RoHS
Ready
Industrie-Steckverbinder
Heavy Duty Connectors
GLOBAL INDUSTRIAL AND COMMERCIAL
TYCO ELECTRONICS TECHNOLOGY PORTFOLIO
● Connector Systems /
Electromechanical Components
● Wire & Cable
● Resistors and Inductors
● Circuit Protection Devices
● Relays
● Heat Sinks / Thermal Management
● Touchscreens /
Interactive Displays
● Switches
● Wireless
● Identification & Labeling Products
● Antennas, GPS Antennas,
Integrated Antenna Systems
● Application Tooling
● Sensors
● Smart Cards / Leadframes
● Fiber Optic (Passive)
● Power Systems /
Electronic Modules
● Heat Shrink Tubing
● Magnetics
● Small Motors (20–1,500 W)
● Battery Assemblies
● Racks and Panels
● Clock Springs
TYCO ELECTRONICS “AT YOUR SERVICE”
Tyco Electronics Online
The Tyco Electronics Website is more than merely an
Internet guide. It is an innovative and interactive source
for application tips, product update and technical
information.
With our StepSearch-Software you can easily surf
through all of our product lines.
Internet Homepage
www.tycoelectronics.com
Electronic Internet Catalog
www.catalog.tycoelectronics.com
Product Information Center
(PIC)
You can rely on our PIC Team’s support.
Our experienced staff is an additional information
source, and the team has been particularly trained
to answer your technical questions.
To reach our PIC, please contact your local
Tyco Electronics organization.
Product and Machine Literature
For more information about Tyco Electronics and its wide range
of products we offer you a variety of literature such as product
catalogs and a lot of product specific brochures.
For catalogs and product brochures please contact your local
Tyco Electronics organization.
RoHS-Richtlinie / RoHS-Konformität
Tyco Electronics ist dafür gerüstet, die Umstellung auf RoHS-konforme Produkte bei unseren Kunden zu unterstützen. Wir haben mehr
als 1,5 Millionen Endprodukte und Bauteile auf ihre RoHS-Konformität geprüft und diese wie folgt gekennzeichnet:
RoHS-konforme Produkte:
Alle Produkte, die wir in diesem Katalog anbieten, sind RoHS-konform, sofern sie nicht anders gekennzeichnet sind. Das bedeutet, daß diese Produkte der zum 1.
Januar 2006 geänderten EU-Richtlinie 2002/95/EC entsprechen, die die Verwendung von Blei, Quecksilber, Kadmium, sechswertigem Chrom, polybromierten
Biphylenen (PBB) und polybromiertem Diphenylether (PBDE) in bestimmten elektrischen und elektronischen Produkten, die ab 1. Juli 2006 innerhalb der EU verkauft werden, verbietet.
Bitte beachten Sie, daß die Definition „RoHS-konform“ sich ebenso auf Produkte bezieht, die außerhalb des Geltungsbereiches der RoHS-Richtlinie liegen, z. B.
Handwerkzeuge und anderes nicht-elektrisches Zubehör.
Nicht-RoHS-konforme Produkte:
Nicht-RoHS-konforme Produkte sind mit einem Rautesymbol ♦ gekennzeichnet und entsprechen nicht der EU-Richtlinie 2002/95/EC.
Ausnahmen („5 of 6 Compliant“):
Ausnahmen sind mit einem Kreissymbol ● gekennzeichnet. Die so gekennzeichneten Produkte stimmen nicht vollständig mit der EU-Richtlinie 2002/95/EC überein, da sie zwar Blei, aber keinen der anderen oben genannten Gefahrstoffe oberhalb der zulässigen Grenzwerte an Lötschnittstellen enthalten. Jedoch können
diese Produkte in RoHS-konformen Anwendungen eingesetzt werden, bei denen es eine anwendungsbezogene Ausnahmeregelung im Bezug auf bleihaltige
Lötprozesse wie z. B. bei Servern, Speicherung und Netzwerkinfrastruktur gibt.
Bitte beachten Sie, daß diese Informationen zur RoHS-Konformität auf umfassenden Lieferantenbefragungen basieren und unseren aktuellen Wissensstand basierend auf diesen Lieferantenauskünften darstellen. Änderungen sind vorbehalten. Bitte besuchen sie unsere unten aufgeführte Website zur Abfrage des aktuellen
RoHS-Status.
Unser Service:
Unser kompetenter On-line RoHS-Kundenservice bietet unseren Kunden Unterstützung bei RoHS-Fragen sowie der Umsetzung der RoHS-Anforderungen sowie folgende Serviceleistungen an:
– Cross-Referenzlisten – Nicht-konforme Produkte/konforme Ersatztypen
– On-line Suchfunktion zur Abfrage des RoHS-Status unserer Produkte:
http://ecommas.tycoelectronics.com/commerce/alt/RohsAltHome.do
– Unsere Website www.tycoelectronics.com/leadfree bietet Ihnen zudem Zugriff auf technische Informationen und weitere Einzelheiten zum Thema RoHS.
Bei Fragen kontaktieren Sie bitte unser Product Information Center unter:
Telefon: +49 (0) 6251 133 – 1999
Telefax: +49 (0) 6251 133 – 1988
E-mail: Germany-PIC@tycoelectronics.com
Restriction on the use of Hazardous Substances (RoHS)
At Tyco Electronics, we’re ready to support your RoHS requirements. We’ve assessed more than 1.5 million end items/components for RoHS compliance, and issued new part numbers where any change was required to eliminate the restricted materials. Part numbers in this catalog are identified as:
RoHS Compliant -- Part numbers in this catalog are RoHS Compliant, unless marked otherwise. These products comply with European Union Directive 2002/95/EC
as amended 1 January 2006 that restricts the use of lead, mercury, cadmium, hexavalent chromium, PBB, and PBDE in certain electrical and electronic products
sold into the EU as of 1 July 2006.
NOTE: For purposes of this Catalog, included within the definition of RoHS Compliant are products that are clearly “Out of Scope” of the RoHS Directive such as
hand tools and other non-electrical accessories.
Non-RoHS Compliant -- These part numbers are identified with a “♦” symbol. These products do not comply with the material restrictions of the European Union
Directive 2002/95/EC.
5 of 6 Compliant – A “●” symbol identifies these part numbers. These products do not fully comply with the European Union Directive 2002/95/EC because they
contain lead in solderable interfaces (they do not contain any of the other five restricted substances above allowable limits). However, these products may be suitable for use in RoHS applications where there is an application-based exception for lead in solders, such as the server, storage, or networking infrastructure
exemption.
NOTE: Information regarding RoHS compliance is provided based on reasonable inquiry of our
suppliers and represents our current actual knowledge based on the information provided by our suppliers. This information is subject to change. For latest compliance status, refer to our website referenced below.
Getting the Information You Need
Our comprehensive on-line RoHS Customer Support Center provides a forum to answer your questions and support your RoHS needs. A RoHS FAQ (Frequently
Asked Questions) is available with links to more detailed information. You can also submit RoHS questions and receive a response within 24 hours during a normal work week. The Support Center also provides:
– Cross-Reference from Non-compliant to Compliant Products
– Ability to browse RoHS Compliant Products in our on-line catalog
– Downloadable Technical Data Customer Information Presentation
– More detailed information regarding the definitions used above
So whatever your questions when it comes to RoHS, we’ve got the
answers at www.tycoelectronics.com/leadfree
HTS Industrie Steckverbinder
HTS Heavy Duty Connectors
Inhalt/Contents
Seite/Page
Produkt-Übersicht/Product overview
Technische Hinweise/Technical information
Anschlussarten/Termination types
Crimpkontakte und Werkzeuge/Crimp contacts and tools
Kontakteinsätze/Contact inserts
Gehäuse-Serien/Housing series
HA.3, HA.4, HE-Q.5, HD.7, HN.D.7
4 – 09
10 – 27
28 – 31
32 – 44
Baugrösse/Size
HA.3, HD.7, EMV.3/4, HIP-K.3/4
1
1
45 – 48
49 – 54
HG-Q, HG-Q.EMV
Q
Q
55
56 – 58
HA.10, HD.15
2
2
60 – 62
63 – 65
HB.6, HB-KF.6, HD.16, EMV-K.6/16, HIP-K.6/16
3
3
66 – 72
73 – 80
HB.10, HB-KF.10, HD.24, EMV-K.10/24, HIP-K.10/24
4
4
81 – 86
87 – 99
HA.16, HD.25
5
5
100 – 102
103 – 105
HB.16, HB-KF.16, HD.40, EMV-K.16/40, HIP-K.16/40
6
6
106 – 114
115 – 126
HA.32, HD.50
7
7
127 – 129
130 – 131
HG-Q 4+2, HG-Q 8, HG-Q 10
HA.10, HD.15, HN.D.15
HE.6, HEE.10, HVT.8, HD.16, HN.2D.24, HSK 4+2
HE.10, HEE.18, HVT.14, HD.24, HN.2D.42, HMX 8/24
HA.16, HD.25, HN.D.25
HSB.6/35, HE.16, HEE.32, HVT.23, HD.40,
HN.D.40, HSK.6+36, HN.2D.72, HMX 6/12,
HMX 12/2, HMX 4/0, HMX 4/1
HA.32, HD.50, HN.D.50
HSS.8+2, HMX.4/8, HE.24, HEE.46, HVT.35,
HVT.48, HD.64, HN.D.64, HN.2D.108
8
132 – 138
HB.24, HB-KF.24, HD.64, HD-KF.64, HD.108,
EMV-K.24/64, EMV-KF/K.64, HI-KP.24/64, HIP-KF.24/64
8
139 – 151
HA.48
9
9
152
153 – 154
HB.32
10
10
155 – 159
160 – 165
HA.64
11
11
166
167
HB.48
12
12
168 – 171
172 – 174
HA.48
HSB.12/35, HE.32, HD.80, HN.D.80, HN.2D.144
HA.64
HE.48, HD.128, HN.D.128, HN.2D.216, HEE 92
HF-Serie/HF series
Schuko-Serie/Schuko series
Quick-In-System/Quick-In-System
Schirmzubehör/Accessories for braided/shielded applications
Schutzhauben/Cover
Adapterbleche/Adapter plates
Kabelverschraubungen/Cable fittings
Modul System MDL/Module System MDL
Modul System HVS/Module System HVS
Bestellnummern mit Seitenangabe/Ordering Numbers with pages
175 – 176
177
178
181 – 183
184 – 185
186 – 187
188 – 193
194 – 203
204 – 213
214 – 228
Verbindlich für Toleranzen der Abmessungen und technische Werte sind ausschließlich die neuesten Tyco Electronics Kundenzeichnungen bzw. Produkt-Spezifikationen, die Sie auf Anfrage erhalten.
Fettdruck = ab Lager/bold = on stock
All specifications subject to change. Consult Tyco Electronics for latest design specifications.
HTS Industrie Steckverbinder
HTS Heavy Duty Connectors
Gehäuse
Serie
HA
Kontakteinsätze
HB
HD
HIP-K EMV-K
HF
HG Q
Merkmale Schmale
Breite
Hohe Druckdicht Störspann- Störspann- Kunststoff
Standard Standard Standard Korrosions ungssicher ungssicher
Serie
Serie
Serie
geschützt Druckdicht Druckdicht
Korrosions
geschützt
Features
thin
standard
Series
wide
standard
series
High
pressure EMC Dense EMC Dense plastic
and
standard
tight
and
Series Corrosion pressure pressure
tight
protected
tight
Corrosion Corrosion
protected protected
IP
44 - 65
65
65
68
68
68
65
Verriegelung
Locking
system
VS
LB
VS
LB
ZB
VS
LB
ZB
SV
SV
SV
LB
Baugröße
Seite
Seite
Seite
Seite
Seite
1
49–50
51–52
53–54
53–54
Seite
Weitere
Normen
HD
HN.D
400V
16A
500V
16A
250V
10A
250V
10A
3
3
3
3
Crimp /
Screw /
Spring
Crimp
Crimp
(stamped)
Crimp
DIN VDE DIN VDE DIN VDE DIN VDE DIN VDE
0627
0627
0627
0627
0627
EN 61984 EN 61985 EN 61986 EN 61984 EN 61984
DIN EN
DIN EN
175.301- 175.301801
801
Baugröße Pole Seite Pole Seite Pole Seite Pole Seite Pole Seite
3/4 45
5
7/8 48 7/8 47
46
Q
2
63–65
HEE
3
Anschluss- Crimp/
art
Screw/
Type of
Spring
terminals
1
66–68
63–65
Verschmut
zungsgrad
Degree of
pollution
HE
10
60
15
62
3
73–78
73–78
79–80
79–80
3
6
66
10
67
16
69
4
87–90
87–97
98–99
98–99
4
10
81
18
82
24
84
5
103–105
6
7
9
12
7
139–149
149
150–151 150–151
176
49
167
11
176
12
32 107
32 127
61
40 110 40 109
50 129 50 128
24 132
46 133
64 136 64 135
48 152
10
160–165
15
25 102 25 101
16 106
8
9
153–154
172–174
16
6
130–131
10
11
5
103–105
114–124 115–124 125–126 125–126
8
4
Seite
HA
Elektr.
250V
Kennwerte
10A
nach VDE (size 1)
Last/Signal
16A
Rating
according
VDE
Power/
signal
VS = 2 Verschlussbüge /2 lever locking
LB = 1 Längsbügel/1 locking lever
ZB = 1 Zentralbügel/1 central locking
SV = 2 Schrauben/2 Screws
Q
2
Serie
32 155
80 158 80 157
48 168
92 170 128 170 128 169
64 166
Verbindlich für Toleranzen der Abmessungen und technische Werte sind ausschließlich die neuesten Tyco Electronics Kundenzeichnungen bzw. Produkt-Spezifikationen, die Sie auf Anfrage erhalten.
Fettdruck = ab Lager/bold = on stock
All specifications subject to change. Consult Tyco Electronics for latest design specifications.
HTS Industrie Steckverbinder
HSK
HMX
12/2
HTS Heavy Duty Connectors
HMX
6/12
HSS
HMX
HN.2D
HVT
HSB
250V
10A
400V
16A
400V
35A
3
3
3
3
3
3
3
3
3
Crimp
Crimp
Screw
Crimp
Crimp
Crimp
Crimp
Crimp
Screw
(HE-K)
HS-K
HMX
8/24
HF 8
HGHF 13 HG-Q8 Q4+2 HG-Q10
1000V
250A
3000V
350A
3
3
3
Crimp
Crimp
Crimp
690V/
500V/
690V/
600V/
500V/
400V/
690V
250V
250V
400V
400V
400V
250V
400V
40A/10A 40A/10A 40A/10A 63A/16A 80A/16A 40A/16A 16A/10A
500V
16A
690V
40A
400V
20A
Crimp
Crimp
Crimp
ISO
ISO
DIN VDE
DIN VDE DIN VDE DIN VDE DIN VDE DIN VDE DIN VDE DIN VDE DIN VDE DIN VDE DIN VDE DIN VDE DIN VDE
0627
0627
0627
0627
0627
0627
0627
0627
0627
0627
0627
23570-3 23570-3
0627
0627
EN 61986
EN 61986 EN 61986 EN 61986 EN 61986 EN 61986 EN 61986 EN 61986 EN 61986 EN 61986 EN 61986 EN 61986 EN 61986
Pole Seite Pole Seite Pole Seite Pole Seite Pole Seite Pole Seite Pole Seite Pole Seite Pole Seite Pole Seite Pole Seite Pole Seite Pole Seite Pole Seite Pole Seite
8
24
71
8
68
42
85
14
83
6
114 6/36 111 12/2 112 6/12 112
108 135 35/48 134
144 157
4/2 55
10
55
4/2 71 8/24 85
4
72 109 23 108
55
113
4/2 113
8/2 137 4/8 137
4
175
4
175
12 156
216 169
Verbindlich für Toleranzen der Abmessungen und technische Werte sind ausschließlich die neuesten Tyco Electronics Kundenzeichnungen bzw. Produkt-Spezifikationen, die Sie auf Anfrage erhalten.
