WIRE AND CABLE, ELECTRICAL,
INSULATED, HIGH TEMPERATURE
This amendment forms a part of Tyco Electronics/Raychem Specification 35,
Issue 2 dated February 11, 1982.
PAGE 1
Para. 3.1.1, Conductor: Change MIL-W-81044 to read "AS81044".
Para. 3.1.3, Shield: Change MIL-C-27500 to read "WC27500".
PAGE 2 and 3
Para. 4.3.2.1, 4.3.2.2, Accelerated Aging: Change MIL-W-81044 to read "AS81044" (4 places).
PAGE 3
Para. 4.3.3, Acid-Gas Generation: Delete this test in its entirety (4.3.3, 4.3.3.1, 4.3.3.2 and Figure 1) and add
new 4.3.3 as follows:
4.3.3
Aging Stability
When required by the specification sheet, the finished wire shall be conditioned in
accordance with Method 4031 of FED-STD-228 at the temperature and for the time
specified in the applicable specification sheet. Elongation and tensile strength shall be
determined in accordance with 4.3.7.
PAGE 6
Para. 4.3.11, Solder Iron Resistance: Delete and replace with the following:
“One inch (25 mm) of insulation shall be removed from each end of a 6-inch (150-mm)
sample of 20 or 22 AWG 600V finished wire. The specimen shall then be bent into a loop
and the ends tied together and weighted with a 150 ± 10 gram weight. The specimen shall
then be suspended over the solder iron having a clean 1/4-inch (6-mm) nominal diameter
bit and maintaining a bit temperature of 371 ± 10ºC. This condition shall be maintained
for 60 seconds. The specimen shall then be subjected to the Voltage Withstand Test of
4.3.12.”
© 2009 Tyco Electronics Corporation. All rights reserved.
NOTE:
ANY PRINTED COPY OF THIS DOCUMENT
IS AN UNCONTROLLED COPY.
Page 2 of 2
SPECIFICATION 35, AMENDMENT 2, ISSUE 2
PAGE 7
Para. 6.2, MIL-W-81044: Change MIL-W-81044 to read "AS81044" (2 places).
PAGE 8
Table 1, Requirements for Finished Wire and Cable: Make the following modifications:
• Acid-Gas Generation: Delete the listing for this test in its entirety.
• Immersion: Delete fluid a) “Insulating Oil (VV-I-530)”.
• Insulation Resistance: Delete this test for cable (i.e., replace “Applicable specification sheet”
with “———”), and change the Test Method from MIL-C-915 to read “MIL-W-22759”.
• Insulation Resistance: Delete this test for cable (i.e., replace “Applicable specification sheet”
with “———”), and change the Test Method from MIL-C-915 to read “AS22759”.
• Solder Iron Resistance: Change the requirement for finished wire from 60 seconds minimum to
read “No dielectric breakdown”.
• Test Methods column: Change MIL-W-81044 to read "AS81044" (3 places) and change
MIL-C-27500 to read "WC27500" (2 places).
• Add Aging Stability for finished wire as follows:
Examination or Test
Aging Stability
Requirements
Finished Wire
Cable
Applicable specification sheet
-------------------
Test Methods
Section 4.3.3