0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
1744489-8

1744489-8

  • 厂商:

    HUMIREL(泰科)

  • 封装:

    -

  • 描述:

    3.96EPHDRASY08PNOPEG,GW

  • 数据手册
  • 价格&库存
1744489-8 数据手册
Introducing GLOW WIRE TEST COMPLIANT ECONOMY POWER II (EP II) CONNECTORS AND TPA DEVICES APPLIANCES /// ECONOMY POWER II Economy Power II Connectors and TPA devices TE Connectivity (TE) offers Economy Power II (EP II) Glow Wire connectors in many different styles and configurations to meet safety and environmental requirements requested by the home appliances industry. Several connector housing and header styles and configurations are available in Glow Wire compatible material that also meets UL 94 V-0 requirements. The use of Glow Wire test compliant components may Key Features • .156” centerline (3.96mm) • Lance-less terminal • Wire size: 0.26 to 1.33 mm2 22 to 16 AWG • Voltage up to 600 VAC allow users to reduce the time and expense of end-product testing • Current up to 11.5 A associated with Glow Wire ignition and Glow Wire flammability index. • Housing locking latch • Polarization tabs Electrical • Voltage rating: 600 VAC • Current rating: 11.5 A Mechanical • Position: 2 to 12 single row wire-to-board • Wire size: 0.26 to 1.33 mm2 (22 to 16 AWG) • Asymmetrical terminals can only be loaded one way • Breakaway style or discrete Terminal Position Assurance (TPA) devices • Centerline: .156” (3.96 mm) • Probe tip windows for continuity testing • Operating temperature: -55 to 105°C • Contact lubrication • Selectively loaded headers available upon request • Parts molded in various colors are available upon request Materials • Glow Wire products Compliant to Glow Wire test required by IEC/EN 60335-1 5th Edition: Household and Similar Appliances - Safety and UL 94 V-0 • Comply with Glow Wire flammability index (GWFI) 850°C at least, according to IEC 60335-1, Glow Wire flammability test for endproducts (GWEPT) 750°C No Flame, according to IEC 60335-1 and UL 94 V-0 • Contacts: Tin plated copper alloy • Glow Wire products compliant to Glow Wire test required by IEC/ EN 60335-1 5th Edition: Household and Similar Appliances - Safety and UL 94 V-0 Standards • UL recognized E28476 • Application specification number: 114-13265 Applications • Household appliances • HVAC • Industrial machinery (e.g. control boards) • Products can be used for global applications where compliance to IEC 60335-1 and UL 94 V-0 is required. APPLIANCES /// ECONOMY POWER II PAGE 2 ECONOMY POWER II Product Offering Housing Product Image Type Receptacle Housing Style Flammability Part Number Position 2 UL 94 V-0 X-2132813-Y -2 UL 94 V-0 X-2132781-Y GWT acc. IEC 60335-1 and UL 94 V-0 X-1744416-Y Single Row -2 3 4 5 6 7 8 9 10 11 12 -3 -4 -5 -6 -7 -8 -9 1--0 1--1 1--2 -3 -4 -5 -6 -7 -8 -9 1--0 1--1 1--2 *Colored housings are available upon request. For more information, contact TE sales representative. Terminal Position Assurance (TPA) - Optional Product Image Type Style Flammability and TPA Type Number of Positions Position Terminal Position Assurance (TPA) Contact Locking Plate UL 94 V-0 Breakaway X-2132782-Y UL 94 V-O Discrete X-1744544-Y Type Style Flammability 2 3 4 5 6 7 8 9 10 11 12 1--2 -2 -3 -4 -5 -6 -7 -8 -9 1--0 1--1 7 8 9 10 11 1--8 1--9 1--0 1--1 Header Product Image Vertical Header No orientation post Single Row Vertical Header