0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
2150035-2

2150035-2

  • 厂商:

    HUMIREL(泰科)

  • 封装:

    -

  • 描述:

    OC-AT-E-FA-080F130F-001-0054

  • 数据手册
  • 价格&库存
2150035-2 数据手册
7 8 THIS DRAWING IS UNPUBLISHED. C COPYRIGHT 20 PART NUMBER RELEASED FOR PUBLICATION REVISION D 7-2150035-2 D 7- 2150035 -7 A 5 4 3 2 20 LOC ALL RIGHTS RESERVED. BY TYCO ELECTRONICS CORPORATION. 2150035 -2 6 DESCRIPTION FEED TYPE FINE CRIMP HEIGHT ADJUST A ATLANTIC VERSION TERMINATOR INTERFACE ADAPTER 1 REVISIONS DIST 66 P LTR PNEUMATIC PNEUMATIC AND CRIMP TOOLING KIT DESCRIPTION DATE DWN APVD A RELEASED 08FEB2013 LG TE B ECR-18-016633 21OCT2018 TB TE C ECR-21-005092 05MAY2021 JWC RK D ECR-21-007118 02AUG2021 JWC TE PNEUMATIC CRIMP TOOLING KIT - D D CRIMP WIRE INSUL APPLICATOR DATA SIZE TYPE F F 2.03 mm [.080] 3.30 mm [.130] APPL INSTRUCTIONS 408-35043 TE TERMINAL TERMINAL DATA: TE CRIMP SPECIFICATION .250 SERIES FASTIN FASTON TAB CONNECTOR TERMINAL NAME: WIRE STRIP LENGTH n 5.20-5.80 mm [.205-.228 IN] C TERMINAL APPLICATION SPECIFICATION 114-20119 - TERMINALS APPLIED TE TERMINAL 293041-1 WIRE SIZE 1.00mm2 0.75mm2 0.50mm2 0.35mm2 B 1 2 3 4 5 293041-2 C1__DWG_PN_1_1 2.30mm MAX [.091 IN MAX] - - - - C1__DWG_PN_2_0 TE TERMINAL C1__DWG_PN_2_1 1-293041-1 W1__DWG_WGAUGE_2 W1__DWG_WGAUGE_3 W1__DWG_WGAUGE_4 1.40+/-0.03 [.055+/-.001] 1.35+/-0.03 [.053+/-.001] 1.30+/-0.03 [.051+/-.001] 1.25+/-0.03 [.049+/-.001] C1__DWG_PN_3_0 C1__DWG_PN_3_1 TE TERMINAL W1__DWG_CRIMP_HT_1 W1__DWG_CRIMP_HT_2 W1__DWG_CRIMP_HT_3 W1__DWG_CRIMP_HT_4 C1__DWG_PN_4_0 1-293041-2 CRIMP HEIGHT REFERENCE SETTING CRIMP HEIGHT mm [INCH] W1__DWG_WGAUGE_1 3 5 TE TERMINAL C1__DWG_PN_1_0 INSULATION DIAMETER RANGE 5.4 5.8 6.3 6.8 RECOMMENDED SPARE PARTS REFER TO SUPPLIED INSTRUCTION SHEET FOR CLEANING, LUBRICATION AND STORAGE OF APPLICATOR. APPLY PART NUMBER 2-23419-6 LOCTITE TO THREADS OF ITEM 242. CRIMP HEIGHT REFERENCE SETTING WAS THE SETTING USED WHEN THE APPLICATOR WAS QUALIFIED AT THE FACTORY. ADJUSTMENT MAY BE NECESSARY WHEN RUNNING APPLICATOR IN THE FIELD. TERMINAL PITCH NOT COMPATIBLE WITH MECHANICAL FEED. C1__DWG_PN_4_1 4 W1__FA_SETTING_1 W1__FA_SETTING_2 W1__FA_SETTING_3 W1__FA_SETTING_4 *WARNING ON INSTALLATION, SET WIRE DISC TO CRIMP HEIGHT REFERENCE SETTING FOR LARGEST WIRE SIZE. CRIMP HEIGHT REFERENCE SETTINGS GREATER THAN THE VALUE SHOWN MAY CAUSE DAMAGE TO THE CRIMP TOOLING. REFER TO THE INSTRUCTION SHEET FOR PROPER SETUP AND ADJUSTMENTS. 6. UNLESS SPECIFIED OTHERWISE TORQUE VALUES SHALL BE USED PER DOCUMENT, 101-35000. 