0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
HFD3/5-L1SR(257)

HFD3/5-L1SR(257)

  • 厂商:

    HONGFA(宏发)

  • 封装:

  • 描述:

    HFD3 Series 2 A DPDT 5 VDC Subminiature PCB Through Hole Signal Relay

  • 数据手册
  • 价格&库存
HFD3/5-L1SR(257) 数据手册
HFD3 SUBMINIATURE SIGNAL RELAY Features File No.:E133481 ● Surge withstand voltage up to 2500VAC, meets FCC Part 68 and Telecordia ● Meets EN60950 / EN41003 ● SMT and DIP types available ● Bifurcated contacts ● Single side stable and latching type available V D E File No.:40018867 File No.:CQC1400207409 RoHS compliant CHARACTERISTICS CONTACT DATA Contact arrangement 2C Contact resistance 100m max.(at 10mA 30mVDC) Contact material AgNi + Au plated 2A 30VDC Contact rating (Res. load) 3A 30VDC 0.5A 125VAC Max. switching current 4A Max. switching voltage 277VAC / 220VDC Max. switching power 62.5VA / 90W 1) Min. applicable load 10mV 10µA Mechanical endurance 2) Electrical endurance 1 x 10 8 OPS 1 x 105OPS (0.5A 125VAC, Resistive load, AgNi + Au plated, at 85 C, 1s on 9s off) o Notes: 1) Min. applicable load is reference value. Please perform the confirmation test with the actual load before production since reference value may change according to switching frequencies, environmental conditions and expected contact resistance and reliability. 2) Electric endurance data are collected in one pair CO contact test. Insulation resistance 1000M (at 500VDC) 1) Between coil & contacts Dielectric strength Between open contacts Between contact sets 2000VAC 1min 1000VAC 1min 1500VAC 1min Surge withstand voltage Between open contacts (10/160µs) Between coil & contacts (2/10µs) 1500VAC (FCC part 68) 2500VAC (Telecordia) Operate time (Set time) 4ms max. Release time (Reset time) 4ms max. Ambient temperature -40 Humidity Vibration resistance Shock resistance 10Hz to 55Hz 3.3mm DA 2 Functional 735m/s Destructive 980m/s 2 Termination DIP, SMT Unit weight Approx. 2g Moisture sensitivity levels (Only for SMT type, JEDEC-STD-020) MSL-3 Plastic sealed Construction SAFETY APPROVAL RATINGS to 85 5% to 85% RH Notes: 1) The data shown above are initial values. 2) UL insulation system: Class A 2A 30VDC at 85 UL/CUL AgNi + Au plated 3A 30VDC at 85 COIL 0.5A 125VAC at 85 VDE AgNi + Au plated 2A 30VDC at 85 3A 30VDC at 70 0.5A 125VAC at 85 Coil power Single side stable Approx. 140mW 1 coil latching Approx. 100mW 2 coils latching Approx. 200mW Temperature rise 50K max. Notes: 1) All values unspecified are at room temperature. 2) Only typical loads are listed above. Other load specifications can be available upon request. HONGFA RELAY ISO9001, ISO/TS16949 , ISO14001, OHSAS18001, IECQ QC 080000 CERTIFIED 2020 Rev. 1.01 61 COIL DATA at 23 Single side stable Coil Code Nominal Voltage (1) VDC Set Voltage VDC max.(1) VDC 1.13 Reset Voltage VDC max. Max. Voltage (4) VDC 16 x (1 10%) 140 3.0 HFD3/1.5 1.5 HFD3/2.4 2.4 1.8 0.24 41 x (1 10%) 140 4.8 3 2.25 0.3 64.3 x (1 10%) 140 6.0 4.5 3.38 0.45 145 x (1 10%) 140 9.0 HFD3/5 5 3.75 0.5 178 x (1 10%) 140 10 HFD3/6 6 4.5 0.6 257 x (1 10%) 140 12 HFD3/9 9 6.75 0.9 579 x (1 10%) 140 18 HFD3/12 12 9 1.2 1028 x (1 10%) 140 24 HFD3/24 24 18 2.4 4114 x (1 10%) 140 48 HFD3/48 48 36 4.8 8533 x (1 10%) 270 96 Nominal Voltage (1) VDC Reset Voltage VDC(1) max. Coil Resistance Nominal Power mW approx. Max. Voltage (4) VDC HFD3/3 HFD3/4.5 0.15 Nominal Power mW approx. Coil Resistance 1 coil latching HFD3/1.5-L1 1.5 Set Voltage VDC max.