CII Low Signal Relays
Four Pole, Magnetic Latching, 2 Amps and Less
.150 Grid-space
Magnetic Latching Relays
Type 3SBM (4PDT)
Product Facts
n
Low profile… only 0.32
inches high
n
Internal diode for coil
transient suppression
available
n
Qualified to MIL-R-39016/31
n
Suitable for low pulse
operation — 2 ms at rated
voltage
The Type 3SBM relay adds
magnetic latching capability
to the popular and growing
family of .150-grid relays.
This relay has memory in
that the contact positions do
not change when coil power
is removed. Switching is
accomplished by applying
power to the applicable coil
(dual coil) or with the applicable polarity (single coil).
The low switching power
requirements are further
enhanced by its ability to
operate from capacitor discharge or other pulses or
through its own contacts
from batteries or similarly
limited supplies.
Electrical Characteristics
Operating Characteristics
Operate Sensitivity—
Single-coil form, 100 mW,
Dual-coil form, 180 mW
Contact Arrangement—
4-pole double-throw (4C)
Contact Ratings —
DC resistive — 2 amps at 28 volts
DC inductive — 0.5 amp at 28 volts,
200 mH
AC resistive — 0.5 amp at 115 volts
(enclosure isolated from ground, or
enclosure and movable contact at same
potential)
AC — 0.125 amp at 115 volts
(enclosure at line potential with respect
to movable contact)
Low-level — 50 µA at 50 mV
Peak AC or DC
Contact Resistance —
0.050 ohms max.;
0.150 ohms after life tests
Life —
100,000 operations at rated loads listed;
1,000,000 operations at low-level loads
Operate Time — 4 ms max.
Release Time — 4 ms max.
Contact Bounce — 1.5 ms
Dielectric Strength —
500 volts rms at sea level;
350 volts rms at 70,000 feet and above
Insulation Resistance —
1,000 megohms min. over temperature
range
Environmental Characteristics
Vibration — 30 G, 55 to 3,000 Hz
Shock — 150 G at 11 ms
Temperature — -65°C to +125°C
See page 1-62 for Mounting Forms,
Terminals and Circuit Diagrams.
*Values listed are factory test and inspection values. User should allow for meter variations.
†Applicable over the operating temperature range in circulating air.
Ordering Instructions
Type 3SBM relays can be ordered by
specifying the correct catalog number. This number is derived by
choosing the proper CODE for each
of the six relay characteristics in the
order in which the codes are listed.
Example: The relay selected in
this example is a dual coil, current
calibrated, four-hole end bracket
mounting, solder hook header, 37
ohms coil resistance, and 180 mW
sensitivity. By choosing the proper
code for each of these relay characteristics, the catalog number is
identified as 3SBM6131N2. The
letter R following sensitivity code
indicates relay received 5000 operation miss-test. Ex. 3SBM6131N2R.
* The part number example shown on this page is for catalog items. For a list of specific QPL part numbers, please see the index in Section 15.
1–60
Catalog 5-1773450-5
Revised 3-13
www.te.com
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
Dimensions are in millimeters
unless otherwise specified.
USA: +1 800 522 6752
Asia Pacific: +86 0 400 820 6015
UK: +44 800 267 666
For additional support numbers
please visit www.te.com
CII Low Signal Relays
Four Pole, Magnetic Latching, 2 Amps and Less (Continued)
capabilities of the 3SBM as
well as the memory feature
of the latching function are
both maintained.
Electrical Characteristics
Product Facts
n
Low profile… only 0.32
inches high
n
Suitable for pulse operation
n
Qualified to MIL-R-39016/35
n
Qualified to MIL-R-39016/36
The dual coil version of the
3SBM magnetic latching
relay is now available with
coil transient suppression
with or without blocking
diodes for reverse polarity
protection. This hybrid
magnetic latching relay is
an addition to the growing
family of .150 grid relays.
The diode method is
employed to limit the back
EMF generated when the
coil circuit is opened in
order to protect other circuit
components such as semiconductors. The contact load
Contact Arrangement—
4-pole double-throw (4C)
Operate Sensitivity—
Single-coil form, 100 mW,
Dual-coil form, 180 mW per coil
Contact Ratings —
DC resistive — 2 amps at 28 volts
DC inductive — 0.5 amp at 28 volts,
200 mH
AC resistive — 0.5 amp at 115 volts
(enclosure isolated from ground, or
enclosure and movable contact at same
potential)
AC — 0.125 amp at 115 volts
(enclosure at line potential with respect
to movable contact)
Low-level — 50 µA at 50 mV
Peak AC or DC
Contact Resistance —
0.050 ohms max.;
0.150 ohms after life test
Life — 100,000 operations at rated
loads listed; 1,000,000 operations at
low-level loads
Operating Characteristics
Operate Time — 4 ms max.
Release Time — 4 ms max.
Contact Bounce — 1.5 ms
Dielectric Strength (Note 1) —
500 volts rms at sea level;
350 volts rms at 70,000 feet and above
Insulation Resistance (Note 1) —
1,000 megohms min. over temperature
range
1
CII Low Signal Relays
.150 Grid-space Hybrid
Magnetic Latching Relays
Single Diode, Dual Diode
Type 3SBM (4PDT)
Environmental Characteristics
Vibration — 30 G, 55 to 3,000 Hz
Shock — 150 G at 11 ms
Temperature — -65°C to +125°C
Semiconductor Characteristics
at 25°C
Max. Negative Transient — 1 volt
Breakdown Voltage — 100 Vdc min.
Max. Leakage Current —
1 µA @ 50 Vdc
Note 1: Tests for dielectric withstanding voltage and insulation
resistance should be made with
“coil terminals” shorted together to
avoid unnecessary electrical stress
to semiconductor elements.
See page 1-62 for Mounting Forms,
Terminals and Circuit Diagrams.
*Values listed are factory test and inspection values. User should allow for meter variations.
†Applicable over the operating temperature range in circulating air.
**Coil resistance cannot be measured by conventional bridge.
Note: See page 1-60 for ordering instructions.
* The part number example shown on this page is for catalog items. For a list of specific QPL part numbers, please see the index in Section 15.
1–61
Catalog 5-1773450-5
Revised 3-13
www.te.com
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
Dimensions are in millimeters
unless otherwise specified.
USA: +1 800 522 6752
Asia Pacific: +86 0 400 820 6015
UK: +44 800 267 666
For additional support numbers
please visit www.te.com
CII Low Signal Relays
Four Pole, Magnetic Latching, 2 Amps and Less (Continued)
Mounting Forms (3SBM)
(Vibration note with each
form is acceleration from
55 to 3000 Hz)
Header Types
Header and Connection
Diagrams
Dual Coil
When the SET coil is pulsed
with plus polarity on the blue
bead, the movable contacts
take the position shown in the
connection diagram. The contacts are transferred when the
RESET coil is pulsed with plus
polarity on the reset terminal. A
new pulse of the SET coil with
plus polarity on the blue bead
will transfer the contacts back.
The contacts can also be transferred by applying a pulse of
opposite polarity to the coil previously pulsed. However, this
method requires slightly more
power than the more normal
form of operation described in
the previous paragraph.
1–62
Catalog 5-1773450-5
Revised 3-13
www.te.com
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
Dimensions are in millimeters
unless otherwise specified.
USA: +1 800 522 6752
Asia Pacific: +86 0 400 820 6015
UK: +44 800 267 666
For additional support numbers
please visit www.te.com
很抱歉,暂时无法提供与“2-1617516-8”相匹配的价格&库存,您可以联系我们找货