Catalog 1308242
Issued 3-03 (PDF Rev. 9-07)
P&B
KU series
KUP Enclosed Relay
KUIP 8mm Coil to Contacts
KUGP 3mm Contact Gap, 8mm Coil to Contacts
KUEP 10 Amp 150VDC Load Switching
KUMP 15 Amp 277VAC
File E22575
File LR15734
RoHS
Users should thoroughly review the technical data before selecting a product
part number. It is recommended that users also seek out the pertinent approvals
files of the agencies/laboratories and review them to ensure the product meets
the requirements for a given application.
Ready
Features
Coil Data @ 25°C
• AC coils: 6-240VAC, 50/60 Hz. DC: 6-110VDC.
• Contact arrangement up to 4PDT.
• Wide selection of termination and mounting styles.
• PC terminals available.
• Push to test button and indicator lamps.
• KUEP incorporates a blow out magnet for high voltage DC switching.
• KUIP offers 8mm contact-to-coil spacing for a higher degree of isolation.
• KUGP provides 3mm contact gap and 8mm contact-to-coil spacing.
• Complete line of sockets and DIN rail.
• Class B coil insulation.
Voltage: 6 to 110VDC and 6 to 240VAC.
Nominal Coil Power:
DC Coils: 1.2 Watts - KUP, KUIP, KUMP, 1 - 3 pole; KUEP, 1 pole.
DC Coils: 1.8 Watts - KUP, 4 pole; KUEP, 2 pole; KUGP.
AC Coils: 2.0VA - KUP, KUIP, 1 - 2 pole; KUEP, 1 pole.
AC Coils: 2.7VA - KUP, KUIP, 3 pole; KUEP, 2 pole; KUGP, KUMP.
Coil Data
Contact Data @ 25°C
Arrangements: See respective ordering information table.
Materials: Fine silver (5 amp) silver-cadmium oxide (10 amp).
Gold flash available as standard.
Gold diffused and gold alloy on special order.
Expected Mechanical Life:
Contact Ratings
Material
Fine
Silver
SilverCadmium
Oxide
Arrangement
All
1-2 Pole
KUP
KUIP
KUGP
KUEP
All KUMP
KUMP
3 Pole
KUP
KUIP
4 Pole
KUEP
SPST-NO
KUEP
2PST-NO
KUEP
2PDT
UL/CSA Ratings
5 amps @ 28VDC or 240VAC
80% PF, 2.5 amp tungsten
@120VAC, 1/2 amp @ 120VDC.
1/6 HP @120VAC, 1/3 HP @
240VAC, 5 FLA, 15 LRA @
250VAC (FLA covered by
30,000 operations).
10 amps @ 28VDC or 240VAC,
80% PF, 5 amp tungsten @
120VAC, 3A 600VAC, 1/2 amp
@ 120VDC.
1/3 HP @ 120VAC, 1/2 HP @
240, 480, and 600VAC, 10 FLA
30 LRA @ 120VAC, 5 FLA,
15 LRA @ 250VAC.(FLA ratings
covered by 30,000 operations)
15 amp @ 277VAC, 80% PF
KUM KUMP
10 amp @ 28VDC or 120VAC,
80% PF, 6 2/3 amp @ 240VAC,
80% PF
10 amp per pole not to exceed
30 amp total @ 28VDC, 120VAC,
80% PF, 6 2/3 amp @ 240VAC,
80% PF
Expected
Life
100,000
1.2 Watt
1.8 Watt
DC Ohms ± 10% Nom. I ma DC Ohms ± 10% Nom. I ma
21
238
14
360
32.1
187
20
300
120
100
80
150
472
51
320
75
1,800
26.7
1,260
38
10,000
11
6,720
16
AC Volts
Nominal
2VA
DC Ohms ± 15%
6
12
24
120
240
100,000
6
24
85
2,250
9,110
335
168
84
17.5
8.75
4.2
18
72
1,700
7,200
460
230
115
24
12
Must Operate Voltage:
DC Coils: 75% of nominal voltage or less.
AC Coils: 85% of nominal voltage or less.
Operating Time (Excluding Bounce):
15 milliseconds, typical, at nominal voltage.
Release Time (Excluding Bounce):
10 milliseconds, typical, at nominal voltage.