(1) VDC 1.13 1.13 22.5 x (1 10%) 100 3.0 HFD3/2.4-L1 2.4 1.8 1.8 58 x (1 10%) 100 4.8 3 2.25 2.25 90 x (1 10%) 100 6.0 4.5 3.38 3.38 203 x (1 10%) 100 9.0 HFD3/5-L1 5 3.75 3.75 250 x (1 10%) 100 10 HFD3/6-L1 6 4.5 4.5 360 x (1 10%) 100 12 HFD3/9-L1 9 6.75 6.75 810 x (1 10%) 100 18 HFD3/12-L1 12 9 9 1440 x (1 10%) 100 24 HFD3/24-L1 24 18 18 5760 x (1 10%) 100 48 Nominal Voltage (1) VDC Set Voltage VDC max.(1) VDC Reset Voltage VDC(1) max. Coil Resistance HFD3/1.5-L2 1.5 1.13 1.13 HFD3/2.4-L2 2.4 1.8 1.8 Coil Code HFD3/3-L1 HFD3/4.5-L1 2 coils latching Coil Code HFD3/3-L2 Nominal Power mW approx. Max. Voltage (4) VDC 11.2 x (1 10%) 200 3.0 29 x (1 10%) 200 4.8 3 2.25 2.25 45 x (1 10%) 200 6.0 4.5 3.38 3.38 101 x (1 10%) 200 9.0 HFD3/5-L2 5 3.75 3.75 125 x (1 10%) 200 10 HFD3/6-L2 6 4.5 4.5 180 x (1 10%) 200 12 HFD3/9-L2 9 6.75 6.75 405 x (1 10%) 200 18 HFD3/12-L2 12 9 9 720 x (1 10%) 200 24 HFD3/24-L2 24 18 18 2880 x (1 10%) 200 48 HFD3/4.5-L2 Notes: (1) Energizing coil with rated voltage is basic for normal operation of a relay. Please make sure the energized voltage to relay coil have reached the rated voltage. (2) In case 5V of transistor drive circuit, it is recommended to use 4.5V type relay, and 3V to use 2.4V type relay. (3) For monostable relays,if you need to drop down voltage and hold mode after reliably operating,make sure that the effective value of holding voltage is not less than 60% of the rated voltage. (4) Maximum voltage refers to the maximum voltage which relay coil could endure in a short period of time. (5) When user's requirements can't be found in the above table, special order allowed. 62 ORDERING INFORMATION HF D 3 / 24 - L2 R S (XXX) Type Coil voltage Sort Terminal type Packing style 1) 1.5, 2.4, 3, 4.5, 5, 6, 9, 12, 24, 48VDC L1: 1 coil latching L2: 2 coils latching Nil: Single side stable S: Standard SMT S1: Short terminal SMT Nil: DIP R: Tape and reel packing (Only for SMT type) 2) Nil: Tube packing(Only for DIP type) Special code3) XXX: Customer special requirement Nil: Standard Notes: 1) 48VDC coil voltage is only for single side stable version. 2) R type (tape and reel) packing is moisture-proof which meets requirement of MSL-3. Please choose R type packing for SMT products. For R type, the letter "R" will only be printed on packing tag but not on relay cover. Tube packing is normally not available for SMT products unless specially requested by customer. But please note that tube packing is not moisture-proof so please bake the products before use according to description of Notice 11 herewith. In addition, tube packaging will be adopted when the ordering quantity of R type is equal to or less than 100 pieces unless otherwise specified. 3) When coil sort, terminal type or packing style are needed, pleaes add "-" after coil voltage is selected. For instance, HFD3/12-SR. 4) The customer special requirement express as special code after evaluating by Hongfa. e.g.(131): The Dielectric strength between coil & contacts is 3000VAC 1min for single side stable and 1 coil latching version. 5)The standard tube length is 624mm,Any special requirement needed, please contact us for more details. 