Fettdruck = ab Lager/bold = on stock
All specifications subject to change. Consult Tyco Electronics for latest design specifications.
5
HTS Industrie Steckverbinder
HTS Heavy Duty Connectors
Gehäuse
Kontakteinsätze
HD
HIP-K
EMV-K
HF
Serie
HB
Merkmale
Breite
Standard
Serie
Hohe
Druckdicht Störspann- StörspannStandard Korrosionsg ungssicher ungssicher
Serie
eschützt Druckdicht Druckdicht
Korrosionsg
eschützt
Features
wide
standard
series
High
standard
Series
IP
Verriegelung
Locking
system
65
VS
LB
ZB
65
VS
LB
ZB
Rahmen
Frame
68
SV
SV
68
SV
VS = 2 Verschlussbüge /2 lever locking
LB = 1 Längsbügel/1 locking lever
ZB = 1 Zentralbügel/1 central locking
SV = 2 Schrauben/2 Screws
6
Baugröße
Seite
Seite
Seite
Seite
3
73–78
73–78
78–80
78–80
72 + 201
4
87–90
87–97
98–99
98–99
86 + 201
6
114–124
115–124
125–126
125–126
114 + 202
8
139–149
149
150–151
150–151
10
160–165
12
172–174
Seite
176
MDL.
1+2
MDL.
2+2
MDL.
3+4
Elektr. 1000V/250V 1000V/250V 1000V/250V
Kennwerte 150A/10A 63A/10A
40A/10A
nach VDE
Last/Signal
Rating
according
VDE
Power/
signal
pressure EMC Dense EMC Dense
tight
and
and
Corrosion pressure
pressure
protected
tight
tight
Corrosion Corrosion
protected protected
68
Serie
MDL.
8
400V
16A
Polzahl
Poles
1+
2
2+
2
3+
4
8
Verschmutzungsgrad
Degree of
pollution
3
3
3
3
Anschlussart
Type of terminals
Crimp
Crimp
Crimp
Crimp
Weitere
Normen
DIN VDE
0627
EN 61986
DIN VDE
0627
EN 61986
DIN VDE
0627
EN 61984
DIN EN
175.301801
DIN VDE
0627
EN 61985
Seite
194
194
195
195
Seite
138 + 202
159 + 203
176
171 + 203
Verbindlich für Toleranzen der Abmessungen und technische Werte sind ausschließlich die neuesten Tyco Electronics Kundenzeichnungen bzw. Produkt-Spezifikationen, die Sie auf Anfrage erhalten.
Fettdruck = ab Lager/bold = on stock
All specifications subject to change. Consult Tyco Electronics for latest design specifications.
HTS Industrie Steckverbinder
MDL.
HD.18
250V
10A
HTS Heavy Duty Connectors
MDL.
MDL. Dynamic Dynamic
HN.D.15 HN.D.18 D-2800 D-3800
MDL.
TX.4
MDL.
E.TWIN
MDL.
KX
VT
coax
MDL.2.
AIR.Sti
MDL.
RJ45
400V
10A
400V
10A
250V
5A
600V
8A
150V
16A
Twisted
pair
150V
16A
RG 58
RG 59
75 Ohm
Inner/Outer
diam.
0,8/6,1
1,44/10
2,8/10,7
10 bar
Cat5e
18
15
18
30
12
4
4
6
1
2
1
Plug/Jack
3
3
3
3
3
3
3
3
3
3
Crimp
(stamped)
Melting
(fiber)
Crimp
Crimp
Crimp
Crimp
Crimp
Crimp
Crimp
solder
push
IDC
Patch cable
198
199
200
199
Fiber optic
DIN VDE DIN VDE DIN VDE DIN VDE
0627
0627
0627
0627
EN 61986 EN 61986 EN 61985 EN 61986
196
196
196
197
MDL.2
MDL.E.C
Blindmodul Erdmodul
Crimp
DIN VDE DIN VDE
0627
0627
EN 61986 EN 61986
197
198
198
200
200
Verbindlich für Toleranzen der Abmessungen und technische Werte sind ausschließlich die neuesten Tyco Electronics Kundenzeichnungen bzw. Produkt-Spezifikationen, die Sie auf Anfrage erhalten.
Fettdruck = ab Lager/bold = on stock
All specifications subject to change. Consult Tyco Electronics for latest design specifications.
7
HTS Industrie Steckverbinder
HTS Heavy Duty Connectors
Gehäuse
Kontakteinsätze
HD
HIP-K
EMV-K
HF
Serie
HB
Merkmale
Breite
Standard
Serie
Hohe
Druckdicht Störspann- StörspannStandard Korrosionsg ungssicher ungssicher
Serie
eschützt Druckdicht Druckdicht
Korrosionsg
eschützt
Features
wide
standard
series
High
standard
Series
IP
Verriegelung
Locking
system
65
VS
LB
ZB
65
VS
LB
ZB
Rahmen
Frame
68
SV
SV
68
SV
VS = 2 Verschlussbüge /2 lever locking
LB = 1 Längsbügel/1 locking lever
ZB = 1 Zentralbügel/1 central locking
SV = 2 Schrauben/2 Screws
8
Baugröße
Seite
Seite
Seite
Seite
3
73–78
73–78
78–80
78–80
72 + 211
4
87–90
87–97
98–99
98–99
86 + 211
6
114–124
115–124
125–126
125–126
114 + 212
8
139–149
149
150–151
150–151
10
160–165
12
172–174
Seite
176
HSS.2
HSK.2
HSK.3 HE 5 SC
500V/63A 1000V/40A 690V/40A
Elektr.
Kennwerte
nach VDE
Last/Signal
Rating
according
VDE
Power/
signal
pressure EMC Dense EMC Dense
tight
and
and
Corrosion pressure
pressure
protected
tight
tight
Corrosion Corrosion
protected protected
68
Serie
400V/16A
Polzahl
Poles
2
2
3
5
Verschmutzungsgrad
Degree of
pollution
3
3
3
3
Anschlussart
Type of terminals
Crimp
Crimp
Crimp
Spring
Clamp
Weitere
Normen
DIN VDE
0627
EN 61986
DIN VDE
0627
EN 61987
DIN VDE
0627
EN 61988
DIN VDE
0627
EN 61989
Seite
204
204
205
205
Seite
138 + 212
176
Verbindlich für Toleranzen der Abmessungen und technische Werte sind ausschließlich die neuesten Tyco Electronics Kundenzeichnungen bzw. Produkt-Spezifikationen, die Sie auf Anfrage erhalten.
Fettdruck = ab Lager/bold = on stock
All specifications subject to change. Consult Tyco Electronics for latest design specifications.
HTS Industrie Steckverbinder
HTS Heavy Duty Connectors
TX
HN.D
TX
S20DF
TX.MVB
HN.D
50V/5A
50V/10A
50V/5A
50V/10A
50V/5A
10 Bar
17
25
2x4
2x8
4
8
2
3
3
3
3
3
3
3
Crimp
Crimp
Crimp
Crimp
Crimp
Crimp
Crimp
Crimp
DIN VDE
0627
EN 61991
DIN VDE
0627
EN 61992
DIN VDE
0627
EN 61993
DIN VDE
0627
EN 61994
DIN VDE
0627
EN 61995
DIN VDE
0627
EN 61996
DIN VDE
0627
EN 61997
DIN VDE
0627
EN 61998
DIN VDE
0627
EN 61999
206
207
207
208
209
209
209
210
210
HE 6
HE 8
HE 20 HN.D 12 HN.D 17 S20.DF25
500V/16A
400V/16A
500V/16A
250V/10A
250V/10A
6
20
18
12
3
3
3
Crimp
Crimp
DIN VDE
0627
EN 61990
206
TX.MVB
S20DF Pneumatik Blindmodul
210
211
Verbindlich für Toleranzen der Abmessungen und technische Werte sind ausschließlich die neuesten Tyco Electronics Kundenzeichnungen bzw. Produkt-Spezifikationen, die Sie auf Anfrage erhalten.
Fettdruck = ab Lager/bold = on stock
All specifications subject to change. Consult Tyco Electronics for latest design specifications.
9
HTS Industrie Steckverbinder
HTS Heavy Duty Connectors
Steckverbinder Bauteilkomponenten/Connector components
Kabel-Verschraubung
Spezial-Kabelverschraubungen für
Schutzarten bis IP 68 und für EMVAnwendung lieferbar
10
TDS21M
Cable fitting
Special cable fittings for protection up to
IP 68 and for electro-magnetic compatibility available
Gehäuse-Oberteil
Standard- und korrosionsgeschützte
Stecker Gehäuse
• in niedriger oder hoher Bauform
• 4 unterschiedliche Verriegelungssysteme
• unterschiedliche Kabeleingänge:
Panzergewinde (PG)
metrische Gewinde (M)
NPT-Gewinde (NPT)
Hood
Standard and corrosion-resistant
connector hoods:
• low and high construction
• 4 different locking systems
• different cable entries:
PG Thread
M Thread
NPT Thread
Kontakte
Silber- oder Goldoberfläche
Gedrehte Massivkontakte mit Schraub,
Feder oder Crimp-Anschluss
Contacts
Silver or gold plated
Solid machined contacts with screw,
spring or crimp termination
Stift-Einsatz
Schraub-, Spring Clamp-, oder CrimpAnschluss
Male insert
Screw, Spring clamp or crimp terminal
Buchsen-Einsatz
Schraub-, Spring Clamp-, oder CrimpAnschluss
Female insert
Screw, Spring clamp or crimp terminal
Gehäuse-Unterteil
Standard- und korrosionsgeschützte
Anbau-, Sockel-, und KupplungsGehäuse
• Niedrige oder hohe Bauform der
Sockel- und Kupplungs-Gehäuse,
ohne/mit komplett montiertem
Aludeckel
• 4 unterschiedliche Verriegelungssysteme
Hood and housing
Standard and corrosion-resistant
bottom-entry, surface-mounted and
cable-to-cable hoods:
• low and high construction (bottomentry and cable-to-cable hood)
with/without aluminium cover
• 4 different locking systems
Verbindlich für Toleranzen der Abmessungen und technische Werte sind ausschließlich die neuesten Tyco Electronics Kundenzeichnungen bzw. Produkt-Spezifikationen, die Sie auf Anfrage erhalten.
Fettdruck = ab Lager/bold = on stock
All specifications subject to change. Consult Tyco Electronics for latest design specifications.
HTS Industrie Steckverbinder
Approvals/Zulassungen
Series
HTS Heavy Duty Connectors
VDE
SEV
UL
File E28476
CSA
File 81776
HA 3/4
•
•
•
•
HA 10/16
•
•
•
•
°
= in Vorbereitung/in process
HB 6-24
HE Q5
HE 6-24
•
°
°
•
HEE 10-46
HD/HN.D 7
•
•
HN.D 8
•
•
HD/HN.D 15/25
•
•
•
•
HD 16/24
HD/HN.D 40-64
•
•
•
•
•
•
•
•
HVT 8-23+48
•
•
HVT 35
•
•
°
°
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
°
°
•
°
°
°
°
°
°
°
°
°
°
°
°
°
•
°
°
°
°
°
°
°
°
°
°
°
°
°
°
°
°
MDL HD 15 & MDL HD 18
MDL Air Pneumatic
MDL Twinax
MDL Koax
MDL HVT 8
HVS
HSK 6/36
HMX 4/2; HMX 4/0
HMX 8/24
HMX 6/12
HMX 4/8
HMX 12/2
HSK 4/2
HF13
HF8
HMX 8/24
HG-Q8
HG-Q4+2
HG-Q10
•
°
•
HN.2D 24-108
HSB 6
HSS 8
MDL 1+2
MDL 3+4
MDL 2+2
MDL HN.D 15 & MDL HN.D 18
Germanischer
Lloyd
°
•
•
°
•
Einsätze
Inserts
°
°
°
°
°
°
°
°
HA 3/4
HA
Quick in Adapter
HB
HM.10
HD
HIP-K
EMV-K
HF
HG Q
Gehäuse
Housings
•
Application
Specification
Product
Specification
114-74010
114-74056
114-74009
114-74003
114-74008
108-74008
108-74055
108-74007
108-18215
108-74004
108-74005
108-18215
108-74064
108-74004
108-74005
108-18215
114-74003
114-74008
114-74003
114-74000
114-74015
114-74000
114-74015
114-74000
114-74015
114-74000
114-74000
114-74015
114-74026
114-74013
114-74026
114-74013
114-74007
114-74028
114-74031
114-74036
114-74000
114-74015
114-74014
114-74020
114-74044
114-74033
114-74034
114-74013
°
114-74062
114-74058
114-74061
114-74051
114-74067
114-74068
114-74063
114-74025
114-74043
114-74061
114-74050
114-74055
114-74062
114-74065
114-74002
114-74010
114-74001
114-74004
114-74024
114-74001
114-74004
114-74001
114-74004
114-74035
114-74036
114-74064
114-74065
108-74002
108-74018
108-74002
108-74018
108-74002
108-74002
108-74018
108-74035
108-74035
108-74012
108-74006
108-74016
108-74024
108-74017
108-74031
108-74032
108-74033
108-74013
108-74034
°
108-74058
108-74060
108-74051
108-74065
108-74066
108-74061
108-74044
108-74044
108-74050
108-74053
108-74000
108-74009
108-74026
108-74001
108-74003
108-74014
108-74027
108-74041
108-74001
108-74003
108-74027
108-74030
108-74036
108-74052
Verbindlich für Toleranzen der Abmessungen und technische Werte sind ausschließlich die neuesten Tyco Electronics Kundenzeichnungen bzw. Produkt-Spezifikationen, die Sie auf Anfrage erhalten.
Fettdruck = ab Lager/bold = on stock
All specifications subject to change. Consult Tyco Electronics for latest design specifications.
11
HTS Industrie Steckverbinder
HTS Heavy Duty Connectors
Schutzarten von elektrischen Betriebsmitteln
Elektrische Betriebsmittel müssen aus Sicherheitsgründen gegen Einflüsse von außen geschützt werden. Diese Aufgabe übernehmen
Gehäuse, die das elektrische Betriebsmittel gegen Berührung, das Eindringen von festen Fremdkörpern, Staub, Feuchtigkeit oder Wasser
schützen. Die Norm IEC 529 mit dem Titel „Schutzarten durch Gehäuse (IP-Code)“ bildet die Grundlage für die Bestimmung und
Kennzeichnung der Schutzart eines Gehäuses
Der Umfang der Schutzes (Schutzart) durch ein Gehäuse wird mittels genormter Prüfverfahren nachgewiesen. Zur Einteilung verschiedener Gehäuse bezüglich ihrer Schutzart wird ein Bezeichnungssystem verwendet. Das Bezeichnungssystem besteht aus den CodeBuchstaben IP und zwei nachfolgenden Kennziffern.
Anordnung des IP – Code (International bzw. Ingress Protection)
IP
5
6
Code Buchstabe
Kennziffer 1
Kennziffer 2
Die erste Kennziffer gibt den Berührungs- und Fremdkörperschutz, die zweite den Schutz des Gehäuses gegen das Eindringen von
Wasser an. Die folgende Tabelle enthalten Kurzbeschreibung sowie Definitionen der einzelnen Kennziffern des IP-Codes.
Bedeutung der ersten Kennziffer
Die erste Kennziffer gibt an, inwieweit das Gehäuse Personenschutz gewährleistet. Dieser Schutz wird erreicht, indem das Eindringen
eines Körperteils (oder eines Gegenstandes der von einer Person gehalten wird) in das Gehäuse verhindert wird.
Gleichzeitig gewährt das Gehäuse dem Betriebsmittel Schutz gegen das Eindringen von festen Fremdkörpern.
Dies ist der Grund dafür, dass es zu jeder ersten Kennziffer 2 Beschreibungen und 2 Definitionen gibt.
Erste
Kennziffer
Schutzgrad gegen Zugang zu gefährlichen Teilen und gegen feste Fremdkörper
Kurzbeschreibung
0
Nicht geschützt
1
-Geschützt gegen feste Fremdkörper mit Ø 50mm
-Geschützt gegen den Zugang zu gefährlichen Teilen
mit dem Handrücken.
