Automotive Relays
Plug-in Maxi ISO Relays
Shrouded Power Relay F7 A
■ Pin assignment similar to ISO 7588 part 1
■ Customized versions on request
– Integrated components (e.g. resistor, diode)
– Customized marking/color
– Special cover with bracket
Typical applications
Cross carline up to 70A for example: ABS control, blower fans, cooling
fan, energy management, engine control, fuel pump, heated front screen,
ignition, lamps: front, rear, fog light, main switch/supply relay, wiper control.
F136_fcw1_bw
Contact Data
Contact arrangement
1 form A, 1 NO
Rated voltage
12VDC
Limiting continuous current
23°C
70A
85°C
50A
125°C
30A
Limiting making current1) 240A
Limiting breaking current
70A
Limiting short-time current
2)
overload current, ISO 8820-3
1.35 x 50A, 1800s
2.00 x 50A, 5s
3.50 x 50A, 0.5s
6.00 x 50A, 0.1s
Jump start test, ISO 16750-1
24VDC for 5min,
conducting nominal current at 23°C
Contact material
Silver based
Min. recommended contact load3)
1A at 5VDC
Initial voltage drop at 10A,
form A (NO) contact, typ./max.
15/200mV
Frequency of operation at nominal load
6 ops./min (0.1Hz)
Operate/release time typ.
7/2ms4)
Electrical endurance
>2x105 ops.
resistive load, NO contact
50A, 14VDC
Max. DC load breaking capacity
Contact Data (continued)
>1x106 ops.
Mechanical endurance
1) The values apply to a resistive or inductive load with suitable spark suppression and
at maximum 14VDC for 12VDC or 28VDC for 24VDC load voltages. For a load current
duration of maximum 3s for a make/break ratio of 1:10.
2) Current and time are compatible with circuit protection by a typical automotive fuse.
Relay will make, carry and break the specified current.
3) See chapter Diagnostics of Relays in our Application Notes or consult the internet at
http://relays.te.com/appnotes/
4) For unsuppressed relay coil. A low resistive suppression device in parallel to the relay
coil increases the release time and reduces the lifetime caused by increased erosion
and/or higher risk of contact tack welding.
Coil Data
Rated coil voltage
12VDC
Coil versions, DC coil
Coil
Rated
Operate
Release
Coil
Rated coil
code voltage voltage voltage
resistance5) power5)
VDC VDC VDC
Ω±10% W
004 12 7.2 1.6 90 1.6
5) Without components in parallel.
All figures are given for coil without pre-energization, at ambient temperature +23°C.
Coil operating range
ECR0629-N
136J_OVR2
30
Umax
Coil voltage in V
25
20
15
Does not ta
the tempera
the contact
E = pre-ene
Uop = oper
Uop (E = 13,5 V)
10
Uop (E = 0 V)
5
0
-4 0
-2 0
0
20
40
60
80
100
120
Ambient temperature in °C
Load limit curve 1: arc extinguishes during transit time (changeover contact).
Load limit curve 2: safe shutdown, no stationary arc (make contact).
Load limit curves measured with low inductive resistors verified for 1000 switching events.
02-2017, Rev. 0217
www.te.com
© 2017 TE Connectivity.
Datasheets and product specification according to IEC 61810-1 and to be used only
together with the ‘Definitions’ section.
Does not take into account the temperature rise due to the contact current
E = pre-energization.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ section, application notes and all specifications
are subject to change.
1
Automotive Relays
Plug-in Maxi ISO Relays
Shrouded Power Relay F7 A (Continued)
Insulation Data
Initial dielectric strength
between open contacts
between contact and coil
between adjacent contacts
Load dump test
ISO 7637-1 (12VDC), test pulse 5
ISO 7637-2 (24VDC), test pulse 5
500Vrms
500Vrms
500Vrms
Vs=+86.5VDC
Vs=+200VDC
Other Data
EU RoHS/ELV compliance
compliant
Protection to heat and fire according UL94
HB or better6)
Ambient temperature
-40 to 125°C
Climatic cycling with condensation,
EN ISO 6988
6 cycles, storage 8/16h
Temperature cycling,
IEC 60068-2-14, Nb 10 cycles, -40/+85°C (5°C/min)
Damp heat cyclic,
IEC 60068-2-30, Db, Variant 1 6 cycles, upper air temp. 55°C
Damp heat constant, IEC 60068-2-3, Ca
56 days
Category of environmental protection,
IEC 61810
RT III – sealed
Degree of protection, IEC 60529
IP67 (sealed)
only with special connector
Vibration resistance (functional)
IEC 60068-2-6 (sine sweep)
10 to 500Hz, min. 10g7)
Shock resistance (functional)
IEC 60068-2-27 (half sine)
6ms, min. 30g7)
Drop test, free fall, IEC 60068-2-32
1m onto concrete
Other Data (continued)
Terminal type
Cover retention
pull force
push force
Terminal retention
pull force
push force
Weight
Packaging unit
plug-in, QC
150N
200N
150N
150N
approx. 60g (2.1oz)
108 pcs.
6) Refers to used materials.
7) No change in the switch.ing state >10μs. Valid for NC contacts, NO contact values
significantly higher.
Accessories
For fitting connectors please contact us via online Support Center
Terminal Assignment
NOR
1 form A, NO with resistor
2
2
5
1
3
02-2017, Rev. 0217
www.te.com
© 2017 TE Connectivity.
Datasheets and product specification according to IEC 61810-1 and to be used only
together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ section, application notes and all specifications
are subject to change.
Automotive Relays
Plug-in Maxi ISO Relays
Shrouded Power Relay F7 A (Continued)
0,5
6,4
3,2
4,6
0,1
0,5
Dimensions
0,5
39,6
24
54,2
TE136J_DD2
TE136_DD5
View of the terminals (bottom view)
0,5
35,2
30
6,7
10,9
TE136J_DD1
32,4
TE136J_VT1
5,5
TE136J_VT1
Product code structure
TE136_BV1
Typical product code V23136 -J
1
004 -X050
Type
V23136 Power Relay F7 A
Contact arrangement
J
1 form A, 1 NO
Cover
1
Bracket at terminal 3
Coil
004 12VDC
Terminal/arrangement
Xnnn Customized (nnn: version number)
Product code
Arrangement
V23136-J1004-X050 1 Form A, 1 NO
Cover
Standard
Coil suppr.
Resistor 560Ω
Circuit1)
NOR
Coil Contact material Terminals Part number
12VDC
Silver based
Plug-in, QC
1-1414122-0
1) See terminal assignment diagrams.
Other types on request.
This list represents the most common types and does not show all variants covered by this datasheet.
02-2017, Rev. 0217
www.te.com
© 2017 TE Connectivity.
Datasheets and product specification according to IEC 61810-1 and to be used only
together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ section, application notes and all specifications
are subject to change.
3