1 1 1 1 1 1 A 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 - REF REF 1 1 1 1 2 2 1 1 2 2 1 1 1 1 4 4 2 2 2 2 2 2 1 1 1 1 1 1 1 1 1 1 8 8 2 2 2 2 1 1 2 2 1 1 2 2 1 1 1 1 1 1 4 4 1 1 1 1 1 1 1 2 1 1 1 1 1 1 1 1 2 1 1 1 1 2 1 2119641-1 2119082-9 2079764-1 2119083-1 2844940-4 1-18028-0 5018030-1 811242-5 690753-2 994970-2 455888-4 1803607-4 2-18032-2 2119740-1 2168078-1 2168083-2 5-18022-5 2168400-4 2168083-9 5018030-1 986965-8 2063961-9 18023-9 2119655-5 1803517-1 1803602-1 1-18028-2 2168083-9 2168083-2 240639-1 1-2168083-5 1752371-5 2-22281-3 1803292-4 1-1901696-2 1-1901695-2 1-2079383-1 3-240641-3 240644-1 690482-6 1333216-8 2217206-4 5-240641-0 238011-2 2-1633961-6 455888-6 2-456405-5 1 1 1 1 1 1 1 1 1 1 1 1 2 1 2 1 1 4 2 2 2 1 1 1 1 1 8 2 2 1 2 1 2 1 1 1 4 1 1 1 1 1 1 1 1 1 1 1 -77 -72 -2 PART NO THIS DRAWING IS A CONTROLLED DOCUMENT FOR TYCO ELECTRONICS CORPORATION IT IS SUBJECT TO CHANGE AND THE CONTROLLING ENGINEERING ORGANIZATION SHOULD BE CONTACTED FOR THE LATEST REVISION. DIMENSIONS: ATLANTIC VERSION Shown on sheets 1 of 4 & 2 of 4 (Pacific version shown on sheets 3 of 4 AMP 4805 REV 31MAR2000 mm & 4 of 4) MATERIAL - TOLERANCES UNLESS OTHERWISE SPECIFIED: - 0 PLC 1 PLC 2 PLC 3 PLC 4 PLC ANGLES FINISH - DWN 10JAN2012 CHK 10JAN2012 APVD 10JAN2012 Y.YIN G.BAILEY S.XI TE Connectivity Harrisburg, PA 17105-3608 NAME - APPLICATION SPEC - WEIGHT SIZE - A1 CAGE CODE 00779 Customer Accessible Production Drawing SHEETS 3 ITEM NO DESCRIPTION PRODUCT SPEC - 248 244 243 242 238 192 190 189 188 164 82 71 70 67 66 60 59 57 56 54 53 51 49 46 44 41 33 31 29 27 25 24 22 20 19 18 17 16 11 10 9 8 7 5 4 3 2 1 FEED CAM, AIR FEED CAM, SNAIL, INSULATION ADJUSTMENT WASHER, WAVE SPRING, CREST-TO-CREST RETAINER, INSULATION DIAL AIR FEED MODULE WASHER, FLAT, REG M8 NUT, HEX, REG, RoHS, M3 BUMPER, HOLD DOWN SPACER, TONKER COUNTER, MAGNETIC SPACER, CRIMPER DOCUMENTATION PACKAGE SCR, SET, FLT PNT, M3 X 10.0 TAG,IDENTIFICATION SCREW, DRIVE, RH, RoHS, 2 x .188 SCR, SKT HD CAP, RoHS, M4 X 8.0 SCR, HEX HD CAP, M4 X 6.0 SHCS, LOW HEAD, RoHS, M4 X 8 SCR, SKT HD CAP, RoHS, M4 X 20 NUT, HEX, REG, RoHS, M3 NUT, LOCK, HEX, TORQUE (M4) FEED FINGER SCR, SKT HD CAP M4 X 6.0 APPLICATOR BASIC ASSEMBLY, EF RAM ASSEMBLY, EF ATLANTIC SCR, BHSC, RoHS (M8 X 25) WASHER, FLAT, REG M4 SCR, SKT HD CAP, RoHS, M4 X 20 SCR, SKT HD CAP, RoHS, M4 X 8.0 STRIPPER (MACHINING) SCR, SKT HD CAP, RoHS, M4 X 30 PLATE, STRIP GUIDE SPRING, COMPRESSION DRAG STRIP GUIDE, REAR STRIP GUIDE, FRONT SCR, BHSC, RoHS (M6 X 12) SPACER PLATE, REAR SHEAR PLATE, FRONT SHEAR ANVIL, COMBINATION BLADE, SLUG SPACER BLOCK, CRIMPER SPACER CRIMPER, INSULATION F PREMIUM SPACER, CRIMPER CRIMPER, WIRE PREMIUM Ocean End Feed Applicator - DRAWING NO 2150035 SCALE 1:1 RESTRICTED TO SHEET 1 OF - 4 & 4 ARE NOT REQUIRED FOR ATLANTIC VERSION REV D C B A 7 8 THIS DRAWING IS UNPUBLISHED. C COPYRIGHT 20 RELEASED FOR PUBLICATION BY TYCO ELECTRONICS CORPORATION. 