100,000
100,000
Environmental Data
100,000
5 amp @ 150VDC
100,000
(All other AC ratings apply KUEP.)
Temperature Range:
Operating: Enclosed Relays: -45°C to maximum listed in table below.
Open Relays: Add 15°C to maximum listed.
Max C°
+45°C
+50°C
KUP
AC
3-4 pole
DC
4 pole
KUIP
KUGP
Initial Dielectric Strength
KUEP
Between Open Contacts: 1,200V rms; KUGP, 3,500V rms.
Between Adjacent Contacts: 2,200V rms.
Between Contacts and Coil: 2,200V rms; KUGP, KUIP, 3,750V rms.
KUMP
Dimensions are shown for
reference purposes only.
2.7VA
Nom. I ma DC Ohms ± 15% Nom. I ma
Operate Data @ 25°C
10 amp @ 150VDC
3 amp @ 150VDC
DC Volts
Nominal
5
6
12
24
48
110
Dimensions are in inches over
(millimeters) unless otherwise
specified.
AC
2 pole
AC
3 pole
Specifications and availability
subject to change.
+55°C
+70°C
AC
DC
1-2 pole 1-3 pole
AC
3 pole
AC
2 pole
AC
DC
1 pole 1-2 pole
AC
DC
1-2 pole 1-3 pole
+75°C
+80°C
+95°C
AC
1-2 pole
DC
1-3 pole
DC
2 pole
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
723
Catalog 1308242
Issued 3-03 (PDF Rev. 9-07)
Environmental Data (Continued)
40°
OI
30°
L
OI
.C
Hz
L
20°
Co
il
60
30°
Co
il
.C
Hz
W
at
tD
C
60
1.
8
60°
50°
VA
40°
W
at
tD
C
7
2.
50°
1.2
Max. Ambient Temp. °C
60°
Termination: Quick connect, solder and PC board.
Enclosure: Clear polycarbonate dust cover.
Weight: 3.0 oz. (85g) approximately.
75°
70°
A
0V
2.
Max. Ambient Temp. °C
Maximum Allowable Ambient Temperature vs. Voltage (KUP enclosed)
75°
70°
P&B
Mechanical Data
20°
100 110 120 130 140 150 160
% of Nominal Voltage DC
120
130
140
100
110
% Of Nominal 60 Hz. Voltage
Ordering Information
Typical Part No. >
1. Basic Series & Type:
KU = Basic open relay.
KUP = Basic enclosed relay.
2.
Contact Arrangement:
1 = 1A (SPST-NO)
5 = 1C (SPDT)
11 = 2C (DPDT)
KU
KUP
-14
A
1
5
F
-120
14 = 3C (3PDT)
17 = 4C (4PDT)
3.
Coil Input:
A = AC 50/60 Hz.
D = DC
4.
Mountings:
Type
KU
Codes
Available
1,3,4
OPEN STYLE
1 = #6-32 stud, .218" (5.54mm) locating tab.
3 = #6-32 tapped core, .125" (3.18mm) locating tab.
4 = #6-32 tapped core, .218" (5.54mm) locating tab.
KUP (through 3 poles)
KUP (4 pole models)
1,2,3,4,5,
A,E,T
1,3,5,A,E
1 = PLAIN CASE;
2 = with test button.
3 = with indicator lamp.*
4 = with test button & indicator lamp.*
5 = BRACKET MOUNT CASE.
A = PLAIN CASE, #6-32 stud, locating tab.
E = PLAIN CASE, tapped core, locating tab.
T = TOP FLANGE CASE.
* Indicator lamps are available on models with the following coils:
6-24VAC and DC, 110VDC and 120-240VAC. Only models with
120-240VAC coils are UL recognized.
5.
Terminal & Contact Material:
Type
1 & 2 Pole Models
Codes
1, 5, 7, K
Available
3 Pole Models
1, 5, 7
4 Pole Models
1**, 5**,7, 9
**4 pole KUP with .187" (4.75mm) quick connect/solder
terminals will not plug into sockets. Must use .110" (2.79
mm) quick connect solder terminals for socket mounting.
1 = .187" (4.75mm) quick-connect/solder; silver, 5 amps.
5 = .187" (4.75mm) quick connect/solder; silver-cadmium oxide, 10 amps.
7 = .047” (1.19mm) printed circuit; silver-cadmium oxide, 10 amps.
