HFE7
SUBMINIATURE INTERMEDIATE POWER RELAY
Features
● High switching capacity
1A, 1B: 10A 250VAC/30VDC;
2A, 2B, 1A + 1B: 8A 250VAC/30VDC
● High sensitive
● 4kV dielectric strength (between coil & contacts)
● Single side stable and latching types available
● 1 Form A, 1 Form B, 2 Form A, 2 Form B and 1A + 1B
contact arrangement
File No.:E134517
V
D E
File No.:40027342
RoHS compliant
CONTACT DATA
COIL
Contact arrangement
1A, 1B
2A, 2B, 1A +1B
AgNi +Au plated: 30m max.(at 1A 6VDC)
Contact resistance
AgNi: 50m max.(at 1A 6VDC)
AgSnO2 +Au plated: 60m max.(at 1A 6VDC)
AgSnO2: 80m max.(at 1A 6VDC)
Contact material
Contact rating
(Res. load)
AgSnO2, AgNi
10A 250VAC/30VDC
Max. switching Voltage
277VAC
Max. switching current
10A
Max. switching power
2500VA
8A 250VAC/30VDC
277VAC
8A
2000VA
1 x 107OPS
Mechanical endurance
5
Electrical endurance
1A, 1B type: 1 x 10 OPS (10A 250VAC,
Resistive load., at 70℃, 1.5s on 1.5s off)
1A +1B, 2A, 2B type: 3 x 104OPS
(8A 250VAC, Resistive load.,
at 70℃, 1.5s on 1.5s off)
CHARACTERISTICS
Insulation resistance
1000M
Dielectric Between coil & contacts
Strength Between open contacts
(at 500VDC)
4000VAC 1min
1000VAC 1min
Operate time (at rated. volt.)
10ms max.
Release (Reset) time
(at nomi. volt.)
10ms max.
Approx. 420mW
Single coils latching
Approx. 300mW
Approx. 200mW
Double coils latching
Approx. 420mW
Approx. 280mW
Approx. 200mW
Approx. 280mW
COIL DATA
at 23
Single side stable
Nominal
Voltage
VDC
Pick-up
Voltage
VDC
max.
Drop-out
Coil Resistance
Voltage
x (1 10%)
VDC
200mW 280mW 420mW
min.
3
2.1
0.3
45
32.1
21.4
5
3.5
0.5
125
89.3
59.5
6
4.2
0.6
180
129
85.7
405
289
192.9
9
6.3
0.9
12
8.4
1.2
720
514
342.9
24
16.8
2.4
2880
2056
1371.4
Single coil latching
Coil Resistance
x (1 10%)
Nominal
Voltage
VDC
Set /Reset
Voltage
VDC
max.
Pulse
Duration
ms
min.
300mW
200mW
3
2.1
50
30
45
5
3.5
50
83.3
125
50 K max.
6
4.2
50
120
180
10Hz to 55Hz 1.5mm DA
9
6.3
50
270
405
Temperature rise (at rated. volt.)
2
12
8.4
50
480
720
5% to 85% RH
24
16.8
50
1920
2880
Shock resistance
98m/s
Humidity
Ambient temperature
-40
to 70
Termination
PCB
Unit weight
Approx. 6g
Construction
High sensitive
Sensitive
1A,1A+1B
Single
side stable
2A
20 cycles /min
Max. operate frequency
(under rated load)
Vibration resistance
Coil power
Type
Plastic sealed, Flux proofed
Notes: The data shown above are initial values.
HONGFA RELAY
ISO9001, ISO/TS16949 , ISO14001, OHSAS18001, IECQ QC 080000 CERTIFIED
206
2019 Rev. 1.00
COIL DATA
at 23
Double coils latching
Set / Reset Voltage
Nominal Voltage
VDC
VDC
max.
3
2.1
5
3.5
6
4.2
9
6.3
12
8.4
24
16.8
Pulse Duration
ms
min.
50
50
50
50
50
50
Coil Resistance x (1 10%)
420mW
21.4+21.4
59.5+59.5
85.7+85.7
192.9+192.9
342.9+342.9
1371.4+1371.4
280mW
32.1+32.1
89.3+89.3
129+129
289+289
514+514
2056+2056
SAFETY APPROVAL RATINGS
AgNi
1 Form A
AgSnO2
UL/CUL
AgSnO2, AgNi
2 Form A
AgSnO2
AgSnO2, AgNi
1 Form A+1 Form B
AgSnO2
VDE
(No UL approval
on Single side
stable version)
1 Form A
AgNi
2 Form A
AgNi
1 Form A+1 Form B
AgNi
Notes: 1) All values unspecified are at room temperature.
2) Only typical loads are listed above. Other load specifications can be available upon request.
