4
THIS DRAWING IS UNPUBLISHED.
©
COPYRIGHT
I
LOC
I
DIST
REVISIONS
HK 00
I
p
LTR
22
ECR-06-0 1 21 91
APVD
OWN
DATE
DESCRIPTION
A
D
l
1
I
I
ALL RIGHTS RESERVED.
BY TYCD ELECTRONICS CORPORATION.
-
2
3
I
RELEASED FOR PUBLICATION
09MAY06
RAH RAH
24
22
1,85
1,85
1,19
1,30
2,06
2,06
1,65
1,80
2,06
2,06
1,65
l, 80
20
18
16
14
18+22
20+20
18+20
18+18
16+20
16+18
14+20
14+18
14+16
12+20
12+18
12
10
2,06
2,06
2,64
2,64
2,18
2,28
2,90
3,10
3,05
3,05
2,28
2.44
D
19
18
14
3,80 U5J
3,55 U4J
-
2.4 [ 09]
t
rrT
ttJ
7,6 7 [ 302]
7.47 [ 294]
lc'-'
J
II
Tl-
t
2,8 Ull
[I_
I
[J
I~
t
L.!.....f
-f- -
13
~
-
01
-----'r
..A
11
1==.
~-
10
c
L 8 9 [36JJ
-
-
c014J
3,05
lAO
1,50
1,70
1,85
1,70
1,50
1,65
1,70
1,70
1,8
3,86
3,86
3,86
3,86
3,86
3.45
345
1,72
1,80
2,06
2,21
3,05
3,05
3,71
3,71
5,69
5,69
5,69
5,69
5,69
5,69
6,60
6,60
6,60
6,60
6,60
5,[6
5,[6
CCV
CCH
IC\J
INSULA TIDN
3,05
3,05
3,05
3,05
3,05
GRIP
'WIRE
CONDUCTOR
CONDUCTOR
CODE
SIZE CA\JG)
CRIMP \JIDTH
CRIMP HIEGHT
CTDL ±0.10)
CTDL ±0.05)
!---7,5 [,29]f--20 [08]
l
--5·
4,0 [,16] I-' f--
I
,..._
-
CCH
•
3,89 U5J
3,60.[[4]
t
~
tq-::::::
~
t
'-
4
~
2-1438238-3
2-1438238-2
2-1438238-0
1438238-8
2-1438238-1
1-1438238-2
1-1438238-0
1438238-9
1438238-1
1-1438238-9
1-1438238-1
1438238-3
1438238-4
1438238-5
1438238-6
1-1438238-3
1-1438238-5
1-1438238-8
1438238-2
1-1438238-7
1-1438238-6
1-1438238-4
-
-
A
TYCD
ELECTRONICS
RE\JOUND P /N
TYCO
ELECTRONICS
P/N
AMP 1470-19 REV 31MAR2000
LD\J
LD\J
LD\J
LD\J
LD\J
LD\J
11
LD\J
10
LD\J
22
LD\J
19
LD\J
18
LD\J
14
LD\J
13
LD\J
11
LD\J
10
HIGH
22
HIGH
19
HIGH
18
HIGH
14
HIGH
13
HIGH
11
HIGH
10
GRIP INSERTION
FORCE
CODE
22
19
18
14
13
ICH
INSLATIDN
CRIMP
HIEGHT CTHIN
\JALU
CTDL ±0.10)
IC\J
INSULATION
ccw
~
CRIMP
CRIMP
HIEGHT CSTD
\JALU
\JALU
CTDL ±0.10)
\JALU
~1cw-
CTDL ±0.10)
c
I
•
~
ICH
INSLATIDN
WIDTH CSTD
CTDL ±0.10)
RECDMENDED CRIMP DIMENSIONS
f--
ICH
I
CP
~
21,5 [,85]
3,80
4,10
CRIMP
WIDTH CTHIN
~
B
f--
B
REWOUND REELING DIRECTION
STANDARD REELING DIRECTION
TERMINALS ARE TO BE REELED WITH THE CRIMP
GRIPS UP AND TO THE NEAR SIDE. UNWIND
DIRECTION FROM LEFT TO RIGHT
TERMINALS ARE TO BE REELED WITH THE CRIMP
GRIPS UP AND TO THE NEAR SIDE. UNWIND
DIRECTION FROM RIGHT TO LEFT
f--
THIS DRAWING IS A CONTROLLED DOCUMENT,
OWN
09 MAY 2003
JR
BUSSARD
CHK
DIMENSIONS:
TOLERANCES UNLESS
OTHERWISE SPECIFIED:
MM
MATERIAL
*CJ
-
0 PLC
1 PLC
2 PLC
3 PLC
4 PLC
ANGLES
±±± .25
±±-
FINISH
09 MAY 2003
OM
09 MAY 2003
NAME
REVAK
TERMINAL BLADE TYPE
PRODUCT SPEC
FEMALE
-
+z
-
WEIGHT
CUSTOMER
A
-
APPLICATION SPEC
-
-
I
Harrisburg, PA 17105-3608
REVAK
APVD
OM
Tyco Electronics Corporation
~~Electronics
DRAWING
SIZE
CAGE CODE
A3
00779
DRAWING NO
RESTRICTED TO
©=1438238
I
4:1
SCALE
-
I
SHEET
1
OF
1
I
REV
A