9 = 4 pole KU, KUP: .110" (2.79mm) quick connect/solder; silver-cadmium oxide, 10 amps.
K = .250" (6.35mm) quick connect; silver-cadmium oxide, 10 amps.
5A. Gold Flashed Contact Option:
F = Optional gold flashing for silver and silver-cadmium oxide contacts.
6.
Coil Voltage:
To 240VAC, 50/60 Hz. or 110VDC.
Note: All part numbers are RoHS compliant.
Our authorized distributors are more likely to stock the following items for immediate delivery.
KUP-5A15-24
KUP-5A15-120
KUP-5A15-240
KUP-5A55-120
KUP-5D15-12
KUP-5D15-24
KUP-5D55-12
KUP-5D55-24
KUP-11A11-120
Dimensions are shown for
724 reference purposes only.
KUP-11A15-12
KUP-11A15-24
KUP-11A15-120
KUP-11A15-240
KUP-11A35-120
KUP-11A55-24
KUP-11A55-120
KUP-11AT5-120
KUP-11D11-24
KUP-11D15-5
KUP-11D15-12
KUP-11D15-24
KUP-11D15-110
KUP-11D35-24
KUP-11D55-6
KUP-11D55-12
KUP-11D55-24
KUP-11D55-48
Dimensions are in inches over
(millimeters) unless otherwise
specified.
KUP-11D55-110
KUP-14A11-120
KUP-14A15-12
KUP-14A15-24
KUP-14A15-120
KUP-14A15-240
KUP-14A25-120
KUP-14A35-120
KUP-14A45-120
KUP-14A55-24
KUP-14A55-120
KUP-14A55-240
KUP-14D11-24
KUP-14D15-6
KUP-14D15-12
KUP-14D15-24
KUP-14D15-48
KUP-14D15-110
Specifications and availability
subject to change.
KUP-14D25-24
KUP-14D35-24
KUP-14D55-12
KUP-14D55-24
KUP-17A19-120
KUP-17A55-24
KUP-17D19-24
KUP-17D55-24
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
Catalog 1308242
Issued 3-03 (PDF Rev. 9-07)
P&B
Ordering Information
High Isolation Design
Typical Part No. >
1.
Basic Series & Type:
KUIP = Enclosed relay with 8mm contact to coil spacing.
KUGP = Enclosed relay with 3mm open contact spacing and
8mm contact to coil spacing. (Form A and Form X arrangements only)
2.
Contact Arrangement:
5 = 1 Form C (SPDT)*
7 = 2 Form A (DPST-NO)
* Not offered on KUGP model.
KUIP
KUGP
-5
A
5
5
-120
11 = 2 Form C (DPDT)*
14 = 3 Form C (3PDT)*
3.
Coil Input:
A = AC, 50/60 Hz.
D = DC
4.
Mountings:
1 = PLAIN CASE, SOCKET MOUNT.
5 = BRACKET MOUNT CASE.
T = TOP FLANGE CASE.
5.
Terminal & Contact Material:
3 = .047" (1.19mm) printed circuit board; silver.
6.
Coil Voltage:
To 240VAC, 50/60 Hz. or 110VDC. (For 277VAC, consult factory.)
5 = .187" (4.75mm) quick connect/solder; silver-cadmium oxide.
See coil data tables.
Note: All part numbers are RoHS compliant.
Our authorized distributors are more likely to stock the following items for immediate delivery.
KUGP-7D55-24
KUIP-5A55-120
KUIP-11D55-12
KUIP-11D55-24
KUIP-14A15-120
KUIP-14D15-12
KUIP-14D15-24
Ordering Information
High Voltage DC Switching
Typical Part No. >
1.
Basic Series & Type:
KUEP = Enclosed relay with magnetic blow-outs.
2.
Contact Arrangement:
3 = 1X (SPST-NO-DM)
3.
Coil Input:
A = AC 50/60 Hz.
4.
Mountings:
1 = PLAIN CASE;
3 = with indicator lamp.*
5 = BRACKET MOUNT CASE
T = TOP FLANGE CASE.
5.
6.
7 = 2A (DPST-NO)
KUEP
-3
A
1
5
-120
11 = 2C (DPDT)
D = DC
*Indicator lamps are available on models with the following coils:
6-24VAC and DC, 110VDC and 120-240VAC. Only models with
120-240VAC coils are UL recognized.