Kugel mit Ø 50mm darf nicht voll eindringen
-Geschützt gegen feste Fremdkörper 12,5 mm
Durchmesser
-Geschützt gegen den Zugang zu gefährlichen Teilen
mit einem Finger
Prüffinger mit Ø 12mm muss ausreichend Abstand von
gefährlichen Teilen haben.
2
12
Definition
3
-Geschützt gegen feste Fremdkörper Ø 2,5mm
-Geschützt gegen den Zugang zu gefährlichen Teilen
mit einem Werkzeug
4
-Geschützt gegen feste Fremdkörper Ø 1,0mm
Durchmesser.
-Geschützt gegen den Zugang zu gefährlichen Teilen
mit einem Draht
Prüfsonde mit Ø 2,5mm Durchmesser
darf nicht eindringen.
Prüfsonde mit Ø 1mm Durchmesser
darf nicht eindringen.
5
Staubgeschützt
Eindringen von Staub wird nur soweit verhindert, dass
dieser das zufriedenstellende Arbeiten des Gerätes oder
die Sicherheit nicht beeinträchtigt.
6
Staubdicht
Kein Eindringen von Staub.
Verbindlich für Toleranzen der Abmessungen und technische Werte sind ausschließlich die neuesten Tyco Electronics Kundenzeichnungen bzw. Produkt-Spezifikationen, die Sie auf Anfrage erhalten.
Fettdruck = ab Lager/bold = on stock
All specifications subject to change. Consult Tyco Electronics for latest design specifications.
HTS Industrie Steckverbinder
HTS Heavy Duty Connectors
Bedeutung der zweiten Kennziffer
Die zweite Kennziffer gibt an, inwieweit das Gehäuse schädliche Einflüsse auf das Betriebsmittel infolge des Eindringens von Wasser
verhindert.
Zweite
Kennziffer
Schutz gegen Wasser
Kurzbeschreibung
Definition
0
Nicht geschützt
1
Geschützt gegen Tropfwasser
Senkrecht fallende Tropfen dürfen keine schädliche
Wirkung haben
2
Geschützt gegen Tropfwasser, wenn das Gehäuse bis
zu 15° geneigt ist.
Senkrecht fallende Tropfen dürfen keine schädliche
Wirkung haben, wenn das Gehäuse um einen Winkel bis
zu 15° beiderseits der Senkrechten geneigt ist.
3
Geschützt gegen Sprühwasser.
Wasser, das in einem Winkel bis zu 60° beiderseits der
Senkrechten gesprüht wird, darf keine schädliche
Wirkung haben.
4
Geschützt gegen Spritzwasser.
Wasser, das aus jeder Richtung gegen das Gehäuse
spritzt, darf keine schädliche Wirkung haben.
4K
Geschützt gegen Spritzwasser mit erhöhtem Druck.
Wasser, das aus jeder Richtung mit erhöhtem Druck
gegen das Gehäuse spritzt, darf keine schädliche Wirkung
haben. (gilt nach DIN 40 050 Teil 9 nur für
Straßenfahrzeuge)
5
Geschützt gegen Strahlwasser.
Wasser, das aus jeder Richtung als Strahl gegen das
Gehäuse spritzt, darf keine schädliche Wirkung haben.
6
Geschützt gegen starkes Strahlwasser.
Wasser, das aus jeder Richtung als starker Strahl gegen
das Gehäuse spritzt, darf keine schädliche Wirkung
haben.
6K
Geschützt gegen starkes Strahlwasser mit erhöhtem
Druck.
Wasser, das aus jeder Richtung als Strahl mit erhöhtem
Druck gegen das Gehäuse gerichtet ist, darf keine schädliche Wirkung haben. (gilt nach DIN 40050 Teil 9 nur für
Straßenfahrzeuge)
7
Geschützt gegen die Wirkung beim zweitweiligen
Untertauchen in Wasser.
Wasser darf nicht in einer Menge eintreten, die schädliche
Wirkung verursacht, wenn das Gehäuse unter genormten
Druck- und Zeitbedingungen zeitweilig in Wasser untergetaucht ist
8
Geschützt gegen die Wirkung beim dauernden
Untertauchen in Wasser.
Wasser darf nicht in einer Menge eintreten, die schädliche
Wirkung verursacht, wenn das Gehäuse dauernd unter
Wasser getaucht ist unter Bedingungen, die zwischen
Hersteller und Anwender vereinbart werden müssen. Die
Bedingungen müssen jedoch schwieriger sein als für die
Kennziffer 7.
9K
Geschützt gegen Wasser bei Hochdruck-/Dampfstrahlreinigung.
Wasser, das aus jeder Richtung unter stark erhöhtem
Druck gegen das Gehäuse gerichtet ist, darf keine schädliche Wirkung haben. (gilt nach DIN 40 050 Teil 9 nur für
Straßenfahrzeuge)
Verbindlich für Toleranzen der Abmessungen und technische Werte sind ausschließlich die neuesten Tyco Electronics Kundenzeichnungen bzw. Produkt-Spezifikationen, die Sie auf Anfrage erhalten.
Fettdruck = ab Lager/bold = on stock
All specifications subject to change. Consult Tyco Electronics for latest design specifications.
13
HTS Industrie Steckverbinder
HTS Heavy Duty Connectors
Isolationskoordination für elektrische Betriebsmittel in Niederspannungsanlagen
Bemessung der Luft- und Kriechstrecken nach DIN EN60664-1. (Die folgenden Seiten stellen lediglich einen Auszug der Norm dar und
zeigen nicht den vollständigen Inhalt)
Isolationskoordination
Isolationskoordination umfasst die Auslegung der elektrischen Isolation eines Betriebsmittels hinsichtlich dessen Anwendung und
Umgebung.
Dies geschieht einerseits durch Auslegung der Luftstrecken (Basis ist dabei die zu erwartende Überspannung), andererseits durch
Auslegung der Kriechstrecken (Basis sind dafür die Betriebsspannungen sowie die Isolierstoffeigenschaften). Weiter werden isolationseigenschaft-verändernde Bedingungen berücksichtigt (Verschmutzung, Schutzmaßnahmen gegen Verschmutzung, Luftdruck, thermische
oder chemische Beeinflussung ).
Luftstrecken werden nach der äußeren oder inneren zu erwartenden Überspannungen bemessen. Die 4 Überspannungsklassen (Überspannungskategorien I bis IV) berücksichtigen die unterschiedliche Verwendung eines Betriebsmittels. Die für die jeweilige
Nennspannung des Versorgungsnetzes unterschiedliche Bemessungs-Stoßspannungen ist hierbei die Grundlage.
Je nach Homogenitätsgrad des Feldes zwischen den Elektroden (Fall A – inhomogenes Feld, Fall B – homogenes Feld) können die
Luftstrecken aus Tabelle 2a (Mindestluftstrecken) bestimmt werden; Industiesteckverbinder werden immer nach dem „Fall A“ ausgelegt
Der Einfluss durch Verschmutzung wird bei der Festlegung von Luft- und Kriechstrecken durch vier Schärfegrade (Verschmutzungsgrad
1 bis 4) berücksichtigt.
Grundlage der Kriechstrecken ist die aus der Betriebsspannung abgeleitete Bemessungsspannung.
Die Mindestkriechstrecken sind in Tabelle 4 den Bemessungsspannungen je nach Verschmutzungsgrad zugeordnet.
Enthalten die Produktbeschreibungen keine zusätzlichen Angaben, sind die in diesem Katalog aufgeführten Produkte nach dieser
Bestimmung (DIN EN60664-1) für Überspannungskategorie III und Verschmutzungsgrad 3 bemessen.
Überspannungskategorie I bis IV
• Betriebsmittel der Überspannungskategorie I sind Waren zum Anschluss an die feste elektrische Installation eines Gebäudes. Es ist
entweder in der festen Installation oder zwischen der festen Installation und dem Gerät, Maßnahmen zur Begrenzung der transienten
Überspannungen getroffen worden.
• Betriebsmittel der Überspannungskategorie II sind energieverbrauchende Betriebsmittel, die von der festen Installation gespeist werden.
Anmerkung: z. B. Haushaltsgeräte, tragbare Werkzeuge und andere Hausgeräte sowie ähnliche Verbraucher.
• Betriebsmittel der Überspannungskategorie III sind Bestandteil der festen Installation. Es sind Betriebsmittel, bei denen ein höherer
Grad der Verfügbarkeit erwartet wird.
Anmerkung: Beispiele für solche Geräte sind z.B. Industriesteckverbinder, Verteilertafeln, Leistungsschalter, Verteilungen, Schalter,
Steckdosen).
• Geräte der Überspannungskategorie IV sind für den Einsatz am Anschlusspunkt der Installation bestimmt.
Anmerkung: Beispiele für solche Geräte sind Elektrizitätszähler, Überstromschutzschalter und Rundsteuergeräte.
Verschmutzungsgrad 1 bis 4
In DIN EN60664-1 sind die Verschmutzungsgrade wie folgt definiert:
Verschmutzungsgrad 1:
Es tritt keine oder nur trockene, nicht leitfähige Verschmutzung auf. Die Verschmutzung hat keinen Einfluss.
Verschmutzungsgrad 2:
Es tritt nur nichtleitfähige Verschmutzung auf. Gelegentlich muss mit vorübergehender Leitfähigkeit durch Betauung gerechnet werden.
Verschmutzungsgrad 3:
Es tritt leitfähige Verschmutzung auf oder trockene, nichtleitfähige Verschmutzung, die leitfähig wird, da Betauung zu erwarten ist.
Verschmutzungsgrad 4:
Es tritt eine dauernde Leitfähigkeit auf, hervorgerufen durch leitfähigen Staub, Regen oder Nässe.
Isolierstoff
Die Isolierstoffe werden entsprechend ihren Vergleichszahlen der Kriechwegbildung (Comparativ Tracking Index) CTI in folgende vier
Gruppen eingeteilt:
Isolierstoff I:
600 ) CTI
Isolierstoff II:
400 ) CTI < 600
Isolierstoff III a:
175 ) CTI < 400
14
Verbindlich für Toleranzen der Abmessungen und technische Werte sind ausschließlich die neuesten Tyco Electronics Kundenzeichnungen bzw. Produkt-Spezifikationen, die Sie auf Anfrage erhalten.
Fettdruck = ab Lager/bold = on stock
All specifications subject to change. Consult Tyco Electronics for latest design specifications.
HTS Industrie Steckverbinder
HTS Heavy Duty Connectors
Bemessung der Luftstrecken
Schema zur Ermittlung der Luftstrecken
Nennspannung der
Stromversorgung
Bemessungs-Stoßspannung
Bemessungs-Stoßspannung
nach Tabelle 1
Mindestluftstrecke L
nach Tabelle 2 a
Höhe
> 2000 m
NN
Überspannungskategorie
i.d.R.. III
Verschmutzungsgrad
i.d.R. 3, jedoch darf lt. EN 61984
eine Klasse kleiner gewählt werden,
wenn das Gehäuse min. die
Schutzart min. IP 54 aufweist.
L mit Höhenkorrekturfaktor nach
Tabelle 2 b multiplizieren
Luftstrecke L
in mm
Bemessungs-Stoßspannung für Betriebsmittel (Tabelle 1)
Nennspannung des
Bemessungs-Stoßspannung in kV (1,2/50ms) für
Stromversorgungssystems *) in V
Dreiphasige Systeme Einphasige Systeme Betriebsmittel an der Betriebsmittel als Teil Betriebsmittel zum
Besonders
der festen Installation
Anschluss an die
geschützte
im Mittelpunkt
Einspeisung der
Installation
(Überspannungsfeste Installation
Betriebsmittel
(ÜberspannungsKategorie lll)
(Überspannungs(ÜberspannungsKategorie ll)
Kategorie l)
Kategorie lV)
120 bis 240
4
2,5
1,5
0,8
4
2,5
1,5
230/400**
6
277/480**
400/690**
8
6
4
2,5
8
6
4
1000
12
*) ausgewählte Spannungswerte
**) der / Strich bzeichnet ein Dreiphasen-Leitersystem. Der tiefere Wert ist die Spannung Leiter zu Neutralleiter, wärend der höhere Wert
die Spannung Leiter zu Leiter ist
Verbindlich für Toleranzen der Abmessungen und technische Werte sind ausschließlich die neuesten Tyco Electronics Kundenzeichnungen bzw. Produkt-Spezifikationen, die Sie auf Anfrage erhalten.
Fettdruck = ab Lager/bold = on stock
All specifications subject to change. Consult Tyco Electronics for latest design specifications.
15
HTS Industrie Steckverbinder
Erforderliche
StehStoßspannung
1) [kV]
0,33 _)
0,40
0,5 _)
0,60
0,80 _)
1,0
1,2
1,5 _)
2,0
2,5 _)
3,0
4,0 _)
5,0
6,0 _)
8,0 _)
10
12 _)
15
20
25
30
40
50
60
80
100
1
[mm]
0,01
0,02
0,04
0,06
0,10
0,15
0,25
0,5
1,0
1,5
2
3
4
5,5
8
11
14
18
25
33
40
60
75
90
130
170
HTS Heavy Duty Connectors
Mindestluftstrecken für die Isolationskoordination (Tabelle 2 a)
Fall A
Fall B
(inhomogenes Feld)
(homogenes Feld)
Verschmutzungsgrad
Verschmutzungsgrad
2
3
4
1
2
3
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
_)
0,2
0,80
1,6
0,25
0,5
1,0
1,5
2
3
4
5,5
8
11
14
18
25
33
40
60
75
90
130
170
1,0
1,5
2
3
4
5,5
8
11
14
18
25
33
40
60
75
90
130
170
2
3
4
5,5
8
11
14
18
25
33
40
60
75
90
130
170
0,01
0,02
0,04
0,06
0,10
0,15
0,2
0,3
0,45
0,6
0,8
1,2
1,5
2
3
3,5
4,5
5,5
8
10
12,5
17
22
27
35
45
4
[mm]
_)
0,2
0,8
1,6
0,3
0,5
0,6
0,8
1,2
1,5
2
3
3,5
4,5
5,5
8
10
12,5
17
22
27
35
45
1,2
1,5
2
3
3,5
4,5
5,5
8
10
12,5
17
22
27
35
45
2
3
3,5
4,5
5,5
8
10
12,5
17
22
27
35
45
1)Die Spannung ist
- für Funktionsisolierung: die höchste an der Luftstrecke zu erwartende Stoßspannung;
- für Basisisolierung, falls direkt oder wesentlich beeinflußt durch transiente Überspannung aus dem Niederspannungsnetz:
die Bemessungs-Stoßspannung des Betriebsmittels;
- für andere Basisisolierung: die höchste Stoßspannung, die im Stromkreis auftreten kann;
_) Vorzugswerte
Höhen-Korrekturfaktoren (Tabelle 2 b)
Höhe in m
2000
3000
4000
5000
6000
7000
8000
9000
10000
15000
20000
16
Normaler Luftdruck in kPa
80,0
70,0
62,0
54,0
47,0
41,0
35,5
30,5
26,5
12,0
5,5
Multiplikationsfaktor für Abstände
1,00
1,14
1,29
1,48
1,70
1,95
2,25
2,62
3,02
6,67
14,50
Verbindlich für Toleranzen der Abmessungen und technische Werte sind ausschließlich die neuesten Tyco Electronics Kundenzeichnungen bzw. Produkt-Spezifikationen, die Sie auf Anfrage erhalten.
Fettdruck = ab Lager/bold = on stock
All specifications subject to change. Consult Tyco Electronics for latest design specifications.
HTS Industrie Steckverbinder
HTS Heavy Duty Connectors
Bemessung der Kriechstrecke
Vereinfachtes Schema zur Ermittlung der Kriechstrecke
Netz-Nennspannung der
Stromversorgung (Tabelle 3)
Bemessungsspannung
Isolierstoffgruppe
i.d.R.: Klasse III
Mindestkriechstrecke
nach Tabelle 4
Verschmutzungsgrad
i.d.R. 3, jedoch darf lt. EN 61984
eine Klasse kleiner gewählt werden,
wenn das Gehäuse min. die
Schutzart min. IP 54 aufweist.
