General Purpose
Low Power PCB Relays
SCHRACK
Power PCB Relay RT1 Inrush Power
n 1
pole 16A, 1 form A (NO) contact (AgSnO2 or W pre-make contact +
AgSnO2)
n Mono- or bistable coil
n 5kV/10mm coil-contact
n Reinforced insulation
n Test tab (manual operator) optional for bistable versions
n WG version: product in accordance to IEC60335-1
n RTS3T: Electronic ballast UL508/NEMA 410 rated
n RTS3T: 165/20ms inrush peak current
Typical applications
LED lighting systems, filament and incandescent lamp loads, movement
detectors, light sensors, intelligent wall sockets, motors (RTS3L).
Zb
Approvals
Contact Data (continued)
VDE Cert. No. 40007571,UL E214025, cCSAus 1142018
Technical data of approved types on request.
Contact Data
RT.3T
RTS3L
Contact arrangement
1 form A (NO) contact
Rated voltage
250VAC
Max. switching voltage
400VAC
Rated current
16A
Limiting continuous current
16A, UL: 20A (RTS3L)
Limiting making current,
max. 20ms (incand. lamps)
165A peak
120A peak
max. 200µs
800A peak
Breaking capacity max.
4000VA
Contact material
W (pre-make cont.)
AgSnO2
+AgSnO2
Contact style
pre-make contact single contact
Frequency of operation, with/without load
360/3600h-1
Operate/release time max., DC coil
10/5ms
Operate/Reset time max., bistable version
10/10ms
Bounce time max.
4ms
Contact ratings
Type
Contact Load
IEC 61810
RTS3L
A (NO)
20A, 250VAC resistive, 70°C
RTS3L monostable A (NO) 16A, 250VAC resistive, 85°C
RTS3T
A (NO)
16A, 250VAC resistive, 85°C
UL 61810-1 (former UL 508)
RTS3L
A (NO)
20A, 250VAC, general purpose, 70°C
RTS3L
A (NO)
16A, 250VAC, resistive, 85°C
RTS3L
A (NO)
TV8, 240VAC, 40°C
RTS3L
A (NO)
1.5hp, 240VAC, 70°C
RTS3T
A (NO)
1200W Tungsten, 120VAC/277VAC,
60Hz, 50°C
RTS3T
A (NO)
2A, 480VAC, magnetic ballast, 80°C
RTS3T
A (NO)
2A, 480VAC, electronic ballast, 80°C
RTS3T
A (NO)
3A, 277VAC, electronic ballast, 80°C
RTS3T
A (NO)
5A, 120VAC, electronic ballast, 80°C
* Special test conditions available on request
Cycles
20x103
100x103
5x103
Mechanical endurance
DC coil
bistable version
tab manually operated
RT.3T
RTS3L
>5x10 ops.
>3x106 ops.
>1x103 ops.
>10x106 ops.
>5x106 ops.
-
6
Coil Data, monostable DC coil
Coil voltage range
Operative range, IEC 61810
Coil insulation system according UL1446
5 to 110VDC
2
class F
Coil versions, monostable DC coil
Coil
Rated
Operate
Release
Coil
Rated coil
code voltage voltage voltage
resistance power
1)
VDC VDC VDC
Ω±10% mW
005 5 3.5 0.5 62 403
006 6 4.2 0.6 90 400
009 9 6.3 0.9 203 400
012 12 8.4 1.2 360 400
024 24 16.8 2.4 1440 400
048 48 33.6 4.8 5520 417
060
60
42.0
6.0
85701) 420
110 110 77.0 11.0
288001) 420
1) Coil resistance ±12%.
All figures are given for coil without pre-energization, at ambient temperature +23°C.
Other coil voltages on request.
20x103
50x103
25x103
30x103
6x103
10x103
10x103*
15x103
15x103
Coil Data, bistable coils
1 coil
2 coils
Magnetic system
polarized, bistable
Coil voltage range
3 to 24VDC
Operative range, IEC 61810
2
Limiting voltage, % of rated coil voltage 120%
150%
Min./Max. energization duration 30ms/1min at