Terminal & Contact Material:
5 = .187" (4.75mm) quick connect/solder; silvercadmium-oxide.
7 = .047' (1.19mm) printed circuit; silver-cadmium-oxide.
Coil Voltage:
To 240VAC, 50/60 Hz. or 110VDC. (For 277VAC, consult factory.)
Note: All part numbers are RoHS compliant.
Our authorized distributors are more likely to stock the following items for immediate delivery.
KUEP-3A15-120
KUEP-3D15-12
KUEP-3D15-24
Dimensions are shown for
reference purposes only.
KUEP-3D15-110
KUEP-7D15-24
KUEP-11A15-120
KUEP-11D15-12
KUEP-11D15-24
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Specifications and availability
subject to change.
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
725
Catalog 1308242
Issued 3-03 (PDF Rev. 9-07)
P&B
Ordering Information
15 Amp Switching
Typical Part No. >
1.
Basic Series & Type:
KUM = 15 amp open relay
KUMP = 15 amp enclosed relay
2.
Contact Arrangement:
1 = 1A (SPST-NO)
2 = 1B (SPST-NC)
3 = 1X (SPST-NO-DM)
4 = 1Y (SPST-NC-DB)
5 = 1C (SPDT)
6 = 1Z (SPDT-NC-NO [DB-DM])
7 = 2A (DPST-NO)
8 = 2B (DPST-NC)
11 = 2C (DPDT)
12 = 3A (3PST-NO)
13 = 3B (3PST-NC)
14 = 3C (3PDT)
3.
Coil Input:
A = AC, 50/60 Hz.
4.
Mountings:
Type
KUM
OPEN STYLE
1 = #6-32 stud, .218"
(5.54mm) locating
tab.
2 = 2-hole bracket,
#6-32 tapped.
3 = #6-32 tapped core,
.125" (3.18mm)
locating tab.
4 = #6-32 tapped core,
.218" (5.54mm)
locating tab.
5 = #6-32 tapped core,
no locating tab.
5.
KUM
KUMP
-14
A
1
8
-120
D = DC
1 = PLAIN CASE;
2 = with test button.
3 = with indicator lamp.*
4 = with test button & indicator lamp.*
5 = BRACKET MOUNT CASE;
6 = with test button.
7 = with indicator lamp.*
8 = with test button & indicator lamp.*
9 = STUD ON END OF PLAIN CASE.
KUMP
A = PLAIN CASE, #6-32 STUD LOCATING TAB;
B = with test button.
C = with indicator lamp.*
D = with test button & indicator lamp.*
E = PLAIN CASE, TAPPED CORE, LOCATING TAB;
F = with test button.
G = with indicator lamp.*
H = with test button & indicator lamp.*
T = TOP FLANGE CASE.
*Indicator lamps are available on models with the following coils:
6-24VAC and DC, 110VDC and 120-240VAC. Only models with
120-240VAC coils are UL recognized.
Terminal & Contact Material:
Type
1 & 2 Pole Models
Codes
6,8,9,G
Available
3 Pole Models
6,8,9
6 = .205" (5.21mm) quick connect/solder; silver-cadmium-oxide.
8 = .187" (4.75mm) quick connect/solder; silver-cadmium-oxide.
9 = .047" (1.19mm) printed circuit; silver-cadmium-oxide.
G = .250" (6.35mm) quick connect; silver-cadmium-oxide. (Not available on 3 pole models.)
6.
Coil Voltage:
To 240VAC, 50/60 Hz. or 110VDC (For 277VAC, consult factory.)
Note: All part numbers are RoHS compliant.
Our authorized distributors are more likely to stock the following items for immediate delivery.
KUMP-11A18-24
KUMP-11A18-120
KUMP-11A18-240
Dimensions are shown for
726 reference purposes only.
KUMP-11D18-12
KUMP-11D18-24
KUMP-11D18-110
Dimensions are in inches over
(millimeters) unless otherwise
specified.
KUMP-14A18-24
KUMP-14A18-120
KUMP-14D18-12
KUMP-14D18-24
Specifications and availability
subject to change.
