LRA, 12FLA
82.8LRA, 27FLA
loaded rotor)
240VAC
80LRA, 30FLA
(FLA-full load)
240VAC
41.4LRA, 6.9FLA
41.4LRA, 6.9FLA
277VAC
60LRA, 20FLA
60LRA, 20FLA
125VAC
15A
15A
240VAC
5A
General purpose
33LRA, 10FLA
3A
240VAC
3A
125/240VAC
30A
Resistive
250VAC
40A
General purpose
240VAC
60LRA, 20FLA 33LRA, 10FLA
5A
120VAC
15A
Notes: 1) All values unspecified are at room temperature.
2) Only typical loads are listed above. Other load specifications can be available upon request.
328
1 Form C (NO) 1 Form C (NC)
30A
15A
40A
purpose
Tungsten
AgSnO2
Volts
125/240VAC
3A
ORDERING INFORMATION
HF2100
-1A
-12D E T F
(XXX)
Type
Contact arrangement 1A: 1 Form A 1B: 1 Form B 1C: 1 Form C
Coil voltage
Construction
5, 6, 9, 12, 15, 18, 24, 48, 70, 110VDC
1)
Contact material
Insulation standard
Special
E: Plastic sealed
Nil: Dust protected
T: AgSnO2
Nil: AgCdO
F: Class F
code3)
Nil: Class B
XXX: Customer special requirement
Nil: Standard
Notes: 1) We recommend dust protected types for a clean environment (free from contaminations like H2S, SO2, NO2, dust, etc.).
We suggest to choose plastic sealed types and validate it in real application for an unclean environment (with contaminations
like H2S, SO2, NO2, dust, etc.).
2) Contact is recommended for suitable condition and specifications if water cleaning or surface process is involved in assembling relays
on PCB.
3) The customer special requirement express as special code after evaluating by Hongfa.
OUTLINE DIMENSIONS, WIRING DIAGRAM AND PC BOARD LAYOUT
Unit: mm
1 Form A
PCB Layout
Wiring Diagram
Outline Dimensions
(Bottom view)
27.5
3.6
28
2x 2.1
3.8
(Bottom view)
(Top view)
2x 1.1
14
17.8
1 Form B
27.5
3.6
2x 2.1
28
3.8
(Bottom view)
(Top view)
2x 1.1
14
17.8
329
OUTLINE DIMENSIONS, WIRING DIAGRAM AND PC BOARD LAYOUT
Unit: mm
1 Form C
27.5
3x 2.1
28
3.6
3.8
2x 1.1
(Bottom view)
(Top view)
14
17.8
Remark: 1) In case of no tolerance shown in outline dimension: outline dimension ≤1mm, tolerance should be ±0.2mm; outline dimension >1mm
and ≤5mm, tolerance should be ±0.3mm; outline dimension >5mm, tolerance should be ±0.4mm.
2) The tolerance without indicating for PCB layout is always ±0.1mm.
CHARACTERISTIC CURVES
MAXIMUM SWITCHING POWER
100
40
30
20
15
ENDURANCE CURVE
COIL TEMPERATURE RISE
110
100
DC Coil
1A
1C (NO)
100
30
1A
90
1B
10
1C (NO)
1C (NC)
80
1C (NC)
10
1B
70
30A
60
1
AC Resistive
Load
15A
40
DC Resistive
1 Load
10
25A
20A
50
0A
100
200
1000
Contact Voltage (V)
0
10
20
30
40
Contact Current (A)
0
80
90
100
110
120
130
140
150
160
Percentage Of Nominal Coil Voltage
Test conditions:
Resistive load, AgCdO, Dust protected,
Room temp., 1s on 9s off.
Disclaimer
The specification is for reference only. See to "Terminology and Guidelines" for more information. Specifications subject to change without notice.
We could not evaluate all the performance and all the parameters for every possible application. Thus the user should be in a right position to
choose the suitable product for their own application. If there is any query, please contact Hongfa for the technical service. However, it is the user’s
responsibility to determine which product should be used only.
© Xiamen Hongfa Electroacoustic Co., Ltd. All rights of Hongfa are reserved.
330