Protective Relays
WOF & WUF Series
Product Specifications
Product Facts
n
Function 81 O/U
n
ANSI/IEEE C37.90-1978
n
UL File No. E58048
n
CSA File No. LR61158
Nominal Voltage (±20%) —
120, 230, 380 and 460 volts
Nominal Frequencies —
50, 60 and 400 Hz.
Trip Point — Screwdriver adjustable.
Adjustment range in accordance with
ordering information.
Operating Temperature —
-20°C to +65°C
Differential — The frequency pitch-up
to drop-out differential is .5% max
Voltage Drift — ± .05% maximum
frequency error for input voltage
variation of ±10%
Time Delay — See Time versus
Frequency curves
Surge Withstand Capability —
In compliance with C37.90B ANSI/IEEE
Output Contacts — One set N.O., one
set N.C.
Contact Ratings —
5 amp resistive at 120 VAC or 28VDC
R
R
2 1/ 2
5 /8
3
1 /8
4 2
1/
4
3 /
1 4
4 /
1 2
11/ 64" DIA.
4 HOLES
Note: Dimensions in inches. Multiply values by 25.4 for dimensions in mm.
Typical Curves (WOF Series)
90
Typical Curves (WUF Series)
60
Overfrequency Relay
Model WOF-12-6070
85
58 Hz. Setting
55
80
Frequency (Hz)
Frequency (Hz)
Application
The output contacts of frequency relays are energized when the frequency
exceeds the adjustable set
point. Overfrequency and
underfrequency relays are
available in 50, 60 and
400Hz. Combination
over/underfrequency “band
pass” relays are also available. These are energized
at rated frequency and deenergized during overfrequency or underfrequency
conditions. Frequency
Differential relays are energized above the preset frequency. The pick-up and
drop-out frequency settings
are independently
adjustable.
75
70 Hz. Setting
70
65 Hz. Setting
55 Hz. Setting
50
50 Hz. Setting
45
40
Underfrequency Relay
Model WUF-12-5060
35
65
62 Hz. Setting
30
0
1
60
0
1
2
3
4
5
6
2
3
4
5
6
Drop-Out Time Delay (sec)
Pick-Up Time Delay (sec)
Ordering Information
Sample Part Number 䊳
Time Delay
WUF -12 -5060 -T
Type:
WUF = Underfrequency
WOF = Overfrequency
Input Voltage (VAC)
12 = 120
23 = 230
38 = 380
46 = 460
Frequency Range
4050 = 40-50 HZ
5060 = 50-60 HZ
6070 = 60-70 HZ
3540 = 350-400 HZ
4045 = 400-450 HZ (overfrequency only)
Consult factory for additional
models.
Time Delay Options
blank = Per Time Curve
T = Adjustable
Standard Time Delay — A minimum,
fixed inverse time delay is incorporated
in all frequency relays to prevent
nuisance tripping and is represented by
the typical curves shown above.
Adjustable Time Delay —
If additional time delay is required, a
suffix “T” must be added to the part
number. This allows the minimum fixed
time delay to be field-adjustable up to
20 seconds.
Notes:
1. Remove black screws for access
to the frequency and the time
adjustments.
2. Clockwise rotation of the
frequency potentiometer will
raise the frequency trip point.
3. Clockwise rotation of the
time adjustment, option “T”
will increase the time for
overfrequency relays and dropout
time for underfrequency relays.
11–28
Catalog 5-1773450-5
Revised 3-13
www.te.com
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
Dimensions are in millimeters
unless otherwise specified.