108-32081
Product
Specification
19 DEC 18 Rev B
Quad Small Form-Factor Pluggable (QSFP) 28-Gbps Copper
Module Direct Attach Cable Assembly
1.
SCOPE
1.1.
Content
This specification defines performance, tests, and quality requirements for QSFP 28-Gbps copper
module direct attach cable assembly.
1.2.
Qualification
When tests are performed on the subject product line, procedures specified in Figure 1 shall be used.
All inspections shall be performed using the applicable inspection plan and product drawing.
2.
APPLICABLE DOCUMENTS
The following documents form a part of this specification to the extent specified herein. Unless
otherwise specified, the latest edition of the document applies. In the event of conflict between the
requirements of this specification and the product drawing, the product drawing shall take precedence.
In the event of conflict between the requirements of this specification and the referenced documents,
this specification shall take precedence.
2.1.
TE Documents
108-2286
109-197
501-60067
2.2.
QSFP Copper Module Direct Attach Cable Assembly and Cage
TE Connectivity Test Specifications vs EIA and IEC Test Methods
QSFP Copper Module Direct Attach Cable Assembly and Cage
Industry Documents
EIA-364, “Electrical Connector/Socket Test Procedures Including Environmental Classifications”
3.
REQUIREMENTS
3.1.
Design and Construction
Product shall be of the design, construction, and physical dimensions specified on the
applicable product drawing.
3.2.
Materials
Materials used in the construction of this product shall be as specified on the applicable product
drawing.
3.3.
Ratings
Voltage: 3.5 V DC (max) per SFF-8679
Current: 500 mA (max) per SFF-8679
Temperature: 0 to 70°C
3.4.
Performance and Test Description
Product is designed to meet the electrical, mechanical, and environmental performance requirements
specified in Figure 1. Unless otherwise specified, all tests shall be performed at ambient
environmental conditions.
© 2014 TE Connectivity family of companies
All Rights Reserved
| Indicates Change
This controlled document is subject to change.
For latest revision and Regional Customer Service, visit our website at www.te.com.
PRODUCT INFORMATION 1-800-522-6752
*Trademark. TE Connectivity, TE connectivity (logo), and TE (logo) are trademarks. Other logos, product, and/or company names may be trademarks of their respective owners.
1 of 3
108-32081
3.5.
Test Requirements and Procedures Summary
Test Description
Requirement
Procedure
Initial Examination of Product
Meets requirements of product
drawing and Application
Specification 114-TBD
EIA-364-18
Visual and dimensional (C of C)
inspection per product drawing.
Final Examination of Product
Meets visual requirements.
EIA-364-18
Visual inspection.
Electrical
High-Speed Test
(Sdd21, SDDXX, SCDXX,
SCCXX, SCD21-SDD21, ICN
versus IL at 12.89 GHz)
Per IEEE 802.3bj
EIA-364-108
Mechanical
Random Vibration
No discontinuities of 1 microsecond
or longer duration.
See Note.
EIA-364-28, Test Condition VII,
Condition Letter D
Subject mated specimens to 3.10-G rms
vibration between 20 to 500 Hz. Fifteen
minutes in each of 3 mutually
perpendicular planes.
Cable Flex
No discontinuities of 1 microsecond
or longer duration.
See Note.
EIA-364-41, Test Condition I
Mandrel diameter to be 7 times the
maximum cable diameter.
Axial Cable Retention
No evidence of damage or cable
pull out from connector.
EIA-364-38 Method A
Secure module and apply 140 N of axial
force to cable for 5 minutes.
Module Retention
No module damage when 90 N
extraction force is applied.
EIA-364-13
Apply 90 N to cable module with latches
enabled.
Cable Lateral Force
No discontinuities of 1 microsecond
or longer duration. Shall remain
mated.
See Note.
EIA-364-38
Apply force of 75 N [16.9 lbf] to the cable
module parallel to the test board and
perpendicular to the cage in either
direction for 10 minutes.
Cable Longitudinal Force
No discontinuities of 1 microsecond
or longer duration. Shall remain
mated.
See Note.
EIA-364-38
Apply force of 75 N [16.9 lbf] to the cable
module perpendicular to the test board
and downward for 10 minutes.
Environmental
Thermal Shock
See Note.
EIA-364-32, Test Condition VII
Subject mated specimens to 10 cycles
between -40 and +85°C
Temperature Life
See Note.
EIA-364-17, Method A.
Subject mated specimens to 85°C for
500 hours.
NOTE
Shall meet visual requirements, show no physical damage, and meet requirements of additional
tests as specified in the product qualification and re-qualification test sequence given in Figure 2.
Figure 1
Rev B
2 of 3
108-32081
3.6.Product Qualification and Re-Qualification Test Sequence
TEST GROUP (a)
TEST OR EXAMINATION
1
2
3
TEST SEQUENCE (b)
Initial Examination of Product
1
High-Speed Test
1
1
2,4,8
2,7
Cable Flex
5
Axial Cable Retention
4
3,7
Module Retention
6
Cable Lateral Force
3
Cable Longitudinal Force
4
Thermal Shock
2
5
Temperature Life
3
6
Final Examination of Product
5
9
8
(a) See paragraph 4.1.A.
(b) Numbers indicate sequence in which tests are performed.
Figure 2
4.
QUALITY ASSURANCE PROVISIONS
4.1.
Qualification Testing
A.
Specimen Selection
Specimens shall be prepared in accordance with applicable instruction sheets and shall
be selected at random from current production.
B.
Test Sequence
Qualification inspection shall be verified by testing specimens as specified in Figure 2.
4.2.
Re-Qualification Testing
If changes that significantly affecting form, fit, or function are made to the product or manufacturing
process, product assurance shall coordinate re-qualification testing consisting of all or part of the original
testing sequence as determined by development/product, quality, and reliability engineering.
4.3.
Acceptance
Acceptance is based on verification that the product meets the requirements of Figure 1. Failures
attributed to equipment, test setup, or operator deficiencies shall not disqualify the product. If product
failure occurs, corrective action shall be taken and specimens re-submitted for qualification. Testing to
confirm corrective action is required before re-submittal.
4.4.
Quality Conformance Inspection
The applicable quality inspection plan shall specify the sampling acceptable quality level to be used.
Dimensional and functional requirements shall be in accordance with the applicable product drawing
and this specification.