Kriechstrecke K
in mm
Verbindlich für Toleranzen der Abmessungen und technische Werte sind ausschließlich die neuesten Tyco Electronics Kundenzeichnungen bzw. Produkt-Spezifikationen, die Sie auf Anfrage erhalten.
Fettdruck = ab Lager/bold = on stock
All specifications subject to change. Consult Tyco Electronics for latest design specifications.
17
HTS Industrie Steckverbinder
HTS Heavy Duty Connectors
Netz-Nennspannung der Stromversorgung*
Bemessungsspannung
[V]
[V]
60
63
110/120/127
125
160
150
208
200
220/230/240
250
320
300
380/400/415
400
500
440
480/500
500
575
630
630
600
660/690
630
800
720/830
960
1000
1000
1000
Tabelle 3
* die Auswahl stellt nicht den vollständigen Zusammenhang zwischen allen möglichen weltweit verwendeten Netzformen und der
Bemessungsspannung dar
Mindestkriechstrecke für Betriebsmittel mit langzeitiger Spannungsbeanspruchung
Verschmutzungsgrad
Bemessungs
Spannung
[V]
10
12,5
16
20
25
32
40
50
63
80
100
125
160
200
250
320
400
500
630
800
1000
1
I)
0,08
0,09
0,10
0,110
0,125
0,140
0,16
0,18
0,20
0,22
0,25
0,28
0,32
0,42
0,56
0,75
1,00
1,30
1,8
2,4
3,2
l
0,40
0,42
0,45
0,48
0,50
0,53
0,56
0,60
0,63
0,67
0,71
0,75
0,80
1,00
1,25
1,60
2,00
2,50
3,2
4,0
5,0
2
Isolierstoffgruppe
ll
0,40
0,42
0,45
0,48
0,50
0,53
0,80
0,85
0,90
0,95
1,00
1,05
1,1
1,4
1,8
2,2
2,8
3,6
4,5
5,6
7,1
lll
0,40
0,42
0,45
0,48
0,50
0,53
1,10
1,20
1,25
1,3
1,4
1,5
1,6
2,0
2,5
3,2
4,0
5,0
6,3
8,0
10,0
l
1,00
1,05
1,10
1,20
1,25
1,30
1,4
1,5
1,6
1,7
1,8
1,9
2,0
2,5
3,2
4,0
5,0
6,3
8,0
10,0
12,5
3
Isolierstoffgruppe
ll
1,00
1,05
1,10
1,20
1,25
1,30
1,6
1,7
1,8
1,9
2,0
2,1
2,2
2,8
3,6
4,5
5,6
7,1
9
11
14
lll
1,00
1,05
1,10
1,20
1,25
1,30
1,8
1,9
2,0
2,1
2,2
2,4
2,5
3,2
4,0
5,0
6,3
8,0
10,0
12,5
16,0
l
1,6
1,6
1,6
1,6
1,7
1,8
1,9
2,0
2,1
2,2
2,4
2,5
3,2
4,0
5,0
6,3
8,0
10,0
12,5
16,0
20,0
4
Isolierstoffgruppe
ll
1,6
1,6
1,6
1,6
1,7
1,8
2,4
2,5
2,6
2,8
3,0
3,2
4,0
5,0
6,3
8,0
10,0
12,5
16
20
25
lll
1,6
1,6
1,6
1,6
1,7
1,8
3,0
3,2
3,4
3,6
3,8
4,0
5,0
6,3
8,0
10,0
12,5
16,0
20
25
32
Tabelle 4
18
Verbindlich für Toleranzen der Abmessungen und technische Werte sind ausschließlich die neuesten Tyco Electronics Kundenzeichnungen bzw. Produkt-Spezifikationen, die Sie auf Anfrage erhalten.
Fettdruck = ab Lager/bold = on stock
All specifications subject to change. Consult Tyco Electronics for latest design specifications.
HTS Industrie Steckverbinder
HTS Heavy Duty Connectors
Degree of protection provided by enclosures
For safety reasons, electrical equipment needs to be protected against outside influences. The basis for the determination is the standard IEC 529 titled ‘Degree of protection provided by enclosures (IP – Code)'.
Using a standardized test procedure the extent of the protection class is verified. To classify different housings according to their protection class, a designation system is used which consists of the code – letters 'IP' and two code numbers.
Arrangement of the IP – Code (International bzw. Ingress Protection)
IP
5
6
Code Letter
1st characteristic numeral
2nd characteristic numeral
Meaning of the 1st characteristic numeral
The first numeral describes the protection of the housing against intrusion of foreign bodies as well as the protection of people against
dangerous parts or influences. Because of this, there are two descriptions and definitions for each of the first code letter.
1st
numeral
Protection against solid obects and against access to hazardous parts
short description
definition
0
no protection
1
-protection against solid foreign bodies of Ø 50mm
-protection against access to hazardous parts with
the back of a hand
A sphere of Ø 50mm, must not intrude
-protection against solid foreign bodies of Ø 12 mm
-protection against access to hazardous parts with
the finger
A sphere of Ø 12mm diameter, must not intrude
-protection against solid foreign bodies of 2,5 mm
diameter and bigger
-protection against access to hazardous parts with a
tool
A sphere of Ø 2,5mm diameter, must not intrude
2
3
5
-protection against solid foreign bodies of 1,0 mm
diameter and bigger
-protection against access to hazardous parts
with a wire
protected against dust
6
dust proof
4
The probe, sphere of Ø 1,0mm, must not intrude
The infiltration of dust is not completely prevented, but it
does not infiltrate to such an extent that the operation or
the safety of the device is affected.
No infiltration of dust
Verbindlich für Toleranzen der Abmessungen und technische Werte sind ausschließlich die neuesten Tyco Electronics Kundenzeichnungen bzw. Produkt-Spezifikationen, die Sie auf Anfrage erhalten.
Fettdruck = ab Lager/bold = on stock
All specifications subject to change. Consult Tyco Electronics for latest design specifications.
19
HTS Industrie Steckverbinder
HTS Heavy Duty Connectors
Meaning of the 2nd characteristic numeral
The second numeral describes the protection of the housing against the intrusion of water with harmful effects.
second
code digit
Protection degrees against the intrusion of water, designated by the second code digit
short description
20
definition
0
not protected
1
protected against dripping water
Vertically falling drops shall have not harmful effects.
2
protected against dripping water when the housing is
at an angle of up to 15°
Vertically falling drops shall have not harmful effects
when the enclosure is tiled upto 15°
3
protected against water spray
Water sprayed at an angle up to 60°, shall have no harmful effects
4
protected against splash water
Water splashed against the enclosure from any direction
shall have no harmful effects
4K
protected against splash water with increased
pressure
Water splashed against the enclosure with increased
pressure from any direction shall have no harmful effects
(Applies acc to DIN 40050 - 9 only for road vehicles)
5
protected against jets of water
water splashes against the enclosure from any direction
as a water jet shall have no harmful effects
6
protected against strong jets of water
water splashes against the enclosure from any direction
as a strong water jet shall have no harmful effects
6K
protected against strong jets of water with increased
pressure
water splashes directly against the enclosure from any
direction as a strong water jet with increased pressure,
shall have no harmful effects (Applies acc to DIN 40050 9 only for road vehicles)
7
protection against the effects of temporary submersion in water
Quantity of water that ingresses an enclosure, when it is
temporarily immersed under standardized conditions of
pressure and time, shall have no harmful effects.
8
protection against the effects of continuous submersion in water
Quantity of water that ingresses an enclosure, when it is
continuously immersed under conditions of pressure and
time, shall have no harmful effects. The conditions must,
however be harder than for code digit 7 and agreed between user and producer.
9K
Protected against water during high-pressure / jetstream cleaning.
Water that is directed against the housing with greatly
increased pressure from any direction must not have any
detrimental effect (Applies acc to DIN 40050 - 9 only for
road vehicles)
Verbindlich für Toleranzen der Abmessungen und technische Werte sind ausschließlich die neuesten Tyco Electronics Kundenzeichnungen bzw. Produkt-Spezifikationen, die Sie auf Anfrage erhalten.
Fettdruck = ab Lager/bold = on stock
All specifications subject to change. Consult Tyco Electronics for latest design specifications.
HTS Industrie Steckverbinder
HTS Heavy Duty Connectors
Insulation Coordination for Electrical Connectors in Low Voltage Plants
Dimensioning of Clearance and Creeping Distances acc. to DIN EN60664-1; following pages show only a part of the standards
Insulation Coordination
Insulation coordination includes the design of the electrical insulation of a connector depending on its use and environment.
This occurs either by design of the clearance distances (basis is the expected power surge) or by design of the creeping distance (basis
is the operating voltage as well as the quality of the insulating material). Furthermore, insulation-changing conditions are taken into
account (pollution, protective measures against pollution, air pressure, thermal or chemical influences).
Air distances are measured according to the outer or inner power surge expected. The four power surge classes (power surge categories I to IV) take the different use of the connector into account.
Depending on the homogeneity of the field between the electrodes (case A – inhomogenous field, case B – homogenous field) the air
distances can be determined according to table 2a (minimum air distances); industrial connectors are always determined according to
case A.
The influence from pollution when determining the air- and creeping distances is taken into account by using four degrees of severity
(pollution degree 1 to 4).
Basis of the creeping distances is the rated voltage which is deduced from the operating voltage.
The minimum creeping distances are allocated in table 4 depending on the severity of pollution.
If the product descriptions do not contain any additional information the products listed in this catalogue were rated according to norm
DIN VDE 0110 for surge category III and severity of pollution 3.
Surge Category I to IV
• resources of surge category I are goods for the termination of fixed electrical installations of a building. Measures for the limitation of
transient surges were taken either in the fixed installation or between the fixed installation and the equipment.
• resources of surge category II are resources which use power and are fed from a fixed installation.
Note: e. g. domestic applicances, portable tools and other appliances as well as similar consumers.
• resources of surge category III are part of a fixed installation. They are resources from which a high degree of availability is
expected.
Note: Examples for such appliances are e.g. industrial connectors, distribution panels, power switches, distributors, switches, sockets).
• Devices of surge category IV are for use at the supply terminal of the installation.
Note: Examples for such appliances are electricity counters, overload cut-out switches and Rundsteuergeräte.
Pollution Degree 1 to 4
DIN VDE 0110 defines the pollution degrees as follows: :
Pollution Degree 1:
There is no or only dry, non-conductive pollution. The pollution is without influence.
Pollution Degree 2:
There is only non-conductive pollution. Occasional momentary conductivity due to condensation.
Pollution Degree 3:
There is conductive pollution or dry non-conductive pollution, which becomes conductive due to condensation.
Pollution Degree 4:
There is a continuous conductivity due to conductive dust, rain or moisture.
Insulation Material
The insulation materials are divided into the following four groups depending on their comparative tracking index (CTI) :
Insulation material I:
600 ) CTI
Insulation material II:
400 ) CTI < 600
Insulation material III a:
175 ) CTI < 400
Verbindlich für Toleranzen der Abmessungen und technische Werte sind ausschließlich die neuesten Tyco Electronics Kundenzeichnungen bzw. Produkt-Spezifikationen, die Sie auf Anfrage erhalten.
Fettdruck = ab Lager/bold = on stock
All specifications subject to change. Consult Tyco Electronics for latest design specifications.
21
HTS Industrie Steckverbinder
HTS Heavy Duty Connectors
Measurement of Clearances
Diagram for the Determination of Clearances
rated voltage
of the power supply
rated surge voltage
rated surge voltage
acc. to table 1
minimum clearance L
acc. to table 2 a
height
> 2000 m
NN
surge categories,
normally III
degree of pollution
normally 3, but acc. to EN 61984
a smaller class may be chosen
if the housing has a
protection class of IP 54
multiply L with height correction
factor acc. to table 2 b
clearance L
in mm
rated voltage
of the power supply *) in V
3-phase systems
single systems
in the centre
Rated Surge Voltage for Utilities
Rated Surge Voltage in kV (1,2/50ms) for
utilities at the feed of utilities as part of a
fixed installation
the installation
(surge category lV)
(surge category lll)
utilites for
connection to
fixed
installations
(surge category ll)
1,5
2,5
Specially
protected utilities
(surge category l)
120 up to 240
4
2,5
0,8
1,5
230/400**
6
4
277/480**
400/690**
8
6
4
2,5
4
1000
12
8
6
*) chosen voltage values
**) the / dash is for a 3-phase system with 4 lines. The lower value is for phase to neutral, the higher value is for phase to phase
22
Verbindlich für Toleranzen der Abmessungen und technische Werte sind ausschließlich die neuesten Tyco Electronics Kundenzeichnungen bzw. Produkt-Spezifikationen, die Sie auf Anfrage erhalten.
Fettdruck = ab Lager/bold = on stock
All specifications subject to change. Consult Tyco Electronics for latest design specifications.
HTS Industrie Steckverbinder
HTS Heavy Duty Connectors
minimum clearance in air at installation heights of up to 2000 m above sea leavel (NN)
case A
case B
inhomogenous field)
homogenous field)
degree of pollution
degree of pollution
1
2
3
4
1
2
3
(mm)
(mm)
(mm)
(mm)
(mm)
(mm)
(mm)
"rated surge
voltage [kV]"
0,33 _)
0,40
0,5 _)
0,60
0,80 _)
1,0
1,2
1,5 _)
2,0
2,5 _)
3,0
4,0 _)
5,0
6,0 _)
8,0 _)
10
12 _)
15
20
25
30
40
50
60
80
100
0,01
0,02
0,04
0,06
0,10
0,15
0,25
0,5
1,0
1,5
2
3
4
5,5
8
11
14
18
25
33
40
60
75
90
130
170
_)
0,2
0,80
1,6
0,25
0,5
1,0
1,5
2
3
4
5,5
8
11
14
18
25
33
40
60
75
90
130
170
1,0
1,5
2
3
4
5,5
8
11
14
18
25
33
40
60
75
90
130
170
2
3
4
5,5
8
11
14
18
25
33
40
60
75
90
130
170
0,01
0,02
0,04
0,06
0,10
0,15
0,2
0,3
0,45
0,6
0,8
1,2
1,5
2
3
3,5
4,5
5,5
8
10
12,5
17
22
27
35
45
4
(mm)
_)
0,2
0,8
1,6
0,3
0,5
0,6
0,8
1,2
1,5
2
3
3,5
4,5
5,5
8
10
12,5
17
22
27
35
45
1,2
1,5
2
3
3,5
4,5
5,5
8
10
12,5
17
22
27
35
45
2
3
3,5
4,5
5,5
8
10
12,5
17
22
27
35
45
1)This voltage is
- for functional insulation:
the maximum impulse voltage expected to occur across the clearance
- for basic insulation directly exposed by transient overvoltages
- for other basic insulation
_) Preferred values
Factors for Height Correction
height in m
2000
3000
4000
5000
6000
7000
8000
9000
10000
15000
20000
normal air pressure in kPa
80,0
70,0
62,0
54,0
47,0
41,0
35,5
30,5
26,5
12,0
5,5
multiplication factor for distances
1,00
1,14
1,29
1,48
1,70
1,95
2,25
2,62
3,02
6,67
14,50
Verbindlich für Toleranzen der Abmessungen und technische Werte sind ausschließlich die neuesten Tyco Electronics Kundenzeichnungen bzw. Produkt-Spezifikationen, die Sie auf Anfrage erhalten.
Fettdruck = ab Lager/bold = on stock
All specifications subject to change. Consult Tyco Electronics for latest design specifications.
23
HTS Industrie Steckverbinder
HTS Heavy Duty Connectors
Measurement of creepage
Diagram for the Determination of creepage
voltage of the power supply
rated surge voltage
according to table 3
Insulation Class of used material,
normally III
minimum creepage L
acc. to table 4
degree of pollution
normally 3, but acc. to EN 61984 a
smaller class may be chosen if the
housing has a protection class of IP
54.
creepage
in mm
24
Verbindlich für Toleranzen der Abmessungen und technische Werte sind ausschließlich die neuesten Tyco Electronics Kundenzeichnungen bzw. Produkt-Spezifikationen, die Sie auf Anfrage erhalten.
