HFE10-L/24-DT-L1(257) 数据手册
Features
50A switching capacity
1.5mm contact gap available
Rated power
Single coil latching: Approx. 1.5W
Double coils latching: Approx. 3.0W
Type W-Single coil latching:Approx. 2.4W
Type W-Double coils latching Approx. 4.8W
(between input and output side)
See“contact rating”
Nominal
Pulse
Voltage Set / Reset Voltage
Duration
1)
VDC
VDC
ms min.
6
≤4.8
≥50
Coil Resistance
x (1±10%) Ω
24
9
≤7.2
≥50
12
≤9.6
≥50
24
≤19.2
≥50
48
≤38.4
≥50
1536
6
≤4.8
≥50
12+12
9
≤7.2
≥50
12
≤9.6
≥50
24
≤19.2
≥50
48
≤38.4
≥50
Single coil
latching
54
96
384
Double coils
latching
27+27
48+48
192+192
768+768
Notes:1) The data shown above are initial values.
2) The above set voltage, reset voltage are the test value for relay
without load. Please use 1~1.5 times of rated voltage to drive
the relay for your application.
ISO9001 IATF16949 ISO14001 OHSAS18001 IECQ QC 080000 CERTIFIED
2021 Rev.1.00
1
COIL DATA
Type W-Single coil latching
Nominal
Voltage Set / Reset Voltage
VDC max. 1)
VDC
Type W-Double coils latching
Pulse
Duration
ms min.
Coil Resistance
x (1±10%) Ω
Nominal
Voltage Set / Reset Voltage
VDC max. 1)
VDC
Pulse
Duration
ms min.
Coil Resistance
x (1±10%) Ω
≥50
15
≥50
7.5+7.5
≥50
33.8
≥50
16.9+16.9
≥50
60
≥50
30+30
≥50
240
≥50
120+120
≥50
960
≥50
480+480
Notes:1) The data shown above are initial values.
2)The above set voltage, reset voltage are the test value for relay without load. Please use 1~1.5 times of rated voltage to drive the relay for
your application.
3) W-type for special code (W).
Contact
arrangement
(Not applicable to HFE10-5)
Extended terminal
Extended bending terminal
Coil type
R: Reverse polarity
Nil: Standard polarity
Only for 1 form A, without certification.
The termination type 1, type 5, type 6, type7 are
2
5.1
+0.4
-0.2
Not applicable to
normally open type
Double coil type only
5.2 ±0.2
Double coil type only
3
Double coil type only
Double coil type only
4
Double coil type only
5.1
+0.4
-0.2
Double coil type only
5
Standard polarity
Reverse polarity
6
Standard polarity
Reverse polarity
7
CAUTIONS
1.The recommended soldering temperature range is 250±10°C with the duration of 2 5s. It is not suggested to apply reflow
soldering method, if it is required indeed, please contact with our technicians. It is general required that the wave soldering
temperature at 250°C shall not more than 2s.
2. Latching relay is on the "reset" or "set" status when delivery, with the consideration of shock risen from transit and relay mounting,
relay would be changed to "set" or "reset" status, therefore, when application ( connecting the power supply), please reset the
relay to "set" or "reset" status on request.
3. In order to maintain "set" or "reset" status, energized voltage applied across the coil should reach the rated voltage, impulse
width should be 5 times more than "set" or "reset" time. Do not energize voltage to "set" coil and "reset" coil simultaneously.
And also long energized time (more than 1 min) should be avoided.
HFE10-L/24-DT-L1(257) 价格&库存
很抱歉,暂时无法提供与“HFE10-L/24-DT-L1(257)”相匹配的价格&库存,您可以联系我们找货
免费人工找货- 国内价格 香港价格
- 10+16.4380810+1.96470
- 25+16.2523425+1.94250
- 50+16.0666050+1.92030
- 150+15.78799150+1.88700
- 300+15.41651300+1.84260