6 5 4 3 2 20 LOC REVISIONS DIST A ALL RIGHTS RESERVED. 1 66 P LTR DESCRIPTION SEE SHEET 1 - 44 44.61 DATE DWN APVD - - - REF 0.05 D D FEED TYPE 44 RAM SET-UP 243 3 2 56 1 2 7 244 16 188 242 PNEUMATIC 5 238 82 1 190 1 189 A 59 2 C 3 4 C 1 SEE DETAIL A 192 41 51 25 70 FEED SPRING SETTING POSITION 54 A 164 20 2 57 33 DETAIL A 19 67 18 B B 66 CAM POSITION 30mm STROKE 29 248 33 27 8 1 60 46 31 9 1 11 1 17 53 33 22 24 49 A A THIS DRAWING IS A CONTROLLED DOCUMENT FOR TYCO ELECTRONICS CORPORATION IT IS SUBJECT TO CHANGE AND THE CONTROLLING ENGINEERING ORGANIZATION SHOULD BE CONTACTED FOR THE LATEST REVISION. 40mm STROKE AIR FEED AMP 4805 REV 31MAR2000 DIMENSIONS: ATLANTIC VERSION Shown on sheets 1 of 4 & 2 of 4 (Pacific version shown on sheets 3 of 4 mm & 4 of 4) MATERIAL - TOLERANCES UNLESS OTHERWISE SPECIFIED: - 0 PLC 1 PLC 2 PLC 3 PLC 4 PLC ANGLES FINISH - DWN 10JAN2012 CHK 10JAN2012 APVD 10JAN2012 Y.YIN G.BAILEY S.XI TE Connectivity Harrisburg, PA 17105-3608 NAME PRODUCT SPEC - APPLICATION SPEC - - WEIGHT SIZE - A1 CAGE CODE 00779 Customer Accessible Production Drawing SHEETS 3 Ocean End Feed Applicator - DRAWING NO 2150035 SCALE 1:1 RESTRICTED TO SHEET 2 OF & 4 ARE NOT REQUIRED FOR ATLANTIC VERSION - 4 REV D 7 8 THIS DRAWING IS UNPUBLISHED. C COPYRIGHT 20 RELEASED FOR PUBLICATION 6 REVISION DESCRIPTION FEED TYPE 2- 2150035 -2 D FINE CRIMP HEIGHT ADJUST PNEUMATIC A 3 2 LOC PART NUMBER 7- 2150035 -7 4 20 ALL RIGHTS RESERVED. BY TYCO ELECTRONICS CORPORATION. 5 CRIMP TOOLING KIT A PACIFIC VERSION TERMINATOR INTERFACE ADAPTER 1 REVISIONS DIST 66 P LTR - DESCRIPTION DATE SEE SHEET 1 DWN APVD - - - - D D CRIMP WIRE INSUL APPLICATOR DATA SIZE TYPE F F 2.03 mm [.080] 3.30 mm [.130] APPL INSTRUCTIONS 408-35043 TE TERMINAL TERMINAL DATA: TE CRIMP SPECIFICATION .250 SERIES FASTIN FASTON TAB CONNECTOR TERMINAL NAME: WIRE STRIP LENGTH n 5.20-5.80 mm [.205-.228 IN] C TERMINAL APPLICATION SPECIFICATION 114-20119 - TERMINALS APPLIED TE TERMINAL 293041-1 WIRE SIZE 1.00mm2 0.75mm2 0.50mm2 0.35mm2 B 1 2 293041-2 C1__DWG_PN_1_1 INSULATION DIAMETER RANGE 2.3mm MAX [.091 IN MAX] - - - - C1__DWG_PN_2_0 TE TERMINAL C1__DWG_PN_2_1 1-293041-1 W1__DWG_WGAUGE_2 W1__DWG_WGAUGE_3 W1__DWG_WGAUGE_4 1.40+/-0.03 [.055+/-.001] 1.35+/-0.03 [.053+/-.001] 1.30+/-0.03 [.051+/-.001] 1.25+/-0.03 [.049+/-.001] C1__DWG_PN_3_0 C1__DWG_PN_3_1 TE TERMINAL W1__DWG_CRIMP_HT_1 W1__DWG_CRIMP_HT_2 W1__DWG_CRIMP_HT_3 W1__DWG_CRIMP_HT_4 5.4 5.8 6.3 6.8 RECOMMENDED SPARE PARTS REFER TO SUPPLIED INSTRUCTION SHEET FOR CLEANING, LUBRICATION AND STORAGE OF APPLICATOR. 