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
Catalog 1308242
Issued 3-03 (PDF Rev. 9-07)
P&B
Outline Dimensions
Open Relays
Bracket Type
1.437
(36.50)
.19
(4.8)
X Is For Terminal Dimensions.
See Terminal Drawings.
2.43 MAX.*
(61.72)
2.33 MAX.**
(59.18)
2.29 MAX.***
(58.17)
X
.63
(16.0)
.63
(16.0)
1.468 MAX.
(37.29)
.031 REF.
(.79)
1.391
(35.33)
.218
(5.54)
.109 MAX.
(2.77)
.065
(1.65)
.437
(11.10)
1.52" (38.6mm) for bracket
with 2-#6 32 tapped holes.
2.27 MAX.*
(57.7)
2.171 MAX.**
(55.14)
2.125 MAX.***
(53.98)
Stud Type
2.27 MAX.*
(57.7)
2.171 MAX.**
(55.14)
2.125 MAX.***
(53.98)
1.391" (35.33mm) for #6-32 stud
with .218" (5.54mm) locating tab.
X
X
.16
(4.1)
(2) #6-32 THREAD
TAPPED HOLES
1.39 MAX.*
(35.3)
1.29 MAX.**
(32.8)
1.25 MAX.***
(31.8)
1
4
2
5
3
6
7
8
9
A
1.282" (32.56mm) for #6-32 tapped core
with .125" (3.18mm) or .218" (5.54mm) locating tab.
2.046" (51.97mm) for relay
with printed circuit terminals.
STUD TYPE also available with .125" (3.18mm)
tab, as well as without stud and locating tab.
Models without stud have core tapped #6-32
THREAD, .25" (6.4mm) minimum depth.
.031 REF.
(.79)
1.282 MAX.
(35.56)
1.687 MAX.
B
(42.85)
.31
(7.9)
#6-32
THREAD
Seated Heights For Open Relays
*Dimensions with .250" (6.35mm) terminals.
**Dimensions with .110" (2.79mm) or
.205"(5.21mm) terminals.
***Dimensions with .187" (4.75mm) terminals.
.150
TAB WIDTH
(3.81)
Enclosed Relays
Plain Case
Core and Stud Mount Cases
.187 (4.75) DIA.
PUSH-TO-TEST BUTTON
AVAILABLE ON KUP,
& KUMP
.288
(7.32)
X
1
4
2
5
3
6
7
8
9
X
X
1.43 MAX.
(36.27)
1.74 MAX.
(44.2)
STUD with
#6-32 THREAD
or CORE TAPPED
#6-32
.437 ± .010
(11.10 ± .25)
1.406 MAX.
(35.71)
B
A
X Is For Terminal Dimensions.
See Teminal Drawings.
X
X
.130
(3.30)
1.531 MAX.
(38.89)
.219 MAX.
(5.56)
1.968 MAX.†
(49.99)
1.906 MAX.‡
(48.41)
1.968 MAX.†
(49.99)
1.906 MAX.‡
(48.41)
1.39 MAX.*
(35.3)
1.29 MAX.**
(32.8)
1.25 MAX.***
(31.8)
.312
(7.92)
†Dimensions with .250" (6.35mm) terminals.
Top Flange Case
‡Dimensions with .110" (2.79mm), .187"
(4.75mm and .205" 5.21mm) terminals.
1.518 MAX.
(38.56)
.078 TYP.
(1.98)
*Dimensions with .250" (6.35mm) terminals.
1
4
2
5
3
6
7
8
9
A
**Dimensions with .110" (2.79mm) or
.205" (5.21mm) terminals
1.713 ± .0 03
(43.51 ± .08)
1.373 ± .010
1.989 ± .0 03
(34.87 ± .25)
(50.52)
***Dimensions with .187" (4.75mm) terminals.
B
2.248 MAX.
(57.10)
Stud on End Case
.178 TYP.
(4.52)
.085 MAX.
(2.16)
Bracket Mount Case
2.90 MAX.
(73.7)
X
.078 R. TYP.
(1.98)
.75
(19.1)
1.531 MAX.
(38.89)
.375
(9.53)
Dimensions are shown for
reference purposes only.
2.500
(63.50)
X X
.437
(11.10)
PUSH-TO-TESTBUTTON
AVAILABLE ON KUP
& KUMP
1.406 M AX.
(35.71)
1.128
(28.65)
.312
.625 TYP. TYP.