With orientation post Single Row Shrouded Header Single Row Right Angle Header Single Row Position 2 UL 94 V-0 X-1123723-Y 1--2 UL 94 V-0 X-647689-Y GWT acc. IEC 60335-1 and UL 94 V-O X-1744489-Y -2 -3 -4 -5 -6 -7 -8 -9 1--0 1--1 1--2 UL 94 V-0 X-1744057-Y -2 -3 -4 -5 -6 -7 -8 -9 1--0 1--1 1--2 GWT acc. IEC 60335-1 and UL 94 V-O X-1744429-Y -2 -3 -4 -5 -6 -7 -8 -9 1--0 1--1 1--2 UL 94 V-0 X-1877285-Y -2 -3 -4 -5 -6 -7 -8 -9 1--0 1--1 1--2 GWT acc. IEC 60335-1 and UL 94 V-2 X-1744427-Y -2 -3 -4 -5 -6 -7 -8 -9 1--0 1--1 1--2 UL-94 V-0 X-647676-Y -2 -3 -4 -5 -6 -7 -8 -9 1--0 1--1 1--2 GWT acc. IEC 60335-1 and UL 94 V-0 X-1744428-Y -2 -3 -4 -5 -6 -7 -8 -9 1--0 1--1 1--2 3 4 5 6 1--3 1--4 1--5 1--6 1--7 12 1--2 Application Tooling Contact Product Image Part Number Type Style Phos Bronze Pre-Tin Contact 18-22 AWG (0.89-0.30mm2) Receptacle Contact Phos Bronze Pre-Tin Contact 16-20 AWG (1.4-0.5mm2) Receptacle Contact Part Number Part Number 90720-1 1744144-1 91337-1 2119118-1 1744201-1 Part Number Ordering: Example for X-1744416-Y Housing* -2 thru -9 Substitute dash number listed for “Y”, therefore a -2 signifies PN 174416-2 Straight Action Hand Tool PRO-CRIMPER III Hand Tool Assembly 354500-[] AMP-O-LECTRIC Model “G” Terminating Machine 1725950-[] AMP 3/K-40 Press 528324-[] Komax Gamma 333 PC 1385286-[] Side Feed HDM Applicator 91579-1 Side 1--0 thru 1--2 Substitute first number for “X” and second number listed for “Y”, therefore 1--2 signifes PN 1-1744416-2 *Follow same numbering scheme throughout for other part numbers listed APPLIANCES /// ECONOMY POWER II PAGE 3 TE Connectivity Technical Support Center USA: +1 (800) 522-6752 Canada: +1 (905) 475-6222 Mexico: +52 (0) 55-1106-0800 Latin/S. America +54 (0) 11-4733-2200 Germany: +49 (0) 6251-133-1999 UK: +44 (0) 800-267666 France: +33 (0) 1-3420-8686 Netherlands: +31 (0) 73-6246-999 China: +86 (0) 400-820-6015 te.com © 2015 TE Connectivity Ltd. family of companies. All Rights Reserved. 1-1773702-6 APP CS 12/2015 TE Connectivity and the TE connectivity (logo) are trademarks of the TE Connectivity Ltd. family of companies.. While TE has made every reasonable effort to ensure the accuracy of the information in this document, TE does not guarantee that it is error-free, nor does TE make any other representation, warranty or guarantee that the information is accurate, correct, reliable or current. TE reserves the right to make any adjustments to the information contained herein at any time without notice. TE EXPRESSLY DISCLAIMS ALL IMPLIED WARRANTIES REGARDING THE INFORMATION CONTAINED HEREIN, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. In no event will TE be liable for any direct, indirect, incidental, special or consequential damages arising from or related to recipient’s use of the information. It is the sole responsibility of the recipient of this information to verify the results of this information using their engineering and product environment, Recipient assumes and all risks associated with the use of the information. The dimensions in this document are for reference purposes only and are subject to change without notice. All specifications are subject to change without notice. Consult TE for the latest dimensions and design specifications. APPLIANCES /// ECONOMY POWER II
1744489-8 价格&库存

很抱歉,暂时无法提供与“1744489-8”相匹配的价格&库存,您可以联系我们找货

免费人工找货