108 – 19376
Rev.D 10/sep/2012
Product
Specification
1
SCOPE
1.1 Content
This specification covers the performance, test and quality requirements for the Tyco Electronics High
Speed 8 pairs IO board and cable connector. The cable plug assembly is used to connect the cable to the
board connector.
1.2 Qualification
When tests are performed on subject product, procedures specified in this Product Specification shall be
used. All inspections shall be performed using applicable inspection plan and product drawing.
1.3 Applicable partnumbers
The partnumbers of subject products:
• X-2042847-x
HSIO Cable Plug Assembly
• X-2042853-x
HSIO Board Connector Assembly, version 1 (referred to as BCv1)
• X-1551966-x
HSIO Board Connector Assembly, version 2 (referred to as BCv2)
1.4 Completion
Qualification testing of the HSIO Board Connector Assembly version 1 has successfully been completed
on 20JUL2011 and is reported in Qualification Test Report with number 501-19154. This documentation
is on file and available from Engineering Practices and Standards (EPS).
Qualification testing of HSIO Board Connector Assembly version 2 is yet to be completed.
2 Applicable Documents
The following documents form a part of this specification to extend specified herein. Unless otherwise
specified, latest edition of the document applies. In the event of conflict between the requirements in this
specification and the product drawing, product drawing shall take precedence. In the event of conflict
between requirements of this specification and referenced documents, this specification shall take
precedence.
2.1 Tyco Documents
501-19154
Test report. Cable/Board High Speed Connector assembly (version 1).
114-19129
Application specification High Speed Cable/Board Connector System.
2.2 Other Documents
IEC 60512
Basic testing procedures and measuring methods for electromechanical components
for electronic equipment.
J. Smits
Tyco Electronics Nederland B.V.
All international rights reserved
TE Connectivity
*Trademark
R6-76 (Rev. 03-00)
DATE 10 sep 2012
T de Boer
This information is confidential and propriety to TE
Connectivity and its worldwide subsidiaries and affiliates.
It may not be disclosed to anyone, other than TE
Connectivity personnel, without written authorization from
TE Connectivity Corporation, Harisburg, Pennsylvania USA
This specification is a controlled document and subject to
change. Contact the Engineering Control Organization for
the latest revision.
DATE 10 sep 2012
1 of 13
LOC H
108-19376
3
Requirements:
3.1 Design and Construction.
Products shall be of design, construction and physical dimensions as specified on the applicable
customer product drawings C-2042847 (Cable-connector), C-2042847 (Board Connector version 1) and
C-1551966 (Board-connector version 2).
3.2 Materials and Finish.
Materials used in the construction of this product shall be as specified on the applicable customer
drawing.
3.3
Ratings
A.
Data-rate (differential)
- 10 Gb/s
B.
Impedance
- 100 ohm
C.
Operating voltage
- 30 Volt DC max.
D.
Current
- 0,5 Amp Max.
E.
Operating temperature
- -55°C to 105°C.
F.
Durability
- 100 cycles.
Rev. D
R6-77 (Rev. 03-00)
Page 2 of 13
108-19376
3.4 Performance and Test Description.
The product is designed to meet mechanical and environmental performance specified in this paragraph
as tested per test sequence specified in paragraph 3.5.
Unless otherwise specified, all tests are performed at ambient environmental conditions per IEC
specification 60068-1 clause 5.3 and are performed with connectors in mated condition.
VISUAL
Performance
Requirements or Severity
3.4.1. Examination of product Meets requirements of product
Drawing and applicable instructions on customer
drawing, instruction sheet, application
specification.
Para
Test Description
Procedures
Visual, dimensional
and
functional per
applicable
inspection plan.
ELECTRICAL
Para
3.4.2
3.4.3
3.4.4
3.4.5
Test Description
Performance
Requirements or Severity
Termination resistance Max. open voltage 20mV.
Board connector –
Max. current 100 mA DC.
Cable connector
All contacts to be measured.
(signal and ground)
Measuring points shall be as indicated in fig.1
Requirement:
30 mΩ max. (Initial; exclusive bulk)
40 mΩ max. (Final; exclusive bulk)
Termination resistance Max. open voltage 20mV.
Board connector –
Max. current 100 mA DC.
Cable connector
Measuring points shall be as indicated in fig 2.
(shield)
Requirement:
Initial: 10 mΩ max.
Final: 20 mΩ max.
Insulation resistance Test voltage 100V DC.
Duration: 1 minute.
Test between adjacent contacts.
Voltage proof
Requirement:
3
10 MΩ min.
Test voltage 300 VDC for adjacent contacts.
Duration 1 minute.