(15.88) (7.92)
1.968 MAX. †
(49.99)
1.906 MAX. ‡
(48.41)
.38
(9.7)
.07
(1.8)
Dimensions are in inches over
(millimeters) unless otherwise
specified.
.06
(1.52)
#6-32 THREAD
.16
(4.1)
1.968 MAX.†
(49.99)
1.906 MAX.‡
(48.41)
Specifications and availability
subject to change.
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
727
Catalog 1308242
Issued 3-03 (PDF Rev. 9-07)
P&B
Outline Dimensions (Continued)
Relay Front Diagrams
Relays With
.250" (6.35mm) Terminals
1-3 Pole Relays
1.531 MAX.
(38.89)
4 Pole Relays
1.531 MAX.
(38.89)
1
4
2
5
3
6
7
8
9
A
1
4
7
1.406 MAX.
(35.71)
2
5
1.531 MAX.
(38.89)
3
6
9
11 2 2 3 34
5 6 4 7 8
1.406 MAX.
(35.71)
B
A
B
9
10
11
12
A
1.406 MAX.
(35.71)
B
Terminal Dimensions
.110" (2.79mm)
Quick ConnectQuick Connect
.109
(2.77)
.205" (5.21mm)
Quick Connect
.250" (6.35mm)
.034
(.86)
HEADER
.311 REF.
(7.90)
.280
(7.11)
.070 DIA.
(1.78)
.205 ± .0 02
(5.21 ± .05)
HEADER
.035
(.89)
.035
(.89)
.093
(2.36)
.156
(3.96)
.110
(2.79)
.035
.285
(.89)
(7.24)
.316 REF.
(8.03)
.032
THICKNESS
(.81)
.032
THICKNESS (.81)
.134
(3.40)
.312
(7.92)
.187” (4.75mm)
Quick Connect
HEADER
➛
.187 ± .002
(4.75 ± .05)
.250 ➛ .078
(6.35) (1.98)
➛ .281 REF.
(7.14)
.020
THICKNESS (.51)
➛
.047
(1.19)
Note: All drawings shown oversize.
➛
.237
.156
(6.02) (3.96)
.268 REF.
(6.81)
.032
THICKNESS
(.81)
➛
➛
.180
(4.57)
HEADER
.125
(3.18)
.358 REF.
(9.09)
THICKNESS .032
(0.81)
➛
➛
.093
(2.36)
.305
(7.75)
➛
.156
(3.96)
➛
Printed
Circuit
.250 ± .0 03
(6.35 ± .08)
HEADER
Wiring Diagrams
*1 Form X
1 Form C
*2 Form A
2
4
–
A
6
+
–
+4
5
7
B
A
–
B
7
A
3 Form C
*2 Form C
+6
9
–
–
+
B
1
4
7
A
–
–
+
4 Form C
3
3
1
2
3
1
6
4
5
6
5
2
6
7
8
4
9
7
8
9
9
10
11
12
B
A
B
A
B
*Recommended Load Polarity for Optimum Arc Suppression.
PC Board Layouts (Bottom Views)
1 Form X
3 Pole Models
.076 DIA. TYP.
(1.93)
4 Pole Models
.076 DIA. TYP.
(1.93)
.076 DIA. TYP.
(1.93)
.206
(5.23)
.626
(15.90)
.328
(8.33)
.328
(8.33) .626
(15.90)
.875
(22.23)
.437
(11.10)
.340
(8.64)
.875
(22.23)
Dimensions are shown for
728 reference purposes only.
Dimensions are in inches over
(millimeters) unless otherwise
specified.
.206
(5.23)
.626
(15.90)
.170
(4.32)
.510
(12.95)
1.020
(25.91)
Specifications and availability
subject to change.
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
Catalog 1308242
Issued 3-03 (PDF Rev. 9-07)
P&B
Sockets For KU Series Relays Through 3 Poles
Socket Selection Table
Stock items are boldfaced.
For KUP, KUEP, KUGP, KUIP, and KUMP relays, through 3 poles,
with .187" (4.75mm) quick connect termination.
