EPD6314
SPECIFICATION CONTROL DRAWING
CHEMINAX
Date:
Revision:
DATA BUS CABLE, MULTIPLEX
8-2-04
L
THIS SPECIFICATION SHEET FORMS A PART OF THE LATEST ISSUE OF RAYCHEM SPECIFICATION 1200.
CONSTRUCTION DETAILS
DIMENSIONS ARE NOMINAL VALUES IN INCHES UNLESS
OTHERWISE DESIGNATED.
CONDUCTOR
AWG 24, 19 Strands of
AWG 36, Nickel-Coated
High Strength Copper
Alloy, Unilay
.0235
DIELECTRIC
Radiation-Crosslinked,
Modified ETFE
Color - Blue / White
.046
FILLERS
Radiation Crosslinked
Modified ETFE
.031
ELECTRICAL CHARACTERISTICS
CHARACTERISTIC IMPEDANCE
77 ± 5 ohms, Method C at 1 MHz
CAPACITANCECONDUCTOR TO CONDUCTOR
CONDUCTOR TO SHIELD
30 pF/ft. (maximum) at 1 MHz
42 pF/ft. (maximum) at 1 MHz
ATTENUATION
1.5 dB/100 ft. (maximum) at 1 MHz
ADDITIONAL REQUIREMENTS
COMPONENT WIRE PRIOR TO CABLING
(Test Procedures per MIL-W-22759)
CROSSLINK PROOF
300 ± 3°C for 1 hour,
.500 inch mandrel, .375 lb.,
2.5 kV dielectric test
-65 ± 2°C for 4 hours,
.500 inch mandrel, 1.00 lb.,
2.5 kV dielectric test
200 ± 3°C for 6 hours,
.125 inch (maximum) in 12 inches
5000 megohms for 1000 ft. (minimum)
LOW TEMPERATURE
COLD BEND
SHIELD
AWG 38,
Nickel-Coated Oxygen
Free High Conductivity
Copper
.109
SHRINKAGE
INSULATION RESISTANCE
INSULATION (DIELECTRIC)
TENSILE STRENGTH
ELONGATION
INSULATION FLAWS
SPARK TEST
IMPULSE TEST
5000 lbf/in² (minimum)
50% (minimum)
3000 volts (rms)
8.0 kV (peak)
FINISHED CABLE (Test Procedures per NEMA WC27500)
JACKET
Radiation-Crosslinked,
Modified ETFE
.125
(nominal)
.136
(maximum)
BLOCKING
LOW TEMPERATURE
COLD BEND
CROSSLINKED VERIFICATION
FLAMMABILITY
(Method B per Spec. 1200)
SHIELD COVERAGE
JACKET FLAWS
SPARK TEST
IMPULSE TEST
VOLTAGE WITHSTAND (DIELECTRIC)
JACKET THICKNESS
JACKET
TENSILE STRENGTH
ELONGATION
200°C for 6 hours
-55 ± 5°C for 4 hours
6.0 inch mandrel
300 ± 5°C for 6 hours,
6.0 inch mandrel
3 seconds (maximum); 3.0 inches
(maximum), no flaming of facial tissue
90% (minimum)
1000 volts (rms)
6.0 kV (peak)
1500 volts (rms)
.008 inch (nominal)
5000 lbf/in² (minimum)
50% (minimum)
Outer jacket color will be white (designated by a "-9" appended
to the part number, e.g. EPD6314-24-9) unless otherwise specified.
Designate outer jacket color with a dash number in accordance
with MIL-STD-681. Other codes and suffixes may be added to the
part number, as necessary, to capture any additional requirements
imposed by the purchase order.
WEIGHT
14.8 lbs/1000 ft. (maximum)
Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice.
Tyco Electronics also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer.
R
Wire & Cable
501 Oakside Avenue
Redwood City, California 94063-3800
1-800-227-8816 Fax: 1-650-361-6297
THIS SPECIFICATION SHEET TAKES PRECEDENCE
OVER DOCUMENTS REFERENCED HEREIN. REFERENCE
DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT
ON DATE OF INVITATION FOR BID.
很抱歉,暂时无法提供与“186836-001”相匹配的价格&库存,您可以联系我们找货