3 APPLY PART NUMBER 2-23419-6 LOCTITE TO THREADS OF ITEM 242. 4 CRIMP HEIGHT REFERENCE SETTING WAS THE SETTING USED WHEN THE APPLICATOR WAS QUALIFIED AT THE FACTORY. ADJUSTMENT MAY BE NECESSARY WHEN RUNNING APPLICATOR IN THE FIELD. 5 C1__DWG_PN_4_0 1-293041-2 CRIMP HEIGHT REFERENCE SETTING CRIMP HEIGHT mm [INCH] W1__DWG_WGAUGE_1 3 5 TE TERMINAL C1__DWG_PN_1_0 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 4 - REF - 1 - 1 - 1 - 1 - 1 - 1 - 2 - 1 - 2 - 1 - 4 - 2 - 2 - 2 - 1 - 1 - 1 - 8 - 2 - 2 - 1 - 2 - 1 - 2 - 1 - 1 - 1 - 1 - 1 - - 1 1 1 - 1 - 1 - 1 1 1 - 1 1 1 TERMINAL PITCH NOT COMPATIBLE WITH MECHANICAL FEED. C1__DWG_PN_4_1 4 W1__FA_SETTING_1 W1__FA_SETTING_2 W1__FA_SETTING_3 W1__FA_SETTING_4 *WARNING ON INSTALLATION, SET WIRE DISC TO CRIMP HEIGHT REFERENCE SETTING FOR LARGEST WIRE SIZE. CRIMP HEIGHT REFERENCE SETTINGS GREATER THAN THE VALUE SHOWN MAY CAUSE DAMAGE TO THE CRIMP TOOLING. REFER TO THE INSTRUCTION SHEET FOR PROPER SETUP AND ADJUSTMENTS. 6. UNLESS SPECIFIED OTHERWISE TORQUE VALUES SHALL BE USED PER DOCUMENT, 101-35000. 1 1 1 1 1 1 A 2119082-9 2079764-1 2119083-1 2844940-4 1-18028-0 5018030-1 811242-5 690753-2 2079383-9 994970-2 2119641-2 2168083-8 2119655-6 1803518-1 455888-4 1803607-4 2-18032-2 2119740-1 2168078-1 5-18022-5 2168400-4 2168083-9 5018030-1 986965-8 2063961-9 18023-9 1803602-1 1-18028-2 2168083-9 2168083-2 240639-1 1-2168083-5 1752371-5 2-22281-3 1803292-4 1-1901696-2 1-1901695-2 3-240641-3 240644-1 690482-6 1333216-8 2217206-4 5-240641-0 238011-2 2-1633961-6 455888-6 2-456405-5 1 1 1 1 1 1 1 1 4 1 1 1 1 1 1 1 2 1 2 1 4 2 2 2 1 2 1 8 2 2 1 2 1 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 -77 -22 PART NO THIS DRAWING IS A CONTROLLED DOCUMENT FOR TYCO ELECTRONICS CORPORATION IT IS SUBJECT TO CHANGE AND THE CONTROLLING ENGINEERING ORGANIZATION SHOULD BE CONTACTED FOR THE LATEST REVISION. DIMENSIONS: PACIFIC VERSION Shown on sheets 3 of 4 & 4 of 4 (Atlantic version shown on sheets 1 of 4 AMP 4805 REV 31MAR2000 mm & 2 of 4) MATERIAL - TOLERANCES UNLESS OTHERWISE SPECIFIED: - 0 PLC 1 PLC 2 PLC 3 PLC 4 PLC ANGLES FINISH - DWN 10JAN2012 CHK 10JAN2012 APVD 10JAN2012 Y.YIN G.BAILEY S.XI TE Connectivity Harrisburg, PA 17105-3608 NAME - APPLICATION SPEC - WEIGHT SIZE - A1 CAGE CODE 00779 Customer Accessible Production Drawing SHEETS 1 ITEM NO DESCRIPTION PRODUCT SPEC - 244 243 242 238 192 190 189 188 186 164 152 144 141 140 82 71 70 67 66 59 57 56 54 53 51 49 41 33 31 29 27 25 