6) For products that should meet the explosion-proof requirements of "IEC 60079 series",please note [Ex] after the specification while placing orders.Not all products have explosion-proof certification,so please contact us if necessary, in order to select the suitable products. OUTLINE DIMENSIONS, WIRING DIAGRAM AND PC BOARD LAYOUT 2 coils latching Single side stable & 1 coil latching 7.5 15 Unit: mm 15 7.5 Outline Dimensions (DIP type) 0.5 0.5 5.08 Single side stable & 1 coil latching 8xØ1 5.08 1.15 1.15 2.54 2 coils latching 10xØ1 2.54 PCB Layout (DIP type) (Bottom view) 63 OUTLINE DIMENSIONS, WIRING DIAGRAM AND PC BOARD LAYOUT 2 coils latching Single side stable & 1 coil latching 7.5 15 Unit: mm 7.5 15 Outline Dimensions (S type: Standard SMT) 0.5 0.5 5.08 1.15 9.3 Single side stable & 1 coil latching PCB Layout 1 5.08 1.15 9.3 2 coils latching 1 2.54 2.54 (S type: Standard SMT) (Bottom view) 2 coils latching Single side stable & 1 coil latching 7.5 15 7.5 15 Outline Dimensions (S1 type: Short terminal SMT) 0.5 7.5 7.5 1.15 Single side stable & 1 coil latching PCB Layout 1 5.08 0.5 5.08 1.15 2 coils latching 1 2.54 2.54 (S1 type: Short terminal SMT) (Bottom view) Single side stable 1 3 4 5 12 10 9 8 1 coil latching 2 coils latching 1 3 4 5 12 10 9 8 1 3 4 5 6 12 10 9 8 7 Wiring Diagram (Bottom view) Orientation mark No energized condition Orientation mark Reset condition Orientation mark Reset condition Remark: 1) In case of no tolerance shown in outline dimension: outline dimension ≤1mm, tolerance should be ±0.2mm; outline dimension >1mm and ≤5mm, tolerance should be ±0.3mm; outline dimension >5mm, tolerance should be ±0.4mm. 2) The tolerance without indicating for PCB layout is always ±0.1mm. 3) The width of the gridding is 2.54mm. 64 TAPE PACKING Unit: mm Direction of Relay Insertion I Reel 4:1 Orientation mark Cover tape Feed direction Embossed carrier tape Notes: 1) Packing: 400pcs/reel, 5 reels/carton. 2) MOQ for reel packing is 800pcs. I adhesive tape Cover tape Cover tape adhesive tape Feed direction during customer usage at least 5 empty relay positions at least 5 empty relay positions Reel Dimensions 13 29.4 0.2 2 0.3 24.4 1 1.6 3-R1 21 0.5 Tape Dimensions (S type: Standard SMT) A-A 4 B-B 1.5 2 B 。 20 A 0.05 。 A 2min. 。 3 max. 10 16 0.5 3 max B 0.2 (3.5) 9.9 65 TAPE PACKING Unit: mm Tape Dimensions (S1 type: Short terminal SMT) A-A 4 B-B 1.5 2 0.5 。 B 0.05 3 max 。 20 A A 2min. 。 3 max. 8.2 16 0.2 (3.5) B 9.9 CHARACTERISTIC CURVES MAXIMUM SWITCHING POWER REFLOW WELDING,TEMPERATURE ON PCB BOARD ENDURANCE CURVE RECOMMENDED WELDING TEMPERATURE 1000V 500 Temperature ( ) AC Resistive Load 100V 30VDC Resistive Load 100 100mA 180 125VAC Resistive Load 10 10mV 10uA 220 DC Resistive Load 10V Soldering max.245 50 30V max. 3 /s Preheating 150 max. 6 /s 1 1A 10A Contact Current 0 1 2 3 Contact Current (A) max. 60 max. 100 Time(s) max. 100 max. 280 Test conditions: o Resistive load, at 85 C, 1s on 9s off. Notice 1) This relay is highly sensitive polarized relay, if correct polarity is not applied to the coil terminals, the relay does not operate properly. 2) To avoid using relays under strong magnetic field which will change the parameters of relays such as pick-up voltage and drop-out voltage. 3) Relay is on the “reset” status when being released from stock, with the consideration of shock risen from transit and relay mounting, it should be changed to the “set” status when application(connecting to the power supply). Please reset the relay to “set” or “reset” status on request. 