Fettdruck = ab Lager/bold = on stock
All specifications subject to change. Consult Tyco Electronics for latest design specifications.
HTS Industrie Steckverbinder
HTS Heavy Duty Connectors
voltage of the power supply
[V]
60
110/120/127
150
208
220/230/240
300
380/400/415
440
480/500
575
600
660/690
720/830
960
1000
Rated voltage
[V]
63
125
160
200
250
320
400
500
500
630
630
630
800
1000
1000
Table 3
* the above shown table does not give the entire correlation of word-wide used networks and rated voltages; it is reduced to the most common
ones; further details, see DIN EN60664-1
Creepages in [mm] for electrical Equipments
degree of pollution
rated
voltage
[V]
10
12,5
16
20
25
32
40
50
63
80
100
125
160
200
250
320
400
500
630
800
1000
1
All Insulater
classes
0,08
0,09
0,10
0,110
0,125
0,140
0,16
0,18
0,20
0,22
0,25
0,28
0,32
0,42
0,56
0,75
1,00
1,30
1,8
2,4
3,2
l
0,40
0,42
0,45
0,48
0,50
0,53
0,56
0,60
0,63
0,67
0,71
0,75
0,80
1,00
1,25
1,60
2,00
2,50
3,2
4,0
5,0
2
Insulation Class
ll
0,40
0,42
0,45
0,48
0,50
0,53
0,80
0,85
0,90
0,95
1,00
1,05
1,1
1,4
1,8
2,2
2,8
3,6
4,5
5,6
7,1
lll
0,40
0,42
0,45
0,48
0,50
0,53
1,10
1,20
1,25
1,3
1,4
1,5
1,6
2,0
2,5
3,2
4,0
5,0
6,3
8,0
10,0
l
1,00
1,05
1,10
1,20
1,25
1,30
1,4
1,5
1,6
1,7
1,8
1,9
2,0
2,5
3,2
4,0
5,0
6,3
8,0
10,0
12,5
3
Insulation Class
ll
1,00
1,05
1,10
1,20
1,25
1,30
1,6
1,7
1,8
1,9
2,0
2,1
2,2
2,8
3,6
4,5
5,6
7,1
9
11
14
lll
1,00
1,05
1,10
1,20
1,25
1,30
1,8
1,9
2,0
2,1
2,2
2,4
2,5
3,2
4,0
5,0
6,3
8,0
10,0
12,5
16,0
l
1,6
1,6
1,6
1,6
1,7
1,8
1,9
2,0
2,1
2,2
2,4
2,5
3,2
4,0
5,0
6,3
8,0
10,0
12,5
16,0
20,0
4
Insulation Class
ll
lll
1,6
1,6
1,6
1,6
1,6
1,6
1,6
1,6
1,7
1,7
1,8
1,8
2,4
3,0
2,5
3,2
2,6
3,4
2,8
3,6
3,0
3,8
3,2
4,0
4,0
5,0
5,0
6,3
6,3
8,0
8,0
10,0
10,0
12,5
12,5
16,0
16
20
20
25
25
32
Table 4
Verbindlich für Toleranzen der Abmessungen und technische Werte sind ausschließlich die neuesten Tyco Electronics Kundenzeichnungen bzw. Produkt-Spezifikationen, die Sie auf Anfrage erhalten.
Fettdruck = ab Lager/bold = on stock
All specifications subject to change. Consult Tyco Electronics for latest design specifications.
25
HTS Industrie Steckverbinder
HTS Heavy Duty Connectors
Technische Kennwerte Serie HF/Technical specifications Series: HF
Crimphülse
• Optimale Materialanpassung entsprechend der Kundenapplikation
• Anpassung auf spezielle
Leiterquerschnitte und
Verarbeitungswerkzeuge
• Verwendung der gleichen Crimphülse
für Stift-, Buchsen- und Erdkontakt
• Robuste widerstandsfähige Crimphülse
für vielfältige Industrieapplikationen
➊ Stiftkontakt
➋ Kontaktträger
➌ Adapter
➍ Crimphülse
Stift-/ Buchsenkontakt
• Verschleißarmes Basismaterial
• Austausch der Einzelteile durch modularen Aufbau
• Oberflächenveredlung gemäß
Kundenapplikationsforderung
• Reduzierung der Steck-/Ziehkräfte um
30%
• Erhöhung der Steckzyklen um 50%
• Variable Anschlußtechnik
➍
➌
➋
➊
Rated current
350 A
Bemessungsspannung 1000 V~, Isolationsgruppe C
Rated voltage
1000V~, insulation group C
Prüfspannung
3 (C)
Test voltage
3 (C)
Prüfspannung Ueff
3 kV
Test voltage Urms
3 kV
Volume resistance
) 1 m1
Bemessungsstrom
350 A
Durchgangswiderstand ) 1 m1
Isolationswiderstand
* 10101
Insulation resistance
* 10101
Temperaturbereich
- 40°C + 125°C
Die obere Grenztemperatur schließt die
Kontakterwärmung und Erwärmung
durch Umgebungstemperatur ein
Temperature range
- 40°C + 125°C
The maximal limit temperature
includes contact heat-up and heat-up
caused by ambient temperature.
Kabel Anschluß
Crimpanschluß 50 - 150 mm2
Wire termination
Crimp terminal 50 - 150 mm2
Materials
Werkstoffe
26
Crimp ferrule
• Optimum material adaptation according
to customer’s application
• Adaptation to special customer wire
size and crimping tools
• Same crimp ferrule for male, female
and grounding contact
• Robust crimp ferrule for toughindustrial
applications
➊ Male contact
➋ Insulating material plastic
➌ Adapter
➍ Crimp ferrule
Male/female contact
• Wear-resistant basic material
• Worn parts can be individually exchanged
• Surface coating according to customer
application
• 30% reducted mating and pulling forces
• 50% increase of making cycles
• Variable wire termination
Kontakteinsätze
thermoplastischer Formstoff
glasfaserverstärkt (UL-gelistet) V-0
Contact inserts
thermoplastic material
glass-fibre reinforced (UL listed) V-O
Kontaktelemente
Kupferlegierung
Contact elements
copper alloy
Kontaktoberfläche
hartversilbert
Contact surfaces
hard-silver-plated
Kontaktzahlen/
No. of contacts
8
14
23
35
48
Baugröße/
Size
3
4
6
8
8
Verbindlich für Toleranzen der Abmessungen und technische Werte sind ausschließlich die neuesten Tyco Electronics Kundenzeichnungen bzw. Produkt-Spezifikationen, die Sie auf Anfrage erhalten.
Fettdruck = ab Lager/bold = on stock
All specifications subject to change. Consult Tyco Electronics for latest design specifications.
HTS Industrie Steckverbinder
HTS Heavy Duty Connectors
Technische Kennwerte Serie MDL/Technical specifications series MDL
• Modular aufgebaute Kontakteinsätze Baugröße 3-4-6-8-10-12
• Optimale Flexibilität, leichtes Handling,
schnelle Montage
• Rationelle Mischbestückung zur Lösung
anwenderspezifischer Kundenanforderungen
• Halterahmen zur Aufnahme der variabel
einsetzbaren Module, baugleich für Oberund Unterteil
• Reduzierung der Lagerbestandskosten
• Polarisierter Einsatz der Module in einem
Halterahmen
• Leistungs- und Signalübertragung über
einen Steckverbinder
• Voreilende Schutzkontakte
• Elektromagnetisch verträgliche Module für
Bussystem-Schnittstellen
Vorschriften
DIN VDE 0110 für Luft- und Kriechstrecken
DIN VDE 0627 für Steckverbinder und
Steckvorrichtungen
Zulassungen
UL, CSA
Modulbaustein
• Modular contact inserts –
sizes 3-4-6-8-10-12
• Optimum flexibility, easy handling, quick
assembly
• Rational mixing of connectors, i. e. application specific customer requirements
can be solved
• Fixing frame to hold the interchangeable
modules, same design for upper and
lower part
• Storage costs are reduced
• Polarized use of the modules in a fixing
frame
• Power- and signal transmission with one
connector
• Leading grounding contact
• Modules, tolerant to electro-magnetic
waves, for bus system interfaces
Regulations
DIN VDE 0110 for clearance and
tracking distance
DIN VDE 0627 for connectors, plugs
and sockets
Approvals
UL, CSA
Module element
Verschmutzungsgrad 3
Werkstoff
thermoplastischer Formstoff
Temperaturbereich
- 40°C + 125°C
Brennbarkeit
nach UL 94 V-0
Degree of contamination 3
Material
thermoplastics
Temperature range
- 40°C + 125°C
Flammable
acc. to UL 94 V-0
Modulbausteine
Module elements
Modulbezeichnung
Moduldesignation
Elektrische Kennwerte/Pneumatic
Electrical ratings/Pneumatic
Kontaktzahlen
No. of contacts
Last/Signal/Power Signal
MDL-HF 1+2
1 x (150A/1000V), 2 x (10A/250V)
3
Last/Signal/Power Signal
MDL-HSS 2+2
2 x (63A/1000V), 2 x (10A/250V)
4
Last/Signal/Power Signal
MDL-HSM 3 + 4
3 x (40A/1000V), 4 x (10A/250V)
7
Pneumatik/Pneumatic
MDL-AIR
10 bar, NW = 4,0
2
Signal/Signal
MDL-HN.D
15 x (10A/400V)
15, 18
Signal/Signal
MDL-HD
18 x (10A/250V)
15, 18
LWL/Optical transmission
MDL-LWL
Signal/Signal
MDL-HVT
8 x (16A/400V)
8
Signal/Signal
MDL-Twinax
4 x (16A/150V)
4
Signal/Signal
MDL-KX
6x RG 58/RG 59
6
Signal/Signal
MDL-KX.VT
Signal/Signal
MDL-Dynamic
30 x (5A/600V)
Signal/Signal
MDL-RJ45
CAT 5e
18
1
30
1
Verbindlich für Toleranzen der Abmessungen und technische Werte sind ausschließlich die neuesten Tyco Electronics Kundenzeichnungen bzw. Produkt-Spezifikationen, die Sie auf Anfrage erhalten.
Fettdruck = ab Lager/bold = on stock
All specifications subject to change. Consult Tyco Electronics for latest design specifications.
27
HTS Industrie Steckverbinder
HTS Heavy Duty Connectors
Anschlussarten/Termination types
• Schraubanschluss
Screw connection
• Spring Clamp-Anschluss
Spring Clamp connection
• Crimpanschluss
Crimp connection
Schraubanschluss/Screw terminal
Schraubanschluss
Der Schraubanschluss ist die bekannteste Anschlussart. Ihre Bemessung
erfolgt nach VDE 0609. Anzugs- und
Prüfdrehmomente entnehmen Sie bitte
nebenstehender Tabelle.
Leiterquerschnitt (mm2)
Schraubengewinde
Prüfdrehmoment Ncm
Screw terminal
The screw terminal is the most common type of connection. Ratings are
based on VDE 0609. Please refer to the
table at the left for torques.
1
1,5
2,5
M 2,6 M 3
M3
40
50
4
6
M 3,5 M 4
50
80
120
Das Diagramm zeigt den Streubereich der
Ausziehkräfte der Leiter aus der
Schraubver-bindung eines
Kontaktelementes mit Klemmschutz.
Klemmschraube: M 3
Prüfdrehmoment: 50 Ncm
10
Wire cross section (mm2)
M4
Thread
120
Test torque Ncm
The diagram shows the force range for
pulling the conductor out of the screwed
connection of a contact element with wire
protection.
Clamp screw: M 3
Test torque: 50 Ncm
mit Drahtschutz/with wire protection
Die einschlägigen Bestimmungen sagen
aus:
• Serien HE, HSB-Klemmen
mit Drahtschutz:
Ausser dem Abisolieren ist kein besonderes Herrichten der Leiterenden erforderlich.
The relevant regulations stipulate:
• Terminals of series HE, HSB
with wire protection:
No special preparation of wire ends
required except for stripping.
Kontakt-Einsätze
max. Leiterquerschnitt
Abisolierlänge
Contact inserts
max. wire cross section
Stripping length
mm2
AWG
HA.3/HA.4
2,5
14
4,5
HE.6-48/HA.10-64
2,5
14
7,0
HSB.6/35
6,0
10
11,5
I (mm)
L
28
Verbindlich für Toleranzen der Abmessungen und technische Werte sind ausschließlich die neuesten Tyco Electronics Kundenzeichnungen bzw. Produkt-Spezifikationen, die Sie auf Anfrage erhalten.
Fettdruck = ab Lager/bold = on stock
All specifications subject to change. Consult Tyco Electronics for latest design specifications.
HTS Industrie Steckverbinder
HTS Heavy Duty Connectors
HA Spring Clamp-Anschluss/HA Spring Clamp connection
Technische Kennwerte
Vorschriften:
DIN VDE 0110
DIN VDE 0627
Zulassungen:
UL/CSA/SEV/VDE
Käfigzugfederanschluß:
bis 2,5mm2 (AWG 14)
mit Aderendhülse bis 1,5mm2 (AWG 16)
Werkstoffe
Kontaktelemente:
Kontaktoberfläche:
Kupferlegierung
hartversilbert
Kontaktanordnung
Ansicht Anschlußseite
Contact arrangements
view from terminal side
Materials
Contact elements:
Contact surface:
8 7 6 5 4 3 2 1
6 7 8 9 10
16 15 14 13 12 11 10 9
Montageausschnitt für Kontakteinsätze bei Verwendung ohne Gehäuse
Panel cut-out
A
M3
up to 2,5mm2 (AWG 14)
with wire pin up to 1,5mm2 AWG 16)
24
Cage clamp terminal:
1 2 3 4 5
10
Approval:
DIN VDE 0110
DIN VDE 0627
UL/CSA/SEV/VDE
16
Technical ratings
Specification:
3
B
Baugröße/Size
copper alloy
hard-silver-plated
Maße/Dimensions
A
B
43,5
49,5
60
66
2
5
A
C
12
30
22.3*
27
12
M3x10
M3x10
B
D
*Abstand für sichere Kontaktgabe 24 mm
Baugröße/Size
2
5
A
56,5
73
Maße/Dimensions
B
C
49,5
22,8
66
22,8
D
16
16
Verbindlich für Toleranzen der Abmessungen und technische Werte sind ausschließlich die neuesten Tyco Electronics Kundenzeichnungen bzw. Produkt-Spezifikationen, die Sie auf Anfrage erhalten.
Fettdruck = ab Lager/bold = on stock
All specifications subject to change. Consult Tyco Electronics for latest design specifications.
29
HTS Industrie Steckverbinder
HTS Heavy Duty Connectors
HE Spring Clamp-Anschluss/HE Spring Clamp connection
Technische Kennwerte
Vorschriften:
Zulassungen:
DIN VDE 0110
DIN VDE 0627
UL/CSA/SEV/VDE
Käfigzugfederanschluß:
bis 2,5mm2 (AWG 14)
Kontakteinsätze:
Thermoplastischer Formstoff PBT
Kontaktelemente:
Kontaktoberfläche:
Kupferlegierung
hartversilbert
Technical ratings
Specification:
Approval:
Cage clamp terminal:
Materials
Contact elements:
Contact surface:
Montageausschnitt für Kontakteinsätze
bei Verwendung ohne Gehäuse
Panel cut-out
DIN VDE 0110
DIN VDE 0627
UL/CSA/SEV/VDE
M3
36 27 20
up to 2,5mm2 (AWG 14)
with wire pin up to 1,5mm2 (AWG 16)
A
B
C
copper alloy
hard-silver-plated
Baugröße
Size
Abmessungen/Dimensions (mm)
3
A
B
C
37
44
52
4
50
57
65
6
70,5
77,5
85,5
8
97
104
112
C
A
21.2
21.2
34
22.3*
34
M3x10
M3x10
B
*Abstand für sichere Kontaktgabe 24 mm
Baugröße/Size
3
4
6
8
30
A
52
63
83,5
110
D
Maße/Dimensions
B
C
44
33
57
33
33
77,5
104
33
D
27
27
27
27
Verbindlich für Toleranzen der Abmessungen und technische Werte sind ausschließlich die neuesten Tyco Electronics Kundenzeichnungen bzw. Produkt-Spezifikationen, die Sie auf Anfrage erhalten.
