General Purpose Relays
PCB Relays
SCHRACK
Reed Relay V23100 -V6
n Reed
contact
size
n Dust protected
n 1 or 2 make contacts, neutral, monostable or
n 1 make and 1 break contact, polarised, monostable
n Printed circuit mounting
n Small
Contact Data
A101
A201
A112
Minimum
voltage Ul
VDC
3.7
4.5
8.4
16.4
Maximum
voltage Ull
VDC
10.8
10.8
21.6
42.5
Contact arrangement
1 make
2 makes
1 make
1 break
Maximum
100
switching voltage
Maximum
switching current
break
0.25 A
make
0.5 A
0.5 A
0.5 A
Maximum power
10 W
rating
Maximum
continuous
current
break
make
-
-
0.25 A
0.75 A
0.75 A
0.75 A
Coil Data
Coil
code
004
001
002
003
Rated
voltage
VDC
5
6
12
24
Resistance
at 20°C
Ω
430 ± 43
430 ± 43
1100 ± 110
3860 ± 580
General
A101
A201
A112
Operating voltages
see
„Coil table“
Maximum temperature
100 °C
Continuous
max. 0,4 W
thermal load
at 20°C ambient
temperature
Permissible
-25….+70°C
ambient
t emperature
Operate time approx. 700 µs
Release time approx. 500 µs
Bounce time approx. 300 µs
Maximum
500 operations/s
switching rate
Test voltage
contact
250 V ACrms
250 V ACrms
250 V ACrms
tip/contact tip
1500 V ACrms
1500 V ACrms
750 V ACrms
contact/winding
Electrical life
at 28 V DC/125 mA
Approx. 106 operations
Mechanical life
A
pprox. 109 operations
The operating voltage limits UI and UII depend on temperature and can be calculated by:
UI tu = kI * UI 20°C and UII tu = kII * UII 20°C
tU = ambient temperatur
UItU = minimum voltage at ambient temperature tU
UII tU = maximum voltage at ambient temperature tU
kI and kII = factors
tU
kI
kII
05-2020, Rev. 0520
www.te.com
© 2015 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
20 °C
1.0
1.0
30 °C
1.04
0.93
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
40 °C
1.07
0.86
50 °C
1.1
0.79
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
60 °C
1.15
0.71
70 °C
1.18
0.62
Datasheets, product data, ‘Definitions’ section, application notes and all specifications
are subject to change.
1
General Purpose Relays
PCB Relays
Reed Relay V23100 -V6
SCHRACK
(Continued)
Dimensions
Terminal Assingment
Base terminals
Circuit symbols drawn in release condition. If a positive potencial is applied to coil terminal 1, the relay changes to operate condition
1 make
2 makes
PCB layout
Mounting hole layout
View onto the terminal
1 make and break
Minimum spacing for version with 1 make and 1 contact
Typical product code
V23100-V6
002
A101
Type
V23100-V6 - Reed relay, V23100-V6 series
Coil
004 – 5 VDC
001 – 6 VDC
002 – 12 VDC
003 – 24 VDC
Contact arrangement
A101 – 1 make
A201 – 2 makes
A112 – 1 make and 1 break
2
05-2020, Rev. 0520
www.te.com
© 2015 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ section, application notes and all specifications
are subject to change.
很抱歉,暂时无法提供与“1393803-6”相匹配的价格&库存,您可以联系我们找货
免费人工找货- 国内价格
- 3+434.18790
- 8+426.18970
- 15+418.17518
- 30+410.04640
- 国内价格 香港价格
- 2+497.914942+63.86760
- 8+439.860108+56.42090
- 15+431.5791415+55.35870
- 30+423.2100830+54.28520
- 国内价格
- 3+462.89320
- 8+454.36622
- 15+445.82681
- 30+437.15067