HF32FV-G/12-HSF(257) 数据手册
HF32FV-G/HF32FV-T SUBMINIATURE INTERMEDIATE POWER RELAY
Features
● 10A switching capability
● Dielectric strength 4kV (between coil and contacts)
● TV-5 products are available
File No.:E134517
V
D E
● Relow soldering version available
● Halogen-free products are available
● Product in accordance to IEC60335-1 available
File No.:40012204
● Meet reinforce insulation
● UL insulation system: Class F
File No.:CQC14002120720
RoHS compliant
COIL
CONTACT DATA
Contact arrangement
1A
Contact resistance1)
100m
max.(at 1A 6VDC)
2)
AgNi ,AgSnO2, AgCdO2)
Contact material
Contact rating
(Res. load)
Standard: Approx. 450mW;
Sensitive: Approx. 200mW
Coil power
Sensitive 3)
10A 250VAC
Standard
Max. switching voltager
277VAC
Max. switching current
10A
Max. switching power
2770VA
Mechanical endurance
1 x 107OPS
1 x 105OPS (10A 250VAC Resistive load,
at room temp., 1s on 9s off)
Standard
5 x 104OPS (10A 250VAC Resistive load,
at 85 , 1s on 9s off)
no suffix 590
5
1 x 10 OPS (8A 250VAC Resistive load,
Electrical
at room temp., 1s on 9s off)
endurance
5 x 104OPS (8A 250VAC Resistive load,
at 85 , 1s on 9s off)
3)
Sensitive 5 x 104OPS (10A 250VAC Resistive load,
at room temp., 1s on 9s off)
suffix 590
3 x 104OPS (10A 250VAC Resistive load,
at 85 , 1s on 9s off)
Notes:1) The data shown above are initial values.
2) Only applicable to HF32FV-G no suffix 590.
3) Only applicable to HF32FV-G.
COIL DATA
Standard Type
Pick-up
Nominal
Voltage
Voltage
VDC
VDC
max. 1)
at 23
Drop-out
Voltage
VDC
min. 1)
Max.
Voltage
VDC * 2)
Coil
Resistance
3
2.25
0.15
3.9
20 x (1 10%)
5
3.75
0.25
6.5
55 x (1 10%)
6
4.50
0.30
7.8
80 x (1 10%)
9
6.75
0.45
11.7
180 x (1 10%)
12
9.00
0.60
15.6
320 x (1 10%)
18
13.5
0.90
23.4
720 x (1 10%)
24
18.0
1.20
31.2
1280 x (1 10%)
48
36.0
2.40
62.4
5120 x (1 10%)
Max.
Voltage
VDC * 2)
Coil
Resistance
CHARACTERISTICS
Insulation resistance
1000M (at 500VDC)
Dielectric Between coil & contacts
strength Between open contacts
4000VAC 1min
Surge withstand voltage
6kV(1.2 / 50µs)
1000VAC 1min
8ms max.
Operate time (at rated. volt.)
Sensitive Type
Pick-up Drop-out
Nominal
Voltage Voltage
Voltage
VDC
VDC
VDC
max. 1)
min. 1)
3
2.25
0.15
4.5
45 x (1 10%)
3.75
0.25
7.5
125 x (1 10%)
5ms max.
5
Shock * 2)
294m/s2
6
4.50
0.30
9.0
180 x (1 10%)
resistance
980m/s
10Hz to 55Hz 1.5mm DA
9
6.75
0.45
13.5
400 x (1 10%)
12
9.00
0.60
18.0
720 x (1 10%)
18
13.5
0.90
27.0
1600 x (1 10%)
24
18.0
1.20
36.0
2800 x (1 10%)
48
36.0
2.40
72.0
11520 x (1 10%)
Release time (at rated. volt.)
Functional
Destructive
Vibration resistance * 2) Functional
2
Humidity
5% to 85% RH
Ambient oprating temperature
-40
Termination
to 105
PCB
Approx. 6g
Unit weight
Construction
Plastic sealed, Flux proofed
Notes: 1) The data shown above are initial values;
2) HF32FV-T only provides Flux proofed;
3) For working environment temperature > 85 ,please contact
with Hongfa.
Notes: 1) The data shown above are initial values.
2)* Maximum voltage refers to the maximum voltage which
relay coil could endure in a short period of time.
HONGFA RELAY
ISO9001, ISO/TS16949 , ISO14001, OHSAS18001, IECQ QC 080000 CERTIFIED
2020 Rev. 1.01
137
SAFETY APPROVAL RATINGS
10A 277VAC /250VAC General use 85
10A 277VAC/250VAC Resistive Load 40
10A 277VAC/250VAC Resistive Load 105
10A 277VAC/250VAC Resistive Load(Sensitive) 40
10A 277VAC/250VAC Resistive Load(Sensitive) 85
8A 277VAC/250VAC General use(Sensitive) 85
TV-5 120VAC (suffix 590) 40
3A 120VAC electronic ballast (Sensitive suffix 590) 85
10A 277VAC/250VAC General use 85
10A 277VAC/250VAC Resistive Load 105
10A 30VDC Resistive Load 85
10A 277VAC/250VAC Resistive Load 40
8A 277VAC/250VAC General use(Sensitive) 85
10A 277VAC/250VAC Resistive Load 40
8A 277VAC/250VAC Resistive Load(Sensitive) 40
AgSnO2
HF32FV-G
AgCdO
UL/CUL
AgNi
HF32FV-T
10A 277VAC/250VAC General use 105
10A 277VAC/250VAC Resistive Load 105
1/3HP 250VAC Motor Load 105
10A 277VAC/250VAC Resistive Load 85
10A 277VAC/250VAC Resistive Load(Sensitive) 85
8A 277VAC/250VAC Resistive Load(Sensitive) 85
AgSnO2
AgSnO2
HF32FV-G
AgCdO
10A 277VAC/250VAC Resistive Load 85
10A 277VAC/250VAC Resistive Load 85
8A 277VAC/250VAC Resistive Load(Sensitive) 85
10A 277VAC/250VAC Resistive Load 105
5A 250VAC COSΦ 0.6 105
10A 277VAC/250VAC Resistive Load 85
8A 277VAC/250VAC Resistive Load(Sensitive) 85
10A 277VAC/250VAC Resistive Load(Sensitive) 85
10A 277VAC/250VAC Resistive Load 105
10A 277VAC/250VAC Resistive Load(Sensitive) 105
10A 277VAC/250VAC Resistive Load 85
AgNi
VDE
HF32FV-T
AgSnO2
AgSnO2
HF32FV-G
AgCdO
CQC
10A 277VAC/250VAC Resistive Load 85
8A 277VAC/250VAC Resistive Load(Sensitive) 85
AgNi
10A 277VAC/250VAC Resistive Load 105
AgSnO2
HF32FV-T
Notes: 1) Opening the vent hole under contact material AgSnO2 testing.