Fettdruck = ab Lager/bold = on stock
All specifications subject to change. Consult Tyco Electronics for latest design specifications.
HTS Industrie Steckverbinder
HTS Heavy Duty Connectors
Crimpkontakte/Crimp contacts
Schliffbilder einer Crimpstelle
Cross sections of crimp contacts
Die moderne Crimp-Anschlußtechnik weist
gegenüber Schraub- oder Lötanschlüssen
wesentliche technische und wirtschaftliche
Vorteile auf.
Zum Crimpen werden ein- oder mehrdrähtige
Leiter eingesetzt. der Crimpvorgang kann durch
Crimp-Handzangen oder für die Serienfertigung
mit halb- oder vollautomatischen
Crimpmaschinen erfolgen. Mit Vollautomaten
geschieht das Abisolieren der Leiter und das
Crimpen der Kontakte maschinell in einem
Arbeitsgang. Mit Hilfe dieser Crimpwerkzeuge
wird der Anschlußbereich des Crimpkontaktes
verformt und somit eine feste, gasdichte
Verbindung mit dem Leiter hergestellt.
F-Crimpung für HD.M-Kontakte
F crimp for HD.M contacts
HTS bietet wirtschaftliche und technische Vorteile
mit zwei weltweit verbreiteten Crimpsystemen:
• Präzisions-gedrehte HE, HN.D, HVT, HSM, HSL
und HSS-Massiv-Crimpkontakte.
• Präzisions-gestanzte HD.M-Crimpkontakte.
Vierkant Crimpung
Square section crimping
State-of-the-Art crimping technology is superior
to screw or solder terminals compared to technical and economic perspectives.
Solid or multi strand conductors can be used
for crimping. Crimping is done with manual
crimping tools or semi-automatic crimping
machines. Fully automatic machines perform all
processes from stripping the conductor to crimping the contacts in a single step. The crimping
tools connect the contact and the conductor by
applying pressure to the connection area of the
contact, thus creating a reliable, gas-tight termination.
HTS offers technical and economic advantages
with two world-wide proven and acknowledged
crimping systems:
• precision-screw machined solid crimp
contacts HE, HN.D, HVT, HSM, HSL and HSS.
• precision-stamped HD.M crimp contacts
1. Die gleichbleibende Crimpqualität garantiert
einen konstanten Durchgangswiderstand.
2. Korrosionsfestigkeit durch annähernde
Kaltverschweißung.
3. Vorkonfektionierung von Kabelbäumen mit
Crimpkontakten.
4. Wesentlich höhere Verdrahtungsgeschwindigkeit.
5. Das Lösen bereits gesteckter Kontakte ist mit
speziellem Lösewerkzeug möglich.
1. The constant crimp quality ensures a constant resistance.
2. Connection is almost cold-welded, giving corrosion resistance to the termination.
3. Preparation of cable harness with crimp
contacts.
4. Faster termination times.
5. Crimped contacts can be removed with a
special tool.
Auswahlhilfe Silber/Goldkontakte:
Die Auswahl o.g. Materialien sollte vor folgendem
Hintergrund stattfinden:
Verschleiß ist auf Grund der Härte der Goldoberfläche bei vergoldeten Kontakten geringer,
was auch höhere Steckzyklen erlaubt. Auch ist die
Steckkraft ist bei vergoldeten Kontakten geringer.
Das Widerstandsverhalten bei Gold ist konstanter
aufgrund der geringeren Reaktionsfreudigkeit:
Silber reagiert mit Schwefel und bildet eine dünne
Oxidschicht aus. Diese Schicht wird beim Stecken
problemlos durchbrochen bzw. von größeren
Strömen „verbrannt“.
Unserer Erfahrung nach ist ein Einsatz von
Goldkontakten nur bei Signal-Stömen und -Spannungen aufgrund des sehr konstanten (zeitlich)
Widerstandsverhalten notwendig.Bei Anwendungen >5mA und >5V ist der Einsatz von
Silberkontakten aus wirtschaftlichen Gesichtspunkten sinnvoller.
In nebenstehender Grafik ist diese
Strom/Spannungs Auswahl zusammengefaßt.
Spez. Widerstand: Gold: 0,022 Vmm_/m
Silber: 0,015 Vmm_/m
How to choose between silver- or gold-plated
contacts:
The choice of either silver- or gold-plated contacts
should be made considering the following:
The surface of gold-plated contacts is harder,
which means less wear and tear and enables higher mating cycles. The mating force of gold-plated
contacts is lower as well.
Gold's resistance performance is more constant
due to its low reactivity. Silver reacts with sulphur
and forms a thin oxidation layer. When mating this
layer can be broken through or 'burnt off' by higher currents.
Our experience has shown that the use of goldplated contacts is only necessary with signal currents and voltages when very constant resistance
performance is required. From an economic point
of view it makes more sense to use silver-plated
contacts for applications of >5mA and >5V.
The graphic shown left is the current/voltage
choice.
Resistance: Gold: 0,022 Vmm_/m
Silver: 0,015 Vmm_/m
Silber Kontakt
Silver contact
5V
Gold Kontakt
Gold contact
5mA
Verbindlich für Toleranzen der Abmessungen und technische Werte sind ausschließlich die neuesten Tyco Electronics Kundenzeichnungen bzw. Produkt-Spezifikationen, die Sie auf Anfrage erhalten.
Fettdruck = ab Lager/bold = on stock
All specifications subject to change. Consult Tyco Electronics for latest design specifications.
31
HTS Industrie Steckverbinder
HTS Heavy Duty Connectors
Crimpkontakte S20DF Serie/Crimp contacts S20DF series
Bestelltext
Designation
Bezeichnung
Description
Stiftkontakt/Pin contact
Buchsenkontakt/Socket contact
5A
Bestell-Nr.
Order No.
Maße mm2
Dimensions mm2
Stiftkontakt verzinnt
Pin contact tin plated
66507-9
66506-9
0,08 – 0,2
0,2 – 0,6
Bandkontakt/Stift verzinnt
Reel contact/pin tin plated
66507-3
66506-3
0,08 – 0,2
0,2 – 0,6
Buchsenkontakt verzinnt
Socket contact tin plated
66505-9
66504-9
0,08 – 0,2
0,2 – 0,6
Bandkontakt/Buchse vezinnt
Reel contact/socket tin plated
66505-3
66504-3
0,08 – 0,2
0,2 – 0,6
Stiftkontakt vergoldet
Pin contact gold plated
1-66507-0
1-66506-0
0,08 – 0,2
0,2 – 0,6
Bandkontakt/Stift vergoldet
Reel contact/pin gold plated
66507-4
66506-4
0,08 – 0,2
0,2 – 0,6
Buchsenkontakt vergoldet
Socket contact gold plated
1-66505-0
1-66504-0
0,08 – 0,2
0,2 – 0,6
Bandkontakt/Buchse vegoldet
Reel contact/socket gold plated
66505-4
66504-4
0,08 – 0,2
0,2 – 0,6
5,15
4
14,65
Werkstoff: Kupferlegierung
Oberfläche:
- verzinnt
- vergoldet
Durchgangswiderstand: ) 3 m1
Crimpanschluss:
- mm2 0,08 - 0,6 mm2
- AWG 28 - 20
14,65
Material: Copper alloy
Finish:
- tin plated
- gold plated
Contact resistance: ) 3 m1
Crimp terminal :
- mm2 0,08 - 0,6 mm2
- AWG 28 - 20
Werkzeuge für Crimptechnik S20DF Serie/Crimping tools S20DF series
Bezeichnung
Description
Crimpzange
Crimping tool
Ausdrückwerkzeug /Extraction tool
Bestelltext
Designation
Bestell-Nr.
Order No.
Certi-Crimp
Reel-Fed Certi Lok*
169424-1
Mini Applicator
566184-0
S20DF
91285-1
Querschnitt mm2
Cross section mm2
alle Querschnitte
all cross
sections
Eindrückwerkzeug/Insertion tool
S20DF
726363-1
*für Bandkontakte/Ior reel contacts
32
Verbindlich für Toleranzen der Abmessungen und technische Werte sind ausschließlich die neuesten Tyco Electronics Kundenzeichnungen bzw. Produkt-Spezifikationen, die Sie auf Anfrage erhalten.
Fettdruck = ab Lager/bold = on stock
All specifications subject to change. Consult Tyco Electronics for latest design specifications.
HTS Industrie Steckverbinder
HTS Heavy Duty Connectors
Crimpkontakte Dynamic 2800 Serie/Crimp contacts Dynamic 2800 series
Buchsenkontakt/Receptable contact
Bestell-Nr.
Order No.
Maße mm2
Dimensions mm2
Werkzeug
Tool
Stiftkontakt vergoldet
Top contact gold plated
1318112-1
1318111-1
0,08 – 0,2 (S)
0,3 – 0,85 (M)
91576-1
91595-1
Bandkontakt/Stift vergoldet
Strip form
Top contact gold plated
1318110-1
1318109-1
0,08 – 0,2 (S)
0,3 – 0,85 (M)
(Applicator)
1385232-2
1385231-2
Buchsenkontakt vergoldet
Receptable contact gold plated
1318108-1
1318107-1
0,08 – 0,2 (S)
0,3 – 0,85 (M)
91596-1
91595-1
Bandkontakt/Buchse vergoldet
Strip form
Receptable contact gold plated
1318106-1
1318105-1
0,08 – 0,2 (S)
0,3 – 0,85 (M)
(Applicator)
1385232-2
1385232-2
Bestelltext
Designation
Bezeichnung
Description
5A
Stiftkontakt/Top contact
9,2
8,5
22,0
15,9
Werkstoff: Kupferlegierung
Oberfläche:
- vergoldet
Durchgangswiderstand: ) 3 m1
Crimpanschluss:
- mm2 0,08 - 0,85 mm2
- AWG 38 - 18
Material: Copper alloy
Finish:
- gold plated
Contact resistance: ) 3 m1
Crimp terminal :
- mm2 0,08 - 0,85 mm2
- AWG 38 - 18
Crimpkontakte Dynamic 3800 Serie/Crimp contacts Dynamic 3800 series
Buchsenkontakt/Receptable contact
Maße mm2
Dimensions mm2
Werkzeug
Tool
Stiftkontakt vergoldet
Top contact gold plated
175287-2
175288-2
175289-2
987512-2
0,06 – 0,2 (S)
0,2 – 0,5 (M)
0,5 – 1,25 (L)
1,25 – 2,2 (2L)
91565-1
91559-1
91558-1
91560-1
Bandkontakt/Stift vergoldet
Strip form
Top contact gold plated
175284-2
175285-2
175286-2
917485-2
0,06 – 0,2 (S)
0,2 – 0,5 (M)
0,5 – 1,25 (L)
1,25 – 2,2 (2L)
(Applicator)
1276659-1
937472-1
1385001-2
1276662-1
Buchsenkontakt vergoldet
Seceptable contact gold plated
175216-2
175217-2
175218-2
917511-2
0,06 – 0,2 (S)
0,2 – 0,5 (M)
0,5 – 1,25 (L)
1,25 – 2,2 (2L)
91565-1
91559-1
91558-1
91560-1
Bandkontakt/Buchse vergoldet
Strip form
Receptable contact gold plated
175194-2
175195-2
175196-2
917484-2
0,06 – 0,2 (S)
0,2 – 0,5 (M)
0,5 – 1,25 (L)
1,25 – 2,2 (2L)
(Applicator)
1276659-1
937472-1
1385001-2
1276662-1
Stiftkontakt/Top contact
9,3
25,8
18,3
12,1
Werkstoff: Kupferlegierung
Oberfläche:
- vergoldet
Durchgangswiderstand: ) 3 m1
Crimpanschluss:
- mm2 0,06 - 2,2 mm2
- AWG 28 - 14
Bestell-Nr.
Order No.
Bestelltext
Designation
Bezeichnung
Description
8A
Material: Copper alloy
Finish:
- gold plated
Contact resistance: ) 3 m1
Crimp terminal :
- mm2 0,06 - 2,2 mm2
- AWG 28 - 14
Verbindlich für Toleranzen der Abmessungen und technische Werte sind ausschließlich die neuesten Tyco Electronics Kundenzeichnungen bzw. Produkt-Spezifikationen, die Sie auf Anfrage erhalten.
Fettdruck = ab Lager/bold = on stock
All specifications subject to change. Consult Tyco Electronics for latest design specifications.
33
HTS Industrie Steckverbinder
HTS Heavy Duty Connectors
Crimpkontakte HN.D Serie/Crimp contacts HN.D series
10A
Bestelltext
Designation
Bezeichnung
Description
Bestell-Nr.
Order No.
Maße mm2
Dimensions mm2
Stiftkontakt versilbert
Pin contact silver plated
Stiftkontakt/Pin contact
Buchsenkontakt/Socket contact
ø 1.6
ø 3.5
ø 3.2
8
8
25
Werkstoff: Kupferlegierung
Oberfläche:
- hartversilbert
- hartvergoldet
Durchgangswiderstand: ) 3 m1
Crimpanschluss:
- mm2 0,14 - 2,5 mm2
- AWG 26 - 14
21.6
Material: Copper alloy
Finish:
- hard silver
- hard gold
Contact resistance: ) 3 m1
Crimp terminal :
- mm2 0,14 - 2,5 mm2
- AWG 26 - 14
HN.D – Gedrehte Crimpkontakte/Screw machined crimp contacts
Querschnittskennzeichnung/Designation of cross section
Kennzeichnung
Leiterquerschnitt
Abisolierlänge der
Litze
Designation
Wire cross section
Stripping length
1
0,14 - 0,37 mm2
8 mm
8 mm
2
0,5 mm2
3
0,75 - 1 mm2
8 mm
8 mm
4
1,5 mm2
6 mm
5
2,5 mm2
1-1105050-1
2-1105050-1
3-1105050-1
4-1105050-1
5-1105050-1
0,14-0,37
0,5
0,75-1,0
1,5
2,5
1-1105050-2
2-1105050-2
3-1105050-2
4-1105050-2
5-1105050-2
0,14-0,37
0,5
0,75-1,0
1,5
2,5
1-1105051-1
2-1105051-1
3-1105051-1
4-1105051-1
5-1105051-1
0,14-0,37
0,5
0,75-1,0
1,5
2,5
1-1105051-2
2-1105051-2
3-1105051-2
4-1105051-2
5-1105051-2
0,14-0,37
0,5
0,75-1,0
1,5
2,5
Stiftkontakt vergoldet
Pin contact gold plated
Buchsenkontakt versilbert
Socket contact silver plated
Buchsenkontaktvergoldet
Socket contact gold plated
Werkzeuge für Crimptechnik HN.D Serie/Crimping tools HN.D series
Bezeichnung
Description
Crimpzange ohne Locator und Matrize
Crimping tool without locator and die
Bestelltext
Designation
Bestell-Nr.
Order No.
RSZ.BAS
1-1105850-8
RSZ.HE-HN.D-HVT
1-1105851-8
RSZ.LC 0,14-4 mm2
1-1105852-8
Crimpzange ohne Locator
Crimping tool without locator
Daniels Tool AF8
601967-1
Locator hierzu
Locator for the tool
Turnet
523168-5
AWZG-HN.D-RSZ
0-1102855-2
EWZG-RSZ
0-1102855-6
Crimpzange mit Locator und Matrize
Crimping tool with locator and die
Locator und Matrize 0,14 – 4mm2
Locator and die 0,14 – 4mm2
Ausdrückwerkzeug HN.D/Extraction tool HN.D
Eindrückwerkzeug/Insertion tool
34
Querschnitt mm2
Cross section mm2
0,14-4mm2
alle Querschnitte
all cross sections
Verbindlich für Toleranzen der Abmessungen und technische Werte sind ausschließlich die neuesten Tyco Electronics Kundenzeichnungen bzw. Produkt-Spezifikationen, die Sie auf Anfrage erhalten.
