Introducing
UL 1500 Ignition Protected
Circuit Breakers
UL 1500
Ignition Protected
Circuit Breakers
KEY FEATURES
DESCRIPTION
Meet Ignition Protection
One through four pole secondary circuit breakers (protectors) offering
ratings from 200 milliamps to 50 amps.
Both magnetic (magnetic-hydraulic) and thermal types are available.
requirements in accordance
with UL 1500
Magnetic and thermal types
APPLICATIONS
One to four poles
Equipment in marine applications requiring secondary circuit breakers
that meet the ignition protection requirements of UL 1500.
Ratings from 200 milliamps
to 50 amps
Broad array of mounting,
actuator and termination
options
Optional bottom marking of
amperage available on
MECHANICAL
Termination options include quick connect terminals at various angles,
#6-32, #8-32 and #10-32 screws, printed circuit board terminals and
#10-32 studs.
Mounting options include a range of threaded bushings, snap-in
options and a choice of #6-32 or M3 threaded holes.
thermal models
STANDARDS AND SPECS
UL Recognized as supplementary protectors for the US and Canada,
meeting the Ignition Protection requirements of UL1500.
UL Recognized as supplementary protectors for the US and Canada,
meeting the requirements of UL1077.
UL File E69543
ELECTRICAL
RoHS
Ready
Tyco Electronics I UL 1500 Ignition Protected
Circuit Breakers
Current ratings from 0.5 to 40 amps for thermal models and from 0.2
to 50 amps for magnetic types.
Maximum operating voltages to 50 volts DC, 250 volts AC for thermal
models and 50 volts DC, 250 volts AC for magnetic types.
Interrupt capacities to 2000 amps for thermal types.
Interrupt capacities to 3000 amps @ 48 volts DC, 1000 amps @
125/250 volts AC or 250 volts AC 3-phase Wye for magnetic types.
UL 1500
Ignition Protected
Circuit Breakers
PRODUCT OVERVIEW
Series
W57
W54
W58
W6
W9
Type
Thermal
Thermal
Thermal
Magnetic
Magnetic
Features
• Compact design
• Quick connect, screw
or PC terminals
• Button extends for
visible trip indication
• Push-to-reset operation
• Quick connect, screw
pr PC terminals
• Button extends
for visible trip
indication
• Push-to-reset operation
• Quick connect or screw
terminals
• Button extends
for visible trip
indication
• Push-to-reset operation
• Compact design
• Various delay options
• Toggle/rocker actuation
for manual on/off
and reset
• Optional aux. switch
• Various delay options
• Toggle actuation for
manual on/off and reset
• Optional aux. switch
.575" x 1.15" x .889"d
(14.6 x 29.2 x 22.6d)
.5 oz. (14.3g)
.575" x 1.378" x 1.22"d
(14.6 x 35.0 x 31.0d)
.9 oz. (25g)
.66" x 1.38" x 1.38"d
(16.8 x 34.9 x 34.9d)
1.5 oz. (43g)
.75" x 2.0" x 1.64"d
(19.1 x 50.8 x 42.1d)
2.5 oz. (71g)
1
1
1
1 through 4
1 through 4
Circuit Function
Series Trip
Series Trip
Series Trip
Series Trip
Series Trip
Current Rating
3-20 Amps
5-40 Amps
0.5-30 Amps
0.2-50 Amps
0.2-50 Amps
50VDC; 250VAC
50VDC; 250VAC
48VDC; 125/250VAC;
250VAC 3∅ - Wye
48VDC; 125/250VAC;
250VAC 3∅ - Wye
4 to 40 Sec.
5 to 40 Sec.
1-4A types – 10 to 45 Sec.
5-30A types – 6 to 30 Sec.
30ms to 150 Sec.
(trip curve specific)
30ms to 150 Sec.
(trip curve specific)
Interrupt
Capacity
1,000A
1,000A
2,000A @ 50VDC
1,000A @ 250VAC
3,000A @ 48VDC
1,000A @ 125/250VAC or
250VAC 3∅ - Wye
3,000A @ 48VDC
1,000A @ 125/250VAC or
250VAC 3∅ - Wye
Terminal
Options
.250" (6.35) Quick Connect,
#8-32 Screw, PCB
.250" (6.35) Quick Connect,
#8-32 Screw, PCB
.250" (6.35) Quick Connect,
#6-32 Screw
.250" (6.35) Quick Connect,
#8-32 or #10-32 Screw
#10-32 Stud
Mounting
Options
3/8"–24, M11 –1.0 or
M12-1.0 Threaded Bushing,
Snap-In Mount
3/8"–24, M11 –1.0 or
M12-1.0 Threaded Bushing,
Snap-In Mount
7/16"–28 or 15/32”–32
Threaded Bushing
#6-32 Tapped Holes,
M3 Tapped Holes,
Snap-In Mount
#6-32 Tapped Holes,
M3 Tapped Holes
W57
W54
W58
W6
W9
Approximate Size
and Weight
(per pole for W6 & W9)
No. of Poles
Max. Operating Voltage
Trip Time at
200% of Rating
Website Search Key
50VDC; 250VAC
.75" x 2.5" x 2.1"d
(19.1 x 63.5 x 53.0d)
2.5 oz. (71g)
Notes: Specifications and availablity are subject to change without notice. Consult product series data sheets for detailed specifications. All part numbers in series described above are RoHS compliant.
UL 1500 Ignition Protected Circuit Breakers I Tyco Electronics
FOR MORE INFORMATION
Technical Support
Internet:
E-mail:
www.tycoelectronics.com
newproducts@tycoelectronics.com
USA:
Canada:
Mexico:
C. America:
South America:
Hong Kong:
Japan:
UK:
1-800-522-6752
1-905-470-4425
52-55-1106-0800
57-1-254-4444
55-11-2103-6000
852-2735-1628
81-44-844-8013
44-208-420-8341
Tyco Electronics Corporation
Harrisburg, PA
tycoelectronics.com
Copyright 2008 By Tyco Electronics Corporation
6-1773453-2—0.0M—KRG/PDF 11-08
The TE logo and Tyco Electronics are trademarks.
很抱歉,暂时无法提供与“2-1393249-3”相匹配的价格&库存,您可以联系我们找货