4) Energizing coil with rated voltage is basic for normal operation of a relay, please make sure the energized voltage to relay coil have reached the rated voltage. Regarding latching relay, in order to maintain the "set" or "reset" status, impulse width of the rated voltage applied to coil should be more than 5 times of "set" or "reset" time. 5) For a monosteady state relay, after the relay is reliably operated, if it needs to be kept under pressure, make sure that the effective value of the voltage is not less than 60 % of the rated voltage; 6) For 2 coil latching relay,do not emergize voltage to "set" coil and "reset" coil simultaneously. 7) The relay may be damaged because of falling or when shocking conditions exceed the requirement. 8) For SMT products, validation with real application should be done before your series production, if the reflow-soldering temperature curve is out of our recommendation. Generally, two-time reflow-soldering is not recommended for the relay. However, if two-time reflow-soldering is required, a 60-min. interval should be guaranteed and a validation should be done before production. 9) Please use wave soldering or manual soldering for straight-in relay. If you need reflow welding, please confirm the feasibility with us. 10)Contact is recommended for suitable condition and specifications if water cleaning or surface process is involved in assembling relays on PCB. o 11)Regarding the plastic sealed relay, we should leave it cooling naturally untillo below 40 C after welding, then clean it and deal with coating, remarkably the temperature of solvents should also be controlled below 40 C.Please avoid cleaning the relay by ultrasonic, avoid using the solvents like gasoline, Freon, and so on, which would affect the configuration of relay or influence the environment. 12) Relays packaged in moisture barrier bags meet MSL-3 requirements. The relays should be stored at ambient conditions of ≤30℃ and ≤60% RH after they are removed from their packaging, and should be used within 168 hours. If the relays cannot be used within 168 hours, please repack them or store them in a drying oven at 25℃±5℃, ≤10% RH. Otherwise, relays may be subjected to a soldering test to check their performance, or they may be used after keeping them in an oven for 72 hours at with 50℃±5℃, ≤30% RH. 13) When applied with continuous current, the heat from relay coil will age its isolation. Thus, please do not ground connected the coil to reduce electrical errosion if possible. And please provide protection circuit to avoid broken wire and losses. 14)Please make sure that there are no silicon-based substances (such as silicon rubber, silicone oil, silicon-based coating agents, silicon fillers, etc.) around the relay, because it will generate silicon-containing volatile gas, which may cause poor contact in case of silicon-containing volatile gas sticking on contact 15) About preferable condition of operation, storage and transportation, please refer to "Explanation to terminology and guidetines of relay". Disclaimer The specification is for reference only. See to "Terminology and Guidelines" for more information. Specifications subject to change without notice. We could not evaluate all the performance and all the parameters for every possible application. Thus the user should be in a right position to choose the suitable product for their own application. If there is any query, please contact Hongfa for the technical service. However, it is the user’s responsibility to determine which product should be used only. © Xiamen Hongfa Electroacoustic Co., Ltd. All rights of Hongfa are reserved. 66
HFD3/5-L1SR(257) 价格&库存

很抱歉,暂时无法提供与“HFD3/5-L1SR(257)”相匹配的价格&库存,您可以联系我们找货

免费人工找货