Fettdruck = ab Lager/bold = on stock
All specifications subject to change. Consult Tyco Electronics for latest design specifications.
HTS Industrie Steckverbinder
HTS Heavy Duty Connectors
Crimpkontakte HD.M Serie/Crimp contacts HD.M series
10A
Bestelltext
Designation
Bezeichnung
Description
Stiftkontakt/Pin contact
Buchsenkontakt/Socket contact
24,2
Bestell-Nr.
Order No.
Maße mm2
Dimensions mm2
Stiftkontakt verzinnt
Pin contact tin plated
1-1105000-3
2-1105000-3
4-1105000-3
0,3 – 0,56
0,5 – 1,5
1,5 – 2,5
Bandkontakt/Stift verzinnt
Reel contact/pin tin plated
0-0164161-9
0-0166824-2
0,5 – 1,5
1,5 – 2,5
Stiftkontakt vergoldet
Pin contact gold plated
1-1105000-2
3-1105000-2
0,3 – 0,56
0,8 – 1,5
Bandkontakt/Stift vergoldet
Reel contact/pin gold plated
0-0164160-4
0-0164161-4
0,3 – 0,56
0,8 – 1,5
Buchsenkontakt verzinnt
Socket contact tin plated
1-1105001-3
2-1105001-3
4-1105001-3
0,3 – 0,56
0,5 – 1,5
1,5 – 2,5
Buchsenkontakt vergoldet
Socket contact gold plated
1-1105001-2
3-1105001-2
0,3 – 0,56
0,8 – 1,5
Bandkontakt/Buchse vergoldet
Reel contact/socket gold plated
1-0163087-1
0-0163083-7
0,3 – 0,56
0,8 – 1,5
11,7
ø1,6
14,5
Werkstoff: Kupferlegierung
Oberfläche:
- verzinnt
- hartvergoldet
Durchgangswiderstand: ) 3 m1
Crimpanschluss:
- mm2 0,14 - 2,5 mm2
- AWG 26 - 14
Material: Copper alloy
Finish:
- tin plated
- hard gold
Contact resistance: ) 3 m1
Crimp terminal :
- mm2 0,14 - 2,5 mm2
- AWG 26 - 14
HD.M – Gestanzte Crimpkontakte/Stamped machined crimp contacts
Querschnittskennzeichnung/Designation of cross section
Kennzeichnung
Leiterquerschnitt
Abisolierlänge der
Litze
Designation
Wire cross section
Stripping length
1
0,2 - 0,56 mm2
3,5 mm
2
0,5 - 1,5 mm2
3,5 mm
3,5 mm
3
0,8 - 1,5 mm2
4
1,5 - 2,5 mm2
3,5 mm
Verpackungseinheiten/Packing unit
Kontakte am Band/Contacts on reel: A= 5.000 Stück/Pieces, B= 4.000 Stück/Pieces
Werkzeuge für Crimptechnik HD.M Serie/Crimping tools HD.M series
Bezeichnung
Description
Crimpzange ohne Locator und Matrize
Crimping tool without locator and die
Bestelltext
Designation
Bestell-Nr.
Order No.
RSZ.BAS
1-1105850-8
Locator und Matrize
Locator and die
ERGO-DIE XII
0-0539668-2
Ausdrückwerkzeug HD.M/Extraction tool HD.M
AWZG-HD.M-RSZ
0-1102855-1
Eindrückwerkzeug/Insertion tool
EWZG-RSZ
0-1102855-6
Querschnitt mm2
Cross section mm2
0,2-2,5mm2
für Kontakte PN
for contacts PN
alle Querschnitte
all cross
sections
unter 0,75mm2
below 0,75mm2
Verbindlich für Toleranzen der Abmessungen und technische Werte sind ausschließlich die neuesten Tyco Electronics Kundenzeichnungen bzw. Produkt-Spezifikationen, die Sie auf Anfrage erhalten.
Fettdruck = ab Lager/bold = on stock
All specifications subject to change. Consult Tyco Electronics for latest design specifications.
35
HTS Industrie Steckverbinder
HTS Heavy Duty Connectors
Crimpkontakte HGQ10 Serie/Crimp contacts HGQ10 series
20A
Bestell-Nr.
Order No.
Bestelltext
Designation
Bezeichnung
Description
Werkzeug
Tool
Stiftkontakt verzinnt
Pin contact tin plated
962966-1
962967-1
962968-1
962969-1
0,2 – 0,4
0,5 – 1,0
1,0 – 2,5
2,5 – 4,0
734285-1
734285-1
734285-2
734285-3
Bandkontakt/Stift verzinnt
Reel contact/pin tin plated
929962-1
929963-1
929964-1
929965-1
0,2 – 0,4
0,5 – 1,0
1,0 – 2,5
2,5 – 4,0
734285-1
734285-1
734285-2
734285-3
Buchsenkontakt verzinnt
Socket contact tin plated
962976-1
962977-1
962978-1
962979-1
0,2 – 0,4
0,5 – 1,0
1,0 – 2,5
2,5 – 4,0
734285-1
734285-1
734285-2
734285-3
Bandkontakt/Buchse verzinnt
Reel contact/socket tin plated
929969-1
929970-1
929971-1
929972-1
0,2 – 0,4
0,5 – 1,0
1,0 – 2,5
2,5 – 4,0
734285-1
734285-1
734285-2
734285-3
Stiftkontakt/Pin contact
Buchsenkontakt/Socket contact
Maße mm2
Dimensions mm2
29,8
9,5
20,7
Werkstoff: Kupferlegierung
Oberfläche:
- verzinnt
Durchgangswiderstand: ) 3 m1
Crimpanschluss:
- mm2 0,2 - 4,0 mm2
- AWG 24 - 12
Material: Copper alloy
Finish:
- tin plated
Contact resistance: ) 3 m1
Crimp terminal :
- mm2 0,2 - 4,0 mm2
- AWG 24 - 12
Andere Oberflächen und Werkstoffe auf Anfrage
Other finishes and Materials on request
Product Spec.: 108-18027
Appl. Spec.: 114-18018
Werkzeuge für Crimptechnik HGQ10 Serie/Crimping tools HGQ10 series
Bezeichnung
Description
Ausdrückwerkzeug /Extraction tool
Bestelltext
Designation
Extraction tool
Bestell-Nr.
Order No.
Querschnitt mm2
Cross section mm2
872070-1
Halb-/Vollautomat auf Anfrage
Bench and Automatic tooling on request
36
Verbindlich für Toleranzen der Abmessungen und technische Werte sind ausschließlich die neuesten Tyco Electronics Kundenzeichnungen bzw. Produkt-Spezifikationen, die Sie auf Anfrage erhalten.
Fettdruck = ab Lager/bold = on stock
All specifications subject to change. Consult Tyco Electronics for latest design specifications.
HTS Industrie Steckverbinder
HTS Heavy Duty Connectors
Crimpkontakte HE/HA Serie/Crimp contacts HE/HA series
Bestelltext
Designation
Bezeichnung
Description
Stiftkontakt versilbert
Pin contact silver plated
Stiftkontakt/Pin contact
Buchsenkontakt/Socket contact
ø2.5
ø4.5
ø4.5
7.5
Werkstoff: Kupferlegierung
Oberfläche:
- hartversilbert
- hartvergoldet
Durchgangswiderstand: ) 1 m1
Crimpanschluss:
- mm2 0,5 - 4,0 mm2
- AWG 20 - 12
22
Material: Copper alloy
Finish:
- hard silver
- hard gold
Contact resistance: ) 1 m1
Crimp terminal :
- mm2 0,5 - 4,0 mm2
- AWG 20 - 12
HE/HA – Gedrehte Crimpkontakte/Screw machined crimp contacts
Querschnittskennzeichnung/Designation of cross section
Kennzeichnung
Leiterquerschnitt Abisolierlänge der
Litze
Designation
Wire cross section
Stripping length
keine Rille/no groove
0,5 mm2
7,5 mm
1 Rille/1 groove
0,75 - 1 mm2
7,5 mm
7,5 mm
2 Rillen/2 grooves
1,5 mm2
3 Rillen/3 grooves
2,5 mm2
7,5 mm
7,5 mm
keine Rille/no groove
4,0 mm2
Bestell-Nr.
Order No.
Maße mm2
Dimensions mm2
6-1105100-1
1-1105100-1
2-1105100-1
3-1105100-1
4-1105100-1
5-1105100-1
0,14
0,5
0,75 – 1
1,5
2,5
4,0
1-1105100-2
2-1105100-2
3-1105100-2
4-1105100-2
5-1105100-2
0,5
0,75 – 1
1,5
2,5
4,0
6-1105101-1
1-1105101-1
2-1105101-1
3-1105101-1
4-1105101-1
5-1105101-1
0,14
0,5
0,75 – 1
1,5
2,5
4,0
1-1105101-2
2-1105101-2
3-1105101-2
4-1105101-2
5-1105101-2
0,5
0,75 – 1
1,5
2,5
4,0
Stiftkontakt vergoldet
Pin contact gold plated
7.5
25
16A
Buchsenkontakt versilbert
Socket contact silver plated
Buchsenkontakt vergoldet
Socket contact gold plated
Werkzeuge für Crimptechnik HE/HA Serie/Crimping tools HE/HA series
Bezeichnung
Description
Bestelltext
Designation
Bestell-Nr.
Order No.
Querschnitt mm2
Cross section mm2
Crimpzange ohne Locator und Matrize
Crimping tool without locator and die
RSZ.BAS
1-1105850-8
Crimpzange mit Locator und Matrize
Crimping tool with locator and die
RSZ.HE-HN.D-HVT
1-1105851-8
Locator und Matrize 0,14 – 4mm2
Locator and die 0,14 – 4mm2
RSZ.LC 0,14-4 mm2
1-1105852-8
Crimpzange ohne Locator
Crimping tool without locator
Daniels Tool AFS
601967-1
Locator hierzu
Locator for the tool
Turnet
523168-6
0,14-4mm2
AWZG-RSZ
0-1102855-7
alle Querschnitte
all cross
sections
EWZG-RSZ
0-1102855-6
Ausdrückwerkzeug HE/Extraction tool HE
Eindrückwerkzeug/Insertion tool
0,14-4mm2
Verbindlich für Toleranzen der Abmessungen und technische Werte sind ausschließlich die neuesten Tyco Electronics Kundenzeichnungen bzw. Produkt-Spezifikationen, die Sie auf Anfrage erhalten.
Fettdruck = ab Lager/bold = on stock
All specifications subject to change. Consult Tyco Electronics for latest design specifications.
37
HTS Industrie Steckverbinder
HTS Heavy Duty Connectors
Crimpkontakte HVT Serie/Crimp contacts HVT series
16A
Bestelltext
Designation
Bezeichnung
Description
Stiftkontakt/Pin contact
ø2.4
6-1105300-1
1-1105300-1
2-1105300-1
3-1105300-1
4-1105300-1
5-1105300-1
0,13 - 0,4
0,5
0,75 – 1,0
1,5
2,5
4,0
Stiftkontakt vergoldet
Pin contact gold plated
6-1105300-2
1-1105300-2
2-1105300-2
3-1105300-2
4-1105300-2
5-1105300-2
0,13 - 0,4
0,5
0,75 – 1,0
1,5
2,5
4,0
Buchsenkontakt versilbert
Socket contact silver plated
6-1105301-1
1-1105301-1
2-1105301-1
3-1105301-1
4-1105301-1
5-1105301-1
0,13 - 0,4
0,5
0,75 – 1,0
1,5
2,5
4,0
Buchsenkontakt vergoldet
Socket contact gold plated
6-1105301-2
1-1105301-2
2-1105301-2
3-1105301-2
4-1105301-2
5-1105301-2
0,13 - 0,4
0,5
0,75 – 1,0
1,5
2,5
4,0
ø4.1
8
8
24.25
26.75
Werkstoff: Kupferlegierung
Oberfläche:
- hartversilbert
- hartvergoldet
Durchgangswiderstand: ) 3 m1
Crimpanschluss:
- mm2 0,13 - 4,0 mm2
- AWG 20 - 12
Maße mm2
Dimensions mm2
Stiftkontakt versilbert
Pin contact silver plated
Buchsenkontakt/Socket contact
ø4.1
Bestell-Nr.
Order No.
Material: Copper alloy
Finish:
- hard silver
- hard gold
Contact resistance: ) 3 m1
Crimp terminal :
- mm2 0,13 - 4,0 mm2
- AWG 20 - 12
HVT – Gedrehte Crimpkontakte/Screw machined crimp contacts
Querschnittskennzeichnung/Designation of cross section
Kennzeichnung
Leiterquerschnitt
Abisolierlänge der
Litze
Designation
Wire cross section
Stripping length
1
0,13 - 0,4 mm2
8 mm
2
0,5 mm2
8 mm
8 mm
3
0,75 - 1 mm2
4
1,5 mm2
8 mm
5
2,5 mm2
8 mm
8 mm
6
4,0 mm2
Werkzeuge für Crimptechnik HVT Serie/Crimping tools HVT series
Bezeichnung
Description
Bestell-Nr.
Order No.
Querschnitt mm2
Cross section mm2
Crimpzange ohne Locator und Matrize
Crimping tool without locator and die
RSZ.BAS
1-1105850-8
Crimpzange mit Locator und Matrize
Crimping tool with locator and die
RSZ.HE-HN.D-HVT
1-1105851-8
Locator und Matrize 0,14 – 4mm2
Locator and die 0,14 – 4mm2
RSZ.LC 0,14-4 mm2
1-1105852-8
Crimpzange ohne Locator
Crimping tool without locator
Daniels Tool AFS
601967-1
Locator hierzu
Locator for the tool
Turnet
523168-5
0,14-4mm2
AWZG-RSZ
0-1102855-3
alle Querschnitte
all cross
sections
EWZG-RSZ
0-1102855-6
Ausdrückwerkzeug HE/Extraction tool HE
Eindrückwerkzeug/Insertion tool
38
Bestelltext
Designation
0,14-4mm2
Verbindlich für Toleranzen der Abmessungen und technische Werte sind ausschließlich die neuesten Tyco Electronics Kundenzeichnungen bzw. Produkt-Spezifikationen, die Sie auf Anfrage erhalten.
Fettdruck = ab Lager/bold = on stock
All specifications subject to change. Consult Tyco Electronics for latest design specifications.
HTS Industrie Steckverbinder
HTS Heavy Duty Connectors
Crimpkontakte HSK Serie/Crimp contacts HSK series
40A
Bestelltext
Designation
Bezeichnung
Description
Bestell-Nr.
Order No.
Maße mm2
Dimensions mm2
Stiftkontakt versilbert
Pin contact silver plated
Stiftkontakt/Pin contact
1-1108757-1
2-1108757-1
3-1108757-1
4-1108757-1
5-1108757-1
Buchsenkontakt/Socket contact
ø4
ø 6,25
ø 6,25
34,8
Werkstoff: Kupferlegierung
Oberfläche:
- hartversilbert
- hartvergoldet
Durchgangswiderstand: ) 3 m1
Crimpanschluss:
- mm2 1,5 - 10,0 mm2
- AWG 16 - 8
Stiftkontakt vergoldet
Pin contact gold plated
auf Anfrage/
on request
28,25
Material: Copper alloy
Finish:
- hard silver
- hard gold
Contact resistance: ) 3 m1
Crimp terminal :
- mm2 1,5 - 10,0 mm2
- AWG 16 - 8
HSK – Gedrehte Crimpkontakte/Screw machined crimp contacts
Querschnittskennzeichnung/Designation of cross section
Kennzeichnung
Leiterquerschnitt Abisolierlänge der
Litze
Designation
Wire cross section
Stripping length
11,5 mm
4
1,5 mm2
5
2,5 mm2
11,5 mm
11,5 mm
6
4 mm2
11,5 mm
7
6 mm2
11,5 mm
8
10 mm2
1,5
2,5
4
6
10
Buchsenkontakt versilbert
Socket contact silver plated
1-1108756-1
2-1108756-1
3-1108756-1
4-1108756-1
5-1108756-1
1,5
2,5
4
6
10
Buchsenkontakt vergoldet
Socket contact gold plated
auf Anfrage/
on request
Werkzeuge für Crimptechnik HSK Serie/Crimping tools HSK series
Bezeichnung
Description
Bestelltext
Designation
Bestell-Nr.
