H F2 1 F F
SUBMINIATURE HIGH POWER RELAY
Features
● 15A switching capability
● 1 Form A, 1 Form B and 1 Form C configurations
● Standard PCB layout
● Plastic sealed and dust protected types available
File No.:E133481
RoHS compliant
CONTACT DATA
Contact arrangement
COIL
1A, 1B
Contact resistance1)
1C
100m max.(at 1A 6VDC)
Contact material
Contact rating
5VDC to 24VDC: Approx. 360mW;
48VDC: Approx. 530mW
Coil power
AgSnO2
15A 120VAC
10A 120VAC/24VDC
COIL DATA
at 23
Nominal
Voltage
VDC
Pick-up
Voltage
VDC
max.1)
Drop-out
Voltage
VDC
min.1)
Max.
Voltage
VDC *2)
5
3.75
0.5
6.5
70 x (1 10%)
6
4.50
0.6
7.8
100 x (1 10%)
9
6.75
0.9
11.7
225 x (1 10%)
12
9.00
1.2
15.6
400 x (1 10%)
Notes: 1) The data shown above are initial values.
18
13.5
1.8
23.4
900 x (1 10%)
CHARACTERISTICS
24
18.0
2.4
31.2
1600 x (1 15%)
48
36.0
4.8
62.4
4500 x (1 15%)
Max. switching voltage
Max. switching current
120VAC / 30VDC
15A
10A
Max. switching power
1800VA / 240W
1 x 107 OPS
Mechanical endurance
Electrical endurance
1H type: 1 x 105OPS
(15A 120VAC, Resistive load,
Room temp., 1s on 9s off)
Insulation resistance
Dielectric Between coil & contacts
strength
Between open contacts
100M (at 500VDC)
1500VAC 1min
750VAC 1min
Operate time (at rated. volt.)
10ms max.
Release time (at rated. volt.)
5ms max.
Shock
resistance
Functional
98m/s
Destructive
980m/s2
Vibration resistance
Notes: 1) The data shown above are initial values.
2)*Maximum voltage refers to the maximum voltage which relay
coil could endure in a short period of time.
SAFETY APPROVAL RATINGS
2
10A 120VAC
1 Form C
10Hz to 55Hz 1.5mm DA
5% to 85% RH
Humidity
Coil
Resistance
15A 120VAC
1 Form A
TV-5 120VAC
UL/CUL
o
Operation temperature range
-40
15A 120VAC 1800VA at 25 C, Ballast
to 70
o
Termination
PCB
Unit weight
Approx. 13g
Construction
Plastic sealed,
Dust protected
Notes: 1) The data shown above are initial values.
2) Please find coil temperature curve in the characteristic curves below.
3) UL insulation system: Class F, Class B.
1 Form B
6.5A 277VAC 1800VA at 25 C, Ballast
o
8.3A 120VAC 1000VA at 90 C, Ballast
o
3.6A 277VAC 1000VA at 90 C, Ballast
Notes: 1) All values unspecified are at room temperature.
2) Only typical loads are listed above. Other load specifications
can be available upon request.
HONGFA RELAY
ISO9001, ISO/TS16949 , ISO14001, OHSAS18001, IECQ QC 080000 CERTIFIED
2019 Rev. 1.10
189
ORDERING INFORMATION
H F2 1F F /
0 12 - 1H
S
T
F (XXX)
Type
Coil voltage
5, 6, 9, 12, 18, 24, 48VDC
Contact arrangement
1H: 1 Form A
1D: 1 Form B
1Z: 1 Form C
Construction 1)
S: Plastic sealed
Contact material
T: AgSnO2
Insulation standard
F: Class F
Special code3)
XXX: Customer special requirement
Nil: Dust protected
Nil: Class B
Nil: Standard
Notes: 1) Under the ambience with dangerous gas like H2S, SO2 or NO2, plastic sealed type is recommended; Please test the relay in real applications.
If the ambience allows, dust protected type is preferentially recommended.
2) Contact is recommended for suitable condition and specifications if water cleaning or surface process is involved in assembling relays on
PCB.
3) The customer special requirement express as special code after evaluating by Hongfa.
OUTLINE DIMENSIONS, WIRING DIAGRAM AND PC BOARD LAYOUT
Outline Dimensions
20.2
Unit: mm
Wiring Diagram
PCB Layout
(Bottom view)
(Bottom view)
4x 1.3
16.5
1 Form A
2
12.2
4
0.5
1
1
1
0.4
0.5
16.5
20.2
1 Form B
4x 1.3
1
0.4
0.5
190
2
1
0.5
1
12.2
4
OUTLINE DIMENSIONS, WIRING DIAGRAM AND PC BOARD LAYOUT
Outline Dimensions
20.2
Unit: mm
Wiring Diagram
PCB Layout
(Bottom view)
(Bottom view)
16.5
5x 1.3
1 Form C
2
0.5
1
1
0.4
12.2
4
1
0.5
Remark:1) * The additional tin top is max. 1mm.
2) In case of no tolerance shown in outline dimension: outline dimension ≤1mm, tolerance should be ±0.2mm; outline dimension >1mm
and ≤5mm, tolerance should be ±0.3mm; outline dimension >5mm, tolerance should be ±0.4mm.
3) The tolerance without indicating for PCB layout is always ±0.1mm.
CHARACTERISTIC CURVES
MAXIMUM SWITCHING POWER
ENDURANCE CURVE
COIL TEMPERATURE RISE
100
50
90
80
AC
Resistive load
20
70
NO
10
60
10
50
4
5
40
NC
3
2
30
DC
Resistive load
1
10
30
100
200 300
400
Contact Voltage (VAC)
0
5
10
15
0
80
Test conditions:
NO: Resistive load, Room temp.,
flux proofed, 15A 120VAC, 1s on 9s off
NC: Resistive load, Room temp.,
flux proofed, 10A 120VAC, 1s on 9s off
90
100
110
120
130
Coil Power (W)
Contact Current (A)
Testing conditions: 10A at 70
Mounting distance: 25mm
.
Disclaimer
The specification is for reference only. See to "Terminology and Guidelines" for more information. Specifications subject to change without notice.
We could not evaluate all the performance and all the parameters for every possible application. Thus the user should be in a right position to
choose the suitable product for their own application. If there is any query, please contact Hongfa for the technical service. However, it is the user’s
responsibility to determine which product should be used only.
© Xiamen Hongfa Electroacoustic Co., Ltd. All rights of Hongfa are reserved.
191