2) Only typical loads are listed above. Other load specifications can be available upon request.
ORDERING INFORMATION
HF32FV-G/
Type
Coil voltage
12
-H
S
L
T
F
(XXX)
HF32FV-G
HF32FV-T
3, 5, 6, 9, 12, 18, 24, 48VDC
Contact arrangement H: 1 Form A
Construction 1) 2)
S: Plastic sealed3)
Coil power
L: Sensitive3)
Nil: Standard
Contact material
T: AgSnO2
3: AgNi4)
Insulation standard
Special code5)
Nil: Flux proofed
Nil: AgCdO4)
F: Class F
XXX: Customer special requirement
Nil: Standard
Notes: 1) We recommend flux proofed types for a clean environment (free from contaminations like H2S, SO2, NO2, dust, etc.).
2) Contact is recommended for suitable condition and specifications if water cleaning or surface process is involved in assembling relays on
PCB.
3) Only applicable to HF32FV-G.
4) Only applicable to HF32FV-G with no suffix 590.
5) The customer special requirement express as special code after evaluating by Hongfa. e.g. (335) stands for product in accordance to
IEC 60335-1 (GWT); suffix 590 for product in accordance to TV loading. For standard type is TV-5, for sentitive type is TV-3.
6) Two packing methods available: paper box package, tube package,Standard tube packing length is 553mm. Any special requirement
needed, please contact us for more details.
7) For products that should meet the explosion-proof requirements of "IEC 60079 series",please note [Ex] after the specification while placing
orders.Not all products have explosion-proof certification,so please contact us if necessary, in order to select the suitable products.
138
OUTLINE DIMENSIONS, WIRING DIAGRAM AND PC BOARD LAYOUT
Outline Dimensions
Unit: mm
Wiring Diagram
PCB Layout
(Bottom view)
(Bottom view)
4.1
10.2
18.4
12.7
4xØ1.3
(Bottom view)
(1)
2x□0.45
0.2
0.3
2.54
0.2
Remark:1) the pin size of HF32FV-G sensitive with suffix 590 is 0.4mm.
2) The pin dimension of the product outline drawing is the size before tinning (it will become larger after tinning), and the mounting hole
size is the recommended design size of the PCB board hole. The specific PCB board hole design size can be mapped and adjusted
according to the actual product.
3) In case of no tolerance shown in outline dimension: outline dimension ≤1mm, tolerance should be ±0.2mm; outline dimension >1mm
and ≤5mm, tolerance should be ±0.3mm; outline dimension >5mm, tolerance should be ±0.4mm.
4) The tolerance without indicating for PCB layout is always ±0.1mm.
5) The width of the gridding is 2.54mm.
CHARACTERISTIC CURVES
MAXIMUM SWITCHING POWER
ENDURANCE CURVE
COIL TEMPERATURE RISE
50
50
70
A
60
D
A
B
50
10
10
5
B
4
C
40
C
AC
Restitive
load
30
D
3
2
20
DC
Restitive
load
10
100
200 300
400
0
1
2
3
4
5
6
7
8
9
10
Contact Current(A)
Contact Voltage (V)
0
80
90
100
110
120
130
Percentage Of Nominal Coil Voltage
Remark:
1. Carve A: HF32FV-G standard
Carve B: HF32FV-G sensitive(no suffix 590)
Carve C: HF32FV-T sensitive(suffix 590)
Testing conditions:
10A at 85 .
Mounting distance: 10mm
Carve D: HF32FV-T standard
2. Testing conditions:
HF32FV-G Standard: flux proofed, resistive load,
10A/250VAC, at room temp. 1s on 9s off.
HF32FV-G Sensitive(no suffix 590): flux proofed,
resistive load, 10A/250VAC, at room temp. 1s on 9s off.
HF32FV-G Sensitive(suffix 590): resistive load,
10A/250VAC, at 85 . 1s on 9s off.
HF32FV-T Standard: flux proofed, resistive load,
10A/250VAC, 105 . 1s on 9s off.
Disclaimer
The specification is for reference only. See to "Terminology and Guidelines" for more information. Specifications subject to change without notice.
We could not evaluate all the performance and all the parameters for every possible application. Thus the user should be in a right position to
choose the suitable product for their own application. If there is any query, please contact Hongfa for the technical service. However, it is the user’s
responsibility to determine which product should be used only.
© Xiamen Hongfa Electroacoustic Co., Ltd. All rights of Hongfa are reserved.
139