Order No.
Querschnitt mm2
Cross section mm2
Crimpzange ohne Locator und Matrize
Crimping tool without locator and die
RSZ.BAS
1-1105850-8
Matrize
die
HSK.RSZ.LC 0,75-2,5 mm2
HSK.RSZ.LC 4-10 mm2
0-1102789-1
0-1102790-1
Crimpzange ohne Locator
Crimping tool without locator
Daniels Tool AFS
601967-1
Locator hierzu
Locator for the tool
Turnet
523168-7
1,5-10mm2
Ausdrückwerkzeug HSK
Extraction tool HSK
AWZG-HSK-RSZ
0-1102855-8
alle Querschnitte
all cross
sections
EWZG-RSZ
0-1102855-6
Eindrückwerkzeug/Insertion tool
Verbindlich für Toleranzen der Abmessungen und technische Werte sind ausschließlich die neuesten Tyco Electronics Kundenzeichnungen bzw. Produkt-Spezifikationen, die Sie auf Anfrage erhalten.
Fettdruck = ab Lager/bold = on stock
All specifications subject to change. Consult Tyco Electronics for latest design specifications.
39
HTS Industrie Steckverbinder
HTS Heavy Duty Connectors
Crimpkontakte HSM Serie/Crimp contacts HSM series
40A
Bestelltext
Designation
Bezeichnung
Description
Stiftkontakt/Pin contact
Bestell-Nr.
Order No.
Maße mm2
Dimensions mm2
Stiftkontakt versilbert
Pin contact silver plated
1-1105250-1
2-1105250-1
3-1105250-1
4-1105250-1
5-1105250-1
6-1105250-1
0,75-1
1,5
2,5
4
6
10
Buchsenkontakt versilbert
Socket contact silver plated
1-1105251-1
2-1105251-1
3-1105251-1
4-1105251-1
5-1105251-1
6-1105251-1
0,75-1
1,5
2,5
4
6
10
Buchsenkontakt/Socket contact
ø 3,6 ø 6,25
ø 6,25
31
Werkstoff: Kupferlegierung
Oberfläche:
- hartversilbert
- hartvergoldet
Durchgangswiderstand: ) 3 m1
Crimpanschluss:
- mm2 0,75 - 10,0 mm2
- AWG 20 - 6
28,5
Material: Copper alloy
Finish:
- hard silver
- hard gold
Contact resistance: ) 3 m1
Crimp terminal :
- mm2 0,75 - 10,0 mm2
- AWG 20 - 6
HSM – Gedrehte Crimpkontakte/Screw machined crimp contacts
Querschnittskennzeichnung/Designation of cross section
Kennzeichnung
Leiterquerschnitt Abisolierlänge der
Litze
Designation
Wire cross section
Stripping length
10 mm
3
0,75 mm2
4
1,5 mm2
10 mm
10 mm
5
2,5 mm2
6
4 mm2
10 mm
10 mm
7
6 mm2
10 mm
8
10 mm2
Werkzeuge für Crimptechnik HSM Serie/Crimping tools HSM series
Bezeichnung
Description
Bestell-Nr.
Order No.
Crimpzange ohne Locator und Matrize
Crimping tool without locator and die
RSZ.BAS
1-1105850-8
Matrize für HSM-Kontakte
die for HSM-contacts
HSM.RSZ.LC 0,75-2,5 mm2
HSM.RSZ.LC 4-10 mm2
1-1105870-8
2-1105870-8
Ausdrückwerkzeug HSM
Extraction tool HSM
Eindrückwerkzeug/Insertion tool
40
Bestelltext
Designation
AWZG-HSM-RSZ
0-1102855-4
EWZG-RSZ
0-1102855-6
Querschnitt mm2
Cross section mm2
alle
Querschnitte
all cross
sections
Verbindlich für Toleranzen der Abmessungen und technische Werte sind ausschließlich die neuesten Tyco Electronics Kundenzeichnungen bzw. Produkt-Spezifikationen, die Sie auf Anfrage erhalten.
Fettdruck = ab Lager/bold = on stock
All specifications subject to change. Consult Tyco Electronics for latest design specifications.
HTS Industrie Steckverbinder
HTS Heavy Duty Connectors
Crimpkontakte HSS Serie/Crimp contacts HSS series
Bezeichnung
Description
63A
Bestelltext
Designation
Bestell-Nr.
Order No.
Maße mm2
Dimensions mm2
Stiftkontakt versilbert
Pin contact silver plated
Stiftkontakt/Pin contact
Buchsenkontakt/Socket contact
ø8.7
ø5
34
Werkstoff: Kupferlegierung
Oberfläche:
- hartversilbert, 2,5 - 16 mm2
- hartvergoldet, 6 - 16 mm2
Durchgangswiderstand: ) 1 m1
Crimpanschluss:
- mm2 2,5 - 16 mm2
- AWG 14 - 4
6,0
10
16
3-1105150-2
4-1105150-2
5-1105150-2
6,0
10
16
3-1105151-1
4-1105151-1
5-1105151-1
6,0
10
16
3-1105151-2
4-1105151-2
5-1105151-2
6,0
10
16
ø8.7
12
12
3-1105150-1
4-1105150-1
5-1105150-1
28.5
Material: Copper alloy
Finish:
- hard silver, 2,5 - 16 mm2
- hard gold, 6 - 16 mm2
Contact resistance: ) 1 m1
Crimp terminal :
- mm2 2,5 - 16 mm2
- AWG 14 - 4
HSS – Gedrehte Crimpkontakte/Screw machined crimp contacts
Querschnittskennzeichnung/Designation of cross section
Kennzeichnung
Leiterquerschnitt Abisolierlänge der
Litze
Designation
Wire cross section
Stripping length
12 mm
6,0 mm2
12 mm
10 mm2
12 mm
16 mm2
Stiftkontakt vergoldet
Pin contact gold plated
Buchsenkontakt versilbert
Socket contact silver plated
Buchsenkontaktvergoldet
Socket contact gold plated
Werkzeuge für Crimptechnik HSS Serie/Crimping tools HSS series
Bezeichnung
Description
Bestelltext
Designation
Bestell-Nr.
Order No.
Querschnitt mm2
Cross section mm2
Crimpzange ohne Crimpbacken
Crimping tool without crimping jaws
HSS-CSZ.2,5-70mm2
1-1105653-8
2,5-70mm2
Crimpbacken für HSM, HSL, HSS
Crimping jaws for HSM, HSL, HSS
CB-HSS-CSZ.6mm2
CB-HSS-CSZ.10mm2
CB-HSS-CSZ.16mm2
2-1105653-8
3-1105653-8
4-1105653-8
2,5-16mm2
Crimpzange ohne Locator und Matrize
Crimping tool without locator and die
RSZ.BAS
1-1105850-8
Locator
Locator
RSZ.LC 6+25 mm2
RSZ.LC 10+16 mm2
1-1105652-8
2-1105652-8
Ausdrückwerkzeug HSS/AIR
Extraction tool HSS/AIR
AWZG-HSS-RSZ
0-1102855-5
6+25mm2
10+16mm2
alle Querschnitte
all cross
sections
Verbindlich für Toleranzen der Abmessungen und technische Werte sind ausschließlich die neuesten Tyco Electronics Kundenzeichnungen bzw. Produkt-Spezifikationen, die Sie auf Anfrage erhalten.
Fettdruck = ab Lager/bold = on stock
All specifications subject to change. Consult Tyco Electronics for latest design specifications.
41
HTS Industrie Steckverbinder
HTS Heavy Duty Connectors
Crimphülsen max. 150 A/Crimping sleeves max. 150 A
Crimphülsen für Kontaktserie HF-06/Crimping sleeves for contact series HF-06
Bestelltext
Designation
Bezeichnung
Description
Crimphülsen für Stift-/Buchsenseite
- Schrumpfschlauch
- Crimphülse
Crimp barrel for pin-/socket side
- shrink tube
- crimp barrel
Bestell-Nr.
Order No.
CH.06mm2-SW17
CH.10mm2-SW17
CH.16mm2-SW17
CH.25mm2-SW17
CH.35mm2-SW17
CH.50mm2-SW17
CH.70mm2-SW17
0-1110952-1
0-1110952-2
0-1110952-3
0-1110952-5
0-1110952-7
0-1110952-9
1-1110952-0
HF.06.Sti.
0-1110948-1
HF.06.Bu.
0-1110949-1
Crimphülsen max. 350 A/Crimping sleeves max. 350 A
Crimphülsen für Kontaktserie HF-13/Crimping sleeves for contact series HF-13
Crimphülsen für Stift-/Buchsenseite
bestehend aus
- Schrumpfschlauch
- Crimphülse
- Adapter
Crimp barrel for pin-/socket side
- shrink tube
- crimp barrel
- adapter
CH.50mm2-13/16mm
CH.70mm2-13/16mm
CH.95mm2-13/16mm
CH.105mm2-13/16mm
CH.120mm2-13/16mm
CH.150mm2-13/16mm
0-1110953-5
0-1110953-6
0-1110953-7
0-1110953-8
0-1110953-9
1-1110953-1
HSS-CSZ.2,5-70mm2
1-1105653-8
CB-HSS-CSZ.6mm2
CB-HSS-CSZ.10mm2
CB-HSS-CSZ.16mm2
CB-HSS-CSZ.25mm2
CB-HSS-CSZ.35mm2
CB-HSS-CSZ.50mm2
CB-HSS-CSZ.70mm2
2-1105653-8
3-1105653-8
4-1105653-8
5-1105653-8
6-1105653-8
7-1105653-8
8-1105653-8
CZ-HF.60.M
0-1110956-1
SET-50-150mm2
150mm2-KZ22
120mm2-KZ20
95mm2-KZ18
70mm2-KZ16
50mm2-KZ14
0-1110956-7
0-1110956-6
0-1110956-5
0-1110956-4
0-1110956-3
0-1110956-2
Passendes Verarbeitungswerkzeug/suitable tools
Crimpzange ohne Crimpbacken
Crimping tool without crimping jaws
Crimpbacken für HSL, HSS
Crimping jaws for HSL, HSS
Hydraulische Crimpzange
Hydraulic Crimping tool
Presseinsätze
dies
42
Verbindlich für Toleranzen der Abmessungen und technische Werte sind ausschließlich die neuesten Tyco Electronics Kundenzeichnungen bzw. Produkt-Spezifikationen, die Sie auf Anfrage erhalten.
Fettdruck = ab Lager/bold = on stock
All specifications subject to change. Consult Tyco Electronics for latest design specifications.
HTS Industrie Steckverbinder
HTS Heavy Duty Connectors
Koax-Kontakte/Coax-contacts
Koax-Kontakte RG58/RG59
Wellenimpedanz
spezifischer Widerstand
Ziehkraft
Zugfestigkeit
Spannungsfestigkeit
Isolationswiderstand
Steckkraft
Werkstoff
Kontaktoberfläche
Druckhülsenoberfläche
Crimpanschluß
Coax-contacts RG58/RG59
Wave impedance
Specific resistance
Unmating force
Tensile strength
Dielectric withstanding voltage
Insulation resistance
Mating force
Material
contact surface
Ferrule surface
Crimp termination
50 1 / 75 1
max. 2m1
min. 1N
min. 50N
1000VAC über 1min
200 m1 nach 1min Betrieb
max. 1,5N
Kupferlegierung
vergoldet
versilbert
50 1 / 75 1
max. 2m(
min. 1N
min. 50N
1000VAC over/during? 1min
200 m1 after 1min operation
max. 1,5N
copper alloy
gold-plated
silver-plated
Bestelltext
Designation
Bezeichnung
Description
Koax Crimpkontakte/Coax Crimp tcontacts
KX-RG.58.Sti
KX-RG.59.Sti
Stiftkontakt
Pin contact
Bestell-Nr./Order No.
Stifteinsatz
Buchseneinsatz
Male insert
Female insert
1-1105350-1
2-1105350-1
KX-RG.58.Bu
KX-RG.59.Bu
1-1105351-1
2-1105351-1
Buchsenkontakt
Socket contact
Koax-Kontakte
Wellenimpedanz
Anschlußart
Innenleiter
Außenleiter
Kabeldurchmesser
Innenleiter
Außenleiter
75 1
Löt
Klemm
0,8/1,44/2,8
6,1/10,0/10,7
Coax-contacts
Wave impedance
Type of termination
internal conductor
outside conductor
Dimensions of the wire
internal conductor
outside conductor
75 1
solder
clamp
0,8/1,44/2,8
6,1/10,0/10,7
Bezeichnung
Description
Kabelabmasse
Cable measures
KX.RG.58
KX.RG.59
KX.VT.0,8/3,5
KX.VT.1,4/6,3
KX.VT.3,0/7,3
Bestelltext
Designation
SW13
Koax Crimpkontakte/Coax Crimp tcontacts
Stiftkontakt
Pin contact
ø 6.5
SW13
Buchsenkontakt
Socket contact
KX.VT.Sti.0,8/3,5/6,1
KX.VT.Sti.1,4/6,3/10,0
KX.VT.Sti.3,0/7,3/10,8
Innen ø
Inner ø
0,81
0,64
0,8
1,4
3,0
Schirm ø Außen ø
Braid ø Outer ø
2,95
4,95
3,71
6,15
3,5
6,1
6,3
10,0
7,3
10,8
Bestell-Nr./Order No.
Stifteinsatz
Buchseneinsatz
Male insert
Female insert
0-1108600-1
0-1108628-1
0-1108616-1
KX.VT.Bu.0,8/3,5/6,1
KX.VT.Bu.1,4/6,3/10,0
KX.VT.Bu.3,0/7,3/10,8
0-1108601-1
0-1108629-1
0-1108617-1
ø 6,5
Werkzeuge für Crimptechnik Koax/Crimping tools Coax
Bezeichnung
Description
Crimpzange Koax/Crimping tool Coax
Crimpzange Koax/Crimping tool Coax
Bestelltext
Designation
Bestell-Nr./
Order No.
KX-CZ.58
0-0045740-2
KX-CZ.59
+Matrize/Die
69710-1
69675-1
KX-AWZG.58/59
0-0305183-8
KX-VT-AWZG
1-1105752-8
Maße mm2
Dimensions mm2
Ausdrückwerkzeug KX RG 58/59
Extraction tool KX RG 58/59
Ausdrückwerkzeug KX-VT
Extraction tool KX-VT
Verbindlich für Toleranzen der Abmessungen und technische Werte sind ausschließlich die neuesten Tyco Electronics Kundenzeichnungen bzw. Produkt-Spezifikationen, die Sie auf Anfrage erhalten.
Fettdruck = ab Lager/bold = on stock
All specifications subject to change. Consult Tyco Electronics for latest design specifications.
43
HTS Industrie Steckverbinder
HTS Heavy Duty Connectors
Kontakte (Optik) HD-LWL Serie/Contacts (Optics) HD-LWL series
LWL-Kontakte (Optik)
Kontakt-Werkstoff Ms,
Zentrierhülse-Werkstoff
Zusammenstellung:
Einfügungsdämpfung
Steckhäufigkeit
Betriebstemperatur
Kabelhaltekraft im Kontakt [N]
Kontakthaltekraft im Modul
Leitungstype 1mm Plastik-Lichtwellenleiter
mit 2,2mm Mantel
Crimpanschluß
verzinnt und rostfreier Stahl
Thermoplast
kurzer Kontakt mit Zentrierhülse
langer Kontakt