Socket
27E043
27E046
27E067
27E121
27E305
27E396
27E893
Socket Termination
Solder eyelet
PC board, .144" (3.66mm) terminals
.187" (4.75mm) quick connect
Screw terminals
PC board, .184" (4.67mm) terminals
.187" (4.75mm) quick connect*
Screw terminals†
Hold-Down Spring
20C228 or 20C254*
20C228 or 20C254
20C228 or 20C254
20C314 (2 per socket required)
20C228 or 20C254
20C254
20C318
* 20C228 held in place by socket hold-down screw where as 20C254 snaps onto socket.
** Snap-in mounting.
† DIN rail mounting.
Note: All part numbers are RoHS compliant.
Hard Mount Sockets For Relays Through 3 Poles
1.687 ± .010
(42.85 ± .25)
Nylon sockets with .187" (4.75mm) quick
connect, solder or printed circuit terminals
are available for KUEP, KUGP, KUIP, KUMP,
and KUP relays, through 3 poles, with .187"
1.370
(4.75mm) quick connect terminals.
All are rated 15 amps and UL recognized, File (34.80)
E59244 and CSA certified File LR15734
27E043–with solder eyelet terminals.
27E067–with .187" (4.75mm) quick connect
terminals.
1.250
(31.75)
2.03
(51.56)
.875 ± .010
(22.23 ± .25)
1.50
(38.1)
27E067
27E043
.50 TYP.
(12.7)
.165 DIA.
(4.19)
2 HOLES
.297
(7.54)
.125
(3.18)
.250
(6.35)
.34 MAX.
(8.64)
1.687 ± .010
(42.85 ± .25)
.076 DIA.
(1.93)
1.370
(34.80)
1.50
(38.1)
2.03
(51.56)
1.687
(42.85)
1.076
(27.33)
.023
(.58)
.297
(7.54)
.180 TYP.
(4.57)
.156 TYP.
(3.96)
.328
(8.33)
Nylon snap-in socket with .187" (4.75mm) quick
connect terminals is available for KUEP, KUGP, KUIP,
KUMP, and KUP relays, through 3 poles, with .187"
(4.75mm) quick connect terminals. Snap-in sockets
reduce labor by eliminating time consuming screw or
rivet mounting. Preassembled wiring harnesses may
also be used as the sockets are designed to snap into
the chassis from either front or back. All are rated 15
amps and UL recognized, File E59244. The 27E396
uses chassis cutout shown on this page.
27E396–with .187" (4.75mm) quick connect
terminals.
27E046 HAS TERMINALS .144" (3.66 mm) LONG.
27E305 HAS TERMINALS .184" (4.67 mm) LONG.
Recommeded Chassis Cutout
For Snap-In Sockets
.396
(10.06)
1.395
(35.43)
1.260
(32.0 0)
1.687
(42.85)
1.270
(32.26)
.110
(2.79)
4 PLACES
.260
(6.60)
.437
(11.10)
.218
(5.54)
.090 TYP.
(2.29)
Recommended Chassis Cutout
For Hard Mount Sockets
.875
(22.23)
.875
(22.23)
.626
(15.90)
.875 ± .010 .125
(22.23 ± .25) (3.18)
.34 MAX.
(8.64)
27E396
Snap-In Socket For Relays Through 3 Poles
Suggested Socket
PC Board Layout
.50 TYP.
(12.7)
2 HOLES
.165 DIA.
(4.19)
.156 DIA.
(3.96)
.208
2 HOLES
(5.28)
Dimensions are shown for
reference purposes only.
.125
(3.18)
.250
(6.35)
.297
(7.54)
The 27E043 and 27E067 use chassis cutout shown on this page.
1.375
(34.93)
27E046, 27E305
Socket With Printed Circuit Terminals
1.250
(31.75)
1.270
(32.26)
.020
(.51)
1.375
(34.93)
1.395
(35.43)
.239
(6.07)
.065 TYP.
(1.65)
.281
(7.14)
Recommended chassis thickness
.031" (.79mm) to .062" (1.57mm).
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Specifications and availability
subject to change.
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
729
Catalog 1308242
Issued 3-03 (PDF Rev. 9-07)
P&B
Sockets For KU Series Relays Through 3 Poles (continued)
27E121
27E893
Screw Terminal Socket
Screw Terminal, Din Rail Snap-Mount Socket
(use with mounting track 24A110)
The 27E121 socket offers screw termination for KUEP, KUGP,
KUIP, KUL, KUMP and KUP relays, through 3 poles, with .187" (4.75mm)
quick connect terminals. This socket stacks on 1.700" (43.18mm) centers.
