100E0111
Issue 4
26th May 2009
Specification Control Drawing
Page 1 of 2
Page 2 is for internal use only
WIRE, HALOGEN FREE, THIN WALL INSULATED,
300 VOLT AC, TEMPERATURE CLASSIFICATION 105°C
The complete requirements for procuring the wire described herein shall consist of this document.
Conductor Tin Plated Copper
Insulation Halogen Free
Polymer
Conductor
Nominal
Part
Cross
Conductor
Description
Sectional
Stranding
Finished Wire
Diameter
Maximum
Diameter
(mm)
Resistance
(mm)
Maximum
Weight
@
(kg/km)
Area
No./Diam.
(mm²)
(mm)
Min.
Max.
(ohms/km)
20°C
Min.
Max.
100E0111-0.50-*
100E0111-0.75-*
0.50
19/0.18
0.82
0.90
40.1
1.37
1.45
6.60
0.75
19/0.23
1.04
1.15
26.7
1.59
1.65
8.90
100E0111-1.00-*
1.00
19/0.25
1.17
1.26
20.0
1.69
1.80
10.7
100E0111-1.50-*
1.50
37/0.23
1.46
1.58
13.7
2.03
2.13
16.0
100E0111-2.50-*
2.50
37/0.29
1.85
2.01
8.21
2.50
2.63
25.7
COLOUR CODE:
The '*' in the part number shall be replaced by a standard colour code
designator in accordance with Mil Std 681.
e.g. 100E0111-1.50-0 Black outer jacket
PERFORMANCE
REQUIREMENTS:
To be tested to and meet the requirements of the issue in effect of
EN 50306-2
MARKING
REQUIREMENT:
Every 250 ± 25 mm
The mark shall be: TE Raychem EN 50306-2 300V 1 X § M
Where "§" = The nominal conductor cross-sectional area
APPROVAL:
Electronic sign off - no signatures will appear.
''Raychem', 'TE' and 'Tyco Electronics' are registered trademarks of Tyco Electronics Corporation.
©2009 Tyco Electronics Corporation. All International Rights Reserved