10A 250VAC
8A 30VDC
1/4HP 125VAC
1/3HP 250VAC
10A 30VDC
B300, R300
10A 250VAC
1/4 HP 125VAC
1/3 HP 250VAC
8A 250VAC/30VDC
1/4HP 125VAC
1/3HP 250VAC
600W 125VAC
B300, R300
8A 250VAC/30VDC
1/4HP 125VAC
1/3HP 250VAC
B300, R300
10A 250VAC (cosØ=1)
5A 250VAC (cosØ=0.4)
8A 250VAC (cosØ=1)
3.5A 250VAC(cosØ=0.4)
8A 250VAC (cosØ=1)
3.5A 250VAC (cosØ=0.4)
ORDERING INFORMATION
HFE7 /
12
-1H
S
T
G -L 2 - R (412) (XXX)
Type
Coil voltage
3, 5, 6, 9, 12, 24VDC
1)
Contact form
Construction
1H: 1 Form A 1D: 1 Form B
2H: 2 Form A 2D: 2 Form B 1HD: 1A + 1B
2)
Contact material
S: Plastic sealed
3)
Nil: Flux proofed
T: AgSnO2
Nil: AgNi
Contact plating
G: Gold plated
Nil: No gold plated
Sort
L1: 1 coil latching
L2: 2 coils latching Nil: Single side stable
Polarity
R: Negative polarity
Customer special code (Coil power)
Special
code5)
4)
Nil: Positive polarity
(412): Sensitive
XXX: Customer special requirement
Nil: High sensitive
Nil: Standard
Notes: 1) 1H, 2H means that relay is on the "reset" status when delivery; 1D, 2D means that relay is on the "set" status when delivery.There are
no UL approval on 1D,2D version.
2) Under the ambience with dangerous gas like H2S, SO2 or NO2, plastic sealed type is recommended; Please test the relay in real applications.
If the ambience allows, flux proofed type is preferentially recommended. Contact is recommended for suitable condition and specifications
if water cleaning or surface process is involved in assembling relays on PCB.
3) For the application with inrush current conditions, such as lamp load, motor load, capacitance load, coil load, etc., we suggest use the
flux proof and no golden plated AgSnO2 contact version.
4) We recommend to choose the sensitive version (same part number, but with special suffix (412)) if the higher coil activation is allowable; Please
choose the sensitive version (same part number, but with special suffix (412)) if the relay to be used in the extreme environment or welded by wave
soldering; Please check with HF's engineer before designing the relay to your application if there are some requirements' outside the specification we provided.
5) The customer special requirement express as special code after evaluating by Hongfa. e.g. (359) stands for Lamp load.
207
OUTLINE DIMENSIONS, WIRING DIAGRAM AND PC BOARD LAYOUT
Unit: mm
Outline Dimensions
2 coils latching
Single side stable & 1 coil latching
0.8
1.25
10.16
20
15
20
2.54
0.5
7.62
15
10.16
1.25
10.16
0.5
0.8
7.62
10.16
PCB Layout (Bottom view)
2 coils latching
Single side stable & 1 coil latching
1 Form A,1 Form B
4xØ1.2
1 Form A,1 Form B
2 Form A, 2 Form B,1A + 1B
2.54
6xØ1.2
2 Form A, 2 Form B,1A + 1B
2.54
2.54
2.54
8x Ø1.2
6xØ1.2
Remark: 1) In case of no tolerance shown in outline dimension: outline dimension ≤1mm, tolerance should be ±0.2mm; outline dimension >1mm
and ≤5mm, tolerance should be ±0.3mm; outline dimension >5mm, tolerance should be ±0.4mm.
2) The tolerance without indicating for PCB layout is always ±0.1mm.
3) The width of the gridding is 2.54mm.
Wiring Diagram (Bottom view)
Single side stable (Standard polarity)
1 Form A
208
2 Form A
1A + 1B
OUTLINE DIMENSIONS, WIRING DIAGRAM AND PC BOARD LAYOUT
Unit: mm
Wiring Diagram (Bottom view)
1 coil latching (Standard polarity)
1 Form A
2 Form A
1 Form B
2 Form B
1A + 1B
2 coils latching (Standard polarity)
1 Form A
1 Form B
2 Form A
1A + 1B
2 Form B
Remark: The coil polarity of Reverse polarity and Standard polarity is opposite.
Notice
1. Relay is on the “reset” or "set" status when being released from stock, with the consideration of shock risen from transit and relay mounting, relay
would be changed to “set” or "reset" status, therefore, when application ( connecting the power supply), please reset the relay to “set” or “reset”
status on request.
2. In order to maintain “set” or “reset” status, energized voltage to coil should reach the rated voltage, impulse width should be 5 times more than
“set” or “reset” time. Do not energize voltage to “set” coil and “reset” coil simultaneously. And also long energized time (more than 1 min) should
be avoided.
3. As the relay component part's will shrink and deformed due to the high temperature impact, our products are forbidden to be used at the temperature
outside our suggested working temperature range (-40℃ to 70℃) for long time ; If the wave soldering will be used, the operating parameters we
will suggest are: Up limit of the pre-heating time: 120s; Up limit of the pre-heating temperature:120℃; Soldering temperatuer: 260℃±5℃; Soldering
time(10±3)s; Besides our suggested parameters, please try to shorten the pre-heating time and the soldering time and try to lower the temperature
for pre-heating and the soldering as you can; the manual soldering for such relay is more recommended.
Disclaimer
This datasheet is for the customers’ reference. All the specifications are subject to change without notice.
We could not evaluate all the performance and all the parameters for every possible application. Thus the user should be in a right position to
choose the suitable product for their own application. If there is any query, please contact Hongfa for the technical service. However, it is the user’s
responsibility to determine which product should be used only.
© Xiamen Hongfa Electroacoustic Co., Ltd. All rights of Hongfa are reserved.
209