24 22 20 19 18 16 11 10 9 8 7 5 4 3 2 1 CAM, SNAIL, INSULATION ADJUSTMENT WASHER, WAVE SPRING, CREST-TO-CREST RETAINER, INSULATION DIAL AIR FEED MODULE WASHER, FLAT, REG M8 NUT, HEX, REG, RoHS, M3 BUMPER, HOLD DOWN SPACER, TONKER SCR, BHSC, RoHS (M6 X 20) COUNTER, MAGNETIC FEED CAM, AIR FEED SCR, SKT HD CAP, RoHS, M4 X 16 APPLICATOR BASIC ASSEMBLY, EF RAM ASSEMBLY, EF PACIFIC SPACER, CRIMPER DOCUMENTATION PACKAGE SCR, SET, FLT PNT, M3 X 10.0 TAG,IDENTIFICATION SCREW, DRIVE, RH, RoHS, 2 x .188 SCR, HEX HD CAP, M4 X 6.0 SHCS, LOW HEAD, RoHS, M4 X 8 SCR, SKT HD CAP, RoHS, M4 X 20 NUT, HEX, REG, RoHS, M3 NUT, LOCK, HEX, TORQUE (M4) FEED FINGER SCR, SKT HD CAP M4 X 6.0 SCR, BHSC, RoHS (M8 X 25) WASHER, FLAT, REG M4 SCR, SKT HD CAP, RoHS, M4 X 20 SCR, SKT HD CAP, RoHS, M4 X 8.0 STRIPPER (MACHINING) SCR, SKT HD CAP, RoHS, M4 X 30 PLATE, STRIP GUIDE SPRING, COMPRESSION DRAG STRIP GUIDE, REAR STRIP GUIDE, FRONT SPACER PLATE, REAR SHEAR PLATE, FRONT SHEAR ANVIL, COMBINATION BLADE, SLUG SPACER BLOCK, CRIMPER SPACER CRIMPER, INSULATION F PREMIUM SPACER, CRIMPER CRIMPER, WIRE PREMIUM Ocean End Feed Applicator - DRAWING NO 2150035 SCALE 1:1 RESTRICTED TO SHEET 3 OF - 4 & 2 ARE NOT REQUIRED FOR PACIFIC VERSION REV D C B A 7 8 THIS DRAWING IS UNPUBLISHED. C COPYRIGHT RELEASED FOR PUBLICATION BY TYCO ELECTRONICS CORPORATION. 20 6 5 4 3 2 20 LOC A ALL RIGHTS RESERVED. 1 REVISIONS DIST 66 P LTR DESCRIPTION SEE SHEET 1 - 35.58 0.05 DATE DWN APVD - - - 140 REF D D 140 2 1 16 243 RAM SET-UP 2 56 7 244 3 FEED TYPE 188 242 PNEUMATIC 5 238 82 1 190 1 189 A 59 C C 2 3 SEE DETAIL A 1 4 192 41 51 25 70 FEED SPRING SETTING POSITION 54 20 A 2 57 33 164 19 67 DETAIL A 18 B B 66 CAM POSITION 30mm STROKE 152 29 33 27 8 1 144 141 31 9 1 11 1 186 53 33 22 24 A A THIS DRAWING IS A CONTROLLED DOCUMENT FOR TYCO ELECTRONICS CORPORATION IT IS SUBJECT TO CHANGE AND THE CONTROLLING ENGINEERING ORGANIZATION SHOULD BE CONTACTED FOR THE LATEST REVISION. 49 AIR FEED PACIFIC VERSION Shown on sheets 3 of 4 & 4 of 4 (Atlantic version shown on sheets 1 of 4 DIMENSIONS: mm & 2 of 4) MATERIAL AMP 4805 REV 31MAR2000 - TOLERANCES UNLESS OTHERWISE SPECIFIED: - 0 PLC 1 PLC 2 PLC 3 PLC 4 PLC ANGLES FINISH - DWN 10JAN2012 CHK 10JAN2012 APVD 10JAN2012 Y.YIN G.BAILEY S.XI TE Connectivity Harrisburg, PA 17105-3608 NAME PRODUCT SPEC - APPLICATION SPEC - - WEIGHT SIZE - A1 CAGE CODE 00779 Customer Accessible Production Drawing SHEETS 1 Ocean End Feed Applicator - DRAWING NO 2150035 SCALE 1:1 RESTRICTED TO SHEET 4 OF - 4 & 2 ARE NOT REQUIRED FOR PACIFIC VERSION REV D
2150035-2 价格&库存

很抱歉,暂时无法提供与“2150035-2”相匹配的价格&库存,您可以联系我们找货

免费人工找货