Procedures
In acc. With
IEC 60512-2-1
In acc. With
IEC 60512-2-1
In acc. with
IEC 60512-3-1
In acc. with
IEC 60512-4-1
Requirement: no break-down or flash-over
3.4.6
Current temperature
de-rating curve
Rev. D
R6-77 (Rev. 03-00)
Temperature rise: 30°C maximum over ambient
temperature (65°C) at 0,5 A
In acc. with
IEC 60512-5-2 / test
5b
Page 3 of 13
108-19376
Para
MECHANICAL
Performance
Requirements or Severity
Test Description
3.4.10 Signal Contact spring Min. 0,5N
force
3.4.11 Shielding Contact
Min. 2,5N
spring force
(outside springs on
BCv1)
3.4.12 Shielding Contact
spring force
Min. 2,5N at A=0,25mm
(see figure 3)
(outside springs on
BCv2)
3.4.13 Shielding Contact
spring force
Min. 1,0N at B=0,25mm
(see figure 4)
(inside-bended springs
on board connector
version 2)
3.4.14 Vibration
10-500 Hz sweeping
1 oct./min., displacement 0,75mm peak/accel. 10
g , 30 minutes in each of 3 mutual perpendicular
axes.
3.4.15 Physical shock
3.4.16 Insertion-force during
wrong polarization.
3.4.17 Mate / un-mate force
without latch.
3.4.18 Mechanical operation
(Inclusive latch)
Rev. D
R6-77 (Rev. 03-00)
Requirement:
No Physical damage.
No discontinuity > 1 µsec.
Subject connector to 50 g half sine shock pulses of
11 ms duration.
6 shocks in two directions of 3 mutual
perpendicular axes.
Apply 100 N straight force at the cable connector
(placed upside down) in mating direction during 10
sec.
Requirement:
No functional damaging and no electrical
contacting on signal-traces.
Mate and un-mate connector-pair.
Speed: 2 mm/sec. rest 30 sec min.
Requirement:
Total mating force 50 N max.
Total un-mating force 10 N min to 40 N max.
Mate and un-mate specimens for 100 cycles at a
maximum rate of 500 cycles per hour with cage
latch operable at room conditions.
Procedures
At deflection of 0.165
mm.
At deflection: till Board
connector shield
At required deflection
to reach dimension A
(see figure 3).
Maximum deflection
to be applied:
A=0,15mm.
At required deflection
to reach dimension B
(see figure 5).
Maximum deflection
to be applied:
B=0,15mm.
In acc. with
IEC 60068-2-6
In acc. with
IEC 60512-6-3
In acc. with
IEC 60512-15-1
In acc. with
IEC 60512-13-2
In acc. With
IEC 60512-9-1
Page 4 of 13
108-19376
3.4.19 Side-load in 4
directions (up-downright-left).
Cable connector mated on board connector.
In acc. with
IEC 60512-17-3
BCv1: Apply 40 N on cable-connector in every
direction (individually) (at 27mm from edge of pcb),
during 10 sec. (see figure 5)
BCv2: Apply 60 N on cable-connector in every
direction (individually) (at 27mm from edge of pcb),
during 10 sec. (see figure 5)
Requirement:
No functional damage, latch should be in place.
3.4.21 Locking latch strength Apply 100 N straight force at the mated cable
connector, in un-mating direction.
3.4.22 Rotational pull force
Load cabled module into board-connector. Apply
an axial pull-force of 60N on the cable, the pull(not applicable for
force will be in a 33 degrees angle with the axial
BCv1)
direction of the connector. Rotate the load 3 full
rotations (1080 degrees) with respect to the axial
direction of the connector.
In acc. with
IEC 60512-15-1
Requirement:
plug shall remain mated with no evidence of
housing damage.
3.4.23 Mounting-force board- Measure force necessary to push the boardconnector.
connector into the host board at a maximum rate
of 12.7mm per minute.
(not applicable for
BCv1)
Requirement:
20N maximum.
SIGNAL INTEGRITY
Para Test Description
3.4.30 Characteristic
Impedance
3.4.31 Skew
Rev. D
R6-77 (Rev. 03-00)
Performance
Procedures
Requirements or Severity
Time Domain (TDR) measurement
IEC 60512-25-7
Impedance profile : the test board, PCB cable connector
and 1000ps cable
Rise-time of incident pulse :
30ps (10%-90%)
Pairs 15-16 and 18-19
Requirement :
100 Ω +/- 10%; 100 Ω -20% for footprint for time period
of 250ps
Time Domain (TDT) measurement
IEC 60512-25-4
Risetime of incident pulse:
30ps (10%-90%)
Pairs 15-16 and 18-19
Samples :
1m and 8m
Requirement : 15ps
Page 5 of 13
108-19376
3.4.32 Return Loss
Frequency Domain (FDR) S-parameter measurement
Pairs 15-16 and 18-19
Samples :
1m with AWG26
Requirement :
IEEE 802.3ap for 10GBaseKR -3dB.
3.4.33 Insertion Loss
3.4.34 Cross Talk
Frequency Domain (FDT) S-parameter measurement
Pairs 15-16 and 18-19
Samples :
1m, 4m and 8m with AWG26
Requirement :
§ IEEE 802.3ap for 10GBaseKR
§ 1.1dB/GHz -0.5dB @ 1GHz to 5GHz for 1m with
AWG26
§ Suck out frequency (resonance)
> 8GHz
Frequency Domain (FDT) S-parameter measurement
Samples :
1m, 4m, 8m with AWG26
Requirement on 1m:
Pairs 15-16 and 18-19
- NEXT < -30dB up to 1GHz.
All pairs
- Power sum NEXT and FEXT
< -24dB up to 1GHz.
3.4.35 Insertion Loss to Frequency Domain (FDT) S-parameter measurement
Cross Talk Ratio Pairs 15-16 and 18-19
over 10Gbps link Samples :
1m, 4m and 8m with AWG26
3.4.36 Screening
Attenuation
Requirement :
Samples 1m and 4m
- IEEE 802.3ap for 10GBaseKR
Samples 8m
- < -55dB up to 100MHz
- < -36dB up to 1GHz
- < -28dB up to 2.5GHz
- < -23dB up to 5.0GHz
Samples :
1m with AWG26
Requirement :
< -40dB at 0 to 5GHz for cable assembly and PCB
connector
3.4.37 Time Delay Rx to Max 400ps asymmetry between pairs (Rx - Tx)
Tx
Rev. D
R6-77 (Rev. 03-00)
IEC 60512-25-5
Reference :
IEEE Std 802.3ap2007 – Amendment to
IEEE Std 802.32005:CSMA/CD –
Annex 69B
IEC 60512-25-5
Reference :
IEEE Std 802.3ap2007 – Amendment to
IEEE Std 802.32005:CSMA/CD –
Annex 69B
IEC 60512-25-1
Calculated values
based on 3.4.11 and
3.4.12
IEC 62153-4-4 and
IEC 62153-4-7
Measurements to be
performed on 1m and
8m cable assemblies
Page 6 of 13
108-19376
Para
Test Description
3.4.40 Rapid change of
Temperature
3.4.41 Climatic sequence
Dry heat
st
1 Damp heat cycle
Cold
2nd Damp heat cycle
3.4.42 Damp/heat steady
state
3.4.43 Temperature life.
3.4.44 Corrosion mixed
flowing gas
3.4.45 Resistance to
soldering heat board
connector
Rev. D
R6-77 (Rev. 03-00)
ENVIRONMENTAL
Performance
Requirements or Severity
-40°/90°C, 0,5 hrs / 0,5 hrs,
5 cycles
90°C, 16 hrs
25°/55°C, RH 93%, 24 hrs
-40°C, 2 hrs
25°/55°C, RH 93%, 24 hrs
Temperature 40°C, RH 93%,
Duration: 21 days
Subject mated specimens to 105°C for 240 hours
without electrical load.
Temperature 25°C, RH 75%,
Cl2 10 ppb, NO2 200 ppb, H2S 10 ppb,
SO2 200 ppb.
Duration: 20 days (un-mated)
Specimens were subject to the following reflow
profile. Fig 6
Procedures
In acc. with
IEC 60512-11-4
In acc. with
IEC 60512-11-1
In acc. with
IEC 60512-11-3
In acc. with
IEC 60512-11-9
In acc. with
IEC 60512-11-7
Tyco 109-201,
method C
Page 7 of 13
108-19376
Ω
Figure 1
Figure 2
Rev. D
R6-77 (Rev. 03-00)
Page 8 of 13
108-19376
Figure 3
Figure 4
Rev. D
R6-77 (Rev. 03-00)
Page 9 of 13
108-19376
Figure 5
300
260
250
deg C
200
150
100
50
0
0
30 60 90 120 150 180 210 240 270 300 330 360
sec
Figure 6
Rev. D
R6-77 (Rev. 03-00)
Page 10 of 13
108-19376
3.5
Product Qualification and Requalification Test Sequence
3.5.1 Test sequence applicable for Board Connector version 1
Rev. D
R6-77 (Rev. 03-00)
Page 11 of 13
108-19376
3.5.2 Test sequence applicable for HSIO Board Connector version 2
Rev. D
R6-77 (Rev. 03-00)
Page 12 of 13
108-19376
4
QUALITY ASSURANCE PROVISIONS.
4.1
Qualification Testing.
Sample Selection.
Samples shall be prepared in accordance with applicable instructions and shall be selected random from
current production.
Unless details to perform test require otherwise, plugs shall be terminated on cables according to
applicable instructions and requirements specified in appropriate Application Specification and Instruction
Sheet.
Unless otherwise specified all test groups shall consist of a minimum of 5 connectors of applicable type.
Qualification inspection shall be verified by testing samples as specified in Para 3.5.
4.2 Requalification Testing.
If changes significantly affecting form, fit or function are made to product or manufacturing process,
product assurance shall coordinate re-qualification testing, consisting of all or part of original testing
sequence as determined by product, quality and reliability engineering.
4.3 Acceptance.
Acceptance is based on verification that product meets requirements of Para 3.4. Failures attributed to
equipment, test set-up, test sub-components or operator deficiencies shall not disqualify the product.
When product failure occurs, corrective action shall be taken and samples resubmitted for qualification.
Testing to confirm corrective action is required before re-submittal.
4.4 Quality Conformance Inspection.
Applicable TYCO Electronics quality inspection plan will specify sampling acceptable quality level to be
used. Dimensional and functional requirements shall be in accordance with applicable product drawing
and this specification.
Rev. D
R6-77 (Rev. 03-00)