When surface mounting, two #6-32 screws of suitable length are required.
When track mounting, two 24A071 retainer clips (not shown) are required.
The 27E121 is rated 15 amps and is UL recognized, File E59244, CSA
certified, File LR15734.
The 27E893 DIN rail, snap-mount socket offers screw termination
for KUEP, KUGP, KUIP, KUL, KUMP and KUP relays, through 3 poles, with
.187" (4.75mm) quick connect terminals. This socket is constructed with a
spring-loaded latch which allows it to be quickly snapped onto or removed
from a “top hat” style mounting track. No special tools or extra hardware
is required for installation. The 27E893 is UL rated 15 amps, 94V-0, File
E59244 and CSA rated 10 amps, File LR15734.
Terminal
Location
.895 MAX.
(22.73)
1.700 ± .010
(43.18 ± .25)
.850 ± .010
(21.59 ± .25)
Terminal
Location
.315 MIN.
(8.00)
Top View
1.500
(38.10)
.156 TYP.
(3.96)
Top View
1.550
(39.37)
.540
(13.72)
6
5
4
3
2
1
1.500
(38.10)
6
5
4
3
2
1
3.000
(76.20)
.156 TYP.
(3.96)
3.150 MAX.
(80.01)
B
1.450 MAX.
(36.83)
1.900 MAX.
(48.26)
8
9
.317 TYP.
(8.04)
A
9
B
1.703
(43.26)
7
A
8
7
1.030
(26.16)
.390
(9.91)
#6-32 SCREWS &
CAPTIVE WASHERS
Sockets For KU Series 4 Pole Relays
Socket Selection Table
Stock items are boldfaced.
For 4 pole KUP relays with .110" (2.79mm) quick connect termination.
Socket
Socket Termianation
Hold-Down Spring
27E415
27E419
27E867*
.187" (4.75mm) quick connect
PC board
Screw terminals
20C228 or 20C254
20C228 or 20C254
20C254
* Use 40G432 insulator pad or customer supplied alternative.
Note: All part numbers are RoHS compliant.
.076 DIA. TYP.
(1.93)
Note: Only 4 pole KUP relays with .110" (2.79mm) quick
Screw Terminal Socket For 4 Pole Relays
.206
(5.23)
27E867 offers screw termination for 4 pole KUP relays
with .110" (2.79mm) quick connect/socket mount
terminals. Rated 10 amps and is UL recognized, File
E59244.
connect terminals can be used with 4 pole hard
mount sockets.
.328
(8.33)
.50 TYP.
(12.7)
.165 ± .0 05
(4.19 ± .13)
2 HOLES
.060 TYP.
(1.52)
1.687
(42.85)
1.370
(34.80)
2.03
(51.6)
1.250
(31.75)
.340
(8.64)
.626
(15.90)
.170
(4.32)
.510
(12.95)
1.020
(25.91)
.125
(3.18)
.297
(7.54)
.32 MAX.
(8.1)
W/QC TERMINALS
.875
(22.23)
1.50
(38.1)
Dimensions are shown for
730 reference purposes only.
.250
(6.35)
27E415 uses same chassis cutout as
27E043.
.156 DIA.
(3.96)
(2) MTNG. HOLES
5
1
2
6
3
4
8
+
++
++
++
++
++
+
+
++
.250 ± .010 #6-32 SCREWS
(6.35 ± .254)
.150 MAX.
(3.81)
9
A
10
7
11
B
12
2.750 ± .015
(69.96 ± .381)
27E415–with .187" (4.75mm) quick connect/solder terminals.
27E419–with printed circuit terminals. See PC board
layout at right.
Suggested Socket
PC Board Layout
2.250 ± .010
(57.15 ± .254)
Hard Mount Sockets For 4 Pole Relays
+
1.750 ± .010
(44.45 ± .254)
3.50 ± .030
(88.9 ± .762)
.230 ± .030
(5.84 ± .762)
.062 REF.
(1.57)
.770 MAX.
(19.56)
.461 MAX.
(11.71)
W/PC TERMINALS
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Specifications and availability
subject to change.
www.tycoelectronics.com
Technical support: