SCHRACK FORCE GUIDED RELAYS
For safety solutions
SCHRACK Force Guided Relays are used in safety circuits in combination with light curtains,
interlock switches, and emergency stop switches to control outputs. In the design of the Force
Guided Relays, special importance was attached to the switching of low loads by the monitoring
circuit. TE Connectivity (TE) has developed comprehensive documentation of Forced Guided
Relays which supports accelerating the development process for safety controls and application
notes help to point out possible error sources.
CREDIBILITY & RELIABILITY
INDUSTRY 4.0
•
Established in the relay market for 20 years
•
High volume manufacturing
•
Innovators in replacing contactors in safety
circuits
•
Virtually fully automated
packing improves traceability
INDUSTRY STANDARDS
EASE DESIGN-IN PROCESS & SUPPORT
& CERTIFICATIONS
•
TE has developed special procedures
to provide contact reliability
•
Comprehensive documentation accelerates
the development process for safety controls
•
CCC, UL, TUV & VDE*
•
Sealed against external influences
according to IEC
•
IEC 61810-3 protection category RTIII
*for exact product approvals please refer
to the individual product group data sheet
INDUSTRIAL / SCHRACK FORCE GUIDED RELAYS
2
TE has extensive capabilities in the design and manufacturing of relays and a broad portfolio of switching solutions for
demanding, high performance applications. These relay products are remotely actuated to control electrical power flow by
either interrupting or completing an electrical circuit.
In many safety critical applications only a special version of an electro mechanical relay can be used, a Force Guided Relays,
according to IEC 61810-3. The special design connects NC (normally closed) and NO (normally open) contacts through an
actuator, so that one contact interacts with all the other contacts during switching operation in a planned, forced manner.
The ultimate goal is, in case of contact welding or other potential failure modes of the relay, to enable a minimum of 0.5 mm
(0.20 inch) contact gap of the antivalent contacts – in other words, NO and NC contacts can never be closed at the same
time throughout the whole life cycle of the relay and allow operations to switch into a safe state.
TE’s SCHRACK Force Guided Relays are essential for safety control applications and help protect people’s lives & health
when danger needs to be addressed in applications.
FOCUS APPLICATIONS:
•
Machine safety such as presses, cutting machines and robot controls
•
Building automation such as elevator, escalator and door controls
•
Railway such as signaling, break controls, level crossings controls
•
Medical devices such as x-ray, ventilation and diagnostic systems
Safety is
paramount
for human beings
in all areas of our
daily lives.
WORKPLACE
INFRASTRUCTURE
PRIVATE SECTOR
Watch the SCHRACK Force Guided Relays Webinar on TE.com
INDUSTRIAL / SCHRACK FORCE GUIDED RELAYS
3
3
SCHRACK Force Guided Relays
For safety solutions
The SCHRACK portfolio of Force Guided Relays meets the superior requirements towards quality and lifetime of a Force
Guided Relays.
TE’S FORCE GUIDED RELAYS PORTFOLIO OFFERS FLEXIBLE DESIGN OPTIONS SUCH AS:
•
Multiple contact configurations up to 5 NO (form A) and
up to 3 NC (form B) in different form factors
•
Standard and sensitive coil options for longer lifetime
and improved heat dissipation
•
Different plating options such as standard plating
AgSnO2 or high-performance gold plating AgSnO2 + 0.2
μm Au
•
Different packaging options such as box packaging and
•
Different pin layouts and version with selective contact
loading to enable higher voltage ratings
2
pole
SR2
1NO/1NC or
2 CO contacts
PCB and socket
mount version
4
pole
SR4
3NO/1NC or
2NO/2NC contacts
16.5 mm height
tube packaging
Being one of the leading manufacturers of Force Guided
Relays globally, our standard products are compliant to UL,
CSA, VDE, TÜV and CCC regulation (please see details per
family for exact approvals).
4&6
7
pole
SR6
6 poles (3 contact
versions) or 4 poles
for extended isolation
15.7 mm height
pole
SRL7
6NO / 1NC contacts
10.7 mm height
Check out free samples on www.te.com/usa-en/utilities/te-digital-resources/how-to-order-samples.html
INDUSTRIAL / SCHRACK FORCE GUIDED RELAYS
4
Contents
SCHRACK SR2
............................................................................................................................. 6
SCHRACK SR2 PLUG-IN & ACCESSORIES
............................................................................................................................. 7
SCHRACK SR4
............................................................................................................................. 8
SCHRACK SR6 WITH 4 CONTACTS
............................................................................................................................. 9
SCHRACK SR6 WITH 6 CONTACTS
........................................................................................................................... 10
SCHRACK SRL7
............................................................................................................................. 11
INDUSTRIAL / SCHRACK FORCE GUIDED RELAYS
5
5
SCHRACK Force Guided Relays
For safety solutions
SCHRACK SR2
SCHRACK SR2 Force Guided Relays offer high endurance with reinforced insulation between
all adjacent contacts for loads up to 6A. The SR2 family offers a 2-pole contact arrangement
with either 1 NO (form A) + 1 NC (form B) contact set or 2 CO (form C) contact set with Force
Guided Relays contacts according to IEC 61810-3. The robust and slim footprint of 12.6 mm
allows economic usage, if the application requires dense stacked relay design and reinforced
insulation at the same time.
FEATURES
APPLICATIONS
•
2 pole relay with force guided contacts according
to IEC 61810-3
•
Emergency shut-off
•
Press control
•
Reinforced insulation between poles
•
Machine control
•
Elevator and escalator control
CONTACT DATA
•
Contact arrangement:
1 form A (NO) + 1 form B (NC) IEC 61810-3 type A
2 form C (CO)
IEC 61810-3 type B
•
Rated voltage:
250 VAC
•
Rated current:
6A
•
Contact material:
AgNi
•
Min. recommended
contact load:
INSULATION DATA
•
•
Initial dielectric strength
- between open contacts:
- between contact and coil:
- between adjacent contacts:
1500 Vrms
4000 Vrms
3000 Vrms
Clearance/creepage
between contact and coil:
≥8/8 mm
5 V/10 mA
OTHER DATA
COIL DATA
•
Magnetic system:
DC
•
Rated coil voltage:
5 to 110 VDC
•
Rated coil power:
700 mW
•
Ambient temperature (max.):
+70°C
•
Mounting and terminal type:
PCB, THT
PRODUCT INFORMATION
Product Code
Coil voltage
Contact Arrangement
Part Number
V23047-A1024-A501
24V
2 form C (CO)
1-1393258-5
V23047-A1021-A501
21V
2 form C (CO)
1-1393258-1
V23047-A1024-A511
24V
1 NO (form A) + 1 NC (form B)
1-1393258-7
V23047-A1012-A501
12V
2 form C (CO)
1393258-4
V23047-A1110-A501
110V
2 form C (CO)
1-1415012-1
For additional configurations, see the Data Sheet - SCHRACK SR2
INDUSTRIAL / SCHRACK FORCE GUIDED RELAYS
6
SCHRACK Force Guided Relays
For safety solutions
SCHRACK SR2 PLUG-IN & ACCESSORIES
DIN rail mountable sockets for the SCHRACK SR2 2 pole Force Guided Relays allow quick
changeover if required. Time efficient spring clamp wire connection and robust screw clamp
wire connection available for high flexibility. White snap on marking tabs and virtually tool-less
mounting clips save installer most important asset – their time.
FEATURES
APPLICATIONS
•
2 pole relay with force guided contacts according
to IEC 61810-3
•
Emergency shut-off
•
Press control
•
Version for use in sockets
•
Machine control
•
Elevator and escalator control
CONTACT DATA
•
Contact arrangement:
1 form A (NO) + 1 form B (NC) IEC 61810-3 type A
2 form C (CO)
IEC 61810-3 type B
•
Rated voltage:
250 VAC
•
Rated current:
6A
•
Contact material:
AgNi
•
Min. recommended
contact load:
INSULATION DATA
•
•
Initial dielectric strength
- between open contacts:
- between contact and coil:
- between adjacent contacts:
1000 Vrms
4000 Vrms
2500 Vrms
Clearance/creepage
between contact and coil:
≥8/8 mm
5 V/10 mA
OTHER DATA
COIL DATA
•
Magnetic system:
DC
•
Rated coil voltage:
5 to 110 VDC
•
Rated coil power:
700 mW
•
Ambient temperature (max.):
+70°C
•
Mounting and terminal type:
DIN rail or
PCB socket
PRODUCT SELECTION INFORMATION
Product Code
Coil voltage
V23047-P1012-A501
12 V
V23047-P1024-A501
24 V
Contact Arrangement
2 Form C (CO)
Part Number
7-1415543-6
7-1415543-8
For additional configurations, see Schrack SR2 Plug-in and SR2 Plug-in Accessories
INDUSTRIAL
7
/ SCHRACK FORCE GUIDED RELAYS
7
SCHRACK Force Guided Relays
For safety solutions
SCHRACK SR4
SCHRACK SR4 Force Guided Relays is compact and space efficient for loads up to 8 A. The
SR4 family offers a 4-pole contact arrangement with either 3 NO (form A) + 1 NC (form B)
contact set or 2 NO (form A) + 2 NC (form B) contact set with Force Guided Relays contacts
according to IEC 61810-3. The optimized ratio between 13 mm width and 16.5 mm height
allows miniaturization for horizontally or vertically installed PCBs and modules.
FEATURES
APPLICATIONS
•
4 pole relay with force guided contacts according
to IEC 61810-3
•
Emergency shut-off
•
Press control
•
Compact design, space efficient
•
Machine control
•
Elevator and escalator control
CONTACT DATA
•
Contact arrangement:
3 form A + 1 form B
(3 NO + 1 NC) and 2 form
A + 2 form B (2 NO + 2 NC)
•
Rated voltage:
250 VAC
•
Rated current:
8A
•
Contact material:
AgSnO2
•
Min. recommended
contact load:
INSULATION DATA
•
•
Initial dielectric strength
- between open contacts:
- between contact and coil:
- between adjacent contacts:
1500 Vrms
4000 Vrms
2500 Vrms
Clearance/creepage
between contact and coil:
≥10/10 mm
5 V/10 mA
OTHER DATA
COIL DATA
•
Magnetic system:
DC
•
Rated coil voltage:
5 to 110 VDC
•
Rated coil power:
800 mW
•
Ambient temperature (max.):
+70°C
•
Mounting and terminal type:
PCB, THT
PRODUCT INFORMATION
Product Code
SR4D4012
Coil voltage
Contact Arrangement
12 V
SR4D4018
18 V
Part Number
1415055-1
2 form A + 2 form B
(2 NO + 2 NC)
1-1415055-1
SR4D4024
24 V
3-1415055-1
SR4M4012
12 V
8-1415053-1
SR4M4018
18 V
SR4M4024
24 V
3 form A + 1 form B
(3 NO + 1 NC)
9-1415053-1
4-1415053-1
For additional configurations, see the Data Sheet - SCHRACK SR4
INDUSTRIAL / SCHRACK FORCE GUIDED RELAYS
8
SCHRACK Force Guided Relays
For safety solutions
SCHRACK SR6 WITH 4 CONTACTS
If reinforced insulation between all adjacent contacts is a must. The SCHRACK SR6 Force
Guided Relays family offers a 4-pole contact arrangement with either 3 NO (form A) + 1
NC (form B) contact set or 2 NO (form A) + 2 NC (form B) contact set with Force Guided
Relays contacts according to IEC 61810-3. Reinforced insulation of up to 4000 V between
selectively loaded, adjacent contacts – in addition to the reinforced insulation between coil
and contact.
FEATURES
APPLICATIONS
•
4 pole relay with force guided contacts according
to IEC 61810-3
•
Emergency shut-off
•
Press control
•
High insulation distances between electrical circuits
•
Machine control
•
Elevator and escalator control
CONTACT DATA
•
Contact arrangement:
3 form A + 1 form B
(3 NO + 1 NC) and 2 form
A + 2 form B (2 NO + 2 NC)
•
Rated voltage:
250 VAC
•
Rated current:
8A
•
Contact material:
AgSnO2
•
Min. recommended
contact load:
INSULATION DATA
•
•
Initial dielectric strength
- between open contacts:
- between contact and coil:
- between adjacent contacts:
1500 Vrms
4000 Vrms
3000/4000 Vrms
Clearance/creepage
between contact and coil:
≥5.5/5.5 mm
5 V/10 mA
OTHER DATA
COIL DATA
•
Magnetic system:
DC
•
Rated coil voltage:
5 to 110 VDC
•
Rated coil power:
550 mW white cover
1200 mW transparent cover
•
Ambient temperature (max.):
+85°C white cover
+70°C transparent cover
•
Mounting and terminal type:
PCB, THT
PRODUCT INFORMATION
Product Code
Coil voltage
Coil power / cover
SR6-223-U024
24 V
SR6-223-U110
110 V
550 mW
non transparent cover
SR6D4024
24 V
SR6D4110
110 V
SR6-313-U024
24 V
SR6-313-U048
48 V
SR6M4024
24 V
SR6M4048
48 V
1200 mW
transparent cover
550 mW
non transparent cover
1200 mW
transparent cover
Contact Arrangement
Part Number
1558740-8
2 Form A (NO) + 2
Form B (NC)
1-1558740-5
6-1415027-1
1415062-1
1558741-8
3 Form A (NO) + 1
Form B (NC)
1-1558741-2
3-1415353-1
1-1415544-5
For additional configurations, see the Data Sheet - SCHRACK SR6 with 4 contacts
INDUSTRIAL
9
/ SCHRACK FORCE GUIDED RELAYS
9
SCHRACK Force Guided Relays
For safety solutions
SCHRACK SR6 WITH 6 CONTACTS
Our most versatile relay type for design-in flexibility for loads up to 8 A. SCHRACK SR6
Force Guided Relays family offers a 6-pole contact arrangement with either 3 NO (form A)
+ 3 NC (form B) contact set, 4 NO (form A) + 2 NC (form B) contact set or 5 NO (form A)
+ 1 NC (form B) contact set with Force Guided Relays contacts according to IEC 61810-3.
Sensitive versions with low coil power consumption of only 700 mW approximately, enables
excellent low temperature to increase and support lifetime.
FEATURES
APPLICATIONS
•
6 pole relay with force guided contacts according
to IEC 61810-3
•
Emergency shut-off
•
Press control
•
Reinforced insulation between all contacts
•
Machine control
•
Elevator and escalator control
CONTACT DATA
•
Contact arrangement:
3 form A + 3 form B
(3 NO + 3 NC), 4 form
A + 2 form B (4 NO + 2 NC)
and 5 form A + 1 form B
(5 NO + 1 NC)
•
Rated voltage:
250 VAC
•
Rated current:
8A
•
Contact material:
AgSnO2
•
Min. recommended
contact load:
5 V/10 mA
INSULATION DATA
•
Initial dielectric strength
- between open contacts:
1500 Vrms
- between contact and coil:
4000 Vrms
- between adjacent contacts: 3000 Vrms
•
Clearance/creepage between
contact and coil:
≥5.5/5.5 mm
OTHER DATA
COIL DATA
•
Magnetic system:
DC
•
Rated coil voltage:
5 to 110 VDC
•
Rated coil power:
1200 mW/800 mW or 700 mW
•
Ambient temperature (max.): +85°C white cover
+70°C transparent cover
•
Mounting and terminal type:
PCB, THT
PRODUCT INFORMATION
Product Code
Coil voltage
Coil power / cover
SR6-333-L012
12 V
SR6-333-L024
24 V
700 mW
non transparent cover
SR6A4024
24 V
SR6A4110
110 V
SR6-426-L012
12 V
SR6-426-L018
18 V
SR6-426-L021
21 V
SR6-423-L110
110 V
SR6B4024
24 V
SR6B4110
110 V
SR6-516-L012
12 V
SR6-513-L024
24 V
SR6-513-L110
110 V
SR6C4024
24 V
1200 mW
transparent cover
Contact Arrangement
Part Number
1558736-4
3 Form A (NO) + 3
Form B (NC)
1558736-8
1415015-1
9-1415018-1
2-1558737-4
700 mW
non transparent cover
2-1558737-6
4 Form A (NO) + 2
Form B (NC)
1200 mW
transparent cover
1-1558737-5
1393260-7
1200 mW
transparent cover
700 mW
non transparent cover
2-1558737-7
1-1393260-3
2-1558738-4
5 Form A (NO) + 1
Form B (NC)
1558738-8
1-1558738-5
1415017-1
For additional configurations, see the Data Sheet - SCHRACK SR6
INDUSTRIAL / SCHRACK FORCE GUIDED RELAYS
10
SCHRACK Force Guided Relays
For safety solutions
SCHRACK SRL7
The flattest version of a TE Force Guided Relays with only 10.8 mm height for loads up to 6 A.
SCHRACK SRL7 family offers a 7-pole contact arrangement with 5 NO (form A) + 2 NC (form B)
contact set with Force Guided Relays contacts according to IEC 61810-3. With an overall height
of only 10.7 mm the 7-pole relay belongs to the flattest Force Guided Relays. The low profile is
highly reliable for the realization of compact safety modules (overall width of only 17.5 mm), but
also wherever there is little space for installation height. The low coil power consumption of only
700 mW enable excellent low temperature to increase and expand the usage of this relay from
70°C now up to 85°C ambient temperature condition.
FEATURES
APPLICATIONS
•
Low profile relay with force guided contacts according
to IEC 61810-3
•
Safety modules
•
Process technology
•
5 form A (NO) + 2 form B (NC) contacts
•
Elevator and escalator control
•
Reinforced insulation between contact circuits
•
Emergency shut-off
•
Remote control
•
Robotics
•
Machine tools
CONTACT DATA
•
Contact arrangement: 5 form A + 2 form B contacts
(5 NO + 2 NC)
•
Rated voltage:
250 VAC
•
Rated current:
6A
•
Contact material:
Ag alloy
•
Min. recommended
contact load:
5 V/10 mA
INSULATION DATA
•
Initial dielectric strength
- between open contacts:
1000 Vrms 1000 Vrms
- between contact and coil:
4000 Vrms 2500 Vrms
- between adjacent contacts: 4000 Vrms 2500 Vrms
•
Clearance/creepage between
contact and coil:
COIL DATA
•
Coil voltage range:
5 to 110 VDC
•
Operative range:
IEC 61810-2
•
Max. coil power:
700 mW
≥5.5/5.5 mm ≥3/4 mm
OTHER DATA
•
Ambient temperature (max.): -40°C to 85°C
•
Mounting and terminal type:
PCB, THT
PRODUCT SELECTION INFORMATION
Product Code
Coil voltage
SRL7-523-D012
12 V
SRL7-523-D021
21 V
SRL7-523-D024
24 V
Contact Arrangement
Part Number
2045880-4
5 form A + 2 form B
2045880-7
2045880-8
For additional configurations, see the Data Sheet - SCHRACK SRL7
INDUSTRIAL / SCHRACK FORCE GUIDED RELAYS
11
11
Connect With Us
We make it easy to connect with our experts and we are ready to provide the support you need.
Visit te.com/FGR for more Force Guided Relays products information.
te.com
© 2023 TE Connectivity. All Rights Reserved.
TE, TE Connectivity, TE connectivity (logo), EVERY CONNECTION COUNTS, and SCHRACK are trademarks owned or licensed by the TE Connectivity Ltd. family of
companies. Other product names, logos, and company names mentioned herein may be trademarks of their respective owners.
While TE has made every reasonable effort to ensure the accuracy of the information in this document, TE does not guarantee that it is error-free, nor does TE
make any other representation, warranty or guarantee that the information is accurate, correct, reliable or current. TE reserves the right to make any changes to the
information contained herein without prior notice. TE Connectivity assumes only those obligations set forth in the terms and conditions for this product and shall in
no event be liable for any incidental, indirect, or consequential damages arising out of the sale, resale, use, or misapplication of the product. TE expressly disclaims
any implied warranties with respect to the information contained herein, including, but not limited to, implied warranties of merchantability or fitness for a particular
purpose. Dimensions, specifications and/or information contained herein are for reference purposes only and are subject to change without notice. Consult TE for
the latest dimensions, specifications and/or information. Users of TE Connectivity products must make their own assessment as to whether the respective product
is suitable for the respective desired application.
11/23
INDUSTRIAL / SCHRACK FORCE GUIDED RELAYS